Miller BIG BLUE 502D (DEUTZ) Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire
Big Blue 402D, 502D, 602D
OM-495 192 774L
August 2000
Processes
Description
Air Carbon Arc (CAC-A)
Cutting and Gouging
Stick (SMAW) Welding
Engine Driven Welding Generator
TIG (GTAW) Welding
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Visit our website at
www.MillerWelds.com
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor
to receive the latest full line catalog or
individual catalog sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller,
or visit us at www.MillerWelds.com on the web.
Thank you and congratulations on choosing Miller. Now
you can get the job done and get it done right. We know
you don’t have time to do it any other way.
That’s why when Niels Miller first started building arc
welders in 1929, he made sure his products offered
long-lasting value and superior quality. Like you, his
customers couldn’t afford anything less. Miller products
had to be more than the best they could be. They had to
be the best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owners Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They will
help you protect yourself against potential hazards on the worksite. We’ve
made installation and operation quick and easy.
With Miller you can count on years of reliable
service with proper maintenance. And if for
some reason the unit needs repair, there’s a
Troubleshooting section that will help you
figure out what the problem is. The parts list
will then help you to decide which exact part
you may need to fix the problem. Warranty and
service information for your particular model
are also provided.
Miller is the first welding
equipment manufacturer in
the U.S.A. to be registered to
the ISO 9001 Quality System
Standard.
Working as hard as you do
– every power source from
Miller is backed by the most
hassle-free warranty in the
business.
From Miller to You
Miller offers a Technical
Manual which provides
more detailed service and
parts information for your
unit. To obtain a Technical
Manual, contact your local
distributor. Your distributor
can also supply you with
Welding Process Manuals
such as SMAW, GTAW,
GMAW, and GMAW-P.
ERRATA SHEET
September 28, 2000 FORM: OM-495H Thru L
Use above FORM number when ordering extra manuals.
After this manual was printed, refinements in equipment design occurred.
This sheet lists exceptions to data appearing in this manual.
CHANGES TO SECTION 14 – PARTS LIST
Replace Generator Parts List with the following:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
17
16
15
18
19
20
21
22
16
23
24
25
26
27
28
29
30
31
26
32
802 404-A
16
17
15
20
21
Duetz F3L912-Powered
Units Only
11
12 13
14
Figure 14-6. Generator
Description
Part
No.
Dia.
Mkgs.
Item
No.
Figure 14-6. Generator (Figure 14-6 Item 36)
Quantity
1 132 053 SCREW, 375-16 x 1.50hexhd pln gr 5pld 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 183 387 WASHER, conical spring .406 ID x .875 OD pltd 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 195 911 ENDBELL, gen (consisting of) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 143 220 O-RING, 2.859 ID x .139CS 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 190 464 STATOR, exciter/aux pwr 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 +191 478 STATOR, weld assembly complete 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6+197 334 STATOR, weld assembly complete (full kVA option) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 013 367 LABEL, warning moving parts 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 190 197 GUARD, generator wire mesh 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 172 674 SPRING, ext .240 OD x .041 wire x 3.500pld 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-175 211B Page 4
Description
Part
No.
Dia.
Mkgs.
Item
No.
Figure 14-6. Generator (Continued)
Quantity
10 039 207 BAFFLE, air 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 198 627 ROTOR, gen (F4L1011-Powered Units Only) (consisting of) 1. . . . . . . . . . . . . . . . . . . . . . . . . . .
12 024 617 RING, rtng ext 1.375 shaft x .050thk 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13 053 390 BEARING, ball rdl sgl row 1.370 x 2.830 x .6 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 195 547 FAN, rotor gen 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 194 468 PLATE, flex (F4L1011-Powered Units Only) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 201 879 KIT, rotor service (F3L912-Powered Units Only) (consisting of) 1. . . . . . . . . . . . . . . . . . . . . . . . .
12 024 617 RING, rtng ext 1.375 shaft x .050thk 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13 053 390 BEARING, ball rdl sgl row 1.370 x 2.830 x .6 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 192 963 FAN, rotor gen 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 192 962 ADAPTER, fan/flywheel 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 083 883 WASHER, lock .042 ID x 0.709 OD 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 049 026 SCREW, M10-1.5 x 25hexhd pln 8.8pln 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 605 231 SCREW, m101.5x 35 hex hdpln 8.8 pld 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 194 512 WASHER, flat 1.250 od x .406id x 7ga thk stl pld 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 183 387 WASHER, cone .380idx .860odx.109t stl pld 4000lbs 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21 198 631 NUT, m10 hex lock nut stl pld 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 191 579 COVER, starter hole Perkins/Continental 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 172 555 SCREW, M10-1.5 x 50hexhd pln 8.8pld 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 602 159 SCREW, .31218x .75 hexwhd.66d stl pld slffmg taprw 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 601 961 SCREW, .312-18 x 2.25hexhd pln gr 5pld 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26 602 211 WASHER, lock .318 ID x 0.586 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27 139 341 WASHER, exciter 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28 *190 823 BRUSH, contact 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29 188 560 CLIP, spring 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 189 142 BRUSHHOLDER ASSEMBLY, gen 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31 602 242 WASHER, flat .375IDx0.875odx.083t stl pld 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32 604 534 SCREW, .31218x1.25 hex hdpln gr5 pld 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
190 259 HARNESS, brush (consisting of) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PLG1 168 071 CONNECTOR, (kit) rect univ 084 9P/S 3 row plug cable lkg 1. . . . . . . . . . . . . . . . . . . . . . . . . .
187 651 SEAL, wire univ 9P/S 3 row 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+ When ordering a component originally displaying a precautionary label, the label should also be ordered. Order
label individually or as part of Label Kit 192 505.
*Recommended Spare Parts.
To maintain the factory original performance of your equipment, use only Manufacturers Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
TABLE OF CONTENTS
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING 1. . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Engine Hazards 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Additional Symbols For Installation, Operation, And Maintenance 3. . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 CONSIGNES DE SÉCURITÉ LIRE AVANT UTILISATION 5. . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à larc 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Dangers existant en relation avec le moteur 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Dangers supplémentaires en relation avec linstallation, le fonctionnement
et la maintenance 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principales normes de sécurité 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. Information sur les champs électromagnétiques 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 DEFINITIONS 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Symbols And Definitions 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 SPECIFICATIONS 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Weld, Power, And Engine Specifications 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Dimensions, Weights, And Operating Angles 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Volt-Ampere Curves For CC Models 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Volt-Ampere Curves For CC/CV Models 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. Fuel Consumption 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6. Duty Cycle And Overheating 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7. AC Auxiliary Power Curve 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-8. Optional AC Power Plant Curves 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 INSTALLATION 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Installing Welding Generator (See Sections 4-2 And 4-3) 14. . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Using Lifting Eye 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Mounting Welding Generator 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Installing Exhaust Pipe 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Activating The Dry Charge Battery (If Applicable) 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Connecting The Battery 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Installing Optional Ether Cylinder (Deutz F3L912 Engine Only) 17. . . . . . . . . . . . . . . . . . . . . . .
4-8. Engine Prestart Checks 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. Connecting To Weld Output Terminals 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-10. Selecting Weld Cable Sizes 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-11. Connecting To Remote Amperage Adjust Receptacle RC13 On CC Models 20. . . . . . . . . . . . .
4-12. Connecting To Remote 14 Receptacle RC14 On CC/CV Models 21. . . . . . . . . . . . . . . . . . . . . .
SECTION 5 OPERATING WELDING GENERATOR CC MODELS 22. . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Front Panel Controls For CC Models (See Section 5-2) 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Description Of Front Panel Controls For CC Models (See Section 5-1) 23. . . . . . . . . . . . . . . . .
5-3. Remote Amperage Control On CC Models (Optional) 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 OPERATING WELDING GENERATOR CC/CV MODELS 25. . . . . . . . . . . . . . . . . . . . . .
6-1. Front Panel Controls For CC/CV Models (See Section 6-2) 25. . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Description Of Front Panel Controls For CC/CV Models (See Section 6-1) 26. . . . . . . . . . . . . .
6-3. Process/Contactor Switch On CC/CV Models 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-4. Remote Voltage/Amperage Control On CC/CV Models (Optional) 28. . . . . . . . . . . . . . . . . . . . .
SECTION 7 OPERATING AUXILIARY EQUIPMENT 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-1. 120 Volt And 240 Volt Receptacles 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-2. Connecting To Optional Auxiliary Power Plant (CC/CV Models Only) 30. . . . . . . . . . . . . . . . . .
(Continued)
The following terms are
used interchangeably
throughout this manual:
Stick = SMAW
TIG = GTAW
MIG = GMAW
CALIFORNIA
Proposition 65
Warning
Diesel engine exhaust and
some of its constituents
are known to the State of
California to cause
cancer, birth defects, and
other reproductive harm.
WARNING
This product, when used
for welding or cutting,
produces fumes or
gases which contain
chemicals known to the
State of California to
cause birth defects and,
in some cases, cancer.
(California Health &
Safety Code Section
25249.5 et seq.)
WARNING
Battery posts, terminals
and related accessories
contain lead and lead
compounds, chemicals
known to the State of
California to cause
cancer and birth defects
or other reproductive
harm. Wash hands after
handling.
TABLE OF CONTENTS
SECTION 8 MAINTENANCE (DEUTZ F4L1011POWERED UNITS) 31. . . . . . . . . . . . . . . . . . . . . . . . .
8-1. Routine Maintenance (Deutz F4L1011-Powered Units) 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-2. Maintenance Label 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-3. Servicing Air Cleaner (Deutz F4L1011-Powered Units) 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-4. Inspecting And Cleaning Optional Spark Arrestor Muffler (Deutz F4L1011-Powered Units) 34
8-5. Adjusting Engine Speed (Deutz F4L1011-Powered Units) 35. . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-6. Servicing Fuel And Lubrication Systems (Deutz F4L1011-Powered Units) 36. . . . . . . . . . . . . .
8-7. Overload Protection (Deutz F4L1011-Powered Units) 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 MAINTENANCE (DEUTZ F3L912POWERED UNITS) 38. . . . . . . . . . . . . . . . . . . . . . . . .
9-1. Routine Maintenance (Deutz F3L912-Powered Units) 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-2. Maintenance Label 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-3. Servicing Air Cleaner (Deutz F3L912-Powered Units) 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-4. Inspecting And Cleaning Optional Spark Arrestor Muffler (Deutz F3L912-Powered Units) 41.
9-5. Adjusting Engine Speed (Deutz F3L912-Powered Units) 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-6. Servicing Optional Ether Starting Aid (Deutz F3L912-Powered Units) 42. . . . . . . . . . . . . . . . . .
9-7. Servicing Fuel And Lubrication Systems (Deutz F3L912-Powered Units) 43. . . . . . . . . . . . . . .
9-8. Overload Protection (Deutz F3L912-Powered Units) 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 10 TROUBLESHOOTING 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-1. Diagnosing Causes Of Engine Fault Shutdowns 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-2. Troubleshooting Tables 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 11 ELECTRICAL DIAGRAMS 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 12 RUN-IN PROCEDURE 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-1. Wetstacking 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-2. Run-In Procedure Using Load Bank 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-3. Run-In Procedure Using Resistance Grid 60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 13 AUXILIARY POWER GUIDELINES 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 14 PARTS LIST 68. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
WARRANTY
OM-495 Page 1
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING
rom _nd_11/98
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
Marks a special safety message.
Means “Note”; not safety related.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-5. Read and follow all
Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
Do not touch live electrical parts.
Wear dry, hole-free insulating gloves and body protection.
Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
Use AC output ONLY if required for the welding process.
If AC output is required, use remote output control if present on
unit.
Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
Properly install and ground this equipment according to its
Owners Manual and national, state, and local codes.
Always verify the supply ground check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
When making input connections, attach proper grounding conduc-
tor first double-check connections.
Frequently inspect input power cord for damage or bare wiring
replace cord immediately if damaged bare wiring can kill.
Turn off all equipment when not in use.
Do not use worn, damaged, undersized, or poorly spliced cables.
Do not drape cables over your body.
If earth grounding of the workpiece is required, ground it directly
with a separate cable.
Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
Wear a safety harness if working above floor level.
Keep all panels and covers securely in place.
Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists after stopping
engine on inverters.
Stop engine on inverter and discharge input capacitors according
to instructions in Maintenance Section before touching any parts.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
ARC RAYS can burn eyes and skin.
Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes from arc rays and sparks when welding or
watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).
Wear approved safety glasses with side shields under your
helmet.
Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
Wear protective clothing made from durable, flame-resistant mate-
rial (wool and leather) and foot protection.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
FUMES AND GASES can be hazardous.
Keep your head out of the fumes. Do not breathe the fumes.
If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
If ventilation is poor, use an approved air-supplied respirator.
Read the Material Safety Data Sheets (MSDSs) and the
manufacturers instructions for metals, consumables, coatings,
cleaners, and degreasers.
Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-supplied respirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
OM-495 Page 2
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
WELDING can cause fire or explosion.
Protect yourself and others from flying sparks and hot metal.
Do not weld where flying sparks can strike flammable material.
Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
Watch for fire, and keep a fire extinguisher nearby.
Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
Do not use welder to thaw frozen pipes.
Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
FLYING METAL can injure eyes.
Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
Shut off shielding gas supply when not in use.
Always ventilate confined spaces or use ap-
proved air-supplied respirator.
HOT PARTS can cause severe burns.
Allow cooling period before maintaining.
Wear protective gloves and clothing when
working on a hot engine.
Do not touch hot engine parts or just-welded
parts bare-handed.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
Wear approved ear protection if noise level is
high.
MAGNETIC FIELDS can affect pacemakers.
Pacemaker wearers keep away.
Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
CYLINDERS can explode if damaged.
Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
Keep cylinders away from any welding or other electrical circuits.
Never drape a welding torch over a gas cylinder.
Never allow a welding electrode to touch any cylinder.
Never weld on a pressurized cylinder explosion will result.
Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and
associated parts in good condition.
Turn face away from valve outlet when opening cylinder valve.
Keep protective cap in place over valve except when cylinder is in
use or connected for use.
Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
1-3. Engine Hazards
FUEL can cause fire or explosion.
Stop engine and let it cool off before checking or
adding fuel.
Do not add fuel while smoking or if unit is near
any sparks or open flames.
Do not overfill tank allow room for fuel to expand.
Do not spill fuel. If fuel is spilled, clean up before starting engine.
Dispose of rags in a fireproof container.
STEAM AND HOT COOLANT can burn.
If possible, check coolant level when engine is
cold to avoid scalding.
Always check coolant level at overflow tank, if
present on unit, instead of radiator (unless told
otherwise in maintenance section or engine
manual).
If the engine is warm, checking is needed, and
there is no overflow tank, follow the next two
statements.
Wear safety glasses and gloves and put a rag over radiator cap.
Turn cap slightly and let pressure escape slowly before completely
removing cap.
OM-495 Page 3
MOVING PARTS can cause injury.
Keep away from fans, belts, and rotors.
Keep all doors, panels, covers, and guards
closed and securely in place.
Stop engine before installing or connecting unit.
Have only qualified people remove guards or covers for maint-
enance and troubleshooting as necessary.
To prevent accidental starting during servicing, disconnect
negative () battery cable from battery.
Keep hands, hair, loose clothing, and tools away from moving
parts.
Reinstall panels or guards and close doors when servicing is
finished and before starting engine.
Before working on generator, remove spark plugs or injectors to
keep engine from kicking back or starting.
Block flywheel so that it will not turn while working on generator
components.
BATTERY EXPLOSION can BLIND.
Always wear a face shield, rubber gloves, and
protective clothing when working on a battery.
Stop engine before disconnecting or connect-
ing battery cables or servicing battery.
Do not allow tools to cause sparks when working on a battery.
Do not use welder to charge batteries or jump start vehicles.
Observe correct polarity (+ and ) on batteries.
Disconnect negative () cable first and connect it last.
BATTERY ACID can BURN SKIN and
EYES.
Do not tip battery.
Replace damaged battery.
Flush eyes and skin immediately with water.
ENGINE EXHAUST GASES can kill.
Use equipment outside in open, well-ventilated
areas.
If used in a closed area, vent engine exhaust
outside and away from any building air intakes.
ENGINE HEAT can cause fire.
Do not locate unit on, over, or near combustible
surfaces or flammables.
Keep exhaust and exhaust pipes way from
flammables.
EXHAUST SPARKS can cause fire.
Do not let engine exhaust sparks cause fire.
Use approved engine exhaust spark arrestor in
required areas see applicable codes.
1-4. Additional Symbols For Installation, Operation, And Maintenance
FALLING UNIT can cause injury.
Use lifting eye to lift unit only, NOT running
gear, gas cylinders, trailer, or any other
accessories.
Use equipment of adequate capacity to lift and
support unit.
If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
FLYING SPARKS can cause injury.
Wear a face shield to protect eyes and face.
Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
Sparks can cause fires keep flammables away.
OVERHEATING can damage motors.
Turn off or unplug equipment before starting or
stopping engine.
Do not let low voltage and frequency caused by
low engine speed damage electric motors.
Do not connect 50 or 60 Hertz motors to the 100 Hertz receptacle
where applicable.
OVERUSE can cause OVERHEATING.
Allow cooling period; follow rated duty cycle.
Reduce current or reduce duty cycle before
starting to weld again.
Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
Put on grounded wrist strap BEFORE handling
boards or parts.
Use proper static-proof bags and boxes to
store, move, or ship PC boards.
TILTING OF TRAILER can cause injury.
Use tongue jack or blocks to support weight.
Properly install welding generator onto trailer
according to instructions supplied with trailer.
READ INSTRUCTIONS.
Use only genuine MILLER replacement parts.
Perform engine maintenance and service
according to this manual and the engine
manual.
OM-495 Page 4
H.F. RADIATION can cause interference.
High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
ARC WELDING can cause interference.
Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
1-5. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-
dent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
National Electrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
1-6. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
Welding current, as it flows through welding cables, will cause electro-
magnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: The body of evidence, in the
committees judgment, has not demonstrated that exposure to power-
frequency electric and magnetic fields is a human-health hazard.
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
To reduce magnetic fields in the workplace, use the following
procedures:
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from
operator as practical.
5. Connect work clamp to workpiece as close to the weld as possi-
ble.
About Pacemakers:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-495 Page 5
SECTION 1 CONSIGNES DE SÉCURITÉ LIRE AVANT
UTILISATION
rom _nd_fre 11/98
1-1. Signification des symboles
Signifie Mise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Identifie un message de sécurité particulier.
Signifie NOTA ; nest pas relatif à la sécurité.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
1-2. Dangers relatifs au soudage à larc
Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les ris-
ques de danger. Lorsque vous voyez un symbole, soyez
vigilant et suivez les directives mentionnées afin d’éviter tout
danger. Les consignes de sécurité présentées ci-après ne font
que résumer linformation contenue dans les normes de sécu-
rité énumérées à la section 1-5. Veuillez lire et respecter toutes
ces normes de sécurité.
Linstallation, lutilisation, lentretien et les réparations ne
doivent être confiés qu’à des personnes qualifiées.
Au cours de lutilisation, tenir toute personne à l’écart et plus
particulièrement les enfants.
UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension dès
que lappareil est sur ON. Le circuit dentrée et les circuits
internes de lappareil sont également sous tension à ce
moment-là. En soudage semi-automatique ou automatique, le fil, le dévidoir, le
logement des galets dentraînement et les pièces métalliques en contact avec
le fil de soudage sont sous tension. Des matériels mal installés ou mal mis à la
terre présentent un danger.
Ne jamais toucher les pièces électriques sous tension.
Porter des gants et des vêtements de protection secs ne comportant pas
de trous.
Sisoler de la pièce et de la terre au moyen de tapis ou dautres moyens iso-
lants suffisamment grands pour empêcher le contact physique éventuel
avec la pièce ou la terre.
Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
Se servir dune source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
Si lutilisation dune source électrique àcourant électrique savère néces-
saire, se servir de la fonction de télécommande si lappareil en est équipé.
Couper lalimentation ou arrêter le moteur avant de procéder à linstallation,
à la réparation ou à lentretien de lappareil. Déverrouiller lalimentation
selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
Installer et mettre à la terre correctement cet appareil conformément à son
manuel dutilisation et aux codes nationaux, provinciaux et municipaux.
Toujours vérifier la terre du cordon dalimentation Vérifier et sassurer que
le fil de terre du cordon dalimentation est bien raccordé à la borne de terre
du sectionneur ou que la fiche du cordon est raccordée à une prise
correctement mise à la terre.
En effectuant les raccordements dentrée fixer dabord le conducteur de
mise à la terre approprié et contre-vérifier les connexions.
Vérifier fréquemment le cordon dalimentation pour voir sil nest pas en-
dommagé ou dénudé remplacer le cordon immédiatement sil est
endommagé un câble dénudé peut provoquer une électrocution.
Mettre lappareil hors tension quand on ne lutilise pas.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou
mal épissés.
Ne pas enrouler les câbles autour du corps.
Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct ne pas utiliser le connecteur de pièce ou le câble de retour.
Ne pas toucher l’électrode quand on est en contact avec la pièce, la terre ou
une électrode provenant dune autre machine.
Nutiliser quun matériel en bon état. Réparer ou remplacer sur-le-champ
les pièces endommagées. Entretenir lappareil conformément à ce
manuel.
Porter un harnais de sécurité quand on travaille en hauteur.
Maintenir solidement en place tous les panneaux et capots.
Fixer le câble de retour de façon à obtenir un bon contact métal-métal avec
la pièce à souder ou la table de travail, le plus près possible de la soudure.
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.
Une tension DC importante subsiste à lintérieur
des onduleurs après avoir coupé lalimentation.
Couper lalimentation du poste et décharger les condensateurs dentrée
comme indiqué dans la Section Maintenance avant de toucher des compo-
sants.
Le rayonnement de larc du procédé de soudage génère
des rayons visibles et invisibles intenses (ultraviolets et
infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la
peau. Des étincelles sont projetées pendant le soudage.
LES RAYONS DE LARC peuvent pro-
voquer des brûlures dans les yeux et
sur la peau.
Porter un casque de soudage muni dun écran de filtre approprié pour pro-
téger votre visage et vos yeux pendant le soudage ou pour regarder (voir
ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair et de
l’éblouissement; demander aux autres personnes de ne pas regarder larc.
Porter des vêtements de protection constitué dans une matière durable, ré-
sistant au feu (laine ou cuir) et une protection des pieds.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur inhalation
peut être dangereux pour votre santé.
Eloigner votre tête des fumées. Ne pas respirer les fumées.
À linterieur, ventiler la zone et/ou utiliser un échappement au niveau de
larc pour l’évacuation des fumées et des gaz de soudage.
Si la ventilation est insuffisante, utiliser un respirateur à alimentation dair
homologué.
Lire les spécifications de sécurité des matériaux (MSDSs) et les instruc-
tions du fabricant concernant les métaux, les consommables, les
revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement sil est bien ventilé ou en por-
tant un respirateur à alimentation dair. Demander toujours à un surveillant
dûment formé de se tenir à proximité. Des fumées et des gaz de soudage
peuvent déplacer lair et abaisser le niveau doxygène provoquant des
blessures ou des accidents mortels. Sassurer que lair de respiration ne
présente aucun danger.
Ne pas souder dans des endroits situés à proximité dopérations de dé-
graissage, de nettoyage ou de pulvérisation. La chaleur et les rayons de
larc peuvent réagir en présence de vapeurs et former des gaz hautement
toxiques et irritants.
Ne pas souder des métaux munis dun revêtement, tels que lacier galvani-
sé, plaqué en plomb ou au cadmium à moins que le revêtement nait été3
enlevé dans la zone de soudure, que lendroit soit bien ventilé, et si néces-
saire, en portant un respirateur à alimentation dair. Les revêtements et
tous les métaux renfermant ces éléments peuvent dégager des fumées
toxiques en cas de soudage.
OM-495 Page 6
Le soudage effectué sur des conteneurs fermés tels que
des réservoirs, tambours ou des conduites peut provoquer
leur éclatement. Des étincelles peuvent être projetées de
larc de soudure. La projection d’étincelles, des pièces chaudes et des
équipements chauds peut provoquer des incendies et des brûlures. Le contact
accidentel de l’électrode avec des objets métalliques peut provoquer des
étincelles, une explosion, un surchauffement ou un incendie. Avant de
commencer le soudage, vérifier et sassurer que lendroit ne présente pas de
danger.
LE SOUDAGE peut provoquer un in-
cendie ou une explosion.
Se protéger et dautres personnes de la projection d’étincelles et de métal
chaud.
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur des
substances inflammables.
Déplacer toutes les substances inflammables à une distance de 10,7 m de
larc de soudage. En cas dimpossibilité les recouvrir soigneusement avec
des protections homologués.
Des étincelles et des matériaux chauds du soudage peuvent facilement
passer dans dautres zones en traversant de petites fissures et des
ouvertures.
Surveiller tout déclenchement dincendie et tenir un extincteur à proximité.
Le soudage effectué sur un plafond, plancher, paroi ou séparation peut dé-
clencher un incendie de lautre côté.
Ne pas effectuer le soudage sur des conteneurs fermés tels que des réser-
voirs, tambours, ou conduites, à moins quils naient été préparés
correctement conformément à AWS F4.1 (voir les normes de sécurité).
Brancher le câble sur la pièce le plus près possible de la zone de soudage
pour éviter le transport du courant sur une longue distance par des che-
mins inconnus éventuels en provoquant des risques d’électrocution et
dincendie.
Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
En cas de non utilisation, enlever la baguette d’électrode du porte-électro-
de ou couper le fil à la pointe de contact.
Porter des vêtements de protection dépourvus dhuile tels que des gants
en cuir, une chemise en matériau lourd, des pantalons sans revers, des
chaussures hautes et un couvre chef.
Avant de souder, retirer toute substance combustible de vos poches telles
quun allumeur au butane ou des allumettes.
DES PARTICULES VOLANTES
peuvent blesser les yeux.
Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques vo-
lantes. Pendant la période de refroidissement des soudures, elles ris-
quent de projeter du laitier.
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
LES ACCUMULATIONS DE GAZ ris-
quent de provoquer des blessures ou
même la mort.
Fermer lalimentation du gaz protecteur en cas de
non utilisation.
Veiller toujours à bien aérer les espaces confinés ou se servir dun respi-
rateur dadduction dair homologué.
DES PIÈCES CHAUDES peuvent
provoquer des brûlures graves.
Prévoir une période de refroidissement avant deffec-
tuer des travaux dentretien.
Porter des gants et des vêtements de protection pour
travailler sur un moteur chaud.
Ne pas toucher à mains nues les parties chaudes du moteur ni les pièces
récemment soudées.
LE BRUIT peut affecter louïe.
Le bruit des processus et des équipements peut affecter
louïe.
Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs dun stimulateur cardiaque doivent
dabord consulter leur médecin avant de sapprocher
des opérations de soudage à larc, de gougeage ou
de soudage par points.
Si des BOUTEILLES sont endomma-
gées, elles pourront exploser.
Des bouteilles de gaz protecteur contiennent du gaz sous
haute pression. Si une bouteille est endommagée, elle peut
exploser. Du fait que les bouteilles de gaz font normale-
ment partie du procédé de soudage, les manipuler avec
précaution.
Protéger les bouteilles de gaz comprimé dune chaleur excessive, des
chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des
arcs.
Placer les bouteilles debout en les fixant dans un support stationnaire ou
dans un porte-bouteilles pour les empêcher de tomber ou de se renverser.
Tenir les bouteilles éloignées des circuits de soudage ou autres circuits
électriques.
Ne jamais placer une torche de soudage sur une bouteille à gaz.
Une électrode de soudage ne doit jamais entrer en contact avec une bou-
teille.
Ne jamais souder une bouteille pressurisée risque dexplosion.
Utiliser seulement des bouteilles de gaz protecteur, régulateurs, tuyaux et
raccords convenables pour cette application spécifique; les maintenir ainsi
que les éléments associés en bon état.
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la bouteille.
Maintenir le chapeau de protection sur la soupape, sauf en cas dutilisation
ou de branchement de la bouteille.
Lire et suivre les instructions concernant les bouteilles de gaz comprimé,
les équipements associés et les publication P-1 CGA énumérées dans les
normes de sécurité.
1-3. Dangers existant en relation avec le moteur
LE CARBURANT MOTEUR peut pro-
voquer un incendie ou une explosion.
Arrêter le moteur avant de vérifier le niveau de carbu-
rant ou de faire le plein.
Ne pas faire le plein en fumant ou proche dune sour-
ce d’étincelles ou dune flamme nue.
Ne pas faire le plein de carburant à ras bord; prévoir de lespace pour son
expansion.
Faire attention de ne pas renverser de carburant. Nettoyer tout carbu-
rant renversé avant de faire démarrer le moteur.
Jeter les chiffons dans un récipient ignifuge.
LA VAPEUR ET LE LIQUIDE DE
REFROIDISSEMENT CHAUD peuvent
provoquer des brûlures.
Il est préférable de vérifier le liquide de
refroidissement une fois le moteur refroidi pour éviter
de se brûler.
Toujours vérifier le niveau de liquide de refroidissement dans le vase
dexpansion (si présent), et non dans le radiateur (sauf si précisé autre-
ment dans la section maintenance du manuel du moteur).
Si le moteur est chaud et que le liquide doit être vérifié, opérer comme
suivant :
Mettre des lunettes de sécurité et des gants, placer un torchon sur le
bouchon du radiateur.
Dévisser le bouchon légèrement et laisser la vapeur s’échapper avant
denlever le bouchon.
OM-495 Page 7
DES ORGANES MOBILES peuvent
provoquer des blessures.
Ne pas approcher les mains des ventilateurs, cour-
roies et autres pièces en mouvement.
Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.
Arrêter le moteur avant dinstaller ou brancher lappareil.
Demander seulement à un personnel qualifié denlever les dispositifs de
sécurité ou les recouvrements pour effectuer, sil y a lieu, des travaux
dentretien et de dépannage.
Pour empêcher tout démarrage accidentel pendant les travaux dentre-
tien, débrancher le câble négatif () de batterie de la borne.
Ne pas approcher les mains, cheveux, vêtements lâches et outils des or-
ganes mobiles.
Remettre en place les panneaux ou les dipositifs de protection et fermer
les portes à la fin des travaux dentretien et avant de faire démarrer le
moteur.
Avant dintervenir, déposer les bougies ou injecteurs pour éviter la mise
en route accidentelle du moteur.
Bloquer le volant moteur pour éviter sa rotation lors dune intervention
sur le générateur.
LEXPLOSION DE LA BATTERIE peut
RENDRE AVEUGLE.
Toujours porter une protection faciale, des gants en
caoutchouc et vêtements de protection lors dune in-
tervention sur la batterie.
Arrêter le moteur avant de débrancher ou de brancher les câbles de
batterie.
Eviter de provoquer des étincelles avec les outils en travaillant sur la
batterie.
Ne pas utiliser le poste de soudage pour charger les batteries ou des vé-
hicules de démarrage rapide.
Observer la polarité correcte (+ et ) sur les batteries.
Débrancher le câble négatif () en premier lieu. Le rebrancher en dernier
lieu.
LACIDE DE LA BATTERIE peut pro-
voquer des brûlures dans les YEUX et
sur la PEAU.
Ne pas renverser la batterie.
Remplacer une batterie endommagée.
Rincer immédiatement les yeux et la peau à leau.
LES GAZ D’ÈCHAPPEMENT DU
MOTEUR peuvent provoquer des
accidents mortels.
Utiliser l’équipement à lextérieur dans des zones ou-
vertes et bien ventilées.
En cas dutilisation dans un endroit fermé évacuer les gaz d’échappe-
ment du moteur vers lextérieur à distance des entrées dair dans les bâti-
ments.
LA CHALEUR DU MOTEUR peut pro-
voquer un incendie.
Ne pas placer lappareil sur, au-dessus ou à proximité
de surfaces inflammables.
Tenir à distance les produits inflammables de
l’échappement.
LES ÉTINCELLES À L’ÉCHAPPEMENT
peuvent provoquer un incendie.
Empêcher les étincelles d’échappement du moteur
de provoquer un incendie.
Utiliser uniquement un pare-étincelles approuvé
voir codes en vigueur.
1-4. Dangers supplémentaires en relation avec linstallation, le fonctionnement
et la maintenance
LA CHUTE DE LAPPAREIL peut
blesser.
Utiliser lanneau de levage uniquement pour soulever
lappareil lui-même ; sans chariot, de bouteilles de
gaz, remorque, ou autres accessoires.
Utiliser un équipement de levage de capacité suffi-
sante pour lever lappareil.
En utilisant des fourches de levage pour déplacer lunité, sassurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de lappareil.
LES ÉTINCELLES VOLANTES ris-
quent de provoquer des blessures.
Porter un écran facial pour protéger le visage et les
yeux.
Affuterr l’électrode au tungstène uniquement à la meuleuse dotée de pro-
tecteurs. Cette manoeuvre est à exécuter dans un endroit sûr lorsque
lon porte l’équipement homologué de protection du visage, des mains et
du corps.
Les étincelles risquent de causer un incendie éloigner toute substance
inflammable.
LE SURCHAUFFEMENT peut endom-
mager le moteur électrique.
Arrêter ou déconnecter l’équipement avant de dé-
marrer ou darrêter le moteur.
Ne pas laisser tourner le moteur trop lentement sous
risque dendommager le moteur électrique à cause
dune tension et dune fréquence trop faibles.
Ne pas brancher de moteur de 50 ou de 60 Hz à la prise de 100 Hz, sil y a
lieu.
LEMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
Laisser l’équipement refroidir ; respecter le facteur de
marche nominal.
Réduire le courant ou le facteur de marche avant de
poursuivre le soudage.
Ne pas obstruer les passages dair du poste.
LES CHARGES
ÉLECTROSTATIQUES peuvent
endommager les circuits imprimés.
Établir la connexion avec la barrette de terre avant de
manipuler des cartes ou des pièces.
Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.
UNE REMORQUE QUI BASCULE peut
entraîner des blessures.
Utiliser les supports de la remorque ou des blocs
pour soutenir le poids.
Installer convenablement le poste sur la remorque
comme indiqué dans le manuel sy rapportant.
LIRE LES INSTRUCTIONS.
Utiliser seulement les pièces de rechange dorigine.
Effecteur la maintenance et la mise en service
daprès le manuel et celui du moteur.
OM-495 Page 8
LE RAYONNEMENT HAUTE FRÉ-
QUENCE (H.F.) risque de provoquer
des interférences.
Le rayonnement haute fréquence (H.F.) peut
provoquer des interférences avec les équipements
de radionavigation et de communication, les
services de sécurité et les ordinateurs.
Demander seulement à des personnes qualifiées familiarisées avec des
équipements électroniques de faire fonctionner linstallation.
Lutilisateur est tenu de faire corriger rapidement par un électricien quali-
fié les interférences résultant de linstallation.
Si le FCC signale des interférences, arrêter immédiatement lappareil.
Effectuer régulièrement le contrôle et lentretien de linstallation.
Maintenir soigneusement fermés les portes et les panneaux des sources
de haute fréquence, maintenir les éclateurs à une distance correcte et
utiliser une terre et et un blindage pour réduire les interférences
éventuelles.
LE SOUDAGE À LARC risque de
provoquer des interférences.
L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement com-
mandé par ordinateur tel que les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit compatible
électromagnétiquement.
Pour réduire la possibilité dinterférence, maintenir les câbles de souda-
ge aussi courts que possible, les grouper, et les poser aussi bas que pos-
sible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement élec-
tronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre conformé-
ment à ce mode demploi.
En cas dinterférences après avoir pris les mesures précédentes, il in-
combe à lutilisateur de prendre des mesures supplémentaires telles que
le déplacement du poste, lutilisation de câbles blindés, lutilisation de fil-
tres de ligne ou la pose de protecteurs dans la zone de travail.
1-5. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de lAmerican Weld-
ing Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de lAmerican Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
National Electrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de lAssociation canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face Protec-
tion, norme ANSI Z87.1, de lAmerican National Standards Institute,
1430 Broadway, New York, NY 10018.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-6. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour lorganisme,
des champs magnétiques basse fréquence
Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: Laccumulation de preuves, suivant le
jugement du comité, na pas démontré que lexposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.
Afin de réduire les champs électromagnétiques dans lenvironnement
de travail, respecter les consignes suivantes :
1 Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
2 Mettre tous les câbles du côté opposé de lopérateur.
3 Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
4 Garder le poste de soudage et les câbles le plus loin possible de
vous.
5 Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes cidessus.
OM-495 Page 9
SECTION 2 DEFINITIONS
2-1. Symbols And Definitions
Stop Engine
Fast (Run, Weld/
Power)
Slow (Idle) Start Engine
Starting Aid Battery (Engine)
Engine Oil
Pressure
Engine Oil
Check Injectors/
Pump
Check Valve
Clearance
Fuel
Protective Earth
(Ground)
Positive Negative
Certified/Trained
Mechanic
Welding Arc
A
Amperes
V
Volts Panel/Local Remote
Engine
Air Temperature Or
Engine
Temperature
Output
Alternating
Current
Stick (SMAW)
Welding
Constant Current
(CC)
MIG (GMAW)
Welding
TIG (GTAW)
Time
h
Hours
s
Seconds
1
Single Phase
3
Three Phase
Read Operators
Manual
Circuit Breaker
Do Not Switch
While Welding
Electrode
Connection
Work Connection
SECTION 3 SPECIFICATIONS
3-1. Weld, Power, And Engine Specifications
Welding
Mode
Weld Output
Range
Rated Welding
Output
Maximum
Open-
Circuit
Voltage
Auxiliary Power Rating Engine
Fuel
Capacity
CC/DC
55 600 A
(CC Models)
20 600 A
(CC/CV Models)
400 A, 40 Volts DC,
100% Duty Cycle
500 A, 40 volts DC,
95
Standard:
Single-Phase,
4 kVA/kW, 34/17 A,
120/240 V AC,
50/60 Hz
Deutz F4L1011
Air/Oil-Cooled, Four
DEUTZ
25 gal
CV/DC
(CC/CV
Models
Only)
14 40 V
500 A, 40 volts DC,
60% Duty Cycle
600 A, 30 Volts DC,
40% Duty Cycle
56
Full kVA Option:*
Single-Phase/Three-Phase,
12/20 kVA/kW, 50/48A,
120/240 VAC, 60 Hz
*In Addition To Standard
4 kVA/kW Auxiliary Power
Cylinder, 44 HP Diesel
Engine
or
Deutz F3L912
Air-Cooled, Three
Cylinder, 41.5 HP
Diesel Engine
25 gal
(95 L)
OM-495 Page 10
3-2. Dimensions, Weights, And Operating Angles
Dimensions
Height
60 in (1524 mm)
(to top of muffler)
G
Width
28-1/2 in (724 mm)
(mtg. brackets turned in)
30-3/4 in (781 mm)
(mtg. brackets turned out)
Do not exceed tilt angles or engine could
be damaged or unit could tip.
Do not move or operate unit where it could
tip.
Depth 64-7/16 in (1637 mm)
tip.
A 64-7/16 in (1637 mm)
B 55-7/8 in (1419 mm)
A
C 46-3/8 in (1178)
B
C
D 9-1/2 in (241 mm)
E 27-1/2 in (699 mm)
°
F 1 in (25 mm)
H
30°
G 29-1/2 in (749 mm)
°
30°
H
9/16 in (14 mm) Dia.
4 Holes
Front Panel End
D
20
20°
Weight
F
w/ Deutz
F4L1011
No fuel: 1690 lb (767 kg)
w/fuel: 1880 lb (853 kg)
F
E
w/ Deutz
F3L912
No fuel: 1785 lb (810 kg)
w/fuel: 1975 lb (896 kg)
802 161-A
3-3. Volt-Ampere Curves For CC Models
Ref. 193 017
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
0
20
40
60
80
100
0 100 200 300 400 500 600 700
DC AMPERES
DC VOLTS
Ranges
300Max
185425
125320
85190
5590
OM-495 Page 11
3-4. Volt-Ampere Curves For CC/CV Models
194 364 / 194 365 / 194 366
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
A. Stick Mode
B. MIG Mode
0
20
40
60
80
100
0
100 200 300 400 500 600 700 800 900 1000
DC AMPERES
DC VOLTS
MAX
MIN
C. TIG Mode
0
20
40
60
80
100
0 50 100 150 200 250 300 350 400 450 500
DC AMPERES
DC VOLTS
Ranges
60310
40200
30130
2070
0
20
40
60
80
100
0 100 200 300 400 500 600 700 800 900 1000
DC AMPERES
DC VOLTS
Ranges
300Max
185425
125320
85190
5590
OM-495 Page 12
3-5. Fuel Consumption
The curve shows typical fuel use
under weld or power loads.
193 093
0 50 100 150 200 250 300 350 400 450 500
DC WELD AMPERES AT 100% DUTY CYCLE
1800 RPM
0
Continuous Welding
3-6. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
Exceeding duty cycle can
damage unit and void
warranty.
100% Duty Cycle At 400 Amperes
089 697-D
OM-495 Page 13
3-7. AC Auxiliary Power Curve
193 018
The ac power curve shows the aux-
iliary power in amperes available at
the 120 and 240 volt receptacles.
0
50
100
150
200
250
300
0 5 10 15 20 25 30
AC AMPERES IN 240V MODE
AC VOLTS
0
25
50
75
100
150
125
0102030405060
AC AMPERES IN 120V MODE
3-8. Optional AC Power Plant Curves
197 472 / 197 473
The ac power curves show the aux-
iliary power available in amperes at
the single-phase 120/240 volt re-
ceptacle or three-phase 240 volt
terminals.
A. 12 kVA/kW Single-Phase Auxiliary Power Plant (No Weld Load)
B. 20 kVA/kW Three-Phase Auxiliary Power Plant (No Weld Load)
180
190
200
210
220
230
240
250
260
270
280
0
20 40 60 80 100
AC AM-
PERES
AC VOLTS
180
200
220
240
260
280
0 10203040506070
AC AMPERES
90
95
100
105
110
115
120
125
130
135
140
OM-495 Page 14
SECTION 4 INSTALLATION
4-1. Installing Welding Generator (See Sections 4-2 And 4-3)
install1 12/99* Ref. 800 652 / Ref. 800 477-A / 158 936-A / 0854
1
2
Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.
GND/PE
3
4
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1 Generator Base
2 Metal Vehicle Frame
3 Equipment Grounding
Terminal
4 Grounding Cable
Use #10 AWG or larger insulated
copper wire.
If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.
2
OR
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement Airflow Clearance Location
Grounding
OR
4-2. Using Lifting Eye
Ref. 802 169-B / 802 311
1 Lifting Eye
2 Nut
3 Carriage Bolt
Raise lifting eye until it snaps in
place. Lower lifting eye when not
needed.
To lock the lifting eye in the upright
position, insert a 1/4-20 x 1-1/2 in
carriage bolt through slot in bracket
and secure with nut (bolt and nut not
supplied).
Tools Needed:
2
1
3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Miller BIG BLUE 502D (DEUTZ) Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire

dans d''autres langues