Tetra® PowerStrip DS
LED Lighting System
Installation Guide
SIGN067 | GE2028-2617
GEDS71-2, GEDS50-2, GEDS41-2, GEDS32-2,
GEDSH71-3, GEDSH50-3, GEDSH41-3, GEDSH32-3
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power o before inspection, installation or removal.
Properly ground power supply enclosure.
RISK OF FIRE
Use only UL approved wire for input/output connections.
Minimum size 18 AWG (0.82mm2)
Follow all NEC and local codes.
Not to be submerged or used in a marine environment.
RISK OF FIRE OR ELECTRIC SHOCK
LED Retrot Kit installation requires knowledge of
sign electrical systems. If not qualied, do not attempt
installation. Contact a qualied electrician.
Install this kit only in host signs that have been identied in
the installation instructions and where the input rating of the
retrot kit does not exceed the input rating of the sign.
Installation of this LED retrot kit may involve drilling or
punching of holes into the structure of the sign. Check
for enclosed wiring and components to avoid damage to
wiring and electrical parts.
Do not make or alter any open holes in an enclosure of
wiring or electrical components during kit installation.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
Assurez-vous de correctement mettre à terre l’alimentation électrique.
RISQUES D’INCENDIE
N’utilisez que des ls approuvés par UL pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82mm2)
Respectez tous les codes NEC et codes locaux.
Ne pas submerger ou installer dans un environnement marin.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE
L’installation de l’équipement de remplacement DEL exige Ia connaissance des
systèmes électriques pour enseignes. Si non qualié, ne tentez pas d’installation.
Veuillez contacter un électricien qualié.
Risque d’incendie ou de choc Électrique. Installez cet ensemble seulement dans des
enseignes hôtes qui ont été identiés dans les instructions d’installation et dont la
capacité d’entrée de l’ensemble ne dépasse pas la capacité d’entrée de l’enseigne.
L’installation de cet équipement de remplacement DEL peut impliquer le perçage
ou le poinçonnage de trous dans la structure du panneau Vériez le câblage et les
composants inclus pour éviter d’endommager le câblage et les composants électriques.
Ne pas faire ou modier les trous ouverts dans une enceinte de câblage
ou de composants électriques pendant l’installation de cet équipement de
remplacement DEL.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
CAUTION / ATTENTION
RISK INJURY
While performing installations described, gloves, safety glasses or
goggles should be worn.
RISQUES DE BLESSURE
Lors de l’exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
Save These Instructions
Use only in the manner intended by the manufacturer. If
you have any questions, contact the manufacturer.
RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY
IN ACCORDANCE WITH KIT INSTRUCTIONS.
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED
BY THE INSTRUCTIONS ARE PRESENT.
TROUSSE DE CONVERSION À DEL POUR LA
MODERNISATION DES ENSEIGNES
À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.
Prepare Electrical Wiring
Electrical Requirements
Limited to use in dry and damp locations.
The grounding and bonding of the LED Driver shall be done in
accordance with National Electric Code (NEC) Article 600.
Follow all National Electric Codes (NEC) and local codes.
These products are only suitable for connection to a circuit
from a Class 2 power source.
These products have not been evaluated for use when
connected to a power source that does not comply with Class
2 voltage and energy limited supplies.
2424
Volt
Tetra® PowerStrip DS Installation Guide
2
Layout Recommendations
Tetra® Module Depth Stroke Width
Mod to Mod
Spacing
Double Sided
PowerStrip and
Double Sided
Powerstrip High
Output
10-12” (254-305mm) 10” (254mm) 12” (305mm)
12-14” (305-356mm) 12” (305mm) 12” (305mm)
14-16” (356-406mm) 13” (330mm) 13” (330mm)
16-18” (406-457mm) 14” (356mm) 14” (356mm)
18-20” (457-508mm) 15” (381mm) 15” (381mm)
20-22” (508-559mm) 16” (406mm) 16” (406mm)
22-24” (559-610mm) 17” (432mm) 16” (406mm)
Powerstrip DS HO 24-36” (610-914mm) 18” (457mm) 16” (406mm)
36” (914mm) 12” (305mm) 16” (406mm)
Row
spacing
Sign
depth
NOTE: Minimum recommended sign depth is 10 inches (254 mm).
Sign
Measure inside
Tetra® Mounting Rail
Measure and cut Tetra® Mounting
Rail or other suitable mounting
means to appropriate length to t
into sign.
Secure the Mounting Rail to the
inside of the box sign using a
Tetra® Mounting Rail Clip or other
suitable mounting means. Ensure
the #6 (M3) screw does not exceed
3/4 inches (19 mm) in length.
Installation: Sign Using Rails
Arrange modules evenly spaced
apart. Place the Tetra® modules
on the Mounting Rail and secure
into lip with a self-tapping #6 (M3)
screw or 1/8-inch (3.175 mm) rivet.
Or mount using the alternative clip
and extender rod conguration.
Components
Alternative clip
and extender rod
Electrical grade RTV silicone.
Example electrical grade RTV silicones include:
Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant
Momentive White Blanc RTV 162 Silicone Rubber Adhesive Sealant-Electrical Grade
Dow Corning 3140 - Non-Corrosive Flowable (clear)
Dow Corning 3145 - Non-Corrosive Nonowable (clear or gray)
Dow Corning RTV 748 Non-Corrosive Sealant-White
UL certied 18 AWG (0.82 mm2)
supply wire
UL certied 22-14 AWG (0.33-2.08
mm2) wire connectors or 18-14
AWG (0.82-2.08 mm2) inline/IDC
connectors
#6 x .75 inch (M3 x 19mm) self-
tapping screws
End caps
24 VDC Power Supply
Tetra® Mounting Rail
Tetra® Assembly Bracket or
Mounting Rail Clip
Tetra® Angle Mounting Clips and
Extender Rod
TC Measure Point
Tetra® PowerStrip DS MO LED modules
Tetra® PowerStrip DS High Output LED
modules
1 7
7
8
8
9
9
10
10
11
11
12
2
3
3
4
4
5
5
6
6
Optional
1 2 3
Tetra® PowerStrip DS Installation Guide
3
Power
Supply
To LED System
Red (+)
Black or blue (-)
Run a wire from the power supply to inside the sign
and connect to the rst module on the strip.
NOTE:
Exceeding maximum load will cause the power
supply to shut down. If overload occurs, remove excess
load, recycle the input power to restart the power supply.
Connect the red stripe wire (+) of the LED system to
the red wire (+) of the power supply. Connect the white
wire (-) of the LED system to the black or blue wire (-)
of the power supply.
Connect modules using twist-on wire connectors or
in-line (IDC) connectors. Join white wires together
and red striped wires together.
NOTE: Additional supply wire may be necessary to
bridge electrical connections.
Cap all exposed wires with appropriate end caps
or apply electric grade (non-corrosive) silicone for
additional weather protection.
Electrical Connections
Red stripe (+)
White (-)
To Power Supply
Red (+)
Red stripe (+)
White (-)
Black or blue (-)
NOTE: Do not use connectors pre-lled with silicone grease/mineral base protective grease or use silicone grease to seal connections.
NOTE: All electrical connections should be suitably
protected from mechanical damage and the
environment. Seal all connections in locations that may
be exposed to water with electrical grade RTV silicone.
1
3
2
4
Tetra® PowerStrip DS Installation Guide
4
Troubleshooting
Symptom Solution
Row of modules does not light Check wire connections to power supply to ensure red stripe-to-red and white-to-black or blue
connections.
Check row-to-row polarity connections.
Sign does not light Check input and output voltage and check power supply input/output connections.
Check polarity connections.
Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
Individual modules do not light Remove module and replace with another working module.
Modules are dim Ensure the overall length of the Tetra® LED system does not exceed the maximum load.
Ensure the length and gauge of the supply wire is equal to or below the recommended remote
mounting distance.
Retrot Instructions
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the
building. Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED
power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes
(whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or uorescent tubes; and
associated transformers and ballasts. Care should be taken not to break the existing neon or uorescent tubes.
NOTE: Follow all federal and local regulations when disposing of neon tubing, uorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable
local, state, or country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in)
diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed
with non-hardening caulk.
5. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
6. A 24VDC Class 2 Power Supply, as listed below, must be used with this retrot kit. Using the Maximum Loading chart below,
determine the number of Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to
overload the Power Supply chosen.
7. Follow the instructions above to properly mount the LED modules.
8. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
9. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions
found in the power supply installation guide.
10. If required, the disconnect switch shall be installed by qualied personnel, in accordance with applicable local, state, and country
electrical codes.
Tetra® PowerStrip DS Installation Guide
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
SIGN067 (Rev 06/29/21) GE2028-2617
18 AWG/0.82 mm2
Supply Wire
16 AWG/1.31 mm2
Supply Wire
14 AWG/2.08 mm2
Supply Wire
12 AWG/3.31 mm2
Supply Wire
25W Power Supply 120 ft./36.6 m –––
80W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
100W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
180W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
200W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
300W Power Supply 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.
Conforms to the following standards:
If you have any questions about these instructions or your specic application, please contact support at [email protected].
For the latest install guides for your product go to: www.gecurrent.com
Maximum Remote Mounting Distance
Maximum Loading per 24 VDC Class 2 Power Supply
Power Supply
GEDS71-2, GEDS50-2,
GEDS41-2, GEDS32-2
GEDSH71-3, GEDSH50-3,
GEDSH41-3, GEDSH32-3
Rating per module 24VDC, 5.04W/module 24VDC, 5.9W/module
GEPS24-25U-NA
Load shall not exceed 1.04A 4 modules 3 modules
GEPS24D-80U, GEPS24W-80
Load shall not exceed 3.3A 14 modules 12 modules
GEPS24-100U-GLX, USVI-100024FBA, USVI-100024FE
Load shall not exceed 4.0A 18 modules 16 modules
GEPS24-180U
Load shall not exceed 3.8A per each (of 2) output channels
16 modules per bank
32 modules per PS 14 modules per bank
28 modules per PS
GEPS24-300U-GL
Load shall not exceed 4.0A per each (of 3) output channels
18 modules per bank
54 modules per PS 16 modules per bank
48 modules per PS
GEPS24-100U-GLX2/TT
Load shall not exceed 4.0A 18 modules 15 modules
GEPS24-200U-GLX2
Load shall not exceed 4.0A per each (of 2) output channels
18 modules per bank
36 modules per PS 15 modules per bank
30 modules per PS
GEPS24-300U-GLX2
Load shall not exceed 4.0A per each (of 3) output channels
18 modules per bank
54 modules per PS 15 modules per bank
45 modules per PS
  • Page 1 1