Whirlpool WVW51UC0HV Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

30" AND 36" (76.2 AND 91.4 CM)
WALL‑MOUNT CANOPY RANGE HOOD
Installation Instructions and Use and Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301
or visit our website at www.whirlpool.com
In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca
HOTTE DE CUISINIÈRE À MONTAGE MURAL
DE30" ET 36" (76,2 ET 91,4 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service, composer le 1-800-807-6777
ou visiter notre site Web à www.whirlpool.ca
Table of Contents/Table des matières
.....................................2
LIB0115584C/W11134241C
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONL
Y.
IMPOR
TANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISA
TION RÉSIDENTIELLE UNIQUEMENT
.
2
TABLE OF CONTENTS TABLE DES MATIÈRES
RANGE HOOD SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
RANGE HOOD SAFETY .................................................................2
INSTALLATION REQUIREMENTS
................................................. 4
Tools and Parts
............................................................................. 4
Location Requirements
................................................................4
Venting Requirements
..................................................................5
Electrical Requirements
...............................................................6
INSTALLATION INSTRUCTIONS
................................................... 7
Prepare Location
..........................................................................7
Install Range Hood
....................................................................... 8
Connect Vent System
..................................................................8
Make Electrical Connection
.........................................................9
Install Vent Covers
........................................................................9
Complete Installation
.................................................................10
RANGE HOOD USE
......................................................................10
Range Hood Controls
................................................................10
RANGE HOOD CARE
...................................................................11
Cleaning
.....................................................................................11
WIRING DIAGRAM
.......................................................................12
ASSISTANCE OR SERVICE
.........................................................13
In the U.S.A.
...............................................................................13
In Canada
...................................................................................13
Accessories
................................................................................13
WARRANTY
..................................................................................14
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE
...............................15
EXIGENCES D’INSTALLATION
...................................................17
Outils et pièces
...........................................................................17
Exigences d’emplacement
.........................................................17
Exigences concernant l’évacuation
...........................................18
Spécifications électriques
..........................................................20
INSTRUCTIONS D’INSTALLATION
.............................................20
Préparation de l’emplacement
...................................................20
Installation de la hotte
................................................................21
Raccordement du circuit d’évacuation
......................................22
Raccordement électrique
...........................................................22
Installation des cache-conduits
.................................................23
Achever l’installation
..................................................................23
UTILISATION DE LA HOTTE
.......................................................24
Commandes de la hotte de cuisinière
.......................................24
ENTRETIEN DE LA HOTTE
.........................................................25
Nettoyage
...................................................................................25
SCHÉMA DE CÂBLAGE
...............................................................26
ASSISTANCE OU SERVICE
.........................................................27
Au Canada
..................................................................................27
Accessoires
................................................................................27
GARANTIE
.....................................................................................27
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools Needed
Level
Drill with 1
1
/
4
" (3.2 cm), 1/8" (3.2 mm),
and 5/16" (7.9 mm) drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Parts Needed
Home power supply cable
1/2" (12.7 mm) UL Listed or CSA approved strain relief
Three UL Listed wire connectors
For Vented Installations, You Will Also Need:
One wall or roof cap
Metal vent system
For Non-Vented (Recirculating) Installations,
You Will Also Need:
Recirculation Kit - for non-vented (recirculating) installations
only. See “Assistance or Service” section to order.
6" (15.2 cm) diameter round metal vent duct -
length required is determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with blower, LED lights and
canopy glass already installed
Vent transition with back draft dampers installed
Vent cover support bracket
Metal grease filter
Mounting template
Two – piece vent cover
Two – 3.5 x 9.5 mm mounting screws (Phillips)
Four – 4.2 x 8 mm screws (T20
®†
drive)
Six – 5 x 45 mm mounting screws (#2 Phillips)
Four – 5.4 x 75 mm screws (Phillips) (for 10 x 60 mm
wall anchors)
Two – 8 x 40 mm wall anchors
Four – 10 x 60 mm wall anchors
T20
®
Torx
®†
adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall
of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops with
a maximum total rating of 65,000 BTUs or less.
Grounded electrical outlet is required. See the “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof
or wall. For non-vented (recirculating) installation, see “For
non-vented (recirculating) installation only” in the “Connect
Vent System” section. Recirculation Kit is available from your
dealer or an authorized parts distributor. See the “Assistance or
Service” section to order.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280)
or, when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A,
or latest edition, or with local codes.
Product Dimensions
20"
(50.8 cm)
30" (76.2 cm) or
36" (91.4 cm)
13³⁄₁₆"
(33.5 cm)
10
⁷⁄₈
"
(27.6 cm)
®
TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
5
* For non-vented (recirculating) installations
** For vented installations
Cabinet Dimensions
* For non-vented (recirculating) installations
IMPORTANT:
Minimum distance “X”: 24" (61 cm)
from electric cooking surface
Minimum distance “X”: 27" (68.6 cm)
from gas cooking surface
Suggested maximum distance “X”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights.
See the following chart.
Vented Installations
Min. ceiling height Max. ceiling height
Electric cooking
surface
7' 4" (2.23 m) 9' 5" (2.87 m)
Gas cooking
surface
7' 7" (2.31 m) 9' 5" (2.87 m)
Non-Vented (Recirculating) Installations
Min. ceiling height Max. ceiling height
Electric cooking
surface
7' 4" (2.23 m) 9' 9" (2.97 m)
Gas cooking
surface
7' 7" (2.31 m) 9' 9" (2.97 m)
NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soffit heights depending on the
distance “X” between the bottom of the range hood and the
cooking surface. For higher ceilings, a Chimney Extension Kit is
available from your dealer or an authorized parts distributor. The
chimney extension replaces the upper chimney shipped with the
range hood. See the “Assistance or Service” section to order.
Venting Requirements
(vented models only)
Vent system must terminate to the outdoors except
for non-vented (recirculating) installations.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the Most Efficient and Quiet Operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight
vent between the elbows if more than one elbow is used.
Do not install two elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the roof
or wall cap has a damper, do not use the damper
supplied with the range hood.
Use caulking to seal exterior wall or roof opening
around the cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
17
³⁄₁₆" (43.7 cm)
**27¹⁄₈" (68.9 cm) min.
**41¹⁄₈
" (104.5 cm) max.
*27¹⁄₈" (68.9 cm) min.
*45¹⁄₂" (115.6 cm) max.
10" (25.4 cm) min.
13" (33.0 cm) max.
9¹⁄₂" (24.1 cm)
2" (5.1 cm) min.
9" (22.9 cm) min.*
Centerline
Side
cabinet
Side
cabinet
Vent and po
wer
supply cable
entry location
20" (50.8 cm)* min.
30" (76.2 cm) or
36" (91.4 cm)
“X”
bottom of
canopy
to cooking
surface
10" (25.4 cm) min.
13" (33.0 cm) max.
Cooking surface
6
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of
air movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in
your area.
Venting Methods
This canopy hood is factory set for venting through the roof
or wall.
A 6" (15.2 cm) round vent system is needed for installation
(not included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly
reduce performance.
Vent system can terminate either through the roof or wall.
To vent through a wall, a 90° elbow is needed.
Rear Discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (Recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the
outside, the hood can be used in the non-vented (recirculating)
version, fitting a charcoal filter and the deflector. Fumes and
vapors are recycled through the top grille.
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Example Vent System
The following example falls within the maximum
recommended vent length of 35 ft (10.7 m).
1 - 90° elbow = 5 ft (1.5 m)
1 - wall cap = 0 ft (0 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
Length of system = 13 ft (3.9 m)
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 (latest edition), or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition)
and all local codes and ordinances.
If codes permit and a separate ground wire is used,
it is recommended that a qualified electrician determine
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical
circuit is required.
If the house has aluminum wiring, follow the
procedure below:
1. Connect a section of solid copper wire to the
pigtail leads.
2. Connect the aluminum wiring to the added section
of copper wire using special connectors and/or tools
designed and UL Listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial/rating plate.
The model/serial/rating plate is located behind the left filter
on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1
and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
Non-Vented
(Recirculating)
Wall VentingRoof Venting
A
A
B
B
B
A
A. Deflector
B. 6" (15.2 cm)
round vent
A. Wall cap
B. 6" (15.2 cm)
round vent
A. Roof cap
B. 6" (15.2 cm)
round vent
90 Elbo
w
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
7
INSTALLATION INSTRUCTIONS
Prepare Location
It is recommended that the vent system be installed
before hood is installed.
Before making cutouts, make sure there is proper
clearance within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height
maximum before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall,
or non-vented.
3. Select a flat surface for assembling the range hood.
Place covering over that surface.
4. Using two or more people, lift range hood onto
covered surface.
5. Remove wood base from range hood and dispose
of properly.
6. Remove the metal grease filter and the white foam shipping
block from inside the range hood located below the blower.
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the wall where
the canopy hood will be installed.
2. Select a mounting height between a minimum of 24" (61 cm)
for an electric cooking surface, a minimum of 27" (68.6 cm)
for a gas cooking surface, and a suggested maximum of
36" (91.4 cm) above the range to the bottom of the hood.
Mark a reference line on the wall.
3. Tape template in place, aligning the template centerline
and bottom of template with hood bottom line and with
the centerline marked on the wall.
4. Mark centers of the fastener locations through the template
to the wall.
IMPORTANT: All canopy mounting screws must be installed
into wood where possible. If there is no wood to screw into,
additional wall framing supports may be required or use
the (4) 10 x 60 mm wall anchors and 5.4 x 75 mm screws.
Remove the template.
5. For wood, drill 3/16" (4.8 mm) pilot holes at all locations
where screws are being installed into wood.
For wall anchors, drill 7/16" (10 mm) holes at all locations
where wall anchors are being used.
6. For wood, install (2) 5 x 45 mm mounting screws. Leave
a 1/4" (6.4 mm) gap between the wall and the back of the
screw head to slide range hood into place.
For wall anchors, install the 10 x 60 mm wall anchors
and install the 5.4 x 75 mm screws into the wall anchors.
Tighten until the wall anchors are secure. Back the screws
out 1/4" (6.4 mm).
Vent Cover Bracket Installation
1. Attach vent cover bracket to wall flush to the ceiling using (2)
5 x 45 mm screws. Use the optional wall anchors if needed.
Complete Preparation
1. Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See “Venting Requirements” section.
2. Determine the required height for the home power supply
cable and drill a 1
1
/
4
" (3.2 cm) hole at this location.
3. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough 1/2" (12.7 mm) conduit
and wires from the fused disconnect (or circuit breaker) box
to make the connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
Vertical Centerline
C
L
LLAW RAER
ETALPMET GNITNUOM
EGDE MOTTOB NGILA
ENIL LICNEP HTIW
MOTTOB GNITACIDNI
DOOH EHT FO
thgieH noitallatsnI
TROPPUS LLAW RAER RO SDUTS HGUORHT SELOH TOLIP "61/3 )OWT( 2 LLIRD
eniL latnoziroH
A
C
B
A. Centerline
B. Fastener locations
C. Mounting height reference (hood bottom line)
¹⁄₄"
(6.4 mm)
A
C
B
A. Ceiling
B. Wall
C. Centerline
8
Install Range Hood
NOTE: Remove protective film from range hood and metal filters.
1. Using two or more people, hang range hood on two
mounting screws through the mounting slots on back of
hood.
2. Remove the grease filter. See “Range Hood Care” section.
3. Level the range hood and tighten upper mounting screws.
4. Install (2) 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
Connect Vent System
1. Install transition on top of hood (if removed for shipping)
with (2) 3.5 x 9.5 mm sheet metal screws.
For vented installations only:
1. Fit vent system over the exhaust outlet.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the duct cover bracket
using (4) 4.2 x 8 mm screws.
2. Measure from the bottom of the air deflector to the bottom
of the hood outlet.
3. Cut the duct to the measured size “X.”
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over
the exhaust outlet from the hood.
7. Reassemble the air deflector to the duct cover
bracket with the four assembly screws.
8. Seal connections with vent clamps.
B
C
A
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
B
A
A. Vent transition
B. 3.5 x 9.5 mm screw
A
B
C
A. Assembly screws
B. Air deflector
C. Duct cover bracket
X
A
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
9
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
a UL Listed or CSA approved 1/2" (12.7 mm) strain relief.
4. Run home power supply cable through strain relief
into terminal box.
5. Use UL Listed wire connectors and connect
black wires (E) together.
6. Use UL Listed wire connectors and connect
white wires (C) together.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL Listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Install Vent Covers
NOTE: Remove protective film from the vent covers.
1. When using both upper and lower vent covers, push lower
cover down onto hood, and then lift upper cover to ceiling
and install with (2) 4.2 x 8 mm screws.
NOTE: For vented installations the upper vent cover
may be reversed to hide slots.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
C
B
A
A. Terminal box
B. Knockout
C. Terminal box cover
A
B
C
D
E
F
G
A. Home power supply cable
B. UL Listed or CSA
approved strain relief
C. UL Listed wire connectors
D. White wires
E. Black wires
F. Green (or bare) and
yellow-green ground wires
G. Terminal box
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
C
A
B
A. Bracket
B. 4.2 x 8 mm screws
C. Vent cover
10
2. Secure the bottom of the duct with (2) 4.2 x 8 mm screws.
Complete Installation
1. For non-vented (recirculating) installations only, install
charcoal filters over metal grease filter. See the “Range
Hood Care” section.
2. Install metal filters. See the “Range Hood Care” section.
3. Check the operation of the range hood blower and light.
See the “Range Hood Use” section.
NOTE: To get the most efficient use from your new range hood,
read the “Range Hood Use” section.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking
vapors, and odors from the cooktop area. For best results,
start the hood before cooking, and allow it to operate several
minutes after the cooking is complete to clear all smoke and
odors from the kitchen.
The hood controls are located on the front side of the canopy.
Range Hood Controls
Operating the light
The On/Off light button controls both lights. Press once
for On and again for Off.
Operating the blower
The Blower Speed buttons turn the blower on and control the
blower speed and sound level for quiet operation. The speed
can be changed anytime during fan operation by pressing the
desired Blower Speed button.
The Blower Off button turns the blower off.
A
B
C
D
F
E
G
A. Duct cover holes
B. Duct cover
C. Control panel
D. Glass canopy
E. Grease filter
F. LED lights
G. Grease filter release handle
A
B
C
D
E
A. Blower speed maximum button
B. Blower speed medium button
C. Blower speed minimum button
D. Blower off button
E. On/Off light button
11
RANGE HOOD CARE
Cleaning
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease
filters before operating hood.
Exterior Surfaces
To avoid damage to the exterior surface, do not use steel wool
or soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water or all-purpose cleanser
Wipe with damp soft cloth or nonabrasive sponge,
and then rinse with clean water and wipe dry.
Metal Grease Filter
1. Remove the filter by pulling the spring release handle
and then pulling down the filter.
2. Wash metal filter as needed in dishwasher or hot
detergent solution.
3. Reinstall the filter by making sure the spring release handles
are toward the front. Insert aluminum filter into upper track.
4. Push in spring release handle.
5. Push up on metal filter and release handle to latch into place.
Non-Vented (recirculating) Installation Filters
The charcoal filter is not washable. It should last up to
6 months with normal use. Replace with Charcoal Filter Kit. See
the “Assistance or Service” section to order.
To replace charcoal filter:
1. Remove metal grease filter from range hood.
See “Metal Grease Filter” in this section.
2. Bend spring clips away from metal grease filter.
3. Place charcoal filter into top side of metal filter.
4. Bend spring clips back into place to secure the
charcoal filter to the metal filter.
5. Replace metal grease filter. See “Metal Grease Filter”
in this section.
Replacing a LED Lamp
The LED lights are replaceable by a service technician only.
See the “Warranty” section for service contact information.
A
A. Spring release handle
12
WIRING DIAGRAM
LN Gnd
WH
Push Button Switch
SEL0115572A
Motor Specifications
Power Supply
Frequency
Power Absorption 240 W
120 VAC
60 Hz
Blue/Black
Blue/Gray
Blue/Red
Blue/White
17.7
27.1
34.6
41.2
Push Button
Switch Operation
POSITIONFUNCTION
Off
Lamps
Low Speed
Med Speed
High Speed
No Connection
YL/GN
WH
BK
YL/GN
WH
WH
WH
WH
BK
BK
BK
BK
BU
BU
BU
BU
BR
BR
BR
YL
YL
YL
YL
RD
RD
RD
BK
BK
BU
EMI Filter
LED
Driver
Brown/Black (L-3)
Blue/Yellow (M-La)
Brown/White (L-1)
Brown/Red (L-2)
YL
GY
Output: 700mA (2-15 VDC)
Input: 120 VAC
Motor Resistance (Ω)
+
-
YL/GN
GY
RD
YL/GN
RD
BU
BU
NOTE: *COMPONENTS AND WIRES DRAWN WITH THE DASHED LINE ARE OPTIONAL.
13
ASSISTANCE OR SERVICE
If You Need Service
Please refer to the warranty page in this manual.
If You Need Replacement Parts
If you need to order replacement parts, we recommend that
you use only factory specified parts. Factory specified parts
will fit right and work right because they are made with the
same precision used to build every new appliance.
To locate factory specified replacement parts in your area,
call the following customer assistance telephone number
or your nearest designated service center.
In the U.S.A.
Call the Whirlpool Customer eXperience Center toll-free:
1-800-253-1301 or visit our website at www.whirlpool.com.
Our Consultants Provide Assistance With:
Scheduling of service. Whirlpool designated service
technicians are trained to fulfill the product warranty and
provide after-warranty service anywhere in the United States.
Features and specifications on our full line of appliances.
Referrals to local dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking,
hearing impaired, limited vision, etc.).
For Further Assistance
If you need further assistance, you can write to Whirlpool
Corporation with any questions or concerns at:
Whirlpool Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
In Canada
Call the Whirlpool Canada Customer eXperience Centre toll-free:
1-800-807-6777, or visit our website at www.whirlpool.ca.
Our Consultants Provide Assistance With:
Scheduling of Service. Whirlpool designated service
technicians are trained to fulfill the product warranty
and provide after-warranty service anywhere in Canada.
Features and specifications on our full line of appliances.
Referrals to local dealers.
Use and maintenance procedures.
Accessory and repair parts sales.
For Further Assistance
If you need further assistance, you can write to Whirlpool
Canada with any questions or concerns at:
Whirlpool Brand Home Appliances
Customer eXperience Centre
200 - 6750 Century Ave.
Mississauga, Ontario L5N 0B7
Please include a daytime phone number in your correspondence.
Accessories
Recirculation Kit
(for non-vented installations only)
Order Part Number W10294733
Charcoal Filter Kit
(for non-vented installations only)
Order Part Number W10412939
Chimney Extension Kit (Stainless Steel)
Order Part Number EXTKIT10ES
Chimney Extension Kit (Black Stainless Steel)
Order Part Number EXTKIT10HV
6" (15.2 cm) Makeup Air Kit
(consult local building codes)
Order Part Number W10446915
14
12/15
WHIRLPOOL
CORPORATION
MAJOR APPLIANCE
LIMITED WARRANTY
ATTACH YOUR RECEIPT HERE. PROOF OF PURCHASE IS REQUIRED
TO OBTAIN WARRANTY SERVICE.
Please have the following information available when you call the
Customer eXperience Center:
Name, address, and telephone number
Model number and serial number
A clear, detailed description of the problem
Proof of purchase including dealer or retailer name and address
IF YOU NEED SERVICE:
1. Before contacting us to arrange service, please determine whether your product requires repair. Some questions
can be addressed without service. Please take a few minutes to review the Troubleshooting or Problem Solver
section of the Use and Care Guide.
2. All warranty service is provided exclusively by our authorized Whirlpool Service Providers. In the U.S. and Canada, direct all requests
for warranty service to:
Whirlpool Customer eXperience Center
In the U.S.A., call 1-800-253-1301. In Canada, call 1-800-807-6777.
If outside the 50 United States and Canada, contact your authorized Whirlpool dealer to determine whether another warranty applies.
ONE YEAR LIMITED WARRANTY
WHAT IS COVERED WHAT IS NOT COVERED
For one year from the date of purchase,
when this major appliance is installed,
operated, and maintained according
to instructions attached to or furnished
with the product, Whirlpool Corporation
or Whirlpool Canada LP (hereafter
“Whirlpool”) will pay for Factory
Specified Replacement Parts and repair
labor to correct defects in materials or
workmanship that existed when this
major appliance was purchased, or at
its sole discretion replace the product.
In the event of product replacement,
your appliance will be warranted for
the remaining term of the original unit’s
warranty period.
YOUR SOLE AND EXCLUSIVE
REMEDY UNDER THIS LIMITED
WARRANTY SHALL BE PRODUCT
REPAIR AS PROVIDED HEREIN.
Service must be provided by a
Whirlpool designated service company.
This limited warranty is valid only
in the United States or Canada and
applies only when the major appliance
is used in the country in which it was
purchased. This limited warranty is
effective from the date of original
consumer purchase. Proof of original
purchase date is required to obtain
service under this limited warranty.
1. Commercial, non-residential, multiple-family use, or use inconsistent with published user,
operator, or installation instructions.
2. In-home instruction on how to use your product.
3. Service to correct improper product maintenance or installation, installation not in accordance
with electrical or plumbing codes, or correction of household electrical or plumbing (i.e. house
wiring, fuses, or water inlet hoses).
4. Consumable parts (i.e. light bulbs, batteries, air or water filters, preservation solutions, etc.).
5. Defects or damage caused by the use of non-genuine Whirlpool parts or accessories.
6. Conversion of your product from natural gas or propane gas or reversal of appliance doors.
7. Damage from accident, misuse, abuse, fire, floods, acts of God, or use with products not
approved by Whirlpool.
8. Repairs to parts or systems to correct product damage or defects caused by unauthorized
service, alteration, or modification of the appliance.
9. Cosmetic damage including scratches, dents, chips, and other damage to appliance finishes
unless such damage results from defects in materials and workmanship and is reported to
Whirlpool within 30 days.
10. Discoloration, rust, or oxidation of surfaces resulting from caustic or corrosive environments,
including but not limited to, high salt concentrations, high moisture or humidity, or exposure to
chemicals.
11. Food or medicine loss due to product failure.
12. Pick-up or delivery. This product is intended for in-home repair.
13. Travel or transportation expenses for service in remote locations where an authorized Whirlpool
servicer is not available.
14. Removal or reinstallation of inaccessible appliances or built-in fixtures (i.e. trim, decorative
panels, flooring, cabinetry, islands, countertops, drywall, etc.) that interfere with servicing,
removal, or replacement of the product.
15. Service or parts for appliances with original model/serial numbers removed, altered, or not
easily determined.
The cost of repair or replacement under these excluded circumstances shall be borne
by the customer.
DISCLAIMER OF IMPLIED WARRANTIES
IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. Some states and provinces do not
allow limitations on the duration of implied warranties of merchantability or fitness, so this limitation may not apply to you. This warranty gives
you specific legal rights, and you also may have other rights that vary from state to state or province to province.
DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY
Whirlpool makes no representations about the quality, durability, or need for service or repair of this major appliance other than the
representations contained in this warranty. If you want a longer or more comprehensive warranty than the limited warranty that comes
with this major appliance, you should ask Whirlpool or your retailer about buying an extended warranty.
LIMITATION OF REMEDIES; EXCLUSION OF INCIDENTAL AND CONSEQUENTIAL DAMAGES
YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN.
WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states and provinces do not allow the
exclusion or limitation of incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives
you specific legal rights, and you also may have other rights that vary from state to state or province to province.
15
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
Avertissements de la proposition 65 de l'État de Californie :
AVERTISSEMENT : Ce produit contient au moins un produit chimique connu par l’État de Californie pour être à l’origine de
cancers.
AVERTISSEMENT : Ce produit contient au moins un produit chimique connu par l’État de Californie pour être à l’origine de
malformations et autres déficiences de naissance.
16
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
LIRE ET CONSERVER CES INSTRUCTIONS
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, RESPECTER LES INSTRUCTIONS
SUIVANTES :
Utiliser cet appareil uniquement dans les applications
envisagées par le fabricant. Pour toute question, contacter
le fabricant.
Avant d'entreprendre un travail d'entretien ou de nettoyage,
interrompre l'alimentation de la hotte au niveau du tableau
de disjoncteurs, et verrouiller le tableau de disjoncteurs
pour empêcher tout rétablissement accidentel de
l'alimentation du circuit. Lorsqu'il n'est pas possible de
verrouiller le tableau de disjoncteurs, placer sur le tableau
de disjoncteurs une étiquette d'avertissement proéminente
interdisant le rétablissement de l'alimentation.
Tout travail d'installation ou câblage électrique doit être
réalisé par une personne qualifiée, dans le respect des
prescriptions de tous les codes et normes applicables, y
compris les codes du bâtiment et de protection contre les
incendies.
Ne pas faire fonctionner un ventilateur dont le cordon ou la
fiche est endommagé(e). Jeter le ventilateur ou le retourner
à un centre de service agréé pour examen et/ou réparation.
Une source d'air de débit suffisant est nécessaire pour le
fonctionnement correct de tout appareil à gaz (combustion
et évacuation des gaz à combustion par la cheminée), pour
qu'il n'y ait pas de reflux des gaz de combustion. Respecter
les directives du fabricant de l'équipement de chauffage et
les prescriptions des normes de sécurité - comme celles
publiées par la National Fire Protection Association (NFPA)
et l'American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), et les prescriptions des
autorités réglementaires locales.
Lors des opérations de découpage et de perçage dans un
mur ou un plafond, ne pas endommager les câblages
électriques et les canalisations qui peuvent s’y trouver.
Les ventilateurs d'évacuation doivent toujours décharger
l'air à l'extérieur.
MISE EN GARDE : Cet appareil est conçu uniquement
pour la ventilation générale. Ne pas l'utiliser pour l'extraction
de matières ou vapeurs dangereuses ou explosives.
MISE EN GARDE :
Pour minimiser le risque d'incendie
et évacuer adéquatement les gaz, veiller à acheminer l'air
aspiré par un conduit jusqu'à l'extérieur - ne pas décharger
l'air aspiré dans un espace vide du bâtiment comme une
cavité murale, un plafond, un grenier, un vide sanitaire ou
un garage.
AVERTISSEMENT :
POUR RÉDUIRE LE RISQUE
D'INCENDIE, UTILISER UNIQUEMENT DES CONDUITS
MÉTALLIQUES.
AVERTISSEMENT : POUR MINIMISER LE RISQUE
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE :
Ne jamais laisser un élément de surface fonctionner à
puissance de chauffage maximale sans surveillance. Un
renversement/débordement de matière graisseuse pourrait
provoquer une inflammation et la génération de fumée.
Utiliser une puissance de chauffage moyenne ou basse
pour le chauffage d'huile.
Veiller à toujours faire fonctionner le ventilateur de la hotte
lors de la cuisson avec une puissance de chauffage élevée
ou lors de la cuisson d'un mets à flamber (à savoir crêpes
Suzette, cerise jubilée, steak au poivre flambé).
Nettoyer fréquemment les ventilateurs d'extraction. Veiller à
ne pas laisser la graisse s'accumuler sur les surfaces du
ventilateur ou des filtres.
Utiliser toujours un ustensile de taille appropriée. Utiliser
toujours un ustensile adapté à la taille de l'élément
chauffant.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE DE
DOMMAGES CORPORELS APRÈS LE DÉCLENCHEMENT
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE, APPLIQUER
LES RECOMMANDATIONS SUIVANTES :
a
Placer sur le récipient un couvercle bien ajusté, une tôle à
biscuits ou un plateau métallique POUR ÉTOUFFER LES
FLAMMES, puis éteindre le brûleur. VEILLER À ÉVITER
LES BRÛLURES. Si les flammes ne s'éteignent pas
immédiatement, ÉVACUER LA PIÈCE ET APPELER LES
POMPIERS.
NE JAMAIS PRENDRE EN MAIN UN RÉCIPIENT
ENFLAMMÉ - vous risquez de vous brûler.
NE PAS UTILISER D'EAU, ni un torchon humide - ceci
pourrait provoquer une explosion de vapeur brûlante.
Utiliser un extincteur SEULEMENT si :
– Il s'agit d'un extincteur de classe ABC, dont on connaît le
fonctionnement.
– Il s'agit d'un petit feu encore limité à l'endroit où il s'est
déclaré.
– Les pompiers ont été contactés.
– Il est possible de garder le dos orienté vers une sortie
pendant l'opération de lutte contre le feu.
a
Recommandations tirées des conseils de sécurité en cas
d'incendie de cuisine publiés par la NFPA.
AVERTISSEMENT : Pour réduire le risque d'incendie
ou de choc électrique, ne pas utiliser ce ventilateur avec un
quelconque dispositif de réglage de la vitesse à semi-
conducteurs.
17
EXIGENCES D’INSTALLATION
Outils et pièces
Rassembler les outils et pièces nécessaires avant d’entreprendre
l’installation. Lire et observer les instructions fournies avec
chacun des outils de la liste ci-dessous.
Outils nécessaires
Niveau
Perceuse avec forets de 1
1
/
4
" (3,2 cm), 1/8" (3,2 mm),
et 5/16" (7,9 mm)
Crayon
Pince à dénuder ou couteau utilitaire
Mètre-ruban ou règle
Pince
Pistolet à calfeutrage et composé de calfeutrage
résistant aux intempéries
Brides de conduit
Scie sauteuse ou scie à guichet
Tournevis à lame plate
Cisaille de ferblantier
Tournevis Phillips
Pièces nécessaires
Câble d’alimentation électrique du domicile
Serre-câble de 1/2" (12,7 mm) (homologation UL ou CSA)
Trois connecteurs de fils homologués UL
Pour les installations avec décharge à l’extérieur,
il vous faudra aussi :
Un bouche de décharge (décharge à travers le mur
ou à travers le toit)
Circuit d’évacuation métallique
Pour les installations sans décharge à l’extérieur (recyclage),
il faudra aussi :
Ensemble de recyclage - Voir la section “Assistance ou
service” pour commander.
Conduit d'évacuation métallique circulaire de 6" (15,2 cm)
de diamètre - longueur déterminée par la hauteur de plafond.
Pièces fournies
Retirer les pièces de leur emballage. Vérifier que toutes
les pièces sont présentes.
Hotte avec ventilateur, lampes DEL et auvent
en verre préinstallés.
Raccord de transition avec clapets anti-reflux installés
Bride de support du cache-conduit
Filtre à graisse métallique
Gabarit de montage
Cache-conduit - 2 pièces
Deux vis de montage de 3,5 x 9,5 mm (Phillips)
Quatre vis de 4,2 x 8 mm (embout de tournevis T20
®†
)
Six vis de montage de 5 x 45 mm (Phillips n° 2)
Quatre vis de 5,4 x 75 mm (Phillips) (pour chevilles d’ancrage
de 10 x 60 mm)
Deux chevilles d’ancrage de 8 x 40 mm
Quatre chevilles d’ancrage de 10 x 60 mm
Adaptateur T20
®†
Torx
®†
Exigences d’emplacement
IMPORTANT : Observer les dispositions de tous les codes
et règlements en vigueur.
Confier l'installation de la hotte à un technicien qualifié.
C'est à l'installateur qu'incombe la responsabilité de respecter
les distances de séparation spécifiées sur la plaque signalétique
de l'appareil. La plaque signalétique de l'appareil est située
derrière le filtre de gauche, sur la paroi arrière de la hotte.
On doit toujours installer la hotte à distance des sources
de courant d’air (fenêtres, portes et bouches de chauffage).
Respecter les dimensions indiquées pour les ouvertures
à découper dans les placards. Ces dimensions tiennent
compte des valeurs minimales des dégagements de séparation.
Il est recommandé d'utiliser cette hotte avec une table de
cuisson dont la puissance totale ne dépasse pas 65 000 BTU.
Une prise de courant électrique reliée à la terre est nécessaire.
Voir la section “Spécifications électriques”.
La hotte est configurée à l’usine pour une décharge à travers le
toit ou un mur. Pour une installation sans décharge à l’extérieur
(recyclage), voir “Installations sans décharge à l'extérieur
(recyclage) uniquement”, à la section “Raccordement du circuit
d'évacuation”. L’ensemble de recyclage est disponible chez
votre marchand ou chez un distributeur de pièces autorisé. Voir
la section “Assistance ou service” pour commander.
On doit assurer l’étanchéité au niveau de chaque ouverture
découpée dans le plafond ou un mur traversé par l’équipement
de la hotte.
Installation dans une résidence mobile
L’installation de cette hotte doit satisfaire aux exigences de
la norme Manufactured Home Construction Safety Standards,
Titre 24 CFR, partie 328 (anciennement Federal Standard for
Mobile Home Construction and Safety, titre 24, HUD, partie
280); lorsque cette norme n’est pas applicable, l’installation
doit satisfaire aux critères de la plus récente édition de la
norme Manufactured Home Installation 1982 (Manufactured
Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A,
ou des codes locaux.
Dimensions du produit
20"
(50,8 cm)
30" (76,2 cm) ou
36" (91,4 cm)
13³⁄₁₆"
(33,5 cm)
10
⁷⁄₈
"
(27,6 cm)
®
TORX et T20 sont des marques déposées de Acument Intellectual Properties, LLC.
18
* Pour installations sans décharge à l'extérieur (recyclage)
** Pour installations avec décharge à l'extérieur
Dimensions du placard
* Installations sans décharge à l'extérieur (recyclage)
IMPORTANT :
Valeur minimale de la distance “X” : 24" (61 cm)
à partir de la surface de cuisson électrique
Valeur minimale de la distance “X” : 27" (68,6 cm)
à partir de la surface de cuisson au gaz.
Valeur maximale suggérée pour la distance
“X” : 36" (91,4 cm)
Les cache-conduits peuvent être adaptés à différentes hauteurs
de plafond. Voir le tableau suivant.
Installations avec décharge à l’extérieur
Hauteur minimale
sous plafond
Hauteur maximale
sous plafond
Surface de
cuisson électrique
7' 4" (2,23 m) 9' 5" (2,87 m)
Surface de
cuisson à gaz
7' 7" (2,31 m) 9' 5" (2,87 m)
Installations sans décharge à l’extérieur (recyclage)
Hauteur minimale
sous plafond
Hauteur maximale
sous plafond
Surface de
cuisson électrique
7' 4" (2,23 m) 9' 9" (2,97 m)
Surface de
cuisson à gaz
7' 7" (2,31 m) 9' 9" (2,97 m)
REMARQUE : Les cache-conduits de hotte sont réglables;
on peut les ajuster en fonction de la hauteur disponible
sous plafond ou soffite, selon la distance “X” entre le bas
de la hotte et la surface de cuisson. Pour des plafonds
de hauteur supérieure, un ensemble d’extension de cache-
conduit peut être acheté auprès de votre revendeur ou d’un
distributeur de pièces autorisé. L’extension de cache-conduit
remplace la section supérieure de cache-conduit fournie avec la
hotte. Voir la section “Assistance ou service” pour commander.
Exigences concernant l’évacuation
(seulement pour un modèle
avecdéchargeàl'extérieur)
Le circuit d'évacuation doit décharger l'air à l'extérieur,
excepté pour une installation sans décharge à l'extérieur
(recyclage).
Ne pas terminer le circuit d'évacuation dans un grenier
ou dans un autre espace fermé.
Ne pas utiliser une bouche de décharge murale de
4" (10,2 cm) normalement utilisée pour un équipement
de buanderie.
Utiliser uniquement des conduits métalliques.
Des conduits en métal rigide sont recommandés.
Ne pas utiliser de conduit de plastique ou en aluminium.
La longueur du circuit d'évacuation et le nombre
de coudes doivent être réduits au minimum pour
fournir la meilleure performance.
Pour un fonctionnement efficace et silencieux :
Ne pas utiliser plus de trois coudes à 90°.
Veiller à ce qu'il y ait une section droite de conduit
de 24" (61 cm) ou plus entre les coudes, si on doit
utiliser plus d’un raccord coudé.
Ne pas connecter deux coudes ensemble.
Au niveau de chaque jointure du circuit d'évacuation,
assurer l'étanchéité avec les brides de serrage.
Le circuit d'évacuation doit comporter un clapet anti-
reflux. Si la bouche de décharge murale ou par le toit
comporte un clapet, ne pas utiliser le clapet fourni
avec la hotte d'extraction.
Assurer l'étanchéité avec un composé de calfeutrage
autour de la bouche de décharge à l'extérieur (mur ou toit).
La taille du conduit doit être uniforme.
17
³⁄₁₆" (43,7 cm)
**27¹⁄₈" (68,9 cm) min.
**41¹⁄₈
" (104,5 cm) max.
*27¹⁄₈" (68,9 cm) min.
*45¹⁄₂" (115,6 cm) max.
10" (25,4 cm) min.
13" (33,0 cm) max.
9¹⁄₂" (24,1 cm)
2" (5,1 cm) min.
9" (22,9 cm) min.*
Axe central
Placard
adjacent
Placard
adjacent
Point d'entrée
du circuit
d'évacuation
et du câble
d'alimentation
électrique
20" (50,8 cm)* min.
30" (76,2 cm) ou
36" (91,4 cm)
Distance “X”
entre le bas de
l'auvent et
la surface
de cuisson
10" (25,4 cm) min.
13" (33,0 cm) max.
Surface de cuisson
19
Installation dans une région à climat froid
On doit installer un clapet anti-reflux additionnel pour
minimiser le reflux d'air froid, et incorporer un élément
d'isolation thermique pour minimiser la perte de chaleur
par conduction par l'intermédiaire du conduit d'évacuation,
de l'intérieur de la maison à l'extérieur. Le clapet anti-reflux
doit être placé du côté froid par rapport à l'élément
d'isolation thermique.
L'élément d'isolation thermique doit être aussi proche
que possible de l'endroit où le circuit d'évacuation
pénètre la partie chauffée de la maison.
Air d'appoint
Le code du bâtiment local peut exiger l'emploi d'un système
de renouvellement de l'air/introduction d'air d'appoint, lors
de l'utilisation d'un système d'aspiration de débit supérieur
à une valeur (pieds cubes par minute) spécifiée. Le débit
spécifié, pieds cubes par minute, est variable d'une juridiction
à une autre. Consulter un professionnel des installations de
chauffage ventilation/climatisation au sujet des exigences
spécifiques applicables dans la juridiction locale.
Méthodes d’évacuation
Cette hotte a été configurée à l'usine pour la décharge
de l'air aspiré à travers le toit ou à travers un mur.
Un circuit d'évacuation en conduit rond de 6" (15,2 cm)
(non fourni) est nécessaire pour l'installation. La hotte
comporte une ouverture de sortie de diamètre 6" (15,2 cm).
REMARQUE : On déconseille l'emploi de conduit flexible.
Un conduit flexible peut causer une rétropression et des
turbulences de l'air, ce qui réduit considérablement la
performance.
La sortie à l'extérieur du circuit d'évacuation peut se faire
à travers le toit ou à travers un mur. Pour la sortie à travers
un mur, on doit employer un raccord coudé (90°).
Décharge par l'arrière
Le raccord coudé à 90° peut être installé immédiatement
au-dessus de la hotte.
Installation sans décharge à l'extérieur (recyclage)
S'il n'est pas possible d'évacuer les fumées et vapeurs de
cuisson à l'extérieur, on peut employer la version installation
sans décharge à l'extérieur (recyclage) de la hotte, dotée
d'un filtre à charbon et du déflecteur. Les vapeurs/fumées
sont alors recyclées à travers la grille supérieure.
Calcul de la longueur effective
du circuit d'évacuation
Pour calculer la longueur effective du circuit d'évacuation
nécessaire, additionner les longueurs équivalentes (pieds/
mètres) de tous les composants utilisés dans le système.
Composants du
circuit d'évacuation
Conduit 6" (15,2 cm) de diamètre
Coude à 45° 2,5 pi (0,8 m)
Coude à 90° 5 pi (1,5 m)
La longueur équivalente maximum est de 35 pi (10,7 cm).
Exemple de circuit d'évacuation
Dans l'exemple suivant, la longueur théorique du circuit est
inférieure au maximum recommandé de 35 pi (10,7 m).
1 coude à 90° = 5 pi (1,5 m)
1 bouche de décharge murale = 0 pi (0 m)
Section droite de 8 pi (2,4 m) = 8 pi (2,4 m)
Longueur du système = 13 pi (3,9 m)
Installation
sans décharge
à l'extérieur
(r
ecyclage)
Décharge à
travers le mur
Décharge à
travers le toit
A
A
B
B
B
A
A. Déflecteur
B. Conduit rond
de 6" (15,2 cm)
A. Bouche de
décharge murale
B. Conduit rond de
6" (15,2 cm)
A. Bouche de
décharge sur toit
B. Conduit rond de
6" (15,2 cm)
Coude à 90˚
6 pi (1,8 m)
2 pi
(0,6 m)
Bouche de
décharge m
urale
20
Spécications électriques
Observer les dispositions de tous les codes et règlements
en vigueur.
S'assurer que l’installation électrique est correcte et qu'elle
satisfait aux exigences de la plus récente édition de la norme
National Electrical Code, ANSI/NFPA 70, ou de la norme CSA
C22. 1-94, Code canadien de l’électricité, partie 1 et C22.2
n° 0-M91 (dernière édition) et de tous les codes et règlements
en vigueur.
Si les codes le permettent et si l'on utilise un conducteur distinct
de liaison à la terre, il est recommandé qu'un électricien qualifié
vérifie la qualité de la liaison à la terre.
Pour obtenir un exemplaire des normes des codes ci-dessus,
contacter :
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
L'appareil doit être alimenté par un circuit de 120 V
CA seulement, 60 Hz, 15 ampères, protégé par fusible.
Si le domicile possède un câblage en aluminium, suivre
la procédure ci-dessous :
1. Raccorder une section de câble en cuivre massif
aux conducteurs en queue de cochon.
2. Connecter le câblage en aluminium à la section ajoutée
de câblage en cuivre en utilisant des connecteurs et/ou
des outils spécialement conçus et homologués UL pour
fixer le cuivre à l’aluminium.
Suivre la procédure recommandée par le fabricant de
connecteurs électriques. Les raccordements aluminium/
cuivre doivent satisfaire aux prescriptions des codes
locaux et de l’industrie, et être conformes aux pratiques
de câblage reconnues.
Le calibre des conducteurs et les connexions doivent
être compatibles avec les caractéristiques électriques
de l'appareil spécifiées sur la plaque signalétique.
La plaque signalétique de l'appareil est située derrière
le filtre, sur la paroi arrière de la hotte.
Le calibre des conducteurs doit être conforme aux exigences
du National Electrical Code, de la plus récente édition
de la norme ANSI/NFPA 70 ou des normes CSA C22. 1-94,
Code canadien de l'électricité, partie 1 et C22.2 n° 0-M91
(édition la plus récente) et de tous les codes et règlements
en vigueur.
INSTRUCTIONS D’INSTALLATION
Préparation de l’emplacement
Il est recommandé d’installer le circuit d’évacuation
avant de procéder à l’installation de la hotte.
Avant d’exécuter les découpages, vérifier la disponibilité
d’un dégagement suffisant dans le plafond ou le mur
pour le conduit d’évacuation.
Avant de sélectionner la hotte à installer, mesurer
la hauteur libre sous plafond et la hauteur maximum
disponible sous la hotte.
1. Déconnecter la source de courant électrique.
2. Déterminer la méthode d’évacuation à utiliser :
décharge à travers le mur ou le toit, ou recyclage.
3. Sélectionner une surface plane pour l’assemblage de la
hotte. Placer le matériau de protection sur cette surface.
4. À l’aide de deux personnes ou plus, soulever la hotte
et la poser sur la surface couverte.
5. Ôter la base en bois de la hotte de cuisine et jeter
de façon convenable.
6. Retirer le filtre à graisse en métal et le matériau d’expédition
en mousse se trouvant sous le ventilateur, à l’intérieur de la
hotte de cuisine.
Installation des vis de montage de la hotte
1. Déterminer et marquer la position de l’axe central
sur le mur où la hotte sera installée.
2. Sélectionner une hauteur de montage comprise entre
un minimum de 24" (61 cm) pour une surface de cuisson
électrique, un minimum de 27" (68,6 cm) pour une surface
de cuisson au gaz et un maximum suggéré de 36" (91,4 cm)
entre le dessus de la cuisinière et le bas de la hotte.
Marquer la ligne de repérage sur le mur.
3. Fixer le gabarit en place avec du ruban adhésif; aligner
l’axe central du gabarit et le bas du gabarit avec la ligne
correspondant au bas de la hotte, et avec l’axe central
déjà tracé sur le mur.
4. À l’aide du gabarit, marquer sur le mur le centre
des attaches.
IMPORTANT : Toutes les vis de montage de la hotte
en îlot doivent être vissées dans du bois où cela est
possible. Si l'on ne peut pas visser les vis de montage
de la hotte dans du bois, des tasseaux supplémentaires
pour accrochage mural seront peut-être nécessaires,
ou utiliser quatre chevilles d’ancrage de 10 x 60 mm
et vis de 5,4 x 75 mm.
Retirer le gabarit.
AVERTISSEMENT
Risque du poids excessif
Utiliser deux ou plus de personnes pour déplacer et
installer la hotte de la cuisinière.
Le non-respect de cette instruction peut causer
une blessure au dos ou d'autre blessure.
Vertical Centerline
C
L
LLAW RAER
ETALPMET GNITNUOM
EGDE MOTTOB NGILA
ENIL LICNEP HTIW
MOTTOB GNITACIDNI
DOOH EHT FO
thgieH noitallatsnI
TROPPUS LLAW RAER RO SDUTS HGUORHT SELOH TOLIP "61/3 )OWT( 2 LLIRD
eniL latnoziroH
A
C
B
A. Axe central
B. Emplacements des attaches
C. Ligne de référence pour la hauteur
de montage (bas de la hotte)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Whirlpool WVW51UC0HV Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues