Competent persons
Connection, mounting, commissioning and adjustment of the device must only be
carried out by competent persons.
Prerequisites for competent persons:
– They have a suitable technical education.
– They are familiar with the rules and regulations for occupational safety and
safety at work.
– They are familiar with the operating instructions for the device.
– They have been instructed by the responsible person on the mounting and
operation of the device.
Certified electricians
Electrical work must be carried out by a certified electrician.
Due to their technical training, knowledge and experience as well as their familiar-
ity with relevant standards and regulations, certified electricians are able to per-
form work on electrical systems and independently detect possible dangers.
In Germany, certified electricians must fulfill the requirements of accident-preven-
tion regulations DGUV (German Social Accident Insurance) provision 3 (e.g. elec-
trician foreman). In other countries, there are respective regulations that must be
observed.
Disclaimer
LeuzeelectronicGmbH+Co.KG is not liable in the following cases:
– The device is not being used properly.
– Reasonably foreseeable misuse is not taken into account.
– Mounting and electrical connection are not properly performed.
– Changes (e.g., constructional) are made to the device.
Overview
With the CU405-2M12 connection unit, you can connect an RSL 410 safety sen-
sor to corresponding fieldbus modules using an
M12 cable with safety function for
safe electronic switching devices with OSSD in the device (self-monitoring)
– in
accordance with AIDA specifications.
The
MELD
non-safe signal output of the RSL 410 is accessible via a second M12
connection. It is electrically isolated via a relay.
ETH M12 socket, 4-pin, D-coded
Ethernet communication connection, M12 connection for functional earth
X1 M12 plug, 4-pin, A-coded
Connection of
M12 cable with safety function for safe electronic switching
devices with OSSD in the device (self-monitoring)
in accordance with AIDA
specifications.
X2 M12 plug, 4-pin, A-coded
Connection of M12 cable for connecting the
MELD
output signal (electri-
cally isolated signal output)
12