Modern Forms WS-W68612 Skyscraper Mode d'emploi

Taper
Mode d'emploi
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
686 - LED Outdoor
WS-W68612/WS-W68618
HARDWARE
A1 B1 C1 D1 E1
Wire Connector
Qty: 3 pcs
Junction Box Screw
Qty: 2 pcs + 1 Extra
Mounting Screw
Qty: 4 Extra
Plastic Anchor
Qty: 2 Extra
Wood Screw
Qty: 2 Extra
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (C1) from the canopy.
4. Drill a hole in the wall aligned with the key-hole located in the mounting plate, insert the plastic anchor (D1) to the wall.
5. Secure the mounting plate to the junction box using the junction box screw (B1). Fasten the mounting plate to the wall using the
wood screw (E1). The side of the mounting plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)
6. Connect the xture wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet box
has a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xture’s ground wire directly to the
back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
7. Place the xture on the mounting plate, and
secure it with mounting screw (C1).
8. To prevent moisture from entering the outlet
box and causing a short, use clear caulking
(i.e. indoor/outdoor silicone sealant) to outline
the outside of xture back plate where it
meets the wall. Leave a space at the bottom to
allow moisture to escape Fig. 3.
INSTALLATION INSTRUCTION
686 - LED Outdoor
WS-W68612/WS-W68618
FIG.1
Back Plate Dimensions
C1
A1
E1
D1
B1
Mounting Screw
Wire Connector
Wood Screw
Plastic Anchor
Junction Box Screw
Ground Wire Screw
Ground Wire
Junction Box
Mounting Plate
Fixture
WS-W68612 5 1/2”
WS-W68618 6 3/4”
WS-W68612 8”
WS-W68618 11 5/8”
WS-W68612 11 1/2”
WS-W68618 17 1/2”
4”
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
Junction Box
Caulking
Fig. 3 Sealing
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
686 - LED Outdoor
WS-W68627
HARDWARE
A1 B1 C1 D1 E1
Wire Connector
Qty: 3 pcs
Junction Box Screw
Qty: 2 pcs + 1 Extra
Mounting Screw
Qty: 4 Extra
Plastic Anchor
Qty: 2 Extra
Wood Screw
Qty: 2 Extra
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (C1) from the canopy.
4. Drill a hole in the wall aligned with the key-hole located in the mounting plate, insert the plastic anchor (D1) to the wall.
5. Secure the mounting plate to the junction box using the junction box screw (B1). Fasten the mounting plate to the wall using the
wood screw (E1). The side of the mounting plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)
6. Connect the xture wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet box
has a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xture’s ground wire directly to the
back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
7. Place the xture on the mounting plate, and
secure it with mounting screw (C1).
8. To prevent moisture from entering the outlet
box and causing a short, use clear caulking
(i.e. indoor/outdoor silicone sealant) to outline
the outside of xture back plate where it
meets the wall. Leave a space at the bottom to
allow moisture to escape Fig. 3.
INSTALLATION INSTRUCTION
686 - LED Outdoor
WS-W68627
FIG.1
Back Plate Dimensions
C1
A1
E1
D1
B1
Mounting Screw
Wire Connector
Wood Screw
Plastic Anchor
Junction Box Screw
Ground Wire Screw
Ground Wire
Junction Box
Mounting Plate
Fixture
7 1/2”
16 1/8”
26 3/8”
4”
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
Junction Box
Caulking
Fig. 3 Sealing
1
INSTALLATION INSTRUCTIONS
686- Outdoor Wall Sconce
WS-W68637/WS-W68637F
HARDWARE
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2019
CAUTION: To prevent electrical shock, ensure electricity has been turned off at the circuit breaker before beginning.
Read all instructions before installing.
System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern
Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any
parts are damaged or missing.
MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the fixture. We recommend that customers in coastal
areas clean all external surfaces of the fixture once every two weeks with a wet cloth.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
Lisez toutes les instructions avant l’installation.
Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux
règlements locaux.
Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus
pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la
garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
NOTE D’ENTRETIEN: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chiffon humide.
Wire Connector
Qty: 3pcs+1 Extra
Mounting Screw
Qty:1 Extra
5/32"-32x1/2
Rubber Gasket
Qty: 1 Extra
Anchor
Qty: 2 pc
s+1 E
xtra
Wood Screw
Qty: 2 pc
s+1 E
xtra
ABCDE
2
INSTALLATION INSTRUCTIONS
686- Outdoor Wall Sconce
WS-W68637/WS-W68637F
FIG. 1
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
FIG. 2 Wiring
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2019
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1. Shut off the power at the circuit breaker and remove existing
fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on
a clear area. Be careful not to lose any small parts necessary
for installation.
MOUNTING THE FIXTURE (FIG. 1)
3. Remove the mounting screw (B) and rubber gasket (C) from
the fixture.
4. Drill holes in the wall aligned with the key holes located in
the mounting back plate, insert the plastic anchor (D).
5. Secure mounting back plate to the junction box using
standard junction box screws that comes with the junction
box, fasten it to the wall using wood screw (E).
Note: (i) Using any other non-original-manufacturer provided
junction box screw may result in safety issue;
(ii) The side of the mounting plate marked GND” must
face out.
CONNECTING THE WIRES (FIG. 2)
6. Connect the fixtures wires to junction box wires as shown
in Fig. 2, making sure that all wire connectors (A) are secured.
If your outlet box has a green or bare copper ground wire,
connect the fixture’s ground wire to it. Otherwise, connect the
fixture’s ground wire directly to the back plate using the
green screw provided. After wires are connected, tuck them
carefully inside the junction box.
7. Hook the safety cords to the back plate.
8. Place the fixture over the mounting back plate and secure it
with mounting screws (B) and the rubber gasket (C).
COMPLETING THE INSTALLATION
9 To prevent moisture from entering the outlet box and causing
a short, use clear caulking (i.e. indoor/outdoor silicone sealant)
to outline the outside of fixture back plate where it meets the
wall. Leave a space at the bottom to allow moisture to escape
(FIG.3).
Wire Connector
Junction Box
Junction Box Screw
Mounting Back Plate
Ground Wire
Mounting Screw
Wood Screw
Anchor
A
Rubber Gasket
B
C
D
E
Black Wire
White Wire
Inner Bonding Glass Cover
(RPL-GLA-68637-02)
External Acrylic Cover
(RPL-GLA-68637)
Safety Cords(Only WS-W68637-SS)
Mounting Plate Dimensions
36 5/8”
13 3/4”
1 3/4” 1 3/8”
8 5/8”
13 3/4”
Caulking
Junction Box
FIG. 3 Sealing
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Modern Forms WS-W68612 Skyscraper Mode d'emploi

Taper
Mode d'emploi