Grandstream GHP610-W Compact Hotel Phone Guide d'installation

Catégorie
Téléphones IP
Taper
Guide d'installation
GHP610/W
GHP611/W
Compact Hotel Phone
Quick Installation Guide
Grandstream Networks, Inc.
126 Brookline Ave, 3rd Floor
Boston, MA 02215. USA
Tel : +1 (617) 566 - 9300
Fax: +1 (617) 249 - 1987
www.grandstream.com
For Certication, Warranty and RMA information, please visit
www.grandstream.com
Content
English............................................................................1
~ 1 ~ ~ 2 ~
PACKAGE CONTENT
PRECAUTIONS
WARNING: Please DO NOT power cycle the GHP610/W
and GHP611/W during system boot up or rmware upgrade.
You may corrupt rmware images and cause the unit to
malfunction.
WARNING: Use only the power adapter included in the
GHP610/GHP611 package. Using an alternative non-quali-
ed power adapter may possibly damage the unit.
1x Base 1x Handset 1x Phone Cord
1x Quick Installation
Guide
The GHP610/W and GHP611/W are not pre-cong-
ured to support or carry emergency calls to any type
of hospital, law enforcement agency, medical care unit
(“Emergency Service(s)”) or any other kind of Emergency
Service. You must make additional arrangements to
access Emergency Services. It is your responsibility
to purchase SIP-compliant Internet telephone service,
properly congure the GHP610/W GHP611/W to use that
service, and periodically test your conguration to conrm
that it works as you expect. If you do not do so, it is your
responsibility to purchase traditional wireless or landline
telephone services to access Emergency Services.
GRANDSTREAM DOES NOT PROVIDE CON-
NECTIONS TO EMERGENCY SERVICES VIA THE
GHP610/W AND THE GHP611/W. NEITHER GRAND-
STREAM NOR ITS OFFICERS, EMPLOYEES OR
AFFILIATES MAY BE HELD LIABLE FOR ANY CLAIM,
DAMAGE, OR LOSS. YOU HEREBY WAIVE ANY AND
ALL SUCH CLAIMS OR CAUSES OF ACTION ARISING
FROM OR RELATING TO YOUR INABILITY TO USE
THE GHP610/W AND GHP611/W TO CONTACT
EMERGENCY SERVICES, AND YOUR FAILURE TO
MAKE ADDITIONAL ARRANGEMENTS TO ACCESS
EMERGENCY SERVICES IN ACCORDANCE WITH
THE IMMEDIATELY PRECEDING PARAGRAPH.
The GNU GPL license terms are incorporated into the
device rmware and can be accessed via the Web user
interface of the device at http(s)://IP/gpl_license.
To obtain a CD with GPL source code information please
submit a written request to [email protected]
EN
OVERVIEW
The GHP61X is a delicate IP Phone featuring one HD
speaker on handset, 2 SIP accounts/lines, 3 program-
mable keys and 10 speed dial keys. It also support
Wi-Fi (GHP610W/GHP611W), 3-way voice conferenc-
ing, using full band Opus voice codec and advanced
jitter-resilience algorithm that tolerate up to 30% packet
loss without impacting voice quality. The GHP61X series
is supported by Grandstream’s Device Management
System (GDMS), which provides a centralized interface
to congure, provision, manage and monitor deployments
of Grandstream endpoints. And it suitable for GDS37xx
door control function. GHP61X series IP phone can be
installed on desktop or wall-mounted, and can be powered
by PoE (GHP610/GHP611) or power adapter (GHP610W/
GHP611W). Its elegant and compact design make it perfect
for not only hotels, but also hospital, apartments, dormito-
ries and much more.
12V
1x 12V Power Adapter
(Only with GHP610W and GHP611W)
~ 3 ~ ~ 4 ~
GHP610/W & GHP611/W DESCRIPTION
WALL MOUNT
Wall
mount
slots
Wall
mount
slots
100mm
PHONE CONFIGURATION
1. Connect the handset (RJ-11 port) and the base with the
phone cord.
2. Connect the LAN port of the phone to the RJ-45 socket
of a hub/switch or a router (LAN side of the router)
using the Ethernet cable. This step can be skipped, if
using GHP610W & GHP611W with Wi-Fi.
Mark two dots horizontally with
100 mm in between where to
wall mount the GHP610/W &
GHP611/W.
Using a drill, make a hole on
each marked dot. Put a plastic
expansion bolt and screw (not
provided) on each hole. Leave
enough space on the screws
to mount the GHP610/W &
GHP611/W.
Mount the GHP610/W &
GHP611/W on the screws using
its “Wall Mount Slots”.
Note: For easy deployment, the GHP610W/GHP611W is
out of the box precongured to connect to a default SSID
named wp_master with a password (WPA/WPA2 PSK)
equal to wp!987@dmin, users can adapt these settings
from the web UI as well to make it easier for deployment
on customer site.
1. Ensure your phone is powered up and connected to the
Internet.
2. Locate the MAC address on the MAC tag of the unit,
which is on the underside of the device, or on the
package.
3. From a computer connected to same network as the
GHP61X, type in following address using GHP61X’s
MAC address on your browser: https://<mac>.local
Example: https://3765dcc282.local
Note: The user can also dial **47# and the IP address
will be read by the IVR.
4. Enter admin’s username and password to access the
conguration menu. (The factory default username
is “admin” while the default random password can be
found on the sticker at the back of the unit).
Refer to online documents and FAQ for more detailed
information: https://www.grandstream.com/our-products
Earphone
Services Label
Flash
Volume Down Key
Softkeys
Redial
Microphone
Alphanumeric
Keypad
LED Indicator
Volume Up Key
Hold
Speaker
Magnetic Hook
RJ-11 Port
Mute
Voicemail
CONNECTING THE PHONE
To setup the phone, follow the steps below:
3. Powering the phone:
For GHP610W & GHP611W: Connect the 12V DC
output plug to the power jack on the phone; plug the
power adapter into an electrical outlet.
For GHP610 & GHP611: A PoE switch must be used
in step 2.
For certification information, please refer to User Manuals:
http://www.grandstream.com
U.S. FCC Part 68 Regulatory Information
This equipment complies with Part 68 of the FCC rules. Located on the
equipment is a label that contains, among other information, the ACTA
registration number and ringer equivalence number (REN.) If requested, this
information must be provided to the telephone company.
The REN is used to determine the quantity of devices which may be connected
to the telephone line. Excessive RENs on the telephone line may result in the
devices not ringing in response to an incoming call. In most, but not all areas,
the sum of the RENs should not exceed five (5.0). To be certain of the number
of devices that may be connected to the line, as determined by the total RENs
contact the telephone company to determine the maximum REN for the calling
area.
This equipment cannot be used on the telephone company-provided coin
service. Connection to Party Line Service is subject to State Tariffs.
If this equipment causes harm to the telephone network, the telephone
company will notify you in advance that temporary discontinuance of service
may be required. If advance notice isnt practical, the telephone company will
notify the customer as soon as possible. Also, you will be advised of your right
the file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment,
operations, or procedures that could affect the operation of the equipment. If
this happens, the telephone company will provide advance notice in order for
you to make the necessary modifications in order to maintain uninterrupted
service.
If the trouble is causing harm to the telephone network, the telephone
company may request you to remove the equipment from the network until
the problem is resolved.
This equipment uses the following USOC jacks: RJ45C.
It is recommended that the customer install an AC surge arrester in the AC
outlet to which this device is connected. This is to avoid damaging the
equipment caused by local lightening strikes and other electrical surges.
If trouble is experienced with this equipment, please contact (Agent in the US):
Company Name: Grandstream Networks, Inc.
Address: 126 Brookline Ave, 3rd Floor Boston, MA 02215, USA
Tel: 1-617-5669300
Fax: 1-617-2491987
U.S. FCC Part 15 Regulatory Information
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:(1) this device may not cause harmful interference,
and(2) this device must accept any interference received, including interference
that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Canada Regulatory Information
This product meets the applicable Innovation, Science and Economic
Development Canada technical specifications.
The Ringer Equivalence Number (REN) indicates the maximum number of
devices allowed to be connected to a telephone interface. The termination of
an interface may consist of any combination of devices subject only to the
requirement that the sum of the RENs of all the devices not exceed five.
Ce produit répond à la innovation, des sciences et de Développement
économique Canada spécifications techniques applicables.
Le nombre équivalent de sonneries (REN) indique le nombre maximal de
terminaux qui peuvent être raccordés à une interface téléphonique. La
terminaison d'une interface peut consister en une combinaison de dispositifs, à
la seule condition que la somme des REN de tous les dispositifs ne dépasse pas
cinq.
EU Regulatory Information
Hereby, [Grandstream Networks, Inc.] declares that the radio equipment type
[GHP611GHP610] is in compliance with Directive 2014/30/EU.
The full text of the EU declaration of conformity is available at the following
internet address: www.grandstream.com
UK Regulatory Information
Hereby, [Grandstream Networks, Inc.] declares that the radio equipment
type [GHP611GHP610] is in compliance with Directive UK SI 2016 No. 1091
The full text of the UK declaration of conformity is available at the following
internet address: www.grandstream.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Grandstream GHP610-W Compact Hotel Phone Guide d'installation

Catégorie
Téléphones IP
Taper
Guide d'installation