Hubbell Wiring Device-Kellems PD2621 Guide d'installation

Taper
Guide d'installation
Installation Instructions
English
®
PD2621 (Page 1) PRINTED IN USA 05/14
Wiring Device-Kellems
Hubbell Incorporated (Delaware)
40 Waterview Drive
Shelton, Connecticut 06484
1-800-288-6000
2 INCH HUB AND KO PLATE FOR
2, 4, and 6 GANG CFB FLOOR BOXES
Applies to Catalog No.’s CFBHUB2, CFBKOPLATE, and CFBKOPLATECR
CAUTION: RISK OF ELECTRIC SHOCK. Disconnect power before installing or servicing.
NOTICE: For installation by a quali ed electrician in accordance with national and local electrical codes,
communication standards, the following instructions, and any instruction included with individual devices.
NOTICE: Ensure data/communications circuits are separated from lighting/power circuits in accordance
NEC® and CE code requirements.
CFBHUB2 2”Hub for use with CFB2G30, CFB2G30CR, CFB2G30R, CFB2G30RCR, CFB4G30, CFB4G-
30CR, CFB4G30R, CFB4G30RCR, CFB6G30, CFB6G30CR, CFB6G30R, and CFB6G30RCR series oor
boxes.
CFBKOPLATE KO plate for use with CFB2G30, CFB2G30R, CFB4G30, CFB4G30R, CFB6G30, CFB-
6G30R and series oor boxes.
CFBKOPLATECR corrosion resistant ko plate for use with CFB2G30CR, CFB2G30RCR, CFB4G30CR,
CFB4G30RCR, CFB6G30CR, and CFB6G30RCR corrosion resistant series oor boxes.
CAUTION: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING.
See Figures for CFBHUB2 and CFBKOPLATExx installation.
2” HUB Metallic
Catalog No. CFBHUB2 KO Plates Metallic
Catalog No. CFBKOPLATE
Catalog No. CFBKOPLATECR
Figure 1 Figure 2
PD2621 (Page 2) PRINTED IN USA 05/14
1. Assemble KO plate Catalog No.
CFBKOPLATE [1] to box Catalog No.
CFB2G30xx [2] using four #10-32 x
7/16”length screws [4] (provided).
Tighten screws to 15-20 in.lbs [1.69-
2.25 N•m] of torque.
Assembly installation CFBKOPLATE KO plate:
1
2
3
2. Assemble 2 in. Hub Catalog No. CFBHUB2
[4] to box Catalog No. CFB2G30xx [5]
using four #10-32 x 7/16”length screws [6]
(provided).
Tighten screws to 15-20 in.lbs [1.69-
2.25 N•m] of torque.
Figure 3
Assembly installation CFBHUB2 2” Hub:
4
5
6
Figure 4
Directives de montage
®
PD2621 (Page 1) PRINTED IN USA 05/14
Wiring Device-Kellems
Hubbell Incorporated (Delaware)
40 Waterview Drive
Shelton, Connecticut 06484
1-800-288-6000
Français
RACCORD DE 5 cm ET PLAQUE AVEC DÉBOUCHURES POUR
BOÎTES DE PLANCHER CFB À 2, 4 ET 6 COMPARTIMENTS
Relatif aux numéros de catalogue CFBHUB2, CFBKOPLATE et CFBKOPLATECR
ATTENTION - RISQUE DE CHOC ÉLECTRIQUE. Débrancher le circuit avant de procéder au montage.
AVIS - Doit être installé par un électricien quali é conformément aux codes de l’électricité nationaux et locaux,
les normes de communication, les directives qui suivent et toutes directives incluses avec les dispositifs
individuels.
AVIS – S’assurer que les circuits de données/communication sont séparés des circuits d’éclairage/d’énergie
selon les exigences du Code canadien de l’électricité.
Utiliser le raccord CFBHUB2 de 5 cm avec les boîtes de plancher des séries CFB2G30, CFB2G30CR, CFB-
2G30R, CFB2G30RCR, CFB4G30, CFB4G30CR, CFB4G30R, CFB4G30RCR, CFB6G30, CFB6G30CR,
CFB6G30R et CFB6G30RCR.
Utiliser les plaques avec débouchures CFBKOPLATE avec les boîtes de plancher des séries CFB2G30,
CFB2G30R, CFB4G30, CFB4G30R, CFB6G30 et CFB6G30R.
Utiliser les plaques avec débouchures anticorrosion CFBKOPLATECR avec les boîtes de plancher anticorro-
sion des séries CFB2G30CR, CFB2G30RCR, CFB4G30CR, CFB4G30RCR, CFB6G30CR et CFB6G30RCR.
ATTENTION - LIRE TOUTES LES DIRECTIVES AVANT D’ENTREPRENDRE LES TRAVAUX.
Consulter les gures pour l’installation des éléments CFBHUB2 et CFBKOPLATExx.
Raccord métallique de 5 cm
No catalogue CFBHUB2 Plaque métallique avec débouchures
No catalogue CFBKOPLATE
No catalogue CFBKOPLATECR
Figure 1 Figure 2
PD2621 (Page 2) PRINTED IN USA 05/14
1. Joindre la plaque de débouchures nº de
catalogue CFBKOPLATE [1] à la boîte nº de
catalogue CFB2G30xx [2] à l’aide des quatre
vis nº 10-32 x 11 mm [4] (fournies).
Serrer les vis à une couple de 1,69-2,25 N•m.
Montage de la plaque de débouchures CFBKOPLATE
1
2
3
2. Joindre le raccord de 5 cm nº de catalogue
CFBHUB2 [4] à la boîte nº de catalogue
CFB2G30xx [5] à l’aide des quatre vis nº 10-
32 x 11 mm [6] (fournies).
Serrer les vis à une couple de 1,69-2,25 N•m.
Figure 3
Montage du raccord CFBHUB2 de 5 cm
4
5
6
Figure 4
Instrucciones de instalación
®
PD2621 (Page 1) PRINTED IN USA 05/14
Wiring Device-Kellems
Hubbell Incorporated (Delaware)
40 Waterview Drive
Shelton, Connecticut 06484
1-800-288-6000
Español
CONECTOR DE 5 cm Y PLACA DE DISCOS REMOVIBLES
PARA CAJAS DE PISO CFB DE 2, 4 Y 6 COMPARTIMENTOS
Corresponde a catálogo CFBHUB2, CFBKOPLATE y CFBKOPLATECR
¡CUIDADO! - RIESGO DE ELECTROCUCIÓN. Desconectar la corriente antes de proceder a la instalación o
el mantenimiento.
AVISO - Para ser instalada por un electricista calicado de acuerdo con los códigos eléctricos nacionales
y locales, las normas de comunicación, las siguientes instrucciones, y cualquier instrucción incluida con
dispositivos individuales.
AVISO - Asegurarse de que los circuitos de datos/comunicaciones estén separados de los circuitos de
iluminación/energía según las exigencias de la la Norma ocial mexicana NOM-001-SEDE.
Usar el conector CFBHUB2 de 5 cm con las cajas de piso series CFB2G30, CFB2G30CR, CFB2G30R,
CFB2G30RCR, CFB4G30, CFB4G30CR, CFB4G30R, CFB4G30RCR, CFB6G30, CFB6G30CR,
CFB6G30R y CFB6G30RCR.
Usar las placas de discos removibles CFBKOPLATE con las cajas de piso series CFB2G30, CFB2G30R,
CFB4G30, CFB4G30R, CFB6G30 y CFB6G30R.
Usar las placas de discos removibles resistentes a la corrosión CFBKOPLATECR con las cajas de
piso resistentes a la corrosión des séries CFB2G30CR, CFB2G30RCR, CFB4G30CR, CFB4G30RCR,
CFB6G30CR et CFB6G30RCR.
¡CUIDADO! - LEER TODAS LAS INSTRUCCIONES ANTES DE COMENZAR LOS TRABAJOS.
Ver guras para la instalación de CFBHUB2 y CFBKOPLATExx.
Conector metálico de 5 cm
Núm. catálogo CFBHUB2
Placa metálica de discos removibles
Núm. catálogo CFBKOPLATE
Núm. catálogo CFBKOPLATECR
Figura 1 Figura 2
PD2621 (Page 2) PRINTED IN USA 05/14
1. Unir la placa de discos removibles catálogo
CFBKOPLATE (1) a la caja de piso ca-
tálogo Nº CFB2G30xx [2] usando los cuatro
tornillos #10-32 x 11 mm [4] (incluidos).
Ajustar los tornillos con un par de 1,69-2,25 N•m.
Instalación de placa de discos removibles CFBKOPLATE
1
2
3
2. Unir el conector de 5 cm catálogo Nº
CFBHUB2 [4] a la caja de piso catálogo Nº
CFB2G30xx [5] usando los cuatro tornillos
#10-32 x 11 mm [4] (incluidos).
Ajustar los tornillos con un par de 1,69-2,25 N•m.
Figura 3
Instalación del conector CFBHUB2 de 5 cm
4
5
6
Figura 4
HUBBELL DE MÉXICO garantiza este producto, de estar libre de defectos en materiales y mano
de obra por un año a partir de su compra. Hubbell reparará o reemplazará el artículo a su juicio
en un plazo de 60 días. Esta garantía no cubre desgastes por uso normal o daños ocasionados
por accidente, mal uso, abuso o negligencia. El vendedor no otorga otras garantías y excluye
expresamente daños incidentales o consecuenciales inherentes a su uso.
HUBBELL DE MÉXlCO, S.A. de C.V.
Av. Insurgentes Sur # 1228 Piso 8 Tel.:(55) 9151 - 9999
Col. Tlacoquemecatl del Valle
México, 03200 D.F.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Hubbell Wiring Device-Kellems PD2621 Guide d'installation

Taper
Guide d'installation