Leonton PG2-1002-SFP Manuel utilisateur

Catégorie
Commutateurs réseau
Taper
Manuel utilisateur

Ce manuel convient également à

PG2-1002-SFP-24
PG2-1002-SFP-24-T
© Copyright 2022 Leonton Technologies Co., Ltd. All Rights Reserved
This document contains information, which is protected by copyright. Reproduction, adaptation or
translation without prior permission is prohibited, except as allowed under the copyright laws.
Disclaimer
Leonton Technologies, Co. Ltd. provides this manual without warranty of any kind, expressed or implied,
including but not limited to the implied warranties of merchantability and fitness for a particular purpose.
Leonton Technologies, Co. Ltd. may make improvements and/or changes to the product and/or
specifications of the product described in this manual, without prior notice. Leonton Technologies, Co. Ltd.
will not be liable for any technical inaccuracies or typographical errors found in this guide. Changes are
periodically made to the information contained herein and will be incorporated into later versions of the
manual. The information contained is subject to change without prior notice.
C1D2 Installation and Operating Instructions
These devices are open-type devices that are to be installed in an enclosure only accessible with the use of
a tool, suitable for the environment.
“This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations
only.”
Caution: EXPLOSION HAZARD - Do not disconnect equipment unless power has been removed or the area
is known to be non-hazardous.
Caution: EXPLOSION HAZARD - Substitution of any components may impair suitability for Class I, Division
2.
Instructions d'installation et d'utilisation du C1D2
Ces appareils sont des appareils de type ouvert qui doivent être installés dans un boîtier accessible
uniquement à l'aide d'un outil adapté à l'environnement.
«Cet équipement est conçu pour être utilisé uniquement dans les zones de classe I, division 2, groupes A,
B, C et D ou non dangereuses.»
Attention: RISQUE D'EXPLOSION - Ne débranchez pas l'équipement à moins que l'alimentation ait é
coupée ou que la zone ne soit pas dangereuse.
Attention: RISQUE D'EXPLOSION - La substitution de tout composant peut nuire à la compatibilité avec la
classe I, division 2.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant
to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy. It may cause harmful interference to radio communications if the equipment is not installed and
used in accordance with the instructions. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by the grantee of this device could void
the user's authority to operate the equipment.
Déclaration FCC
Cet équipement a été testé et reconnu conforme aux limites de la classe A pour les équipements
numériques, conformément à la section 15 des Réglementations FCC. Ces limites sont conçues pour fournir
une protection raisonnable contre toutes interférences nuisibles dans un milieu résidentiel. Cet
équipement génère, utilise, et peut émettre de l’énergie de fréquence radio et, s’il n’est pas installé et
utilisé conformément au manuel d’instruction, peut perturber la réception radio. Cependant, il n’est pas
garanti que l’équipement ne produira aucune interférence dans une installation particulière. Si cet
équipement cause des interférences nuisibles à la réception radio ou télévisée, qui peuvent être
déterminées en l’éteignant et le rallumant, l’utilisateur est encouragé à essayer de remédier au problème
en prenant les mesures suivantes:
Réorienter ou déplacer l’antenne réceptrice.
Augmenter la distance entre l’équipement et le récepteur.
Connecter l’équipement à une prise secteur sur un circuit différent de celui utilisé par le récepteur.
Consulter le négociant ou un technicien radio/TV expérimenté.
Attention: Tout changement ou modification non expressément approuvé par le concessionnaire de cet
appareil pourrait annuler l'autorité de l'utilisateur à utiliser l'équipement.
CE Mark Warning
This is a Class-A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
CE Mark Avertissement
Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut être utilisé en
présence d'interférences radio.
This document is the current official release manual. Please check our website (www.leonton.com) for
any updated manual or contact us by e-mail (sales@leonton.com).
CONTENT
OVERVIEW ................................................................................................................................... 1
Key Features ................................................................................................................................................................. 1
Package Contents ....................................................................................................................................................... 2
Safety Precaution ........................................................................................................................................................ 2
HARDWARE DESCRIPTION ...................................................................................................... 3
Physical Dimensions .................................................................................................................................................. 3
Front Panel .................................................................................................................................................................... 4
Top View ........................................................................................................................................................................ 4
LED Indicators .............................................................................................................................................................. 5
Ethernet Ports .............................................................................................................................................................. 6
Cabling ........................................................................................................................................................................... 7
Wiring the Power Inputs ........................................................................................................................................... 9
Wiring the Fault Alarm Contact ............................................................................................................................ 10
Grounding Note ........................................................................................................................................................ 10
MOUNTING INSTALLATION .................................................................................................. 11
DIN-Rail Mounting ................................................................................................................................................... 11
Wall Mounting ........................................................................................................................................................... 13
HARDWARE INSTALLATION .................................................................................................. 14
Installation Steps ...................................................................................................................................................... 14
TROUBLE SHOOTING .............................................................................................................. 16
1
OVERVIEW
This series is rated IP30 and installation by DIN Rail. Each unit of this industrial PoE+ gigabit unmanaged
Ethernet switch series has 8*10/100/1000Tx with IEEE 802.3at compliant ports (30W/port) and 2 dual rate
(100/1000) SFP slots, suitable for applications that require high bandwidth and long distance
communication.
In order to prevent unregulated voltage, this series provides high EFT and ESD protection. This also allows
it to function in harsh environments, as well as support power redundancy with a dual power input design
with reverse polarity protection. The built-in relay warning function alerts users about occurring power
failures.
With one model having an operating temperature of -10°C ~ 65°C, and another with a wide operating
temperature of -40°C ~ 75°C, this series is designed to meet any needs for industrial automation application
and harsh environments.
Key Features
Interface & Performance
Copper port support auto MDI/MDI-X function
Embedded 8*10/100/1000Tx (PSE 30W/Port) and 2*100/1000 SFP Slots
Store-and-forward switching architecture
8K MAC Address Table
Supports 9.6Kbytes Jumbo Frame
4Mbits memory buffer
Power Input
Redundant power DC 12-55V with connective 1*6-pin removable terminal block, with SELV output
certified by UL61010-2-201
1 removable 6-contact terminal block
Max. current 6A
Max. PoE output: 60Watts@12VDC, 200Watts@36-55VDC
Certification
CE/FCC
UL 61010-1
UL 61010-2-201
ISA 12.12.01
Operating Temperature
Standard operating temperature model: -10°C ~ 65°C
Extended operating temperature model (-T): -40°C ~ 75°C
Case/Installation
IP30 protection (not certified by UL)
DIN-Rail and wall mount design
Installation in a pollution degree 2 industrial environment
2
Package Contents
1 - PG2-1002-SFP-24(-T) - Unit weight: 0.856kg ( 1.89lb), Shipping weight: 1.04kg ( 2.29lb)
2 - Wall mounting brackets and screws
1 - Quick installation guide
Safety Precaution
Attention
If the DC voltage is supplied by an external circuit, please use a protection device on the power supply
input. Supply by UL Listed industrial use power. The industrial Ethernet switch’s hardware specs, ports,
cabling information, and wiring installation will be described within this user manual.
Attention
Si la tension CC est fournie par un circuit externe, veuillez utiliser un dispositif de protection sur l'entrée
d'alimentation. Fourniture par courant industriel homologué UL. Les spécifications matérielles, les ports,
les informations de câblage et l'installation du câblage du convertisseur de média industriel seront décrits
dans ce manuel d'utilisation.
Warning Labels
The caution label means that you should check the certain information on user manual when working with
the device. (Shown in Figure 1.1)
Étiquettes d'avertissement
L'étiquette d'avertissement signifie que vous devez vérifier certaines informations sur le manuel
d'utilisation lorsque vous travaillez avec l'appareil. (Montré dans la Figure 1.2)
Figure 1.1 - Caution Label
Figure 1.1 - Étiquette de mise en garde
Figure 1.2 - Hot Surface Warning Label
Figure 1.2 - Étiquette d'avertissement de surface chaude
3
HARDWARE DESCRIPTION
Physical Dimensions
Figure 2.1, below, shows the physical dimensions of PG2-1002-SFP-24 series.
(W x H x D) is 46mm x 142mm x 99mm
Figure 2.1: Physical Dimensions
4
Front Panel
The front panel of the PG2-1002-SFP-24 series industrial PoE+ gigabit Unmanaged Ethernet Switch is
shown below in Figure 2.2.
Figure 2.2: The Front Panel
Top View
Figure 2.3, below, shows the top panel of the PG2-1002-SFP-24 series switches that is equipped with one
6-pin removal terminal block connector for dual DC power inputs (12-55VDC).
Figure 2.3: Top Panel View
LED Indicator
10/100Mbps Link/Act LED
1000Mbps Link/Act LED
100/1000Mbps SFP Link/Act LED
10/100/1000Base-T(X) PoE+ Copper Port
PoE Link/Act LED
5
LED Indicators
There are LED light indicators located on the front panel of the industrial switch that display the power
status and network status. Each LED indicator has a different color and has its own specific meaning, see
below in Table 2.1.
Table 2.1: LED Indicators
LED
Color
Description
P1
Green
On
Power input 1 is active
Off
Power input 1 is inactive
P2
Green
On
Power input 2 is active
Off
Power input 2 is inactive
Fault
Red
On
Power input 1 or 2 is inactive
Off
Power input 1 and 2 are both functional
SFP Port
Link/Act
Green
On
Connected to network, 1000Mbps
Flashing
Networking is active
Off
Not connected to network
Amber
On
Connected to network, 100Mbps
Flashing
Networking is active
Off
Not connected to network
LAN Port
Link/Act
Green
On
Connected to network, 1000Mbps
Flashing
Networking is active
Off
Not connected to network
Green
On
Connected to network, 10/100Mbps
Flashing
Networking is active
Off
Not connected to network
PoE
Green
On
The port is supplying power to the powered-device
Off
No powered-device attached or power supplying fails
6
Ethernet Ports
RJ-45 Ports (Auto MDI/MDIX)
The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX or 1000Base-T
devices connections. Auto MDI/MDIX means that the switch can connect to
another switch or workstation without changing the straight-through or
crossover cabling. See the figures as below for straight-through and crossover
cabling schematics.
10/100BASE-T(X) RJ-45 Pin Assignments (Table 2.2)
Crossover Cable
Straight Through Cable
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
1 / RX+
3 / TX+
1 / RX+
1 / TX+
2 / RX-
6 / TX-
2 / RX-
2 / TX-
3 / TX+
1 / RX+
3 / TX+
3 / RX+
6 / TX-
2 / RX-
6 / TX-
6 / RX-
Table 2.2
1000BASE-T RJ-45 Pin Assignments (Table 2.3)
Crossover Cable
Straight Through Cable
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
1 / TP0+
3 / TP1+
1 / TP0+
1 / TP1+
2 / TP0-
6 / TP1-
2 / TP0-
2 / TP1-
3 / TP1+
1 / TP0+
3 / TP1+
3 / TP0+
4 / TP2+
7 / TP3+
4 / TP2+
4 / TP3+
5 / TP2-
8 / TP3-
5 / TP2-
5 / TP3-
6 / TP1-
2 / TP0-
6 / TP1-
6 / TP0-
7 / TP3+
4 / TP2+
7 / TP3+
7 / TP2+
8 / TP3-
5 / TP2-
8 / TP3-
8 / TP2-
Table 2.3
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
7
Cabling
Use the four twisted-pair, category 5e, or the above cabling for RJ-45 port connections. The cable between
the Switch and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for
both telecommunication and data communication applications.
Caution: Please employ optional optical transceiver (SFP/Fixed Fiber) that complies with IEC 60825-
1 and classified as Class 1 laser product.
Attention: Veuillez utiliser un émetteur-récepteur optique (SFP) conforme à la norme CEI 60825-1
et classé comme produit laser de classe 1.
To connect the transceiver and LC cable, please follow below steps:
Step 1. Insert the SFP transceiver module into the SFP slot as shown below in Figure 2.4. Notice that the
triangle mark is at the bottom of the SFP slot. Figure 2.5 shows SFP transceiver module was inserted.
Figure 2.4: Transceiver to the SFP Module
Figure 2.5: Transceiver Inserted
8
Step 2. Insert the fiber cable of the LC connector into the transceiver as shown below in Figure 2.6.
Figure 2.6: LC Connector to the Transceiver
To remove the LC connector from the transceiver, please follow the steps shown below:
Step 1. Press the upper side of the LC connector from the transceiver and pull it out to release as shown
below in Figure 2.7
Figure 2.7: Remove LC Connector
Step 2. Push down the metal clasp and pull the transceiver out by the plastic part as shown below in Figure
2.8
Figure 2.8: Pull Out from the SFP Module
9
Wiring the Power Inputs
Caution: Please follow the below steps to insert the power wire.
Attention: Veuillez suivre les étapes ci-dessous pour insérer le câble d'alimentation.
Step 1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on
the terminal block connector as shown below in Figure 2.9.
Figure 2.9: Power Terminal Block
Step 2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.10.
Figure 2.10: Power Terminal Block
Caution: Only use copper conductors, 12C, tighten to 7 in-lbs (0.79 Nm). The
wire gauge for the terminal block should range between 18~20 AWG.
Attention: Utilisez uniquement des conducteurs en cuivre, 125 ° C, serrer à 7 in-
lbs (0,79 Nm). Le calibre des fils du bornier doit être compris entre 18 et 20 AWG.
10
Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of the terminal block connector as the picture shows below in 錯誤!
找不到參照來源。11. By inserting the wires, it will detect the fault status including power failure or port
link failure (managed industrial switch only) and form a normally open circuit. An application example for
the fault alarm contact is shown below in 錯誤! 找不到參照來源。11.
Figure 2.11: Wiring the Fault Alarm Contact
Caution: The wire gauge for the terminal block should range between 12 ~ 24 AWG.
If only using one power source, jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate
power fault alarm.
Attention: Le calibre des fils du bornier doit être compris entre 12 et 24 AWG.
Si vous n'utilisez qu'une seule source d'alimentation, jumelez les broches 1 à 5 et les
broches 2 à 6 pour éliminer l'alarme de panne de courant.
Grounding Note
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run
the ground connection from the ground screw to the grounding surface prior to connecting devices. The
grounding screw symbol is shown blow in Figure 2.12.
Figure 2.12: Grounding screw symbol
Caution: Using a shielded cable achieves better electromagnetic compatibility.
Attention: L'utilisation d'un câble blindé permet une meilleure compatibilité
électromagnétique.
11
MOUNTING INSTALLATION
DIN-Rail Mounting
The DIN-Rail is pre-installed on the industrial Ethernet Switch from the factory. If the DIN-Rail is not on the
industrial Ethernet Switch, please see Figure 3.1 to learn how to install the DIN-Rail on the Switch.
Figure 3.1: The Rear Side of the Switch and DIN-Rail Bracket
Follow the steps below to learn how to hang the industrial Switch.
Step 1. Use the screws to install the DIN-Rail bracket on the rear side of the industrial Switch.
Step 2. To remove the DIN-Rail bracket, do the opposite from Step 1.
Step 3. After the DIN-Rail bracket is installed on the rear side of the Switch, insert the top of the DIN-Rail
on to the track as shown below in Figure 3.2.
12
Figure 3.2: Insert the Switch on the DIN-Rail
Step 4. Lightly pull down the bracket on to the rail as shown below in Figure 3.3.
Figure 3.3: Stable the Switch on DIN-Rail
Step 5. Check if the bracket is mounted tightly on the rail.
Step 6. To remove the industrial Switch from the rail, do the opposite from the above steps.
13
Wall Mounting
Follow the steps below to mount the industrial Switch using the wall mounting bracket as shown below in
Figure 3.4.
Step 1. Remove the DIN-Rail bracket from the industrial Switch by loosening the screws.
Step 2. Place the wall mounting brackets on the top and bottom of the industrial Switch.
Step 3. Use the screws to screw the wall mounting bracket on the industrial Switch.
Step 4. Use the hook holes at the corners of the wall mounting bracket to hang the industrial Switch on
the wall.
Step 5. To remove the wall mount bracket, do the opposite from the steps above.
Figure 3.4: Remove DIN-Rail Bracket from the Switch and Install the Wall Mount Bracket
Below, in Figure 3.5 are the dimensions of the wall mounting bracket.
Figure 3.5: Wall Mounting Bracket Dimensions
14
HARDWARE INSTALLATION
Installation Steps
This section will explain how to install PG2-1002-SFP-24 series.
Installation Steps
Step 1. Unpack the industrial Switch from the original packing box.
Step 2. Check if the DIN-Rail bracket is screwed on the industrial Switch.
If the DIN-Rail is not screwed on the industrial Switch, please refer to the DIN-Rail Mounting section
for DIN-Rail installation.
If you want to wall mount the industrial Switch, please refer to the Wall Mounting section for wall
mounting installation.
Step 3. To hang the industrial Switch on a DIN-Rail or wall, please refer to the Mounting Installation section.
Step 4. Power on the industrial Switch and then the power LED light will turn on.
If you need help on how to wire power, please refer to the Wiring the Power Inputs section.
Please refer to the LED Indicators section for LED light indication.
Step 5. Prepare the twisted-pair, straight-through category 5 cable for Ethernet connection.
Step 6. Insert one side of the RJ-45 cable into Switch’s Ethernet port and on the other side into the
networking device’s Ethernet port, e.g. switch PC or server. The Ethernet port’s (RJ-45) LED on the
industrial Switch will turn on when the cable is connected to the networking device.
Please refer to the LED Indicators section for LED light indication.
Step 7. Insert one side of the SFP cable into Switch’s SFP port and on the other side into the networking
device’s SFP port, e.g. switch or server. The SFP port’s LED on the industrial Switch will turn on when
the cable is connected to the networking device.
Please refer to the LED Indicators section for LED light indication.
Step 8. When all connections are set and the LED lights all show normal, the installation is complete.
15
Caution: If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Attention: Si l'équipement est utilisé d'une manière non spécifiée par le fabricant, la
protection fournie par l'équipement peut être altérée.
Caution: The installation that the safety to any system incorporating the equipment is
the responsibility of the assembler of the system.
Attention: L'installation que la sécurité de tout système intégrant l'équipement est de la
responsabilité de l'assembleur du système.
Caution: This is an OPEN TYPE module and should be installed in a final safety enclosure
characteristic.
Attention: Il s'agit d'un module de TYPE OUVERT et doit être installé dans une
caractéristique finale d'enceinte de sécurité.
Caution: This device is intended for use indoor and at altitudes up to 2000 meters.
Attention: Cet appareil est destiné à être utilisé en intérieur et à des altitudes allant
jusqu'à 2000 mètres.
Caution: Ambient Relative Humidity should be within the range of 5 and 95% (non-
condensing).
Attention: L'humidité relative ambiante doit être comprise entre 5 et 95% (sans
condensation).
16
TROUBLE SHOOTING
Verify you have the right power cord or adapter. Never use a power supply or adapter with a non-
compliant DC output voltage or it will burn the equipment.
Select the proper UTP or STP cable in order to construct the network. Use an unshielded twisted-pair
(UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω Category 5e for
10M/100/1000Mbps. Also be sure that the length of any twisted-pair connection does not exceed 100
meters (328 feet).
Diagnosing LED Indicators: To assist in identifying problems, the Switch can be easily monitored with the
LED indicators which help to identity if any problems exist.
Please refer to the LED Indicators section for LED light indication.
If the power indicator LED does not turn on when the power cord is plugged in, the user may have a
problem with the power cord. Check for loose power connections, power losses or surges at the power
outlet.
Please contact Leonton for technical support service, if the problem still cannot be resolved.
If the industrial Switch LED indicators are normal and the connected cables are correct but the packets
still cannot transmit, please check the system’s Ethernet devices’ configuration or status.
For any repair or maintenance needs, please contact us.
LEONTON TECHNOLOGIES, CO., LTD
9F-1, No.43, Fuxing Rd., Xindian Dist.,
New Taipei City, 231,
Taiwan
TEL: +886 2 22183113
FAX: +886 2 22187391
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Leonton PG2-1002-SFP Manuel utilisateur

Catégorie
Commutateurs réseau
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues