TP-LINK tp-link AP9635 Omada Pro Ceiling Mount Access Point Mode d'emploi

Taper
Mode d'emploi
Regulatory Compliance
Ceiling Mount AP
FCC Compliance Information Statement
Product Name: Omada Pro Ceiling Mount Access Point
Model Number: AP9635 / AP9650 / AP9670 / AP9778
Responsible party:
TP-Link USA Corporation
Address: 10 Mauchly, Irvine, CA 92618
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6804
E-mail: sales.usa@tp-link.com
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/ TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Note: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user’s authority
to operate the equipment.
FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. This device and its antenna must not be co-located or operating in conjunction with
any other antenna or transmitter.
To comply with FCC RF exposure compliance requirements, this grant is applicable to only Mobile
Configurations. The antennas used for this transmitter must be installed to provide a separation
distance of at least 20cm from all persons and must not be colocated or operating in conjunction
with any other antenna or transmitter.”
For AP9778:
FCC regulations restrict operation of this device to indoor use only. The operation of this device
is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation of this device
is permitted in large aircraft while flying above 10000 feet in the 5.925-6.425 GHz band. Operation of
transmitters in the 5.925-7.125 GHz band is prohibited for control of or communications with
unmanned aircraft systems.
We, TP-Link USA Corporation, has determined that the equipment shown as above has been
shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized
change is made in the equipment and the equipment is properly maintained and operated.
Issue Date: 2023-05-05
CE Mark Warning
This is a class B product. In a domestic environment, this product may cause radio interference, in
which case the user may be required to take adequate measures.
OPERATING FREQUENCY (the maximum transmitted power)
For AP9635 / AP9650 / AP9670:
2412 MHz -2472 MHz (20dBm)
5150 MHz -5250 MHz (23dBm)
5250 MHz -5350 MHz (23dBm)
5470 MHz -5725 MHz (30dBm)
For AP9778:
2412 MHz -2472 MHz (20dBm)
5150 MHz -5250 MHz (23dBm)
5250 MHz -5350 MHz (23dBm)
5470 MHz -5725 MHz (30dBm)
5925MHz -6425 MHz (23dBm)
EU Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and
other relevant provisions of directives 2014/53/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU Declaration of Conformity may be found at
https://www.tp-link.com/en/support/ce/.
RF Exposure Information
This device meets the EU requirements (2014/53/EU Article 3.1a) on the limitation of exposure of
the general public to electromagnetic fields by way of health protection.
The device complies with RF specifications when the device used at 20cm from your body.
National Restrictions
For AP9635 / AP9650 / AP9670:
Frequency band: 5150 - 5250 MHz:
Indoor use: Inside buildings only. Installations and use inside road vehicles and train carriages
are not permitted. Limited outdoor use: If used outdoors, equipment shall not be attached to a
fixed installation or to the external body of road vehicles, a fixed infrastructure or a fixed outdoor
antenna. Use by unmanned aircraft systems (UAS) is limited to within the 5170 - 5250 MHz band.
Frequency band: 5250 - 5350 MHz:
Indoor use: Inside buildings only. Installations and use in road vehicles, trains and aircraft are not
permitted. Outdoor use is not permitted.
Frequency band: 5470 - 5725 MHz:
Installations and use in road vehicles, trains and aircraft and use for unmanned aircraft systems
(UAS) are not permitted.
For AP9778:
Frequency band: 5150 - 5250 MHz:
Indoor use: Inside buildings only. Installations and use inside road vehicles and train carriages
are not permitted. Limited outdoor use: If used outdoors, equipment shall not be attached to a
fixed installation or to the external body of road vehicles, a fixed infrastructure or a fixed outdoor
antenna. Use by unmanned aircraft systems (UAS) is limited to within the 5170 - 5250 MHz band.
Frequency band: 5250 - 5350 MHz:
Indoor use: Inside buildings only. Installations and use in road vehicles, trains and aircraft are not
permitted. Outdoor use is not permitted.
Frequency band: 5470 - 5725 MHz:
6105 MHz -6425 Mhz
Installations and use in road vehicles, trains and aircraft and use for unmanned aircraft systems
(UAS) are not permitted.
Frequency band 5945 -6425MHz:
Restricted to indoor use, including in trains with metal-coated windows and aircraft.
Outdoor use, including in road vehicles, is not permitted.
UKCA Mark
UK Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements
and other relevant provisions of the Radio Equipment Regulations 2017.
The original UK Declaration of Conformity may be found at
https://www.tp-link.com/support/ukca
National Restrictions
Attention: This device may only be used indoors in Great Britain.
UK
Canadian Compliance Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to
the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
Lémetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux
CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1) Lappareil ne doit pas produire de brouillage;
2) Lappareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Caution
For AP9635:
1) The device for operation in the band 5150–5250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems; 5150 MHz to 5350
MHz is restricted to indoor operations in Hong Kong.
For AP9650 / AP9670 / AP9778:
1) The device for operation in the band 5150–5250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems; 5150 MHz to 5350
MHz is restricted to indoor operations in Hong Kong.
DFS (Dynamic Frequency Selection) products that operate in the bands 5250- 5350 MHz, 5470-
5600MHz, and 5650-5725MHz.
Avertissement
Pour AP9635:
1) Le dispositif fonctionnant dans la bande 5150-5250 MHz est réservé uniquement pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux;
Pour AP9650 / AP9670 / AP9778:
1) Le dispositif fonctionnant dans la bande 5150-5250 MHz est réservé uniquement pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux;
Les produits utilisant la technique d'atténuation DFS (sélection dynamique des fréquences) sur
les bandes 5250- 5350 MHz, 5470-5600MHz et 5650-5725MHz.
For AP9778:
ISED regulations restrict operation of this device to indoor use only. The operation of this
device is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation of this
device is permitted in large aircraft while flying above 10000 feet in the 5.925-6.425 GHz band.
Operation of transmitters in the 5.925-7.125 GHz band is prohibited for control of or
communications with unmanned aircraft systems.
Pour AP9778:
Les réglementations ISED limitent le fonctionnement de cet appareil à une utilisation en
intérieur uniquement. L'utilisation de cet appareil est interdite sur les plates-formes pétrolières,
les voitures, les trains, les bateaux et les avions, sauf que l'utilisation de cet appareil est
autorisée dans les avions long courrier en vol au-dessus de 10 000 pieds. L'exploitation
d'émetteurs dans la bande 5,925-7,125 GHz est interdite pour le contrôle ou les communications
avec des systèmes d'avions sans pilote.
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
Déclaration d'exposition aux radiations:
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de
20cm de distance entre la source de rayonnement et votre corps.
Industry Canada Statement
CAN ICES-3 (B)/NMB-3(B)
Korea Warning Statements
해 무선설비는 운중 전파혼신 가성이 있음 .
NCC Notice & BSMI Notice
意!
取得審驗證明低功率射頻器材非經核准號或使用者均不得擅變更頻率、加大功率或變
更原設特性及功能。
低功率射頻器材之使用不得影響飛航安全及干擾合法通信經發現有干擾現象時應立即停並改
善至使
法通信指依電管理法規定作業之無線通信。
低功率射頻器材須忍受合法通信或工業、科學醫療用電波輻射性機設備之干擾。
應避免影響附近雷達系統之操作
安全諮詢及注意事項
使用原裝電源器或只能照本產品注明的電型使用本產
清潔本產品之前請先拔掉電源線 . 請勿使用液體噴霧清潔劑或濕布進行清潔
潮,將水其他
插槽與開口供通風使用以確保本產品的操作可靠並防止過熱,請勿堵塞或覆蓋開口
請勿將本產品置放於靠近熱源的地方 . 除非有正常的通風,否則不可放在密閉位置中
不要私拆開機殼或自行維修如產品有故障請與原廠或代理商聯繫
限用物質含有情況標示聲明書
產品元件名稱
限用物質及其化學符號
Pb
Cd 汞
Hg 六價鉻
CrVI 多溴聯苯
PBB 多溴二苯醚
PBDE
PCB ○ ○ ○
外殼 ○ ○ ○
電源供應器 ○ ○ ○
其他及其配件 ○ ○ ○
備考1."超出0.1wt%"及"超出0.01wt%"系指限用物質之百分比含量超出百分比含量基準值.
備考2."○"系指該項限用物質之百分比含量未超出百分比含量基準值.
備考3."—"系指該項限用物質為排除項目.
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам
нормативних документів та вимогам, що передбачені чинними законодавчими актами
України.
Safety Information
Keep the device away from water, fire, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you need service, please
contact us.
Do not use damaged charger or USB cable to charge the device.
Do not use any other chargers than those recommended.
Do not use the device where wireless devices are not allowed
Adapter shall be installed near the equipment and shall be easily accessible.
Operating Temperature: 0 ~ 40 (32 ~ 104 )
This product uses radios and other components that emit electromagnetic fields.
Electromagnetic fields and magnets may interfere with pacemakers and other implanted
medical devices. Always keep the product and its power adapter more than 15 cm (6 inches)
away from any pacemakers or other implanted medical devices. If you suspect your product
is interfering with your pacemaker or any other implanted medical device, turn off your
product and consult your physician for information specific to your medical device.
Please read and follow the above safety information when operating the device. We cannot
guarantee that no accidents or damage will occur due to improper use of the device. Please use
this product with care and operate at your own risk.
Explanation of the symbols on the product label
Note: The product label can be found at the bottom of the product.
Symbol Explanation
Class II equipment
Alternating current
Direct current
For indoor use only
Polarity of d.c. power connector
Energy efficiency marking (Level VI)
Caution
Operator's manual
RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic
equipment (WEEE). This means that this product must be handled pursuant to European
directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the
environment.
User has the choice to give his product to a competent recycling organization or to the
retailer when he buys a new electrical or electronic equipment.
Mounting Requirements
For safety, we recommend you to use the original screws in the package when mounting. The
following are alternatives to mount the device on the wall:
Use 4 screws which comply with ANSI B1.1 4# standard and are longer than 15 mm.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

TP-LINK tp-link AP9635 Omada Pro Ceiling Mount Access Point Mode d'emploi

Taper
Mode d'emploi