Dell PowerEdge 2970 Guide de démarrage rapide

Taper
Guide de démarrage rapide
www.dell.com | support.dell.com
Rack Installation Guide
Guide d'installation du rack
Rack-Installationsanleitung
ラック取り付けガイド
Guía de instalación del rack
Rack Installation Guide
Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid
the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
____________________
Information in this document is subject to change without notice.
© 2007 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, RapidRails, and VersaRails are trademarks of Dell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
March 2007 P/N TP579 Rev. A00
Contents 3
Contents
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SAFETY: Rack Mounting of Systems
. . . . . . . . . . . . . . . . . . . . . 5
General Installation Instructions
. . . . . . . . . . . . . . . . . . . . . . . . . 6
Before You Begin
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Important Safety Information
. . . . . . . . . . . . . . . . . . . . . . . . . 6
Rack Requirements for VersaRails
. . . . . . . . . . . . . . . . . . . . . . 6
Rack Stabilizer Feet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Recommended Tools and Supplies
. . . . . . . . . . . . . . . . . . . . . . 7
Rack Kit Contents
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation Tasks
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Removing the Rack Doors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Marking the Rack
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Configuring the Sliding Rail Assemblies
. . . . . . . . . . . . . . . . . . . . 11
Installing the Mounting Rails in the Rack
. . . . . . . . . . . . . . . . . . . . 12
Installing RapidRails Mounting Rails
. . . . . . . . . . . . . . . . . . . . 12
Installing the VersaRails Mounting Rails
. . . . . . . . . . . . . . . . . . 13
Installing the System in the Rack
. . . . . . . . . . . . . . . . . . . . . . . . 15
Removing the System From the Rack
. . . . . . . . . . . . . . . . . . . . 16
Installing the Cable-Management Arm
. . . . . . . . . . . . . . . . . . . . . 17
Routing Cables
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Attaching the Cable-Management Arm Ramp Assembly
. . . . . . . . . . . . 19
Replacing the Rack Doors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4 Contents
Rack Installation Guide 5
Safety Instructions
Use the following safety guidelines to ensure your own personal safety and to help protect your system
and working environment from potential damage. For complete safety and regulatory information, see
the Product Information Guide that shipped with your system. Warranty information might be included
in this document or as a separate document.
SAFETY: Rack Mounting of Systems
Observe the following precautions for rack stability and safety. Also refer to the rack installation
documentation accompanying the system and the rack for specific caution statements and procedures.
Systems are considered to be components in a rack. Thus, "component" refers to any system as well as
to various peripherals or supporting hardware.
CAUTION: Before installing systems in a rack, install front and side stabilizers on stand-alone racks or the front
stabilizer on racks joined to other racks. Failure to install stabilizers accordingly before installing systems in
a rack could cause the rack to tip over, potentially resulting in bodily injury under certain circumstances.
Therefore, always install the stabilizer(s) before installing components in the rack.
After installing system/components in a rack, never pull more than one component out of the rack on its slide
assemblies at one time. The weight of more than one extended component could cause the rack to tip over and
may result in serious injury.
NOTE: Your system is safety-certified as a free-standing unit and as a component for use in a Dell rack cabinet
using the customer rack kit. The installation of your system and rack kit in any other rack cabinet has not been
approved by any safety agencies. It is your responsibility to ensure that the final combination of system and rack
complies with all applicable safety standards and local electric code requirements. Dell disclaims all liability and
warranties in connection with such combinations.
System rack kits are intended to be installed in a rack by trained service technicians. If you install
the kit in any other rack, be sure that the rack meets the specifications of a Dell rack.
CAUTION: Do not move racks by yourself. Due to the height and weight of the rack, a minimum of two people
should accomplish this task.
Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor,
and that the full weight of the rack rests on the floor. Install front and side stabilizers on a single rack
or front stabilizers for joined multiple racks before working on the rack.
Always load the rack from the bottom up, and load the heaviest item in the rack first.
Make sure that the rack is level and stable before extending a component from the rack.
Use caution when pressing the component rail release latches and sliding a component into or out of
a rack; the slide rails can pinch your fingers.
Do not overload the AC supply branch circuit that provides power to the rack. The total rack load
should not exceed 80 percent of the branch circuit rating.
Ensure that proper airflow is provided to components in the rack.
Do not step on or stand on any component when servicing other components in a rack.
6 Rack Installation Guide
General Installation Instructions
This installation guide provides instructions for trained service technicians installing one or more systems in
a rack cabinet. The RapidRails™ configuration can be installed without tools in manufacturer's rack cabinets
that have square holes; the VersaRails™ configuration can be installed in most industry-standard rack
cabinets that have square or round holes. One rack kit is required for each system to be installed in the rack
cabinet.
Before You Begin
Before you begin installing your system in the rack, carefully read "Safety Instructions" on page 5, as well
as the safety instructions found in your Product Information Guide for additional information.
CAUTION: When installing multiple systems in a rack, complete all of the procedures for the current system
before attempting to install the next system.
CAUTION: Rack cabinets can be extremely heavy and move easily on their casters. They do not have brakes. Use
extreme caution while moving the rack cabinet. Retract the leveling feet when relocating the rack cabinet. Avoid
long or steep inclines or ramps where loss of cabinet control may occur. Extend the leveling feet for support and
to prevent the cabinet from rolling.
NOTE: For instructions on installing the system itself, see "Installing the System in the Rack" on page 15.
Important Safety Information
Observe the safety precautions in the following subsections when installing your system in the rack.
CAUTION: You must strictly follow the procedures in this document to protect yourself as well as others who
may be involved. Your system may be very large and heavy and proper preparation and planning are important to
prevent injury to yourself and to others. This precaution becomes increasingly important when systems are
installed high up in the rack.
CAUTION: Do not install rack kit components designed for another system. Use only the rack kit for your system.
Using the rack kit for another system may result in damage to the system and personal injury to yourself and to
others.
Rack Requirements for VersaRails
NOTICE: The VersaRails rack kit is intended to be installed by trained service technicians in a rack that meets the
specifications of American National Standards Institute (ANSI)/Electronic Industries Association (EIA) standard
ANSI/EIA-310-D-92, International Electrotechnical Commission (IEC) 297, and Deutsche Industrie Norm (DIN) 41494.
One rack kit is required for each system that is installed in a rack.
Rack Installation Guide 7
Rack Stabilizer Feet
CAUTION: Before installing systems in a rack, install front and side stabilizers on stand-alone racks or the front
stabilizer on racks joined to other racks. Failure to install stabilizers accordingly before installing systems in a
rack could cause the rack to tip over, potentially resulting in bodily injury under certain circumstances.
Therefore, always install the stabilizer(s) before installing components in the rack.
The stabilizer feet help prevent the rack from tipping over. See the documentation provided with the rack
cabinet for instructions on installing and anchoring the stabilizer feet.
Recommended Tools and Supplies
You may need the following items to install the system in a four-post rack cabinet:
#2 Phillips screwdriver
Masking tape or a felt-tip pen, for use in marking the mounting holes to be used
Rack Kit Contents
One pair of slide assemblies
One cable-management arm
One left cable-management arm ramp assembly
One right cable-management arm ramp assembly
One status indicator cable (if applicable)
Eight 10-32 x 0.5-inch flange-head Phillips screws
NOTE: The nonmetric screws described in illustrations and in procedural steps are identified by size and number
of threads per inch. For example, a #10 Phillips-head screw with 32 threads per inch is identified as a 10-32 screw.
NOTE: Both the right and left cable-management arm ramp assemblies are illustrated in Figure 1-1. Depending on
the orientation of the cable-management arm (CMA), you will only use one ramp assembly to secure the CMA to
the back of the rack. For more information, see "Attaching the Cable-Management Arm Ramp Assembly"
on page 19.
8 Rack Installation Guide
Figure 1-1. Rack Kit Contents
Installation Tasks
Installing a rack kit involves performing the following tasks (described in detail in subsequent sections)
in their numbered order:
1
Removing the rack doors
2
Marking the rack
3
Configuring the sliding rail assemblies
4
Installing the mounting rails in the rack
RapidRails installation
VersaRails installation
5
Installing the system in the rack
6
Installing the cable-management arm
7
Routing cables
8
Attaching the cable-management arm ramp assembly
9
Replacing the rack doors
1 cable-management arm 2 left cable-management arm
ramp assembly
3 right cable-management arm
ramp assembly
4 slide assemblies 5 10-32 x 0.5-inch flange-head
Phillips screws (8)
6 status indicator cable
(if applicable)
5
1
6
4
2
3
Rack Installation Guide 9
Removing the Rack Doors
See the procedures for removing doors in the documentation provided with your rack cabinet.
CAUTION: Because of the size and weight of the rack cabinet doors, never attempt to remove or install them
by yourself.
CAUTION: Store the doors where they will not injure someone if the doors accidently fall over.
Marking the Rack
For a 2-U system, you must allow 2 U (88 mm, or 3.5 inches) of vertical space for each system you install
in the rack.
Rack cabinets that meet EIA-310 standards have an alternating pattern of three holes per rack unit with
center-to-center hole spacing (beginning at the top hole of a 1-U space) of 15.9 mm, 15.9 mm, and 12.7 mm
(0.625 inch, 0.625 inch, and 0.5 inch) for the front and back vertical rails (see Figure 1-2). Rack cabinets may
have round or square holes.
NOTE: The vertical rails may be marked by horizontal lines and numbers in 1-U increments. If you want, you can
make a note of the number marking on the rack’s vertical rail. It is not necessary to mark or place tape on the rack.
Figure 1-2. One Rack Unit
CAUTION: If you are installing more than one system, install the mounting rails so that the first system
is installed in the lowest available position in the rack.
1 U (44 mm [1.75 inches])
12.7 mm (0.5 inch)
15.9 mm (0.625 inch)
15.9 mm (0.625 inch)
12.7 mm (0.5 inch)
10 Rack Installation Guide
To mark the rack, perform the following steps:
1
Place a mark (or tape) on the rack's front vertical rails where you want to locate the bottom of the
system you are installing in the rack. The bottom of each 1-U space is at the middle of the narrowest
metal area between holes (marked with a horizontal line on some rack cabinets—see Figure 1-3).
2
Place a mark 88 mm (3.5 inches) above the original mark you made (or count up three holes in a rack
that meets EIA-310 standards) and mark the rack's front vertical rails with a felt-tipped pen or masking
tape (if you counted holes, place a mark just above the top hole). This mark or piece of tape indicates
where the system's upper edge will be located on the vertical rails (see Figure 1-3).
Figure 1-3. Marking the Vertical Rails
1 marks on vertical rail (2)
1
Rack Installation Guide 11
Configuring the Sliding Rail Assemblies
The sliding rail assembly has a rotating mounting bracket at each end of the rail. The position of the
bracket determines whether the rail assembly is used as a RapidRail or a VersaRail. The RapidRail side of
the bracket has a hook and a latch that secure it to the vertical rail. The VersaRail side of the bracket has
three holes and uses screws to attach it to the vertical rail.
NOTE: The rack kit ships with the slide assemblies in the RapidRails configuration.
To change from one type of rail assembly to the other type of rail assembly:
1
Lift the blue lever on the rotating mounting bracket (see Figure 1-4).
2
Rotate the bracket and slide it up off of the two shoulder standoffs.
3
Continue to rotate the bracket 180 degrees until you can set the notches back over the shoulder
standoffs.
4
Rotate the bracket in the opposite direction until the bracket clicks into place.
Figure 1-4. Changing the Position of the Rotating Mounting Bracket
1 mounting-bracket flange
(RapidRails version shown)
2 rotating bracket 3 release lever
4 shoulder standoffs (2) 5 notches (2)
1
4
3
5
2
12 Rack Installation Guide
Installing the Mounting Rails in the Rack
Installing RapidRails Mounting Rails
NOTE: Ensure that the rotating mounting brackets on the slide assemblies are in the RapidRail configuration.
See Figure 1-5.
1
At the front of the rack cabinet, position one of the mounting rails so that its mounting-bracket flange
fits between the marks or tape you placed (or numbered locations) on the vertical rails in "Marking the
Rack" on page 9 (see Figure 1-5).
The top mounting hook on the front mounting-bracket flange should enter the top hole between
the marks you made on the vertical rails.
Figure 1-5. Installing RapidRails Mounting Rails
1 mounting hooks (4) 2 push buttons (2) 3 mounting rails (2)
front of rack
1
2
3
Rack Installation Guide 13
2
Push the mounting rail forward until the mounting hooks enter their square holes, and then push
down on the mounting-bracket flange until the mounting hooks seat and the push button pops out
and clicks (see Figure 1-5).
3
At the back of the cabinet, pull back on the mounting-bracket flange until the mounting hooks enter
their square holes, and then push down on the flange until the mounting hooks seat and the push
button pops out and clicks.
4
Repeat step 1 through step 3 for the mounting rail on the other side of the rack.
NOTE: Ensure that the mounting rails are mounted at the same vertical position on both sides of the rack.
Installing the VersaRails Mounting Rails
NOTE: Ensure that the rotating mounting brackets on the slide assemblies are in the VersaRail configuration.
See Figure 1-6.
1
At the front of the rack cabinet, position one of the mounting rails so that its mounting-bracket flange
fits between the marks you placed (or numbered locations) on the vertical rails in "Marking the Rack"
on page 9 (see Figure 1-6).
The three holes on the front of the mounting-bracket flange should align with the holes between the
marks you made on the front vertical rail.
2
Install two 10-32 x 0.5-inch flange-head Phillips screws in the upper and lower holes in the mounting-
bracket flange to secure the mounting rail to the front vertical rail.
3
At the back of the cabinet, pull back on the mounting-bracket flange until the mounting holes align
with their respective holes on the back vertical rail.
4
Install two 10-32 x 0.5-inch flange-head Phillips screws in the upper and lower holes in the mounting-
bracket flange to secure the mounting rail to the back vertical rail.
5
Repeat step 1 through step 4 for the mounting rail on the other side of the rack.
NOTE: Ensure that the mounting rails are mounted at the same position on the vertical rails on each side
of the rack.
14 Rack Installation Guide
Figure 1-6. Installing VersaRails Mounting Rails
1 mounting-bracket flange 2 10-32 x 0.5-inch flange-head Phillips
screws (4 per mounting rail)
3 mounting rails (2)
front of rack
1
2
3
Rack Installation Guide 15
Installing the System in the Rack
CAUTION: If you are installing more than one system, install the first system in the lowest available position
in the rack.
CAUTION: Because of the size and weight of the system, never attempt to install the system in the mounting rails
by yourself.
1
Pull the two inner slide rails out of the rack until they lock in the fully extended position.
2
Lift the system into position above the extended slides.
The three shoulder screws on the sides of the system fit into the corresponding J-slots (see detail
on Figure 1-7) on the inner slide assemblies.
3
Lower the back of the system while aligning the back shoulder screws on the sides of the system
with the back J-slots on the slide assemblies.
4
Engage the back shoulder screws into their respective J-slots.
5
Lower the front of the system and fit the middle and front shoulder screws into the J-slots in the slide
assemblies.
The system release latch at the front of the inner slide rail will snap back as the shoulder screw passes
into the front slot. Use this system release latch when you wish to remove the system from the slide
assemblies.
6
Press the slide-release latch on the outside of each inner slide, then push the system into the rack.
7
Install the cable-management arm. See "Installing the Cable-Management Arm" on page 17.
8
Tighten the thumbscrews on the rack front panel to secure the slide assemblies to the rack.
16 Rack Installation Guide
Figure 1-7. Installing the System in the Rack
Removing the System From the Rack
To remove the system from the rack, perform the following procedure:
1
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2
Remove the I/O cable connectors and power cable connectors from their respective connectors
on the system back panel.
3
Loosen the thumbscrews on each side of the front chassis panel that secures the system to the rack.
1 slide-release latch 2 shoulder screws (6) 3 J slots (6)
4 front release latch
1
2
4
3
Rack Installation Guide 17
4
Pull the system out of the rack until it stops because of the safety catch.
5
Pull up on the front release latch on each rail to disengage the safety catch (see Figure 1-7) and slide
the system forward.
6
Pull the system completely out of the rack.
Installing the Cable-Management Arm
NOTE: You can attach the
cable-management arm to either side of the rack cabinet.
NOTE: Attach the
cable-management arm ramp assembly to the side opposite of where you attach the cable-
management arm.
1
Fit the latch on the front end of the cable-management arm onto the bracket on the end of the
mounting rail until the latch clicks (see Figure 1-8).
2
Fit the latch on the unattached end of the cable-management arm onto the bracket on the end of the
slide assembly until the latch clicks (see Figure 1-8).
CAUTION: Both ends of the cable-management arm must be connected before you begin routing the system
cables
.
Figure 1-8. Installing the Cable-Management Arm
1 mounting rails (2) 2 brackets (2)
3 latches (2) 4 cable-management arm
back of system
1
2
4
3
18 Rack Installation Guide
Routing Cables
1
Open the wire cable basket on the top of the cable-management arm
, to
enable cables to be routed
within the arms (see Figure 1-9).
Figure 1-9. Routing Cables on the Cable-Management Arm
2
If applicable, connect the system status-indicator cable to its connector on the system back panel.
Route the system status-indicator cable through the cable-management arm, and press the LED end
into the slot on the end of the cable-management arm until it snaps into place.
3
Attach the I/O cable connectors and power cable connectors to their respective connectors on the
system back panel.
For details on cable connections, see your system’s Getting Started Guide or Hardware Owner’s
Manual.
NOTE: Use the retainer brackets on the back of the power supplies to provide strain relief for the power
cables.
4 Route the cables along the bend in the cable-management arm.
5
Adjust the cable slack as needed at the hinge position and secure the cables with the tie wraps
(see Figure 1-9).
6
Close the cable basket.
1 tie wraps (2) 2 system status-indicator cable connector
3 cable-management arm 4 wire cable basket
3
4
2
1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112

Dell PowerEdge 2970 Guide de démarrage rapide

Taper
Guide de démarrage rapide