Miller H8HK Information produit

Taper
Information produit
MAIN AIR
LIMIT
AC RELAY
DC RELAY ELEMENT
BACK UP
LIMIT
2
1
12
7-PIN PLUG
2-PIN
POWER PLUG
CIRCUIT
BREAKER
(Circuit breaker
models only)
SUPPLY VOLTAGE
COM
NO
COM
NO
CONNECT TO C ON
CONTROL BOARD
CONNECT TO ONE OF THE
BLUE BLOWER LIMIT LEADS
IN THE AIR HANDLER, IF
PRESENT.
THEN CONNECT THE OTHER
BLUE BLOWER LIMIT LEAD
TO W1 ON THE CONTROL
BOARD.
IF BLOWER LIMIT LEADS ARE
NOT PRESENT, CONNECT TO
W1 ON CONTROL BOARD.
BLACK
RED
ORANGE
GREY
BLACK
RED
BLACK
RED RED
WHITE
GREY
RED
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
WIRING DIAGRAM
NOTES:
1. If any of the original wire supplied with this unit
must be replaced, it must be replaced with wiring
material of the same gauge size and temperature
rating.
2. The installation of this heater kit may require a change
in the blower speed tap connection. See Installation
Instructions for details.
3. Use copper conductors with a minimum temperature
rating of 60°C for supply connections.
5 kW, 208/230 V~, 60Hz, 1-Phase Electric Heater KitH8HK005K-01D (with circuit breaker)
H8HK005K-11D (without circuit breaker)
1045660A
(10456600)
11/23
Remarques:
1. Si le câblage interne est remplacé, utilisez seulement un fil
de cuivre 105° C du même gabarit.
2. Pour le chaufferettes électiques installées sur le terrain,
peut nécessiter un changement dans le connecteur de
vitesse du moteur du ventilateur. Consultez les Instructions
d’installation.
3. Employez uniquement des conducteurs en cuivre.
  • Page 1 1

Miller H8HK Information produit

Taper
Information produit

dans d''autres langues