TLP Pro 1220, 1520, and 1720MG • Setup Guide
Overview
The Extron TLP Pro 1220MG, TLP Pro 1520MG, and TLP Pro 1720MG are wall-mounted touchpanels with high resolution capacitive
touch screens. The TLP Pro 1220MG has a 12.1 inch screen with a 1280x800 resolution. The TLP Pro 1520MG has a 15.6 inch
screen with a 1366x768 resolution. The TLP Pro 1720MG has a 17.3 inch screen with a 1920x1080 resolution. They are ideal for any
AV applications requiring large touchpanels with exible mounting options and fully customizable interfaces. This guide provides
instructions for experienced installers to mount and install these touchpanels. For more complete procedures, see the TLPPro 1220,
TLPPro 1520, and TLP Pro 1720 Series User Guide at
www.extron.com.
Setup Checklist
Get Ready
Download and install the latest version of the following software:
z GUI Designer — For designing layouts for Extron TouchLink® Pro touchpanels and third party touch interfaces.
z Global Configurator
®
Plus and Professional — For setting up and conguring the control processor and touchpanel.
z Toolbelt — For device discovery, device information, rmware updates, and conguration of network settings, system
utilities, and user management for TouchLink Pro devices.
z Global Scripter
®
— Provides an integrated development environment for Extron control systems programming.
NOTE: All four software programs are available from www.extron.com.
Obtain the following network information from your network administrator:
DHCP status (on or off). If DHCP is off, you also require:
IP address Subnet mask Gateway
Username — this can be either admin or user.
Passwords — The factory congured passwords for all accounts on this device have been set to the device serial number.
Passwords can be changed during conguration. Passwords are case sensitive
NOTE: If the device is reset to default settings, the passwords are reset to the default password, which is extron (for
either admin or user).
Make a note of the touchpanel MAC address.
Mount and Cable All Devices
ATTENTION:
Do not power on the touchpanels or control processors until you have read the Attention in the Power Supply section of
the TLPPro 1220, TLPPro 1520, and TLP Pro 1720 Series User Guide or the IPL Pro User Guide.
Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «sources
d’alimentation» du TLPPro 1220, TLPPro 1520, and TLP Pro 1720 Series User Guide ou du IPLProUserGuide.
Mount the units. There are several mounting options for TouchLink Pro touchpanels (see Mounting on the following page).
Connect cables to the touchpanels. For more information about the cable connectors, see Rear Panel Features on page 4.
Connect the power cords and power on all devices.
Set up the Touchpanels for Network Communication
Connect the PC that you will use for setup, the control processor, and touchpanel to the same Ethernet subnetwork.
Use the Setup Menu (see page 5) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask, gateway,
and related settings for the touchpanel.
Configure the Touchpanels
Create a graphical user interface with GUI Designer (see GUI Designer Help File for step-by-step instructions).
Associate functions with the graphical user interface features by conguring (see the Global Configurator Help File) or
programming (see the Global Scripter Help File) the system. Global Scripter provides an Extron-exclusive Python library
(ControlScript
®
) and Global Scripter modules to get you started.
2
TLP Pro 1220, 1520, and 1720MG • Setup Guide (cont’d)
Mounting
Wall Mounting
The touchpanels can also be wall-mounted, either using the Extron BB 700M wall box or directly into drywall. The diagram below
shows the TLP Pro 1520MG. Mount the TLP Pro 1220MG or TLP Pro 1720MG in the same way.
ATTENTION:
Do not install the TLP Pro 1220MG, TLP Pro 1520MG, or TLP Pro 1720MG in a re resistant rated wall or partition
assembly.
Ne pas installer le TLP Pro 1220MG, le TLP Pro 1520MG, ou le TLP Pro 1720MG dans un mur résistant au feu ou une
cloison.
All structural steps and electrical installation must be performed by qualied personnel in accordance with local and
national building codes and electrical codes.
Toute étape structurelle et installation électrique, doit être effectuée par un personnel qualié, conformément aux codes
du bâtiment, aux codes incendie et sécurité, et aux codes électriques, locaux et nationaux.
With a wall box
Some local building codes require the touchpanel to be
mounted in a wall box such as the Extron BB 700M. This
installation procedure is described below.
1. Cut a hole in the drywall, 9.55 inches (243 mm)
wide x 6.55 inches (166 mm) high, and
install the BB 700M, as described in
the BB 700M Installation Guide (see
www.extron.com).
2. Place the metal mounting plate against
the wall, mark the four mounting holes,
and drill four pilot holes.
3. Secure the mounting plate with four #10
screws.
4. Run and connect cables to the back
of the touchpanel (see
Rear Panel
Features on page 4).
5. Insert the two provided Phillips pan
head #6-32 x ¾ inch length screws with
washers in the mounting screw slot (see
figure 3,
J
). Leave a gap for the ange
at the bottom of the mounting plate to
t into.
6. Hold the touchpanel at a slight angle and
lower the notches at the top of the back
panel (see
figure 3,
I
) over the hooks of the
mounting plate.
7. Swing the bottom of the touchpanel inwards so
that it lies at against the mounting plate with the
ange at the bottom of the mounting plate sitting in
a groove in the bottom of the touchpanel.
8. Secure the touchpanel to the mounting plate with
the mounting screws.
steps 3-8
Install BB 700M (optional).
TLP Pro 1520MG
Back View
Hold the touchpanel at a slight angle.
Mount the touchpanel over the two
hooks on the mounting plate.
Add the mounting plate. Align with
the wall box and mark holes for screws.
Secure the mounting plate
to the wall with screws (4).
Place the provided mounting screws (2)
with washers in the mounting screw slot
in the touchpanel.
6
5
3
1
2
4
8
Secure the touchpanel by tightening the
mounting screws against the base of the
mounting plate.
Figure 1. TLP Pro 1520MG Mounting
Without a wall box
If the wall box is not required by local building codes, you can mount the touchpanel directly into drywall.
1. Download the cut-out template for your touchpanel from www.extron.com. Print it at 100% (no scaling).
2. Use the template to mark the wall, cut the hole, and drill the four pilot holes.
3. Secure the mounting plate and complete the installation, as described in steps 3-8 above.
3
Product Category
Rack Mounting
These touchpanels can be mounted in any standard 19-inch equipment rack, using the optional rack mounting kit.
TLP Pro 1220MG: RM 2 kit
TLP Pro 1520MG: RM 3 kit TLP Pro 1720MG: RM 3 kit
Read the Underwriters Labs Guidelines for Rack Mounting in the TLPPro 1220, TLPPro 1520, and TLP Pro 1720 Series User Guide
and follow the instructions provided with the appropriate kit.
Front Panel Features
Figure 2 shows the TLP Pro 1720MG front panel diagram. The TLP Pro 1220MG and TLP Pro 1520MG are very similar.
A
A
AB
B
BC
CCDD
D
E
EEEE
EF
F
F
G
G
G
Figure 2. TLP Pro 1720MG Front Panel
A
Communication LED — Shows the conguration and connection status of the touchpanel:
z Unlit during normal operation.
z Blinks red if the touchpanel has been congured but is not connected to an IP Link Pro control processor.
z Lights steadily if the touchpanel has not been congured.
The indicator can be enabled and disabled, using the
Setup Menu (see page 5).
B
Status light — can be programmed to provide system feedback. The LED light bar is located above the screen.
C
Ambient light sensor — monitors ambient light level and adjusts screen brightness.
D
Capacitive touch screen — provides simple control of AV systems:
z The TLP Pro 1220MG has a 12.1 inch screen with a 1280x800 resolution.
z The TLP Pro 1520MG has a 15.6 inch screen with 1366x768 resolution.
z The TLP Pro 1720MG has a 17.3 inch screen with 1920x1080 resolution.
E
Speakers (2) — provide stereo audio for video preview and audible feedback from button presses. They are located below the
screen, one on each side of the panel.
F
Motion sensor — detects motion in front of the touchpanel.
G
Menu button — activates the setup menu and calibration screen (see Setup Menu). It is accessed from under the touchpanel.
It performs the same function as the rear panel
Menu button but is easier to reach when the touchpanel is installed.
figure 2
4
TLP Pro 1220, 1520, and 1720MG • Setup Guide (cont’d)
A
A
A
B
B
B
C
C
C
D
D
D
E
E
EF
F
FG
G
G
I
I
I
J
J
J
H
H
H
Figure 3. TLP Pro 1720MG Rear Panel
figure 3
F
XTP/LAN/PoE input
z XTP input — Connect the touchpanel to the XTP source using a twisted pair cable, terminated with an RJ-45 connector.
For complete information about which cables to use, see the user guide for your XTP product.
z LAN input — Connect the touchpanel to the LAN using a twisted pair cable, terminated with an RJ-45 connector.
z PoE input — the connector can be used with a PoE power injector (not provided). Connect the cables as shown in gure 4,
which shows the Extron PI 140 power injector (recommended by Extron).
NOTE: Some XTP models are able to remotely power these touchpanels but not all have that capability. Go to the Extron
website and check the product page for your XTP model to ensure it can power your touchpanel.
An Extron IP Link Pro control processor must also be connected to the same network as the TouchLink Pro touchpanel.
G
HDMI input — For alternative video input.
H
Power supply input — Connect a 12 VDC, 3.0 A Limited Power Source (LPS) power supply (not provided) to this captive screw
connector.
ATTENTION:
The touchpanels can use a 12 VDC desktop power supply or Power over Ethernet. Do not connect either power
supply before reading the Attention in the Power section of the TLPPro 1220, TLPPro 1520, and TLP Pro 1720
Series User Guide.
Les écrans tactiles peuvent utiliser une source d’alimentation externe 12 Vcc ou l’alimentation POE via Ethernet.
Ne branchez pas de sources d’alimentation externes avant d’avoir lu les mises en garde dans la section
«PowerSupply» du TLPPro 1220, TLPPro 1520, and TLP Pro 1720 Series User Guide.
NOTE: The TLP Pro 1720MG ships with the Extron PI 140 power injector included. For the TLP Pro 1220MG and
TLP Pro 1520MG, either a 12 VDC, 3.0 A power supply or a power injector must be purchased separately.
I
Mounting plate notch (2) — Fit over the hooks at the top of the mounting plate (see Wall Mounting on page 2).
J
Mounting screw slot (2) — Insert the provided screws here. Secure the touchpanel to the mounting plate.
note
Rear Panel Features
A
Reset LED — Provides feedback about
the reset status when the user presses
the reset button.
B
Reset button — Pressing the Reset
button allows the unit to be reset
in any of three different modes (see
Reset Modes on page 5. For more
information, see the TLPPro 1220,
TLPPro 1520, and TLP Pro 1720 Series
User Guide.
C
Menu button — Activates the setup
menu and calibration screen (see
Setup
Menu on the following page).
D
USB connectors — For peripheral
controls.
E
Audio output — For use with
headphones or assistive listening
devices.
5
Product Category
from the switch or router to the power supply input.
2. Connect a second straight-through cable from the power injector to the TLP
Pro touchpanel XTP/LAN/PoE connector (see
figure 3,
F
, on page 4). This
cable carries the network information and 48VDC from the power injector to
the touchpanel.
3. Connect the IEC power cord to a convenient 100 VAC to 240 VAC, 50-60 Hz
power source.
Connecting Power
ATTENTION:
The touchpanels can use a 12 VDC desktop power supply or Power over Ethernet. Do not connect either power supply
before reading the Attention in the Power section of the TLPPro 1220, TLPPro 1520, and TLP Pro 1720 Series User Guide.
Les écrans tactiles peuvent utiliser une source d’alimentation externe 12 Vcc ou l’alimentation POE via Ethernet. Ne
branchez pas de sources d’alimentation externes avant d’avoir lu les mises en garde dans la section «PowerSupply» du
TLPPro 1220, TLPPro 1520, and TLP Pro 1720 Series User Guide.
The Extron PI 140 power injector is included with the TLP Pro 1720MG. For the TLP Pro 1220MG or TLP Pro 1520MG, a 12 VDC
power supply or a power injector must be purchased separately. Figure 4 shows the Extron PI 140. Your power injector may look
different.
1. Connect a straight-through Ethernet cable from the power injector to a switch or router. This cable carries network information
100-240V~50/60 Hz
1.1A MAX
INPUT OUTPUT
POWERED TLP
LAN
To Network or
XTP Device
To a TLP Pro
touchpanel
Extr
on PI 140
Figure 4. Connecting the Power Injector
Alternatively, use an Ethernet cable to connect the XTP/LAN/PoE port of the interface to a PoE+ switch or connect the touchpanel
directly to an XTP model that is capable of remotely powering a touchpanel (see the
note on page 4).
Reset Modes: a Brief Summary
The TLP Pro 1220MG, TLP Pro 1520MG, and TLP Pro 1720MG offer the following reset modes. For full information about the modes,
see the TLPPro 1220, TLPPro 1520, and TLP Pro 1720 Series User Guide.
Use factory firmware:
Press and hold the Reset button (figure 3,
B
) while applying power to the unit. Use this
mode to replace rmware in the event of rmware failure.
Reset All IP Settings:
Press and hold the Reset button for 6 seconds. After the Reset LED (
A
) ashes twice,
release and momentarily press the Reset button. Use this mode to reset all network settings
without affecting user-loaded les.
Reset to Factory Defaults:
Press and hold the Reset button for 9 seconds. After the Reset LED ashes three times,
release and momentarily press the Reset button. Use this mode to return the interface to
factory default settings.
NOTES:
The factory congured passwords for all accounts on this device have been set to the
device serial number. Passwords can be changed during conguration. Passwords are
case sensitive.
If the device is reset to default settings, the passwords are reset to the default
password, which is extron (for either admin or user).
Enable or Disable the
DHCP Client
Use this mode to toggle between DHCP enabled and DHCP disabled. Press the Reset button
ve times, consecutively. After the fth press, do not press the button again within 3 seconds.
If DHCP was enabled, it is now disabled and the Reset LED blinks three times. If DHCP was
disabled, it is now enabled and the Reset LED blinks six times.
Reset Modes
Setup Menu
Press the Menu button (figure 2,
G
or figure 3,
C
) to open the
setup menu. Select any of the six available screens (Status,
Network, Display, Audio, Input and Advanced) by pressing the
appropriate button in the navigation bar at the top of the screen (for
more information, see the TLPPro 1220, TLPPro 1520, and TLP Pro
1720 Series User Guide).
Figure 5 shows the setup menu for the TLP Pro 1220MG. The setup
menus for the TLP Pro 1520MG and TLP Pro 1720MG are almost
identical.
Press the
Menu button for at least 3 seconds to open the calibration
screen. Follow the on-screen instructions.
Info
Model: TLP Pro 1220MG
Part Number: 60-1340-02
Firmware
Version:
1.02.0000.b003
PoE: Active
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLI-AB-CD-EF
Display
Resolution:
Project:
Sleep Timer:
1280x800
1280x800
5 Minutes
Audio
Master Volume:
Master Mute: Off
100
Input
HDMI: No Signal
Status
Display
Audio
Advanced
Exit
Network
Input
Advanced
Controller IP: 192.168.254.250
Project Size: 1/197 MB
Bootloader
Version:
1.03.0000
XTP: 1280x720
HDCP
Figure 5. Setup Menu: Status page for TLP Pro 1220MG
6
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
For information about replacing and disposing of batteries, see the TLP Pro 1225 and TLP Pro 1525 Series User Guide at
www.extron.com.
© 2016 - 2020 Extron — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
68-2294-50 C
08 20
TLP Pro 1220, 1520, and 1720MG • Setup Guide (cont’d)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Extron electronics TLP Pro 1720MG Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues