Q-tran QOM-eLED+DALI-DT8 LED Power Supply Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

INSTALLATION LED POWER SUPPLY - QOM-eLED+DALI-DT8
© 2021 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-15-22
LOW VOLTAGE LIGHTING SYSTEM
CLASS: 3425-15
3425-95
COMPLIANT
Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
This power supply must be installed according to the National Electric
Code and local codes and ordinances.
This power supply is to be installed and serviced only by an licensed
electricians.
This power supply is to be installed so that it is not likely to be contacted
by people.
To avoid a hazard to children, account for all parts and destroy all
packaging materials.
Do not install in wet locations.
Must be installed by licensed electrician.
INSTALLATION LED POWER SUPPLY - QOM-eLED+DALI-DT8
© 2021 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-15-22
Mounting Options
Housing
BOTTOM VIEW
ISOMETRIC VIEW
1.36" KNOCKOUT 4X
(FOR 1" FITTINGS)
1.07" KNOCKOUT 5X
(FOR 3/4" FITTINGS)
4.90"
14.5"
15.4"
9.22" 4.90"
NOTE: To order additional lengths of wire for connection in the secondary
Please call factory for availability.
: QOM must be installed as shown.
Pole Mount
Surface Wall Mount
2.00"
0.25"
1/4”x2” wood screw or
LAG bolt recommened
1.82" 3.38"
3.14"
INSTALLATION LED POWER SUPPLY - QOM-eLED+DALI-DT8
© 2021 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-15-22
WARNING: Risk of electrical shock. May result in serious injury or death. Disconnect power before servicing or installing.
CAUTION: The device may only be connected and installed by a qualified electrician. All applicable regulations, legislation and building codes
must be observed. Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs.
V-
V-
V+
V+
+
R-
G-
B-
W-
D1+
D2+
D1-
D2-
LED groups 12-36VDC IN
D2-
D1-
D2+
D1+
V+
V+
V-
V+
V-
B-
R-
G-
W-
LED groups 12-36VDC IN
DALI Signal
in/out
V-
V-
V+
V+
+
R-
G-
B-
W-
D1+
D2+
D1-
D2-
LED groups 12-36VDC IN
DALI Signal
in/out
DALI Signal
in/out
DALI
Controller
D1+
D2+
D1-
D2-
DALI
IN
DALI
OUT
V-
V-
V+
V+
+
R-
G-
B-
W-
12-36VDC INLED groups
LED
D1+
D2+
D1-
D2-
DALI Signal
in/out
V-
V-
V+
V+
+
R-
G-
B-
W-
12-36VDC INLED groups
LED
D1+
D2+
D1-
D2-
DALI Signal
in/out
V-
V-
V+
V+
+
R-
G-
B-
W-
12-36VDC INLED groups
LED
D1+
D2+
D1-
D2-
DALI Signal
in/out
Primary Wiring
Control Wiring: DALI Connections
Secondary Wiring
NEU
GND
HOT
LED DRIVER
(120-277V)
3-Wire default 4-Wire default 5-Wire default
To DALI Controller
V-
V-
V+
V+
+
R-
G-
B-
W-
D1+
D2+
D1-
D2-
D1+
D2+
D1-
D2-
{
12-36VDC IN
12-36VDC INLED groups
-+2
10.2-1.5 mm2
0.35 inch
0.5-1.5 mm2
AWG 20-16
0.35 inch
AWG 24-16
VDC and LED connectors: Other connectors:
DALI Signal
in/out
LED
V-
V-
V+
V+
+
R-
G-
B-
W-
D1+
D2+
D1-
D2-
LED groups 12-36VDC IN
V-
V-
V+
V+
+
R-
G-
B-
W-
D1+
D2+
D1-
D2-
LED groups 12-36VDC IN
DALI Signal
in/out
V-
V-
V+
V+
+
R-
G-
B-
W-
D1+
D2+
D1-
D2-
LED groups 12-36VDC IN
DALI Signal
in/out
DALI Signal
in/out
DALI
Controller
*By Others
DALI Bus
Power Supply
*By Others
*By others.
V-
V-
V+
V+
D1+
D2+
D1-
D2-
DALI Signal
in/out
12-36VDC IN
+
R-
G-
B-
W-
LED groups
DALI
OUT
DALI
IN
DALI
Controller
*By Others
DALI Bus
Power Supply
*By Others
Warm
Cool
+24V
+24V W C
D1+
D2+
D1-
D2-
V-
V-
V+
V+
DALI Signal
in/out
12-36VDC IN
+
R-
G-
B-
W-
LED groups
DALI
OUT
DALI
IN
DALI
Controller
*By Others
DALI Bus
Power Supply
*By Others
R G B+24
+24V
Red
Green
Blue
D1+
D2+
D1-
D2-
V-
V-
V+
V+
DALI Signal
in/out
12-36VDC IN
+
R-
G-
B-
W-
LED groups
DALI
OUT
DALI
IN
DALI
Controller
*By Others
DALI Bus
Power Supply
*By Others
R G B W+24
+24V
White
Red
Green
Blue
5-Wire4-Wire3-Wire
Connecting and Configuring the DALI-DT8 Decoder
NOTE:
For customization or pre-programming
contact a local sales rep.
DALI commissioning to be performed by a
third party at time of installation.
INSTALLATION LED POWER SUPPLY - QOM-eLED+DALI-DT8
© 2021 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-15-22
Manual Configuration
Other Features
0-6 0-9
1 2
Manual set button
Digital display
1. Set address manually:
(tens) (ones)
00~63
1 2
Press and hold either button
Use the buttons to set address
1 2
Set Address
(5 sec)
1. Locking the configuration:
Confirm
1 2
Press and hold either button
(5 sec)
DT8 Dimming Feature:
NOTE: DT8 color type of the dimmer can be TW, RGB, or RGBW.
2. Reset to factory defaults:
Reset
1 2
1 2
Set Address
Press and hold either button
(5 sec)
Use the buttons to set address
TW
RGB
1 2
Press and hold both button
Use the second button to
set the output type
(5 sec)
INSTALLATION LED POWER SUPPLY - QOM-eLED+DALI-DT8
© 2021 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-15-22
Wiring Installation
C
LED DRIVER 2
(120 - 277V)
B
LED DRIVER 2
(120 - 277V)
LED DRIVER 2
B
V-
V-
V+
V+
+
R-
G-
B-
W-
D1+
D2+
D1-
D2-
LED groups
DALI Signal
in/out
12-36VDC IN
V-
V-
V+
V+
+
R-
G-
B-
W-
D1+
D2+
D1-
D2-
LED groups
DALI Signal
in/out
12-36VDC IN
V-
V-
V+
V+
+
R-
G-
B-
W-
D1+
D2+
D1-
D2-
LED groups
DALI Signal
in/out
12-36VDC IN
NEU
GND
HOT
DALI
IN
DALI
OUT
SECONDARY
PRIMARY
DA -
DA +
LEAD WIRE
Black = +24V
White = White
Red = Red
Green = Green
Blue = Blue
NEU
GND
HOT
DALI
Controller
*By others.
To next
power supply
R G B W +24 R G B W +24 R G B W +24
LEDLEDLED
DALI Bus
Power Supply
*By others.
DA +
DA -
Red
Blue
NEU
GND
HOT
LED DRIVER
(120-277V)
D1+ D1- D2+ D2-
DALI IN DALI OUT
V-
V-
V+
V+
+
R-
G-
B-
W-
12-36VDC INLED groups
LED
D1+
D2+
D1-
D2-
DALI Signal
in/out
INSTALLATION LED POWER SUPPLY - QOM-eLED+DALI-DT8
© 2021 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-15-22
CSA Requirements
Suitable for indoor use
This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with
applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.
To avoid a hazard to children, account for all parts and destroy all packaging materials.
Model Input Voltage
(V)
Frequency Nominal Output
Voltage (VDC)
Nominal Output
Wattage (W)
Input Current
(A)
QOM-eLED-100+DALI
QOM-eLED-200+DALI
QOM-eLED-300+DALI
120
120
120
0.95
1.90
2.85
50/60
50/60
50/60
24
24
24
100
200
300
QOM-eLED+DALI
120V
INPUT VOLTAGE OUTPUT VOLTAGE
24V
CONTROL TYPE
DT8
DT624V
WARNING:
RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH
A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED.
CONSULT A QUALIFIED ELECTRICIAN
RISQUE D'INCENDIE. SI L'INSTALLATION IMPLIQUE UN FIL DE COURANT À
TRAVERS UNE STRUCTURE DE BÂTIMENT, DES MÉTHODES DE CÂBLAGE
SPÉCIALES SONT NÉCESSAIRES. CONSULTEZ UN ÉLECTRICIEN QUALIFIÉ
This product must be installed in accordance with the applicable installation
code by a person familiar with the construction and
operation of the product and the hazards involved.
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION
PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET
SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS.
Q-TRAN, INC.
MILFORD, CT U.S.A.
(203) 367-8777
WWW.Q-TRAN.COM
Suitable for indoor or outdoor use
Convient pour une utilisation intérieure ou extérieure
Wall mount only
Installation murale seulement
Suitable for mounting within 1.2m (4ft) of the ground
Peut être installé à moins de 1.2 m (4 pi) du sol
Suitable for use with submersible luminaires or submersible pumps
Convient pour une utilisation avec des luminaires submersibles ou
des pompes submersibles
Suitable for wet locations
Convient aux emplacements mouillé
CAUTION: This control unit has more than one power supply point
disconnect all power supplies before servicing
ATTENTION: Cette unité de contrôle a plus d'un point d'alimentation
débranchez toutes les alimentations avant l'entretien
For supply connections use wire rated for at least 60°C.
Pour les connexions d'alimentation, utilisez un fil évalué au moins À 60°c.
Keep Enclosure Cover Closed
Gardez le couvercle du boîtier fermé
Read Installation Instructions Before Wiring
Lire les instructions d'installation avant le câblage
Do not connect two or more power supplies in parallel
Ne connectez pas deux alimentations ou plus en parallèle
Class 2
Classe 2
LOW VOLTAGE LIGHTING SYSTEM
CLASS: 3425 - 15 3425 - 95
LED LANDSCAPE LIGHTING SYSTEM
CLASS: 3402 - 15 3402 - 95
Model Input Voltage
(V)
Frequency Nominal Output
Voltage (VDC)
Nominal Output
Wattage (W)
Input Current
(A)
QOM-eLED-100+DALI
QOM-eLED-200+DALI
QOM-eLED-300+DALI
120 / 277
120 / 277
120 / 277
0.95 / 0.40
1.90 / 0.80
2.85 / 1.20
50/60
50/60
50/60
24
24
24
100
200
300
QOM-eLED+DALI
120V-277V
INPUT VOLTAGE OUTPUT VOLTAGE
CONTROL TYPE
DT8
DT6
24V
WARNING:
RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH
A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED.
CONSULT A QUALIFIED ELECTRICIAN
This product must be installed in accordance with the applicable installation
code by a person familiar with the construction and
operation of the product and the hazards involved.
Q-TRAN, INC.
MILFORD, CT U.S.A.
(203) 367-8777
WWW.Q-TRAN.COM
Suitable for indoor or outdoor use
Wall mount only
Suitable for mounting within 1.2m (4ft) of the ground
Suitable for use with submersible luminaires or submersible pumps
Suitable for wet locations
CAUTION: This control unit has more than one power supply point
disconnect all power supplies before servicing
For supply connections use wire rated for at least 60°C.
Keep Enclosure Cover Closed
Read Installation Instructions Before Wiring
Class 2
LOW VOLTAGE LIGHTING SYSTEM
CLASS: 3425 - 95
LED LANDSCAPE LIGHTING SYSTEM
CLASS: 3402 - 95
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Q-tran QOM-eLED+DALI-DT8 LED Power Supply Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à