Lincoln Electric AutoDrive 4R90 Manuel utilisateur

Catégorie
Système de soudage
Taper
Manuel utilisateur
OPERATOR’S MANUAL
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © Lincoln Global Inc.
AutoDrive 4R90
IM952-A
March, 2010
For use with machines having Code Number : 11492, 11722
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built with
safety in mind. However, your overall
safety can be increased by proper
installation ... and thoughtful opera-
tion on your part. DO NOT
INSTALL, OPERATE OR REPAIR
THIS EQUIPMENT WITHOUT
READING THIS MANUAL AND
THE SAFETY PRECAUTIONS
CONTAINED THROUGHOUT. And,
most importantly, think before you
act and be careful.
FOR ENGINE
powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated
areas or vent the engine exhaust fumes
outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame
welding arc or when the engine is running.
Stop the engine and allow it to cool before
refueling to prevent spilled fuel from vaporiz-
ing on contact with hot engine parts and
igniting. Do not spill fuel when filling tank. If
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in
position and in good repair.Keep hands, hair, clothing and
tools away from V-belts, gears, fans and all other moving
parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.
___________________________________________________
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.
i
SAFETY
i
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available
from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
WARNING
Mar ‘95
ELECTRIC AND
MAGNETIC FIELDS
may be dangerous
2.a. Electric current flowing through any conductor causes
localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines
2.b. EMF fields may interfere with some pacemakers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health
effects which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as
possible to the area being welded.
2.d.5. Do not work next to welding power source.
1.h. To avoid scalding, do not remove the
radiator pressure cap when the engine is
hot.
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents
are known to the State of California to cause can-
cer, birth defects, and other reproductive harm.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
The Above For Diesel Engines
The Above For Gasoline Engines
ii
SAFETY
ii
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
plates to protect your eyes from sparks and
the rays of the arc when welding or observing
open arc welding. Headshield and filter lens
should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
ELECTRIC SHOCK can
kill.
3.a. The electrode and work (or ground) circuits
are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground.
In addition to the normal safety precautions, if welding
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use
the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic
welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection
should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically hot parts of
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
of both welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
FUMES AND GASES
can be dangerous.
5.a. Welding may produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases. When welding, keep
your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special
ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
cadmium plated steel and other metals or coatings
which produce highly toxic fumes, keep exposure as
low as possible and within applicable OSHA PEL and
ACGIH TLV limits using local exhaust or mechanical
ventilation. In confined spaces or in some circum-
stances, outdoors, a respirator may be required.
Additional precautions are also required when welding
on galvanized steel.
5. b. The operation of welding fume control equipment is affected
by various factors including proper use and positioning of
the equipment, maintenance of the equipment and the spe-
cific welding procedure and application involved. Worker
exposure level should be checked upon installation and
periodically thereafter to be certain it is within applicable
OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon
vapors
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors
to
form phosgene, a highly toxic gas, and other irritating prod-
ucts.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
5.e. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employer’s safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
Jan ‘09
iii
SAFETY
iii
FOR ELECTRICALLY
powered equipment.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturer’s
recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
CYLINDER may explode
if damaged.
7.a. Use only compressed gas cylinders
containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
Away from areas where they may be struck or subjected to
physical damage.
A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand
tight except when the cylinder is in use or connected for
use.
7.g. Read and follow the instructions on compressed gas
cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
WELDING and CUTTING
SPARKS can
cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
the welding sparks from starting a fire.
Remember that welding sparks and hot
materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.
6.c. When not welding, make certain no part of the electrode
circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even
though
they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the
Preparation
for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
6.f.
Sparks and spatter are thrown from the welding arc. Wear oil
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.
6.g. Connect the work cable to the work as close to the welding
area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate cir-
cuits. This can create fire hazards or overheat lifting chains
or cables until they fail.
6.h. Also see item 1.c.
6.I. Read and follow NFPA 51B Standard for Fire Prevention
During Welding, Cutting and Other Hot Work”, available
from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma
022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Jan ‘09
Refer to http://www.lincolnelectric.com/safety for additional safety information.
iv
SAFETY
iv
Mar. ‘93
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions
et les précautions de sûreté specifiques qui parraissent dans ce
manuel aussi bien que les précautions de sûreté générales suiv-
antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours
tout contact entre les parties sous tension et la peau nue
ou les vétements mouillés. Porter des gants secs et sans
trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher
metallique ou des grilles metalliques, principalement dans
les positions assis ou couché pour lesquelles une grande
partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et r état
defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder
parce que la tension entre les deux pinces peut être le
total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions
pour le porte-électrode s’applicuent aussi au pistolet de
soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger
contre les chutes dans le cas ou on recoit un choc. Ne jamais
enrouler le câble-électrode autour de n’importe quelle partie
du corps.
3. Un coup d’arc peut être plus re qu’un coup de soliel,
donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray-
onnement de l’arc et des projections quand on soude ou
quand on regarde l’arc.
b. Porter des tements convenables afin de proger la
peau de soudeur et des aides contre le rayonnement de
l‘arc.
c. Protéger lautre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de larc de
soudage. Se protéger avec des vêtements de protection libres
de l’huile, tels que les gants en cuir, chemise épaisse, pan-
talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécuri dans la zone de
soudage. Utiliser des lunettes avec écrans lateraux dans les
zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de
prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de
la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible
de la zone de travail qu’il est pratique de le faire. Si on place
la masse sur la charpente de la construction ou d’autres
endroits éloignés de la zone de travail, on augmente le risque
de voir passer le courant de soudage par les chaines de lev-
age, câbles de grue, ou autres circuits. Cela peut provoquer
des risques d’incendie ou d’echauffement des chaines et des
câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles
galvanisées plombées, ou cadmiées ou tout autre métal qui
produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant
d’opérations de graissage, nettoyage ou pistolage. La
chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs
du solvant pour produire du phosgéne (gas fortement toxique)
ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté,
voir le code “Code for safety in welding and cutting” CSA
Standard W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de
l’électricité et aux recommendations du fabricant. Le dispositif
de montage ou la piece à souder doit être branc à une
bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront
effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch-
er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûre à leur
place.
vv
TThhaannkk YYoouu
for selecting a QUALITY product by Lincoln Electric. We want you
to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
CAUTION
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.
Please record your equipment identification information below for future reference. This information can be
found on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you
have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet
accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
WEB SITE at www.lincolnelectric.com. Choose “Quick Links” and then
“Product Registration”. Please complete the form and submit your registration.
CUSTOMER ASSISTANCE POLICY
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip-
ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln
Electric for advice or information about their use of our products. We respond to our customers based on the best information in our posses-
sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor-
mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose,
with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or
correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any
warranty with respect to the sale of our products.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control
of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in
applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com
for any updated information.
vi
vi
TABLE OF CONTENTS
Page
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Installation.......................................................................................................................Section A
Technical Specifications.......................................................................................................A-1
Safety Precautions ...............................................................................................................A-2
Location................................................................................................................................A-2
Weld Cable Sizes .................................................................................................................A-2
Coaxial Weld Cable..............................................................................................................A-3
Wire Drive Cable .................................................................................................................A-4
Shielding Gas Connection....................................................................................................A-5
Wire Drive Configuration ......................................................................................................A-6
Changing The Gun Receiver Bushing..................................................................................A-6
Procedure to Install Drive Rolls and Wire Guides ................................................................A-7
Conduit Installation...............................................................................................................A-8
System Set-Up .....................................................................................................................A-9
________________________________________________________________________________
Operation.........................................................................................................................Section B
Safety Precautions ...............................................................................................................B-1
Graphic Symbols that appear on this Machine or in this Manual .........................................B-1
Definition of Welding Terms .................................................................................................B-2
Product Description ..............................................................................................................B-2
Recommended Processes, Equipment Limitations, Recommended Power Sources ..........B-2
________________________________________________________________________________
Accessories ....................................................................................................................Section C
Optinal Kits and Accessories ...............................................................................................C-1
Drive Roll Kits used..............................................................................................................C-1
Accessories Used.........................................................................................................C-2, C-3
________________________________________________________________________________
Maintenance....................................................................................................................Section D
Safety Precautions ...............................................................................................................D-1
Routine Maintenance ...........................................................................................................D-1
Periodic Maintenance...........................................................................................................D-1
Calibration Specification.......................................................................................................D-1
________________________________________________________________________________
Troubleshooting .............................................................................................................Section E
How to Use Troubleshooting Guide .....................................................................................E-1
Troubleshooting Guide .................................................................................................E-2, E-3
________________________________________________________________________________
Wiring Diagram & Dimension Prints .............................................................................Section F
________________________________________________________________________________
Parts Pages ................................................................................................................P-569 Series
_______________________________________________________________________
________
A-1
INSTALLATION
A-1
AutoDrive 4R90
TEMPERATURE RANGE
OPERATION: -40°F to 104°F (-40°C to 40°C)
STORAGE: -40°F to 185°F (-40°C to 85°C)
INPUT VOLTAGE, CURRENT
TECHNICAL SPECIFICATIONS –
AutoDrive 4R90 (K2685-2)
HEIGHT WIDTH LENGTH WEIGHT
8.4 Inches 7.5 Inches 9.1 Inches 13.2 lbs
(213 mm) ( 191 mm) (231 mm) (6.0 kg)
PHYSICAL DIMENSIONS
INPUT VOLTAGE ± 10%
0-40 VDC
INPUT AMPERES
4A
RATED OUTPUT @ 104°F (40°C)
DUTY CYCLE
100% rating
INPUT AMPERES
500
GEARING - WIRE FEED SPEED RANGE-WIRE SIZE
WFS RANGE
50 – 800 ipm
(1.3 – 20.3m/min)
WFS RANGE
50 – 800 ipm
(1.3 – 20.3m/min)
WIRE SIZES
.023 – .045"
(0.6 – 1.2mm)
WIRE SIZES
.035 - .045”
(0.9 – 1.2mm)
GEARING
K2685-2
GMAW
FCAW
WELD CABLE SIZE
Table A.1 located below are copper cable sizes rec-
ommended for different currents and duty cycles.
Lengths stipulated are the distance from the welder to
work and back to the welder again. Cable sizes are
increased for greater lengths primarily for the purpose
of minimizing cable drop.
** Tabled values are for operation at ambient temperatures of 104°F(40°C) and below. Applications above 104°F(40°C) may require cables
larger than recommended, or cables rated higher than 167°F(75°C).
RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 167°F or 75°C)**
CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES
AMPERES
200
200
225
225
250
250
250
250
300
325
350
400
400
500
PERCENT
DUTY
CYCLE
60
100
20
40 & 30
30
40
60
100
60
100
60
60
100
60
0 to 50Ft.
(0 to15m)
2
2
4 or 5
3
3
2
1
1
1
2/0
1/0
2/0
3/0
2/0
50 to 100Ft.
(15 to 30m)
2
2
3
3
3
2
1
1
1
2/0
1/0
2/0
3/0
2/0
100 to 150 Ft.
(30 to 46m)
2
2
2
2
2
1
1
1
1
2/0
2/0
2/0
3/0
3/0
150 to 200 Ft.
(46 to 61m)
1
1
1
1
1
1
1
1
1/0
2/0
2/0
3/0
3/0
3/0
200 to 250 Ft.
(61 to 76m)
1/0
1/0
1/0
1/0
1/0
1/0
1/0
1/0
2/0
3/0
3/0
4/0
4/0
4/0
TABLE A.1
A-2
INSTALLATION
AutoDrive 4R90
A-2
SAFETY PRECAUTIONS
ELECTRIC SHOCK CAN KILL.
• Turn the input power OFF at the
welding power source before
installation or changing drive rolls
and/or guides.
• Do not touch electrically live parts.
When inching with the gun trigger,
electrode and drive mechanism are
"hot" to work and ground and
could remain energized several
seconds after the gun trigger is
released.
• Welding power source must be connected to
system ground per the National Electrical Code
or any applicable local codes.
• Only qualified personnel should perform mainte-
nance work.
------------------------------------------------------------------------
WARNING
A-3
INSTALLATION
AutoDrive 4R90
A-3
COAXIAL WELD CABLE
Coaxial welding cables are specially designed welding
cables for STT™ and pulse welding. Coaxial weld cables
feature low inductance, allowing fast changes in the weld
current. Regular cables have a higher inductance which
may distort the STT™ waveshape. Inductance becomes
more severe as the weld cables become longer.
Coaxial weld cables are recommended for STT™ weld-
ing, especially when the total weld cable length (elec-
trode cable + work cable) exceeds 50 feet (7.6m). See
Table A.2.
A coaxial weld cable is constructed with multiple small
leads wrapped around one large lead. The large inner
lead connects to the electrode stud on the power source
and the electrode connection on the wire feeder. The
small leads combine together to form the work lead, one
end attached to the power source and the other end to
the work piece.
To install:
1. Turn the input power off at the welding power source.
2. Connect one end of the center lead to the power
source electrode connection, and the other end to the
wire feeder electrode connection.
3. Connect the outer lead bundle to the power source
work connection, and the other end to the work piece.
Minimize the length of any work lead extension for
best results.
4. Insulate all connections.
ElectrodeElectrode
WWorkork
Amperes
250
300
350
Duty
Cycle
100%
60%
60%
0 to 25 Ft.
1
1
1/0
25 to 50 Ft.
1
1
1/0
50 to 75 Ft.
1
1
--
75 to 100 Ft.
1
1/0
--
COAXIAL CABLE LENGTH
RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 75°C)**
ElectrodeElectrode
WorkWork
ElectrodeElectrode
WorkWork
Power SourcePower Source
Coaxial Weld CableCoaxial Weld Cable
Wire FeederWire Feeder
TABLE A.2
** Tabled values are for operation at ambient temperatures of 104°F(40°C) and below.
Applications above 104°F(40°C) may require cables larger than recommended, or cables rated
higher than 167°F(75°C).
A-4
INSTALLATION
AutoDrive 4R90
A-4
A
B
K
H
N
L
C
D
M
G
F
E
J
I
POWER SOURCE
WIRE FEEDER
A
B
K
H
N
L
C
D
M
G
F
E
J
I
Function
Motor Power
Motor Power
Gas Solenoid
Gas Solenoid
Reserved
Reserved
“2A” Differential Tachometer
“2B” Differential Tachometer
Reserved
Reserved
“1A” Differential Tachometer
“1B” Differential Tachometer
Reserved
“67” Electrode Sense Lead
Pin
A
B
C
D
E
F
G
H
I
J
K
L
M
N
WIRE DRIVE CABLE, K1785-XX
Wire drive cables are used to connect power sources
and control boxes to remote wire drives.
The cables have a 14 pin connector at each end.
Both ends of the cable have a collar and the cables
cannot be “daisy chained” to make a longer cable.
Function
Motor Power
Motor Power
Gas Solenoid
Gas Solenoid
“2A” Differential Tachometer
Reserved
+15VDC Tech Supply
Tachometer Common
Reserved
Reserved
“1A” Differential Tachometer
“1B” Differential Tachometer
“2B” Differential Tachometer
“67” Electrode Sense Lead
Pin
A
B
C
D
E
F
G
H
I
J
K
L
M
N
POWER SOURCE
WIRE FEEDER
A-5
INSTALLATION
AutoDrive 4R90
A-5
SHIELDING GAS CONNECTION
CYLINDER may explode if
damaged.
Keep cylinder upright and
chained to support.
• Keep cylinder away from areas where it may be
damaged.
• Never lift welder with cylinder attached.
• Never allow welding electrode to touch cylinder.
• Keep cylinder away from welding or other live
electrical circuits.
• BUILD UP OF SHIELDING GAS MAY
HARM HEALTH OR KILL.
• Shut off shielding gas supply when not
in use.
• See American National Standard Z-49.1, "Safety
in Welding and Cutting Published by the
American Welding Society.
------------------------------------------------------------------------
Maximum inlet pressure is 100 psi. (6.9 bar.)
Install the shielding gas supply as follows:
1. Secure the cylinder to prevent it from falling.
2. Remove the cylinder cap. Inspect the cylinder valves
and regulator for damaged threads, dirt, dust, oil or
grease. Remove dust and dirt with a clean cloth. DO
NOT ATTACH THE REGULATOR IF OIL, GREASE
OR DAMAGE IS PRESENT! Inform your gas supplier
of this condition. Oil or grease in the presence of high
pressure oxygen is explosive.
3. Stand to one side away from the outlet and open the
cylinder valve for an instant. This blows away any dust
or dirt which may have accumulated in the valve out-
let.
4. Attach the flow regulator to the cylinder valve and
tighten the union nut(s) securely with a wrench. Note:
if connecting to 100% CO
2
cylinder, insert regulator
adapter between regulator and cylinder valve. If
adapter is equipped with a plastic washer, be sure it is
seated for connection to the CO
2
cylinder.
WARNING
5. Attach one end of the inlet hose to the outlet fitting of
the flow regulator. Attach the other end to the welding
system shielding gas inlet. Tighten the union nuts with
a wrench.
6. Before opening the cylinder valve, turn the regulator
adjusting knob counterclockwise until the adjusting
spring pressure is released.
7. Standing to one side, open the cylinder valve slowly a
fraction of a turn. When the cylinder pressure gage
stops moving, open the valve fully.
8. The flow regulator is adjustable. Adjust it to the flow
rate recommended for the procedure and process
being used before making a weld.
A-6
INSTALLATION
AutoDrive 4R90
A-6
WIRE DRIVE CONFIGURATION
(See Figure A.2)
CHANGING THE GUN RECEIVER
BUSHING
ELECTRIC SHOCK can kill.
• Turn the input power OFF at the
welding power source before instal-
lation or changing drive rolls and/or
guides.
• Do not touch electrically live parts.
• When inching with the gun trigger, electrode
and drive mechanism are "hot" to work and
ground and could remain energized several sec-
onds after the gun trigger is released.
• Do not operate with covers, panels or guards
removed or open.
• Only qualified personnel should perform mainte-
nance work.
------------------------------------------------------------------------
Tools required:
• 1/4" hex key wrench.
Note: Some gun bushings do not require the use of
the thumb screw.
1. Turn power off at the welding power source.
2. Remove the welding wire from the wire drive.
3. Remove the thumb screw from the wire drive.
4. Remove the welding gun from the wire drive.
5. Loosen the socket head cap screw that holds the
connector bar against the gun bushing.
Important: Do not attempt to completely
remove the socket head cap screw.
6. Remove the outer wire guide, and push the gun
bushing out of the wire drive. Because of the pre-
cision fit, light tapping may be required to remove
the gun bushing.
7. Disconnect the shielding gas hose from the gun
bushing, if required.
8. Connect the shielding gas hose to the new gun
bushing, if required.
9. Rotate the gun bushing until the thumb screw hole
aligns with the thumb screw hole in the feed plate.
Slide the gun receiver bushing into the wire drive
and verify the thumb screw holes are aligned.
10. Tighten the socket head cap screw.
11. Insert the welding gun into the gun bushing and
tighten the thumb screw.
GUN RECEIVER BUSHING
THUMB SCREW
SOCKET HEAD
CAP SCREW
CONNECTOR BLOCK
TIGHTENLOOSEN
WARNING
FIGURE A.2
A-7
INSTALLATION
AutoDrive 4R90
A-7
PROCEDURE TO INSTALL DRIVE ROLLS
AND WIRE GUIDES
ELECTRIC SHOCK can kill.
• Turn the input power OFF at the weld-
ing power source before installation
or changing drive rolls and/or guides.
• Do not touch electrically live parts.
• When inching with the gun trigger, electrode
and drive mechanism are "hot" to work and
ground and could remain energized several sec-
onds after the gun trigger is released.
• Do not operate with covers, panels or guards
removed or open.
• Only qualified personnel should perform mainte-
nance work.
------------------------------------------------------------------------
To remove drive rolls and wire guides:
1. Turn power off at the welding power source.
2. Remove the outer wire guide.
3. Rotate all of the triangular rings to the unlocked
position.
WARNING
4. Open the idle arms.
5. Remove the drive rolls and inner wire guide.
To install drive rolls and wire guides:
1. Turn off power at the welding power source.
2. Open the idle arms.
3. Assemble the inner wire guide.
4. Slide the drive rolls onto the drive hubs.
5. Close the idle arms.
6. Rotate all of the triangular rings to the locked posi-
tion.
7. Assemble the outer wire guide.
8. Adjust the pressure arms to the recommended
setting.
INNER WIRE GUIDE
IDLER ARM OPENED
OUTER WIRE GUIDE
A-8
INSTALLATION
AutoDrive 4R90
A-8
CONDUIT INSTALLATION
The K1546-xx series of conduits are compatible with
K515-xx, K565-xx, Wire Wizard and Electron Beam
Technologies conduits.
To install conduit to the wire drive:
1. Slide the conduit bushing into the feed plate and
secure with the set screw.
2. Slide the conduit into the bushing and lock in
place with the thumb screw.
CONDUIT
CONDUIT
BUSHING
THUMB
SCREW
SET
SCREW
A-9
INSTALLATION
AutoDrive 4R90
A-9
SYSTEM SET-UP
NEW ARMS
ArcLink XT
Connection
ArcLink
(5 Pin)
Work
Sense
Wire Feeder
(14 Pin)
Robotic
Torch
Power Wave i400
K2669-1
Work Piece
FANUC R-J30iA Controller
with Integrated Op Box
Optional Work
Sense Lead (21)
K1785-XX Wire Feeder
K884-5,-6
Control Cable
* Work
Cable (-)
Internal ArcLink XT
Communication
* Electrode
Cable (+)
SYSTEM SET-UP (SINGLE NEW ARMS)
Wire Feeder
(14 Pin)
Gas
Air
Auto Drive 4R90
* Refer to "Output Cable Guidelines" for recommended cable size
Electrode
Connection
B-1
OPERATION
AutoDrive 4R90
B-1
• ELECTRIC SHOCK CAN KILL.
Unless using COLD FEED fea-
ture, when feeding with gun trig-
ger, the electrode and drive
mechanism are always electri-
cally energized and could
remain energized several sec-
onds after the welding ceases..
• Do not touch electrically live part or electrode
with skin or wet clothing.
• Insulate yourself from work and ground.
• Always wear dry insulating gloves.
• Do not operate with covers, panels or guards
removed or open.
---------------------------------------------------------------------
• FUMES AND GASSES can be
dangerous.
• Keep your head out of fumes.
• Use ventilation or exhaust to
remove fumes from breathing
zone.
---------------------------------------------------------------------
• WELDING SPARKS can cause
fire or explosion.
• Keep flammable material away.
----------------------------------------------------------------------
ARC RAYS can burn.
• Wear eye, ear and body protec-
tion.
---------------------------------------------------------------------
SEE ADDITIONAL WARNING INFORMATION
UNDER ARC WELDING SAFETY PRECAUTIONS
AND IN THE FRONT OF THIS OPERATING MAN-
UAL.
----------------------------------------------------------------------
WARNING
SAFETY PRECAUTIONS
READ AND UNDERSTAND ENTIRE SECTION
BEFORE OPERATING MACHINE.
WIRE FEEDER
POSITIVE OUTPUT
NEGATIVE OUTPUT
INPUT POWER
DIRECT CURRENT
OPEN CIRCUIT
VOLTAGE
INPUT VOLTAGE
OUTPUT VOLTAGE
INPUT CURRENT
OUTPUT CURRENT
PROTECTIVE
GROUND
WARNING OR
CAUTION
U
0
U
1
U
2
I
1
I
2
GRAPHIC SYMBOLS THAT APPEAR ON
THIS MACHINE OR IN THIS MANUAL
B-2
OPERATION
B-2
AutoDrive 4R90
DEFINITION OF WELDING TERMS
GMAW
• Gas Metal Arc welding
FCAW
Flux Core Arc Welding
STT™
• Surface Tension Transfer
PRODUCT DESCRIPTION
General Physical Description
The AutoDrive 4R90 wire feeders are powerful yet
compact wire drives for robotic and hard automation
applications.
The MAXTRAC 4 roll wire drive gives steady feeding
of all wire sizes and types. The drive features split
wire guides, tool-less drive roll changing, dual spring
pressure arms and changeable gun bushings all
mounted in a precision die cast aluminum frame. A
right angle gear box efficiently transfers motor power
for both high torque and high speed.
The AutoDrive 4R90 is optimized for the FANUC
AM100iC arm. The small, light weight package maxi-
mizes arm speed and working envelope. Quick
release mounting makes for fast servicing of the feed-
er and torch.
General Functional Description
A high resolution tachometer lets the AutoDrive 4R90
accurately feed wire at slow speeds and have good
dynamic response.
RECOMMENDED PROCESSES
• GMAW
• FCAW
• STT™
PROCESS LIMITATIONS
K2685-2 AutoDrive 4R90:
ß • Maximum wire size = .045 (1.2mm)
EQUIPMENT LIMITATIONS
K2685-2 AutoDrive 4R90:
ß • Maximum GMAW gun length = 10’ (3.1m)
ß • Maximum FCAW gun length = 10’ (3.1m)
ß • Maximum wire drive control cable length = 100ft
(31m)
ß • Robot and power source software may need to be
updated.
ß • Drive rolls are not included with the feeder.
ß • Mounts only to FANUC ArcMate100iC arms.
RECOMMENDED POWER SOURCES
ß • Power Wave 355M (requires wire drive board)
ß • Power Wave F355i
ß • Power Wave 455 (all models)
ß • Power Wave 455/STT M
ß • Power Wave 655/ R
C-1
ACCESSORIES
C-1
AutoDrive 4R90
WIRE TYPE
Steel Wires:
Cored Wires:
Aluminum Wires:
KITS ELECTRODE SIZE
KP1505-030S .023-.030 (0.6-0.8mm)
KP1505-035S .035 (0.9mm)
KP1505-040S .040 (1.0mm)
KP1505-045S .045 (1.2mm)
KP1505-035C .030-.035" (0.8-0.9mm)
KP1505-045C .040-.045" (1.0-1.2mm)
KP1507-3/64A 3/64" (1.2mm)
OPTIONAL KITS AND ACCESSORIES
Includes: 4 V groove
drive rolls and inner
wire guide.
Includes: 4 Knurled
drive rolls and inner
wire guide.
Includes: 4 polished
U groove drive rolls,
outer wire guide and
inner wire guide.
DRIVE ROLL KITS 4 ROLL DRIVE
C-2
ACCESSORIES
C-2
AutoDrive 4R90
K1500-4
K1500-5
K489-7
K515-xx
K565-xx
K1546-1
Gun Receiver Bushing (for gun
with K466-3 Lincoln gun connec-
tors; compatible with Miller® guns.)
Gun Receiver Bushing (compatible
with Oxo® guns.)
Gun Receiver Bushing (for Lincoln
Fast-Mate guns.)
Wire Conduit
Wire Conduit
Incoming Bushing, for Lincoln
Conduit .025- 1/16" (0.6 - 1.6mm)
wire. Compatible with Electron
Beam Conduit.
Includes: Gun receiver bush-
ing with hose nipple, set screw
and hex key wrench.
Includes: Gun receiver bushing
with hose nipple, 4 guide tubes,
set screw and hex key wrench.
Includes: Gun receiver bushing
with trigger connector.
Requires K1546-1
Requires K1546-1
Includes: Incoming bushing and
hex key wrench.
K1500-1
K1500-2
K1500-3
Gun Receiver Bushing (for guns
with K466-1 Lincoln gun connec-
tors; Innershield and Subarc guns)
Gun Receiver Bushing (for guns
with K466-2, K466-10 Lincoln gun
connectors; Magnum 200/300/400
guns and compatible with Tweco®
#2-#4)
Gun Receiver Bushing (for guns
with K613-7 Lincoln gun connec-
tors; Magnum 550 guns and com-
patible with Tweco® #5)
Includes: Gun receiver bush-
ing, set screw and hex key
wrench.
Includes: Gun receiver bush-
ing with hose nipple, set screw
and hex key wrench.
Includes: Gun receiver bush-
ing with hose nipple, set screw
and hex key wrench.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33

Lincoln Electric AutoDrive 4R90 Manuel utilisateur

Catégorie
Système de soudage
Taper
Manuel utilisateur

dans d''autres langues