The overload indicator light○
1comes on
when an overload of a connected
electrical device is detected, the
inverter control unit overheats, or the AC
output voltage rises.Then, the AC
protector will trip, stopping power
generation in order to protect the
generator and any connected electric
devices.The AC pilot light (Green)will go
off and the overload indicator light (Red)
will stay on, but the engine will not stop
running.
when the overload indicator light comes
on and power generation stops, proceed
as follows:
1. Turn off any connected electric
devices and stop the engine.
2. Reduce the total wattage of connected
electric devices within the rated output.
3. Check for blockages in the cooling
air Inlet and around the control unit. If any
blockages are found remove.
4. After checking, restart the engine.
TIP: The overload indicator light may
come on for a few seconds at first when
using electric devices that require a large
starting current,such as a compressor or a
submergible pump. However, this is not a
malfunction.