The table below explains the abbreviations and displays the possible settings.
Table 1: Analog and teach parameter list
Name Display Description Value
selection
Display Initial
value
Description
MF MF Enables the configuration of
the multifunctional input/
output.
OFF, OUT,
TCH, LSR,
LSN
oFF The external input has no
function.
out In 4-pin devices: Pin 4 func‐
tions as a switching output.
tch For 5-pin devices: The exter‐
nal input is a teach-in input.
For a functional description,
see see „Electronics“, page 7
LSr X The external input functions
as a laser shutdown, high-
active.
LSn The external input functions
as a laser shutdown, low-
active.
N_P n_P Switchover between PNP/NPN
mode.
PNP, NPN PnP X Inputs and outputs are in PNP
mode.
nPn Inputs and outputs are in NPN
mode.
V_A U_A Switchover between current/
voltage output.
CUR, VLT cur X The analog output functions
as a current output.
ULt The analog output functions
as a voltage output.
L_D L_D Switchover between light/
dark switching
LON, DON,
STB, STD
Lon X Light switching: The switching
output switches on when the
object is closer than the
taught sensing range.
don Dark switching: The switching
output switches off when the
object is closer than the
taught sensing range.
Stb The switching output Q1
issues the stability of the
measured value acquisition
(therefore corresponds to the
LED stability display). Light
switching functionality.
Std The switching output Q1
issues the stability of the
measured value acquisition
(therefore corresponds to the
LED stability display). Dark
switching functionality.
AVG AUG Setting the moving arithmetic
average
1, 4, 16,
64, 256
64 64 Sets the number of values
across which a moving arith‐
metic average is established
when the signal is output.
This smooths the signal out‐
put. The possible values are
1, 4, 16, 64, or 256 (e.g., 1 =
no averaging, 256 = average
across 256 values)
4 CONFIGURATION
10
8020032.ZX33 | SICK
Subject to change without notice