EPA Certied Emissions 1.4 grams per hour
LHV Tested Efciency 1 72%
HHV Tested Efciency 2 67%
EPA BTU Output 3 11,000 to 51,500 btu/hr
Peak BTU/Hr Output 4
Maximum Wood Length 17 inches
Ideal Wood Length 16 inches
Fuel Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using CSA
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using
Douglas Fir dimensional lumber.
Efficiency and BTU Output
This heater meets the U.S. Environmental Protection Agency's 2020 Cord wood emission limits for wood
heaters sold after May 15, 2020 Tested to ASTM 3053.
Under specic test conditions this heater has been shown to deliver heat at rates ranging from 11,000 to
51,500Btu/hr. Emissions testing was performed by PFS-TECO Inc.
For instructions on locating and accessing the Rating label, see page 33.
Rating Label
CLEARANCES TO SIDE AND BACK STANDOFFS/ DÉGAGEMENTS 0 in. / 0 mm
C. CORNER TO SIDEWALL/ COIN AU MUR LAT. 3.1 in. / 79mm
D. FRAMING OPENING/ OVERTURE DE CADRAGE 56 in./1.42m
E. CEILING TO UNIT/ DU PLAFOND AU FOYER 38-3/4 in. / 986mm
NON-COMBUSTIBLES ONLY IN THE SPACE ABOVE UNIT TO CEILING, NOT INCLUDING
APPROVED FRAMING / NON-COMBUSTIBLES SEULEMENT AU-DESSUS FOYER À PLAFOND
F. BASE OF UNIT TO MANTEL/ BASE DE L’UNITÉ AU MANTEAU
G. EMBER PROTECTION FROM FRONT OF UNIT/ PROTECTEUR de PLANCHER À
L’AVANT DU FOYER 18 in. / 457 mm
H. EMBER PROTECTION TO SIDE OF UNIT/ PROTECTEUR de PLANCHER AU CÔTÉ
DU FOYER 8 in./203 mm
IN USA: (Type 1 fl oor protector - approved to UL1618)Equal to Minimum 20GA steel
DO NOT REMOVE THIS LABEL/ NE RETIREZ PAS CETTE IQUETTE
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS/ DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX COMBUSTIBLES
SN-
100003892 200320
MANTEL HEIGHT MUST BE MEASURED FROM THE BASE OF THE UNIT AS FOLLOWS:
48 1/8 in.(1.22m) FOR ALL MANTEL DEPTHS FROM 2”(51mm) TO 12”(305mm).///
LA HAUTEUR DU MANTEAU, MESURÉE DE LA BASE DE L’APPAREIL, DOIT ÊTRE DE 48-1/8po (1,22 m)
POUR LES MANTEAUX AYANT UNE PROFONDEUR DE 2 po (51 mm) À 12 po (305 mm).
***
***
MODEL/ MODÈLE: FP25 LE FP25AR LE
LISTED FACTORY BUILT FIREPLACE, also for use in Mobile Home.
CERTIFIED TO / CERTIFIÉ POUR:
ULC S610-M87 AND UL 127-2011 for CANADA AND U.S.A.
ETL#4001507
Refer to Intertek’s Directory of Building Products for detailed information
•
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629,
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629,
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
• LES PARTIES DU FOYER INCORPORANT DES CONDUITS CHAUDS OU FROIDS DOIVENT ÊTRE ENCHÂSSÉES, CONFORMÉMENT AUX IN-
STRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
• CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE POUR LES RESTRICTIONS, PERMIS
D’INSTALLATION ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION.
• NE RACCORDEZ PAS CE FOYER À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.
• NE PAS OBSTRUER PAS LES OUVERTURES DEVANT LE FOYER, NI RESTREINDRE L’ALIMENTATION D’AIR NÉCESSAIRE POUR LE FONC-
TIONNEMENT NORMAL DU FOYER, TEL QUE SPÉCIFIÉ DANS LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC
L’APPAREIL. LA PROVISION INADEQUATE D’AIR POUR COMBUSTION, MAI DE VENTILATION ET DILUTION A POUR RESULTAT L’OPERATION
DANGEREUSE DE CECI ET AUTRES APPAREILS.
• VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT, POUR LES PRÉCAUTIONS EXIGÉES LORSQU’UNE CHEMINÉE
TRAVERSE UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES.
• REMPLACEZ LA VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE. • LA SOUFFLERIE CLASSEMENT ELECTRIQUE 115V, 60 Hz, 1.1AMP
• CETTE CHEMINEE n’A pas ETE ESSAYEE AVEC UN UNVENTED JOURNAL DE GAZ A REGLE. POUR REDUIRE LE RISQUE DE FEU OU BLES-
SURE, LE PAS INSTALLE UN UNVENTED JOURNAL DE GAZ A REGLE DANS CHEMINEE.
• UTILISEZ SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE. NE L’OUVREZ QUE POUR ALIMENTER LE FEU.
• CE FOYER PEUT ÊTRE INSTALLÉ DANS UNE MAISON PRÉFABRIQUÉE. UTILISER DU BOIS SOLIDE SEULEMENT.
• POUR COMBUSTIBLE SOLIDE SEULEMENT.
• COMPOSANTS OPTIONNELS: KIT DE CONDUITS DE DISTRIBUTION DE CHALEUR (PIÈCE no WODC.RHKA).
• UTILISEZ LES COMPOSANTS SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION DE PACIFIC ENERGY.
MANUFACTURED BY/ FABRIQUÉ PAR :
PACIFIC ENERGY FIREPLACE PRODUCTS
LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
MADE IN CANADA
/ FABRIQUÉ AU CANADA
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certifi ed to comply with 2020 particulate
emission standards,
using Cordwood.
Tested to ASTM 3053 1.4g/hr.
DATE OF MANUFACTURE
•
ALSO FOR USE IN MANUFACTURED HOMES WITH SOLID WOOD FUEL ONLY
• INSTALL AND USE IN ACCORDANCE WITH THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE
• AREAS OF THE FIREPLACE INCORPORATING WARM OR COLD AIR DUCTS SHALL BE ENCLOSED IN ACCORDANCE WITH THE INSTALLA-
TION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
• DO NOT OBSTRUCT THE OPENINGS IN FRONT OF THE FIREPLACE OR OTHERWISE RESTRICT SUPPLY AIR NECESSARY FOR NORMAL
FIREPLACE OPERATION AS SPECIFIED IN INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE. INADEQUATE
AIR SUPPLY FOR COMBUSTION, VENTILATION AND DILUTION MAY RESULT IN DANGEROUS OPERATION OF THIS AND OTHER APPLIANCES.
• CHIMNEY SYSTEM MUST BE LISTED TO:
ULC S-629 IN CANADA / UL-103 HT IN USA -
ULC S-629 IN CANADA / UL-103 HT IN USA - SEE LOCAL BUILDING CODE AND MANUFACTURER'S
INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• OPTIONAL COMPONENTS: REMOTE HEAT KIT PART# WODC.RHKA.
• USE SOLID WOOD FUEL ONLY. OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
• BLOWER ELECTRICAL RATING 115V, 60HZ, 1.1AMP • REPLACE GLASS ONLY WITH 5mm CERAMIC GLASS.
• DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
• DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT.
• THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN
UNVENTED GAS LOG SET INTO FIREPLACE.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
• - CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION.
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTANT WITH THE OPERATING
INSTRUCTIONS IN THE OWNER’S MANUAL.