Signature Kitchen Suite SKSCW241RP Guide d'installation

Taper
Guide d'installation
Integrated Refrigeration Installation Guide
BUILT-IN REFRIGERATION
SKSCF1801P
SKSCF2401P
SKSCF3001P
SKSCW181RP
SKSCR2401P
SKSCR3001P
SKSCW241RP
Copyright © 2020-2023 Signature Kitchen Suite. All Rights Reserved.
www.signaturekitchensuite.com
MFL67410824_Rev.07
ENGLISH FRANÇAIS ESPAÑOL
2
Table of Contents
SAFETY INSTRUCTIONS ............................. 3
Before Installation ......................................... 6
Choosing the Install Location ....................... 6
Installation options ....................................... 9
Dimensions and Clearances
SKSCF1801P – 18" INTEGRATED
FREEZER COLUMN
SKSCW181RP – 18" INTEGRATED
WINE COLUMN .......................................... 10
SKSCF2401P – 24" INTEGRATED
FREEZER COLUMN
SKSCR2401P – 24" INTEGRATED
REFRIGERATOR COLUMN
SKSCW241RP – 24" INTEGRATED
WINE COLUMN .......................................... 12
SKSCF3001P – 30" INTEGRATED
FREEZER COLUMN
SKSCR3001P – 30" INTEGRATED
REFRIGERATOR COLUMN ....................... 14
Custom Panels
SKSCF1801P – 18" INTEGRATED
FREEZER COLUMN
SKSCW181RP – 18" INTEGRATED
WINE COLUMN .......................................... 16
SKSCF2401P – 24" INTEGRATED
FREEZER COLUMN
SKSCR2401P – 24" INTEGRATED
REFRIGERATOR COLUMN
SKSCW241RP – 24" INTEGRATED
WINE COLUMN ......................................... 18
SKSCF3001P – 30" INTEGRATED
FREEZER COLUMN
SKSCR3001P – 30" INTEGRATED
REFRIGERATOR COLUMN ....................... 20
Required Accessories and Tools ................ 22
Installation .................................................. 23
Unpacking ...................................................... 24
Moving the Appliance .................................... 25
Special Circumstances .................................. 25
Product Dimensions ...................................... 26
A
Installing the Anti-tip Brackets ....................... 29
Protecting Edges of Enclosure ..................... 30
Installing Appliance in Enclosure .................. 31
B
Aligning and Leveling the Appliance ............. 32
Attaching the Appliance to the Enclosure ...... 34
Attaching the Toe Kick Panel ........................ 35
C
Installing Door Panels .................................. 37
Adjusting Door Panels .................................. 38
Installing Door Trim ...................................... 38
Attaching Air Separator ................................. 39
Special Installations
Optional Frame Kit Accessory ...................... 39
Adjusting the Door Spring ............................ 40
Adjusting the Door Stop ............................... 40
Water Filter Bypass ...................................... 40
Reversing the Door ...................................... 41
Side-by-Side Flush Installation ..................... 45
Preparing to Connect the Water Line ............ 47
Connecting the Water Line ........................... 47
Attaching the Badge ..................................... 48
3
ENGLISH
SAFETY INSTRUCTIONS
WARNING
TIP-OVER HAZARD
Use two or more people to move and install the refrigerator.
To prevent the refrigerator from tipping over, install anti-tip brackets
(provided). Failure to follow the refrigerator installation instructions
can result in serious injury or death.
WARNING You may be killed or seriously injured if you don’t follow instructions.
WARNING To reduce the risk of fire, electric shock, or personal injury when using
the product, basic safety precautions should be followed, including the
following. Read all instructions before using this appliance.
CAUTION Indicates an imminently hazardous situation which, if not avoided, may
result in minor or moderate injury, or product damage.
IMPORTANT SAFETY INSTRUCTIONS
This guide contains many important safety messages.
Always read and obey all safety messages.
This is the safety alert symbol. It alerts you to safety messages that inform you of hazards
that can kill or hurt you or others or cause damage to the product.
All safety messages will be preceded by the safety alert symbol and the hazard signal word
WARNING, or CAUTION. These words mean:
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and
tell you what can happen if the instructions are not followed.
Installation
These products are not designed to be used as freestanding units. Doing so will result in a
risk of tipover, personal injury, and product or property damage.
Do not install the refrigerator near a gas stove, water heater or other source of ignition that
may possibly leak gas. Do not install product in direct sunlight. Install the product in a well-
ventilated area.
Ensure that enclosure dimensions allow for sufficient air circulation at the sides and back of
the product. Do not block the front air inlet. Failure to follow these instructions may cause
product malfunction.
Enclosure must be constructed of materials which are strong enough to avoid damage
during installation and frequent use.
4
Cabinet materials must be able to withstand the heat and humidity produced during product
operation and use without twisting or deforming.
Install the product on a firm, level surface that can support the weight of the product without
bending. The product must be level both horizontally and vertically.
• Keep children away from area during installation.
• Do not use an extension cord or power strip with this product.
Do not install the refrigerator in a damp location or where it will be exposed to running water.
Deterioration of the insulation on electrical parts may result, causing risk of electric shock.
• Connect to potable water only. Non-potable water can cause health risks.
• If connected to a circuit protected by fuses, use time delay fuse.
Electrical Connection
Use a dedicated outlet.
• Plugging several devices into one outlet may cause a fire.
Plug in the power plug with the power cord facing downward.
Failure to do so could damage the plug or cord, resulting in fire or electric shock.
When installing or moving the refrigerator, be careful not to roll over or damage the
power cord. Do not squeeze or crush the cord or plug when pushing the refrigerator in.
Doing so could result in fire or electric shock.
Do not allow the power cord to be bent, crushed, or damaged. Do not run the power
cord under heavy objects like furniture, other appliances, or through high-traffic areas.
Doing so may damage the power cord and result in fire or electric shock.
Do not extend or modify the length of the power cord.
Use only an exact factory replacement part to avoid electrical issues, fire, or electric shock.
Turn off the power before cleaning or moving the refrigerator.
• Failure to do so may cause electric shock or injury.
• Press the POWER button for 3 seconds to turn off the power at display panel.
Do not pull out the cord or touch the power plug with wet hands.
Doing so may cause electric shock or injury.
Remove water or dust from the power plug and insert it securely into the wall socket.
Dust, water, or a loose connection may cause a fire or electric shock.
Do not unplug the refrigerator by pulling on the cord.
Doing so may cause electric shock or short circuit resulting in a fire.
Do not use the power cord or the power plug if it is damaged or if the outlet is damaged.
Doing so may cause electric shock or short circuit resulting in a fire.
Wait for 5 minutes or longer when reconnecting the plug or turning the power back on.
Give the compressor time to cycle before restarting.
5
ENGLISH
General
These installation instructions are intended for use by qualified installers. All connections for water,
electrical power and grounding must comply with local codes and ordinances and be made by
licensed personnel when required. In the absence of a local code:
In the U.S.A., in accordance with the National Electric Code, ANSI/NFPA70 – latest edition/State
and Municipal codes and/or local codes.
In Canada, in accordance with the Canadian Electric Code C22.1 – latest edition/Provincial and
Municipal codes and/or local codes.
Appliance is very heavy:
Refrigerator 30" approx. 386 Ibs/175 kg
Refrigerator 24" approx. 324 Ibs/147 kg
Freezer 30" approx. 403 Ibs/183 kg
Freezer 24" approx. 346 Ibs/157 kg
Freezer 18" approx. 304 Ibs/138 kg
Wine 18" approx. 306 lbs/139 kg
Wine 24" approx. 357 lbs/162 kg
CAUTION
Do not remove the cover of the automatic ice dispenser.
The internal mechanism of the icemaker can cause injury if handled.
Do not stick your hands under the refrigerator.
Sharp edges, fans, and wires may cause an injury
Save these instructions for the local inspector's use.
Observe all governing codes and ordinances.
Installer: Leave these instructions with the consumer.
Consumer: Keep these instructions with the owner's manual for future reference.
If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
6
Before Installation
Choosing the Install Location
Anti-tip Devices
WARNING
Do not store or install the appliance where it will be exposed to:
• outside weather
• water damage
• temperatures under 32°F (0°C)
Temperature and Humidity
The appliance should be installed in a dry, well ventilated area.
The ambient temperature should stay between 55 °F(13 °C) and 110 °F (43 °C), to avoid
malfunctions.
Do not install product where it will be exposed to direct sunlight or near a heat source, such as an
oven or radiator.
WARNING: Tip Hazard
The appliance is very heavy and may tip over if the door is opened before the appliance is
securely installed.
Install the supplied anti-tip brackets to prevent the appliance from tipping. The safest method of
installing the appliance in a stable position is to use the supplied anti-tip devices.
• Do not open the appliance door unless it is still on the pallet or the anti-tip brackets are engaged.
If the enclosure is sturdy enough, attaching the appliance to the upper and side walls of the
enclosure may provide additional stability, as long as the enclosure is firmly connected to the back
wall. If in doubt, contact an architect or structural engineer.
7
ENGLISH
Enclosure
Floor
The panel above the appliance must be made from a solid material (not MDF) that is at
least 5/8" (16 mm) thick.
• The side walls of the cavity or enclosure must be flush.
The front 4 inches (100 mm) of the interior surface (furniture return) will be visible when
doors are open. Make sure this area is finished to at least 4 inches deep.
• Follow the specifications for the installation enclosure to ensure a trouble free installation.
Above all, the enclosure cannot be out of square. Use a spirit level or measure the
diagonals of the opening to make sure corners are square.
The appliance is attached at the sides and the top to either the enclosure or to adjacent
cabinets. Make sure the enclosure or the adjacent cabinets are securely connected to the
floor or wall structures.
WARNING
The floor in the installation area must be firm, level, and rigid for safe installation and best
performance.
• Do not install the appliance on a platform or raised structure.
The structure underneath the appliance must be able to support the weight of the appliance
without tilting or flexing.
• For best performance and to avoid leakage, level the appliance.
Electrical Requirements
WARNING
Electrical Shock Hazard
• Plug into a grounded 3 prong outlet.
• Do not remove ground prong.
• Do not use an adapter.
• Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
Follow all state and local codes or NEC.
The appliance comes with a UL listed 3 wire power supply cord.
The appliance requires a 3-wire receptacle.
The receptacle must be installed by a licensed electrician only.
8
Grounding
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a path of least resistance for the electric current.
WARNING: Improper connection of the equipment grounding conductor may result in electric
shock. Have the appliance checked by a qualified electrician or service technician
if you are in doubt as to whether the appliance has been properly grounded.
NOTE
Some local regulations may require a separate ground. In such cases, the required ground
wire, clamp and screw are available as a separate accessory and must be purchased
separately.
Never ground the appliance to plastic plumbing lines, gas lines or water pipes.
Water Connection
CAUTION
• Connect the appliance to potable water only.
A cold water connection is required for operation of the automatic ice maker. The water pressure
must be between 20 and 120 psi. (1.38-8.27).
• The installation must comply with local plumbing regulations.
A separate shut-off valve must be installed for the appliance water connection.
• Do not use a self-piercing valve.
Do not install the shutoff valve for the water behind the appliance. The shutoff valve must be
easily accessible.
Install the water connection in the area shown in the diagram under Dimensions and Clearances.
The water supply line can be located on the right side, on the left side, or in the floor. The
maximum outer diameter of the supply line (without fittings) is 3/8" (9.5 mm).
9
ENGLISH
Installation options
There are many different installation options.
These are limited only by the design of the kitchen.
Individual Appliance
OK OK X
Side-by-Side (Pair)
OK X X X
Individual Appliances with Partition
Minimum thickness of the partition 5/8” (16 mm)
1 1/4" (32 mm) 7 7/8" (200 mm)
**25/32” (20 mm)
*1 9/16” (40 mm)
**25/32” (20 mm)
*1 9/16” (40 mm)
**25/32” (20 mm)
*1 9/16” (40 mm)
OK OK
OK OK
OK
A A A
* When not using 90° door stop pin
** When using 90° door stop pin on the A product
10
SKSCF1801P – 18" INTEGRATED FREEZER COLUMN
SKSCW181RP – 18" INTEGRATED WINE COLUMN
NOTE
Freezer/Wine column can be installed ush or proud.
Flush – With a 25" (635 mm) cutout depth, the front face of the freezer/wine column ts ush with 25"
(635 mm) depth adjacent cabinets.
Proud – With a 24" (610 mm) depth cutout, the front face of the freezer/wine column extends
approximately 3/4" (19 mm) beyond 24" (610 mm) depth adjacent cabinets.
A minimum 4" (102 mm) nished return that matches the cabinet exterior is recommended on all
sides and the top of the cutout opening. The shaded area will be visible after installation.
ELECTRICAL
A 115V, 60Hz, 15 or 20 amp power supply is required. An individual, properly grounded branch
circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
WATER LINE
A cold water supply is required for automatic icemaker operation.
The water pressure must be between 20 and 120 psi.
Tubing should be long enough to extend to the front of the freezer. Allow enough tubing to
accommodate a bend leading into the water line connection.
Water line can enter an opening through the oor or back wall.
Install a shut-o valve between the icemaker water valve and the cold water supply in the home.
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION, SINGLE COLUMN
1 3/8" (35mm)
Electrical location
Is Not available
1 3/8" (35mm)
Electrical location
Is Not available
18" (457 mm)
84"
(2134 mm)
5"
(127 mm)
electrical
location
4"
(102 mm)
water
location
4"
(102 mm)
finished
return*
25"(635 mm)
min. depth
flush install
24" (610 mm)
min. depth
proud install
finished width
11
ENGLISH
NOTE
Door Swing Clearances
The installation must allow for clearances to adjacent walls or cabinets. This freezer/wine column is
equipped with a 2-position door stop.
The factory-set 115° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is
restricted.
Door Handle Clearances
The door handle depth must be added to the dimension where noted to determine the total
clearance required from adjacent cabinets or walls. This clearance will vary depending on the custom
handle used. When using Signature Kitchen Suite handles or the Signature Kitchen Suite stainless
steel door panel kit with handles (optional accessories), the door handle clearance with the door
open 115° is 11" (279 mm).
INSTALLATION CLEARANCES
TOP VIEW
90°
115°
8 3/4"*
(223 mm
)
24"
(610 mm)
20 1/4"
(514 mm)
18"
17 3/4"
(451 mm)
3/4"
(19 mm)**
** Varies depending on the
thickness of the custom
cabinet panel. The door panels in
the optional Signature Kitchen Suite
stainless steel door panel kit are
3/4" (19 mm) thick.
Door handle must be added
to this dimension.
*
(457 mm)
1/8"
(3mm)
min.
1/8"
(3mm)
min.
90°
115°
8 3/4"*
(223 mm)
24"
(610 mm)
20 1/4"
(514 mm)
18"
17 3/4"
(451 mm)
(457 mm)
1/8"
(3mm)
min.
1/8"
(3mm)
min.
SKSCF1801P SKSCW181RP
12
SKSCF2401P – 24" INTEGRATED FREEZER COLUMN
SKSCR2401P – 24" INTEGRATED REFRIGERATOR COLUMN
SKSCW241RP – 24" INTEGRATED WINE COLUMN
NOTE
Freezer/Wine / Refrigerator column can be installed ush or proud
Flush – With a 25" (635 mm) cutout depth, the front face of the freezer/wine column ts ush with 25"
(635 mm) depth adjacent cabinets.
Proud – With a 24" (610 mm) depth cutout, the front face of the freezer/wine column extends
approximately 3/4" (19 mm) beyond 24" (610 mm) depth adjacent cabinets.
A minimum 4" (102 mm) nished return that matches the cabinet e terior is recommended on all
sides and the top of the cutout opening. The shaded area will be visible after installation.
ELECTRICAL
A 115V, 60Hz, 15 or 20 amp power supply is required. An individual, properly grounded branch
circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
WATER LINE
A cold water supply is required for automatic icemaker operation.
The water pressure must be between 20 and 120 psi.
Tubing should be long enough to extend to the front of the freezer. Allow enough tubing to
accommodate a bend leading into the water line connection.
Water line can enter an opening through the oor or back wall
Install a shut-o valve between the icemaker water valve and the cold water supply in the home.
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION, SINGLE COLUMN
24" (610 mm)
finished width
84"
(2134 mm)
5"
(127 mm)
electrical
location
4"
(102 mm)
water
location
1 3/8" (35mm)
Electrical location
Is Not available
1 3/8" (35mm)
Electrical location
Is Not available
4"
(102 mm)
finished
return*
25"(635 mm)
min. depth
flush install
24" (610 mm)
min. depth
proud install
13
ENGLISH
NOTE
Door Swing Clearances
The installation must allow for clearances to adjacent walls or cabinets. The appliances are
equipped with 2-position door stops.
The factory-set 115° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is
restricted.
Door Handle Clearances
The door handle depth must be added to the dimension where noted to determine the total clearance
required from adjacent cabinets or walls. This clearance will vary depending on the custom handle
used. When using Signature Kitchen Suite handles or the Signature Kitchen Suite stainless steel
door panel kit with handles (optional accessories), the door handle clearance with the door open
115° is 14" (356 mm).
INSTALLATION CLEARANCES
TOP VIEW
26
24
11 3/8"* 11 3/8"*
610
26
24 610
** Varies depending on the
thickness of the custom
cabinet panel. The door panels in
the optional Signature Kitchen Suite
stainless steel door panel kit are
3/4" (19 mm) thick.
Door handle must be added
to this dimension.
*
SKSCF2401P SKSCR2401P
SKSCW241RP
14
SKSCF3001P – 30" INTEGRATED FREEZER COLUMN
SKSCR3001P – 30" INTEGRATED REFRIGERATOR COLUMN
NOTE
Freezer / Refrigerator can be installed flush or proud.
Flush – With a 25" (635 mm) cutout depth, the front face of the refrigerator fits flush with 25" (635
mm) depth adjacent cabinets.
Proud – With a 24" (610 mm) depth cutout, the front face of the refrigerator extends approximately
3/4" (19 mm) beyond 24" (610 mm) depth adjacent cabinets.
* A minimum 4" (102 mm) finished return that matches the cabinet exterior is recommended on all
sides and the top of the cutout opening. The shaded area will be visible after installation.
ELECTRICAL
A 115V, 60Hz, 15 or 20 amp power supply is required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
WATER LINE
The water pressure must be between 20 and 120 psi.
Tubing should be long enough to extend to the front of the refrigerator. Allow enough tubing to
accommodate a bend leading into the water line connection.
Water line can enter an opening through the floor or back wall.
Install a shut-off valve between the water valve and cold water supply in the home.
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION, SINGLE COLUMN
30" (762 mm)
finished width
84"
(2134 mm)
5"
(127 mm)
electrical
location
4"
(102 mm)
water
location
1 3/8" (35mm)
Electrical location
Is Not available
1 3/8" (35mm)
Electrical location
Is Not available
4"
(102 mm)
finished
return*
25"(635 mm)
min. depth
flush install
24" (610 mm)
min. depth
proud install
15
ENGLISH
NOTE
Door Swing Clearances
The installation must allow for clearances to adjacent walls or cabinets. This freezer / refrigerator
is equipped with a 2-position door stop. The factory-set 115° door swing can be adjusted to 90° if
clearance to adjacent cabinets or walls is restricted.
Door Handle Clearances
The door handle depth must be added to the dimension where noted to determine the total
clearances required from adjacent cabinets or walls. This clearance will vary depending on the
custom handle used. When using Signature Kitchen Suite handles or the Signature Kitchen Suite
stainless steel door panel kit with handles (optional accessories), the door handle clearance with the
door open 115° is 16" (406 mm).
INSTALLATION CLEARANCES
TOP VIEW
3/4"
(19 mm)**
** Varies depending on the
thickness of the custom
cabinet panel. The door panels in the optional
Signature Kitchen Suite stainless steel door
panel kit are 3/4" (19 mm) thick.
Door handle must be added
to this dimension.
*
SKSCF3001P SKSCR3001P
16
SKSCF1801P – 18" INTEGRATED FREEZER COLUMN
SKSCW181RP – 18" INTEGRATED WINE COLUMN
3/4" (19 MM) CUSTOM PANEL DIMENSIONS – FLUSH INSTALLATION
Door Panel
(451 mm)
17 3/4"
47 3/4" (1213 mm)
(756 mm)
29 3/4"
DUAL 18" AND 30" COLUMN
Door Panel Door Panel 79 7/8"
(2029 mm)
79 7/8"
(2029 mm)
(451 mm)
17 3/4"
41 3/4" (1060 mm)
(603 mm)
23 3/4"
DUAL 18” AND 24” COLUMN
Door Panel Door Panel 79 7/8"
(2029 mm)
(451 mm)
17 3/4"
SINGLE COLUMN
Door
Panel
(451 mm)
17 3/4"
47 3/4" (1213 mm)
(756 mm)
29 3/4"
DUAL 18" AND 30" COLUMN
Door Panel 79 7/8"
(2029 mm)
79 7/8"
(2029 mm)
(451 mm)
17 3/4"
41 3/4" (1060 mm)
(603 mm)
23 3/4"
DUAL 18” AND 24” COLUMN
Door Panel 79 7/8"
(2029 mm)
(451 mm)
17 3/4"
SINGLE COLUMN
Door
Panel
Door
Panel
(179.5 mm)
7 1/16
"
(80.5 mm)
3 3/16
"
(238 mm)
9 3/8
"
Freezer/Refrigerator Column
Wine Column
17
ENGLISH
NOTES
Trimmed units are designed to be customized with decorative panels. Field-installed 3/4" (19 mm)
custom door panels are required.
For custom panels: Use templates provided with units to pre-drill holes for mounting panel brackets
(provided with unit). Adjustment screws and instructions also provided with units.
Maximum total door panel weight for 30" column is 64 lb.
Maximum total door panel weight for 24" column is 53 lb.
Maximum total door panel weight for 18" column is 44 lb.
DESIGN TIPS
4" (102 mm) will be visible on the interior sides of the cutout. It is recommended that the
interior of the enclosure be nished to match the exterior. For retrot/replacement installations,
the optional frame kit may be used.
If using custom panels, a custom toe kick is required.
The bottom of the case is unnished.
Door Handles: Handles are not included with the units.
Custom handles are required for installation. Brushed aluminum handles are available as an optional
accessory.
SKSPK180CS/SKSPK185CS – STAINLESS STEEL PANEL
KIT FOR 18" FREEZER COLUMN
SKSWK185RS/SKSWK185LS – STAINLESS STEEL PANEL
KIT FOR 18” WINE COLUMN
This unit can be installed with an optional stainless steel
panel kit. The freezer column kit is reversible and can be
used in both right hand and left hand door swing installations.
The wine column panel kits are not reversible.
SKSFK800CS – FRAME KIT
This unit can be installed in a 24" (610 mm) deep cutout with
an optional frame kit. The kit includes two 80" (2032 mm)
brushed aluminum side trim pieces. Each trim piece is 5"
(127 mm) deep with a 1/8" (3 mm) front face.
HANDLES FOR USE WITH CUSTOM PANELS
SKSHK310HS – 31 11/16" (805 mm) Medium Brushed
Aluminum Handle
SKSHK480HS – 48" (1219 mm) Long Brushed Aluminum
Handle
DESIGN TIPS
The stainless steel panel kit may be used in a ush 25" (635
mm) cutout depth installation or in a proud 24" (610 mm)
cutout depth installation.
The optional frame kit is recommended for retrot/
replacement installations where the existing cutout is 24"
(610 mm) deep.
OPTIONAL ACCESSORIES – FLUSH OR PROUD INSTALLATION
SKSPK180CS
SKSPK185CS
SKSWK185LS SKSWK185RS
Finishing of the handle has been
chaged from glossy to matte since April,
2022. When pair-installing a product,
Please identify the production date on
the panel installation box.
Match the production date of the
handles into before April 2022 or after
April 2022.
WARNING
18
SKSCF2401P – 24" INTEGRATED FREEZER COLUMN
SKSCR2401P – 24" INTEGRATED REFRIGERATOR COLUMN
SKSCW241RP – 24" INTEGRATED WINE COLUMN
3/4" (19 MM) CUSTOM PANEL DIMENSIONS – FLUSH INSTALLATION
(603 mm)
23 3/4"
53 3/4" (1365 mm)
(756 mm)
29 3/4"
DUAL 24" AND 30" COLUMN
Door Panel 79 7/8"
(2029 mm)
79 7/8"
(2029 mm)
47 3/4" (1213 mm)
(603 mm)
23 3/4"
DUAL 24” AND 24” COLUMN
Door Panel 79 7/8"
(2029 mm)
(603 mm)
23 3/4"
Door Panel
(603 mm)
23 3/4"
Door Panel
(603 mm)
23 3/4"
Door Panel
SINGLE COLUMN
(603 mm)
23 3/4"
53 3/4" (1365 mm)
(756 mm)
29 3/4"
DUAL 24" AND 30" COLUMN
Door Panel
79 7/8"
(2029 mm)
79 7/8"
(2029 mm)
47 3/4" (1213 mm)
(603 mm)
23 3/4"
DUAL 24” AND 24” COLUMN
Door Panel
79 7/8"
(2029 mm)
(603 mm)
23 3/4"
Door Panel
(603 mm)
23 3/4"
Door Panel
(603 mm)
23 3/4"
Door Panel
SINGLE COLUMN
(179.5 mm)
7 1/16"
(80.5 mm)
3 3/16"
(238 mm)
9 3/8"
Freezer/Refrigerator Column
Wine Column
19
ENGLISH
NOTES
Trimmed units are designed to be customized with decorative panels. Field-installed 3/4" (19 mm)
custom door panels are required.
For custom panels: Use templates provided with units to pre-drill holes for mounting panel brackets
(provided with unit). Adjustment screws and instructions also provided with units.
Maximum total door panel weight for 30" column is 64 lb.
Maximum total door panel weight for 24" column is 53 lb.
Maximum total door panel weight for 18" column is 44 lb.
DESIGN TIPS
4" (102 mm) will be visible on the interior sides of the cutout. It is recommended that the
interior of the enclosure be nished to match the exterior. For retrot/replacement installations,
the optional frame kit may be used.
If using custom panels, a custom toe kick is required.
The bottom of the case is unnished.
Door Handles: Handles are not included with the units.
Custom handles are required for installation. Brushed aluminum handles are available as an optional
accessory.
SKSPK240CS/SKSPK245CS – STAINLESS STEEL PANEL
KIT FOR 24" FREEZER / REFRIGERATOR COLUMN
SKSWK245RS/SKSWK245LS – STAINLESS STEEL PANEL
KIT FOR 24" WINE COLUMN
This unit can be installed with an optional stainless steel
panel kit. The freezer/refrigerator column kit is reversible
and can be used in both right hand and left hand door swing
installations. The wine column panel kits are not reversible.
SKSFK800CS – FRAME KIT
This unit can be installed in a 24" (610 mm) deep cutout with
an optional frame kit. The kit includes two 80" (2032 mm)
brushed aluminum side trim pieces. Each trim piece is 5"
(127 mm) deep with a 1/8" (3 mm) front face.
HANDLES FOR USE WITH CUSTOM PANELS
SKSHK310HS – 31 11/16" (805 mm) Medium Brushed
Aluminum Handle
SKSHK480HS – 48" (1219 mm) Long Brushed Aluminum
Handle
DESIGN TIPS
The stainless steel panel kit may be used in a ush 25" (635
mm) cutout depth installation or in a proud 24" (610 mm)
cutout depth installation.
The optional frame kit is recommended for retrot/
replacement installations where the existing cutout is 24"
(610 mm) deep.
OPTIONAL ACCESSORIES – FLUSH OR PROUD INSTALLATION
SKSPK240CS
SKSPK245CS
SKSWK245LS SKSWK245RS
Finishing of the handle has been
chaged from glossy to matte since April,
2022. When pair-installing a product,
Please identify the production date on
the panel installation box.
Match the production date of the
handles into before April 2022 or after
April 2022.
WARNING
20
SKSCF3001P – 30" INTEGRATED FREEZER COLUMN
SKSCR3001P – 30" INTEGRATED REFRIGERATOR COLUMN
NOTES
Trimmed units are designed to be customized with decorative panels. Field-installed 3/4" (19 mm)
custom door panels are required.
For custom panels: Use templates provided with units to pre-drill holes for mounting panel brackets
(provided with unit). Adjustment screws and instructions also provided with units.
Maximum total door panel weight for 30" column is 64 lb.
Maximum total door panel weight for 24" column is 53 lb.
Maximum total door panel weight for 18" column is 44 lb.
DESIGN TIPS
4" (102 mm) will be visible on the interior sides of the cutout. It is recommended that the interior
of the enclosure be finished to match the exterior. For retrofit/replacement installations, the
optional frame kit may be used.
If using custom panels, a custom toe kick is required. The bottom of the case is unfinished.
Door Handles: Handles are not included with the units. Custom handles are required for installation.
Brushed aluminum handles are available as an optional accessory.
3/4" (19 MM) CUSTOM PANEL DIMENSIONS – FLUSH INSTALLATION
Door Panel
(756 mm)
29 3/4" 59 3/4" (1518 mm)
(756 mm)
29 3/4"
DUAL 30" AND 30" COLUMN
Door Panel 79 7/8"
(2029 mm)
79 7/8"
(2029 mm)
(756 mm)
29 3/4"
Door Panel
SINGLE COLUMN
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148

Signature Kitchen Suite SKSCW241RP Guide d'installation

Taper
Guide d'installation