BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power off before inspection, installation or removal.
Properly ground electrical enclosure.
RISK OF FIRE
Follow all NEC and local codes.
Use only UL approved wire for input/output connections. Minimum
size 18 AWG or 14 AWG for continuous runs.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation avant d’inspecter, installer ou déplacer le luminaire.
Assurez-vous de correctement mettre à la terre le boîtier d’alimentation
électrique.
RISK OF FIRE
Respectez tous les codes NEC et codes locaux.
N’utilisez que des ls approuvés par UL pour les entrées/sorties de
connexion. Taille minimum 18 AWG ou 14 AWG pour les rangées continues.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 120 or 277V, 50/60 Hz and connected to an
individual properly grounded branch circuit, protected by a 20 ampere circuit breaker.
Use min. 75°C supply conductor.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance with
National Electric Code (NEC) Article 600 and local codes.
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications
subject to change without notice. All values are design or typical values when measured under
laboratory conditions.
Page 2 of 3
(Rev 4/19/23)
IND379-Lumination-Montage-Series-Trimless-Installation-Guide_R01
Lumination® Montage Installation Guide
Carefully remove the LMM xture out of the
packaging. The xture can be attached to the
rough in kit by attaching one spring to the
rough in kit and letting the xture hang to
make electrical connections.
1
Unit Installation
Tile Ceiling (above ceiling access after installation)
Be sure that the appropriate Rough in Kit is installed into the ceiling before starting these instructions.
Connect the quick connect from the Rough in Kit to the quick
connect on the luminaire. Assemble connector housing.
2
Connect two
quick connects
Assembled connector
housing
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications
subject to change without notice. All values are design or typical values when measured under
laboratory conditions.
Page 3 of 3
(Rev 4/19/23)
IND379-Lumination-Montage-Series-Trimless-Installation-Guide_R01
Risk of damage: Make sure that dimming cables are connected to proper driver inputs. Wrong connection may cause damage to the product.
Must use UL approved conduit ttings for all enclosure box connections to prevent wire cuts by sharp edges and excessive strain on wiring.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A]
RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [A] est conforme á laNMB-003 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
Fixture intended for commercial use only. Use only in non-insulated applications.
Wiring Instructions
If using a dimming controller, connect matching-colored wires together (violet and gray leads). Fixture cover must be removed to access
the dimming leads.
Carefully tuck the electrical conduit into the ceiling. Compress the torsion
springs on the side of the xture and insert them into the brackets on the rough
in kit. Ensure that springs are properly inserted into the mounting brackets.
Push the xture up until it is ush with the ceiling.
3
Finish the ceiling, taping, and
mudding around the xture
to the lip for a clean, nished
edge.