Tetra Contour Flex Guide d'installation

Taper
Guide d'installation
Installation Guide
SIGN299 | DOC-2001572
2424
Volt
EN
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
For the latest North American install guides for your product go to: https://products.LED.com/led-signage-lighting
For the latest European install guides for your product go to: https://products.LED.com/eu/led-signage-lighting
RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY
IN ACCORDANCE WITH KIT INSTRUCTIONS.
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED
BY THE INSTRUCTIONS ARE PRESENT.
TROUSSE DE CONVERSION À DEL POUR LA
MODERNISATION DES ENSEIGNES
À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.
BG Българската версия на инструкциите за инсталаця и
информация за безопасност могат да бъдат намерени
на следния адрес: https://products.LED.com/eu/led-
signage-lighting
CS Návod k montáží a bezpečnostní informace v češtině
najdete zde: https://products.LED.com/eu/led-signage-
lighting
DA Den danske version af installationsvejledningen og
sikkerhedsoplysninger kan findes på følgende placering:
https://products.LED.com/eu/led-signage-lighting
DE Die deutsche Version der Installationsanleitung und
Sicherheitsinformationen finden Sie in folgendem Verzeic:
https://products.LED.com/eu/led-signage-lighting
EL Μπορείτε να βρείτε την ελληνική εκδχή των οδηγιών
νγκατάστασης και των πληροφοριών ασφάλειας στην
εξής τοποθεσία: https://products.LED.com/eu/led-
signage-lighting
ES La versión española de las instrucciones de instalación y
la información sobre seguridad puede encontrarse en la
siguiente ubicación: https://products.LED.com/eu/led-
signage-lighting
ET Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate
aadressilt: https://products.LED.com/eu/led-signage-
lighting
FI Asennusohjeiden ja turvallisuustietojen suomenkielinen
versio löytyy seuraavasta paikasta: https://products.LED.
com/eu/led-signage-lighting
FR La version française des instructions d’installations et
information de sécurité est disponible à l’adresse suivante:
https://products.LED.com/eu/led-signage-lighting
HR Hrvatska verzija priručnika za ugradnju i sigurnosnih
informacija nalazi se na sljedečoj lokaciji: https://products.
LED.com/eu/led-signage-lighting
HU A telepítési útmutató és a biztnosági információk magyar
nyelvű változata az alábbi címen található: https://
products.LED.com/eu/led-signage-lighting
IT La versione italiana del manuale di installazione e
sicurezza può essere reperita nella seguente sezione:
https://products.LED.com/eu/led-signage-lighting
LT Lietuvišką diegimo instrukcijos ir saugos informacijos
versiją galima rasti šioje vietoje: https://products.LED.
com/eu/led-signage-lighting
LV Uzstādīšanas instrukciju un drošības informāciju latviešu
valodā var atrast šeit: https://products.LED.com/eu/led-
signage-lighting
NL De Nederlandse versie van de installatie-instructies en
veiligheidsinformatie kan op de volgende locatie worden
gevonden: https://products.LED.com/eu/led-signage-
lighting
PL Polską wersję instrukcji instalacji oraz informacje
dotyczące bezpieczeństwa można znaleźć w następującej
lokalizacji: https://products.LED.com/eu/led-signage-
lighting
PT A versão em Português das instruções de instalação e
das informações de segurança pode ser encontrada na
seguinte localização: https://products.LED.com/eu/led-
signage-lighting
RO Versiunea în limba română a instrucţiunilor de instalare
şi a informaţiilor de siguranţă pot fi găsite la: https://
products.LED.com/eu/led-signage-lighting
SV Ni hittar den svenska versionen av
installationsanvisningarna och säkerhetsinformationen på
följande plats: https://products.LED.com/eu/led-signage-
lighting
SL Previdnostna opozorila in varnostne informacije so na
zadnji strani vodnika za namestitev. Pred začetkom
namestitve izdelka jih skrbno preberite: https://products.
LED.com/eu/led-signage-lighting
SK Slovenskú verziu montažnej príručky a bezpečnostnŷch
instrukcií nájdete na nasledujúcej lokalite: https://
products.LED.com/eu/led-signage-lighting
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Prepare Electrical Wiring
Electrical Requirements
Acceptable to use in dry, damp, and wet locations when installed
correctly.
The grounding and bonding of the LED Driver shall be done in
accordance with National Electric Code (NEC) Article 600.
Follow all National Electric Codes (NEC) and local codes.
These products are only suitable for connection to a circuit from
a Class 2 power source. These products have not been evaluated
for use when connected to a power source that does not comply
with Class 2 voltage and energy limited supplies.
FOR UL ONLY
Contour Gen 2 Flex
LED Lighting System
Side Bend
GEXNFS32-1, GEXNFS65-1, GEXNFSRD-1,
GEXNFSGL-1, GEXNFSBL-1, GEXNFSYG-1,
GEXNFSRC-1
Contour Gen 2 Flex (Side Bend) Installation Guide
2
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power off before inspection, installation or removal.
Properly ground power supply enclosure.
Not to be submerged or used in a marine environment.
RISK OF FIRE
Use only suitably approved wire for input/output
connections. Minimum size 18 AWG (0.82mm2)
Follow all local codes.
Waterproof wire connection for outdoor or wet
installations. See instructions for details.
Do not stretch light engines.
Inspect and replace the light engines if any tear or
damage affects their integrity.
Avoid installation that leads to prolonged exposure to
standing water or ice.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
Assurez-vous de correctement mettre à terre l’alimentation électrique.
Ne pas submerger ou installer dans un environnement marin
RISQUES D’INCENDIE
N’utilisez que des fils approuvés par UL pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82mm2)
Respectez tous les codes locaux.
Étanchéifier les connexions électriques effectuées à l’extérieur
ou pour un environnement exposé à l’eau. Voir les instructions
d’installation pour plus de détails.
Ne pas étirer les modules DEL Contour.
Inspecter l’intégrité des modules DEL Contour et les remplacer s’ils
sont déchirés ou endommagés.
Éviter les installations avec une exposition prolongée à l’eau
stagnante ou à la glace.
UL WARNING / AVERTISSEMENT UL
RISK OF FIRE OR ELECTRIC SHOCK
LED Retrofit Kit installation requires knowledge of
sign electrical systems. If not qualified, do not attempt
installation. Contact a qualified electrician.
Install this kit only in host signs that have been
identified in the installation instructions and where the
input rating of the retrofit kit does not exceed the input
rating of the sign.
Installation of this LED retrofit kit may involve drilling or
punching of holes into the structure of the sign. Check
for enclosed wiring andcomponents to avoid damage to
wiring and electrical parts.
Do not make or alter any open holes in an enclosure of
wiring or electrical components during kit installation.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE
L’installation de l’équipement de remplacement DEL exige Ia
connaissance des systèmes électriques pour enseignes. Si non qualifié, ne
tentez pas d’installation. Veuillez contacter un électricien qualifié.
Risque d’incendie ou de choc électrique. Installez cet ensemble seulement
dans des enseignes hôtes qui ont été identifiés dans les instructions
d’installation et dont la capacité d’entrée de l’ensemble ne dépasse pas la
capacité d’entrée de l’enseigne.
L’installation de cet équipement de remplacement DEL peut impliquer le
perçage ou le poinçonnage de trous dans la structure du panneau Vérifiez
le câblage et les composants inclus pour éviter d’endommager le câblage
et les composants électriques.
Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage
ou de composants électriques pendant l’installation de cet équipement
de remplacement DEL.
CAUTION / ATTENTION
RISK OF INJURY
While performing installations described, gloves, safety
glasses or goggles should be worn.
RISQUE DE BLESSURE
Lors de l’exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
Contour Gen 2 Flex (Side Bend) Installation Guide
3
Components and Tools Required
12
3 4 5 6 7 8 9 10
Contour Gen 2 Flex Side Bend Light Engine
GEXNFRL-1 Flex Rail or GEDSRLXX-3 Tetra SNAP Rail
GEXNFMC-1 Flex Mounting Clip
#6, #8 or #10 (M2, M3 or M4) self-drilling pan headed screws
#6 (M2) screws
Minimum 22 AWG (0.33mm2) tie-wire
24 Volt power supply
UL approved 18 AWG (0.82mm2) supply wire
UL approved 22-14 AWG (0.33-2.08mm2) twist-on wire connectors
GEXNFEC-1 Flex End Cap
Electrical grade silicone.
Examples of electrical grade silicone:
Momentive RTV 6702 (white) / RTV 6708 (clear) - Silicone Rubber Adhesive Sealant
Momentive RTV 162 (White) - Silicone Rubber Adhesive Sealant-Electrical Grade
Dow Corning 3140 (clear) - Non-Corrosive Flowable
Dow Corning 3145 (clear or gray) - Non-Corrosive Non-flowable
Dow Corning RTV 748 (white) - Non-Corrosive Sealant
Cutting Resolution Table
Light Engine Color Cutting Resolution
Red, Red-Orange,
Amber,Green, Blue, White 4 in. (101.6 mm)
1
2
Weather box GEXNWB2
Contour Light Guide connector
Contour Light Guide 90° inside corner
Contour Light Guide 90° outside corner
Contour Light Guide 90° planar corner
Optional / Required for Wet Locations
Optional
12
13
14
16
15
3
4
5
6
7
8
9
10
11
11 16
12 13 14 15
100” (2.54 m) 95.4” (2.42 m)
Contour Gen 2 Flex (Side Bend) Installation Guide
4
4.5 in. (114 mm)
Mount the Flex rails so that
they are gapped at least
4.5 in. (114 mm) apart if end
to end, using a #6 or #8
(M2 or M3) screw at least
every 2 ft. of rail but not less
than 2 screws per rail.
NOTE: For an 8 ft. rail
length, there will be 2.08 in.
(52.8 mm) of excess light
engine on each end.
Using the Flex Rail final length,
measure out the necessary
length of Contour LED light
engine so that it will extend
at least 3/4 in. (19 mm). If
required, use a sharp cutting
tool to cut through light engine
(refer to the Cutting Resolution
Table on page 2).
Installation
Plan the layout by measuring the design
layout and dividing by 8 ft . (2.44m)
to determine the required quantity of
Contour Gen 2 Flex. Refer to the Cutting
Resolution Table on page 3 when
cutting any Contour Gen 2 Flex section.
Do not use more than one suffix
code for each respective application,
as mixing suffix codes may result in
appearance variation. Suffix code can
be found on the packaging label.
NOTE: If mounting surfaces are rough or uneven, take the necessary precautions to avoid bending the rail when
mounting.
If you have any questions about these instructions or your specific Contour application, please contact support at
Planning First
METHOD A - Installing Light Engines With GEXNFRL-1 Flex Rail
- Straight Runs Only
1 2 For cut end, fill cap with
electrical grade silicone and
push cap on the end to seal.
Clean excess silicone.
3
Electrical grade
silicone
Cut on marks only
Contour Gen 2 Flex (Side Bend) Installation Guide
5
Cut end
at top
Uncut
end at
bottom Fill end cap with
silicone and install
Insert wire connectors into
weather box. Fill with electrical
grade silicone and close box.
Weather box can be mounted
using #8 (M3) screws.
Weather box
can be painted
+
To connect two light engines,
first strip wire ends back
0.5 in. (13mm). Then join wires
together using twist-on wire
connectors.
WARNING / AVERTISSEMENT
RISK OF FIRE: Waterproof wire connection and all cut ends for outdoor or wet installations. Weather box is required for all outdoor
or wet locations electrical connections.
RISQUE D’INCENDIE: Étanchéifier les connexions électriques et sceller l’extrémité des sections coupées effectuées à l’extérieur ou
pour un environnement exposé à l’eau. Un boitier étanche est requis pour les connexions électriques effectuées à l’extérieur ou
dans un environnement avec exposition à l’eau.
6 7
For vertical or near vertical
installations, any cut-end
termination of a Contour
piece shall reside at the
top of the design.
5
WARNING/AVERTISSEMENT
RISK OF FIRE: The light engine is not intended for excessive or repetitive bending or
stretching. If the silicone does crack, replace the light engine.
RISQUE D’INCENDIE: Les modules DEL Contour ne sont pas conçus pour des pliages
excessifs, répétitifs ou pour être étirés. Si le silicone montre des signes de craquement,
remplacer le module DEL Contour.
Push the light engine segments
down into the Flex Rail.
4
Electrical grade
silicone
Electrical
grade
silicone
Linear: At each gap
between sections, apply
silicone on both sides
to secure light guide
connector. Snap on a light
guide connector.
Corner: For all corners (planar,
inside, outside) apply silicone
on both sides to secure light
guide corners. Snap on corner.
Follow Steps 8-9 if wires are cut.
Joining with Light Guide Connectors, Corners and Bends
Do not
bend one
light into a
corner
8 9
Contour Gen 2 Flex (Side Bend) Installation Guide
6
6-12 in.
(152-305 mm)
Plan the layout by measuring the design
layout and dividing by 8 ft . (2.44 m)
to determine the required quantity
of Contour Gen 2 Flex. Refer to the
Cutting Resolution Table on page 3
when cutting any Contour Gen 2 Flex
section.
Do not use more than one suffix
code for each respective application,
as mixing suffix codes may result in
appearance variation. Suffix code can
be found on the packaging label.
DO NOT bend the light engine to an inside radius that is tighter than 1 in. (25.4 mm).
If you have questions about these instructions or your Contour application,
contact support at [email protected]
Planning First
METHOD B - Installing Light Engines With GEXNFMC-1 Flex Mounting Clip
Install a Flex Mounting Clip,
using #6 (M2) counter sink
screws, every 6-12 inches
(152-305 mm) on center until
the end of the run is reached.
Installation
Using the light engine final
length, measure out the
necessary length of Contour
light engine so that it will
extend at least 3/4 in. (19 mm)
past the last mounting clip. If
required, use a sharp cutting
tool to cut through light engine.
For cut end, fill cap with
electrical grade silicone and
push end cap on the end to
seal. Clean excess silicone.
1 2 3
WARNING / AVERTISSEMENT
RISK OF FIRE: DO NOT bend the light engine to an inside radius that is tighter than 1 in. (25.4 mm).
RISQUE D’INCENDIE: Ne pas plier les modules DEL Contour avec un rayon de courbure inférieur à 1 pouce (25.4 mm).
Back bendSide bend
Cut on marks only Electrical grade
silicone
Contour Gen 2 Flex (Side Bend) Installation Guide
7
Push into clips
Insert wire connectors
into weather box. Fill with
electrical grade silicone and
close box.
Secure the weather box using
a #6 or #8 (M2 or M3) screw.
Power
supply
Red (+)
Black or blue (–)
To Contour
Strip wires back 0.5 in. (13mm).
Connect the red wire (+)
from the LED strip to the red
wire (+) of the power supply.
Connect the black wire (-)
from the LED strip to the black
or blue wire (-) of the power
supply.Grounding and bonding
must be done in accordance
with National Electrical Code
(Article 600). See power supply
instructions.
Run a wire from the power
supply to a section of Contour.
Power supply connection
to the AC mains must be
completed in an acceptable
enclosure. Power supply
loading is described on
page 9.
Connect Power Supply
WARNING/AVERTISSEMENT
RISK OF ELECTRICAL SHOCK: Turn power OFF before inspection, installation or removal.
RISQUES DE CHOC ÉLECTRIQUE: Coupez l’alimentation électrique avant d’inspecter, d’installer ou de déplacer le luminaire.
8
11
910
To power supply
Red (+)
Black or
blue (–)
Weather box can be painted
Push each light
engine segment
into the clips.
4Insert wire connectors
into weather box. Fill
with electrical grade
silicone and close
box. Weather box can
be mounted using #8
(M3) screws.
To connect two
light engines, first
strip wire ends back
0.5 in. (13mm). Then
join wires together
using twist-on wire
connectors.
Secure light engine
by twisting tie-wire
around the mounting
clip and light engine.
65 7
Weather
box can be
painted
+
Contour Gen 2 Flex (Side Bend) Installation Guide
8
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside
and outside the building. Ensure that the branch circuit supplying the existing transformer or ballast will be within
the voltage ratings of the new LED power supply, and have a current rating not exceeding 20A, or that permitted by
applicable local, state, or country electrical codes (whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent
tubes; and associated transformers and ballasts. Care should be taken not to break the existing neon or fluorescent
tubes. NOTE: Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers
and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by
applicable local, state, or country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm
(1/2-in) diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller
openings may be sealed with non-hardening caulk.
5. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
6. A 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Determine the number of Power
Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload the Power
Supply chosen.
7. Follow Method A, B or C to mount the Contour Gen 2 Flex.
8. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
9. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and
the instructions found in the power supply installation guide.
10. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state,
and country electrical codes.
Retrofit Instructions
Troubleshooting
Symptom Condition Solution
All LEDs are OFF
No AC input. Attach AC input and/or check circuit breaker.
Incorrect wire attachment.
Check wire connection(s) at the Contour Gen 2 Flex LED light
engine and power supply for improper connections or short
circuits. Make sure you have positive to positive and negative to
negative wire connections.
Some LEDs
appear dim
Overload (maximum load exceeded).
Ensure the overall length of Contour LED Gen 2 Flex light engine
does not exceed the maximum load as detailed in the Tetra
Power Supply Installation Instructions.
Maximum recommended supply wire
length exceeded.
Reduce the length of supply wire equal to or below the
recommended maximum.
Mixed Suffix Codes of LED light
engine within an application.
Make sure that all LED light engines have the same Suffix Code
(Suffix Code is located on each packaging label).
Some of the
sections are not
illuminated
Incorrect wire attachment.
Check the wire connections at the Contour Gen 2 Flex LED light
engine for improper connections. Make sure you have positive
to positive and negative to negative wire connections. Check for
improper cutting resolution locations (see table on Page 2).
Light/dark banding
along a section
LED light engine flexed in the wrong
direction or smaller than the minimum
bend radius during installation.
Remove LED light engine and properly install.
Inspect and replace light engine if damaged.
Contour Gen 2 Flex (Side Bend) Installation Guide
NOTE: For linear long runs, center connection to the LED strip is recommended to minimize voltage drop.
*GELP24-60U-GL minimum load = 15 ft. (4.57 m).
**GEPS24V50-100W minimum load = 36 ft. (10.97 m).
Maximum Loading per 24 VDC Class 2 Power Supply
Power Supply
GEXNFS32-1, GEXNFS65-1, GEXNFSRD-1, GEXNFSGL-1,
GEXNFSBL-1, GEXNFSYG-1, GEXNFSRC-1
Rating per module 24VDC, 1.4W/ft. (Strip)
GEPS24-25U-NA, GEPS24-25-EU (CE only)
Load shall not exceed 0.83A 15ft. (4.57 m)
GEPS24D-60U-GLX, *GELP24-60U-GL
Load shall not exceed 2.5A 39 ft. (11.88 m)
GEPS24D-80U
Load shall not exceed 3.3A 49ft. (14.93 m)
GEPS24-100U-GLX, GEPS24D-100U-NA, GEPS24LT-100U-NA,
USVI-100024FE, USVI-100024FBA
Load shall not exceed 4.0A
59ft. (17.98 m)
GEPS24-100U-GLX2, GEPS24-100U-TT, **GEPS24V50-100W
Load shall not exceed 4.0A 62ft. (18.89 m)
GEPS24-200U-GLX2
Load shall not exceed 4.0A per each (of 2) output channels
62ft. (18.89 m) per bank
124 ft. (37.78 m) per PS
GEPS24-300U-GLX2
Load shall not exceed 4.0A per each (of 3) output channels
62ft. (18.89 m) per bank
186 ft. (56.67 m) per PS
This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.
Conforms to the following standards:
Dismantling
At the end of life, the contained LED light source may be cut out using suitable wire cutters, removed from the mounting surface,
then replaced per the cutting and installation instructions above, or dismantled and taken to a communal collecting point for
environmentally friendly disposal in accordance with local regulations by a professional installer.
Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly
disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable.
Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.
Power Supply
Wattage
18 AWG/0.82 mm2
Supply Wire
16 AWG/1.31 mm2
Supply Wire
14 AWG/2.08 mm2
Supply Wire
12 AWG/3.31 mm2
Supply Wire
25W 20 ft./6.1 m –––
60W, 80W, 100W,
180W, 200W, 300W 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
Maximum Remote Mounting Distance from Driver Ouput
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 9 of 9
(Rev 06/20/23)
SIGN299 | DOC-2001572
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Tetra Contour Flex Guide d'installation

Taper
Guide d'installation

dans d''autres langues