Vulcan VGCTS16 Manuel utilisateur

Taper
Manuel utilisateur
INSTALLATION &
OPERATION MANUAL
For additional information on Vulcan or to locate an authorized parts
and service provider in your area, visit our website at www.vulcanequipment.com
VULCAN
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANEQUIPMENT.COM
3600 NORTH POINT BLVD.
BALTIMORE, MD 21222
FORM 31041 Rev. A (May 2018)
GAS TILTING BRAISING PAN
MODEL VGCTS16
MODELS
VGCTS16 ML-152053
Model VGCTS16
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS
EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS
OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT
THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE
LOCAL GAS SUPPLIER.
IMPORTANT
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS
AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS
COMPANY OR GAS SUPPLIER FOR SERVICE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE
PROPERTY DAMAGE, INJURY OR DEATH. READ THE
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
EQUIPMENT.
IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO
OPERATE THIS DEVICE.
RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE
– 2 –
©VULCAN, 2018
– 3 –
TABLE OF CONTENTS
GENERAL .............................................................................................................................................................. 4
INSTALLATION .....................................................................................................................................................4
Unpacking ........................................................................................................................................................4
Location ...........................................................................................................................................................4
Installation Codes and Standards ....................................................................................................................5
Leveling ............................................................................................................................................................5
Gas connections ..............................................................................................................................................5
Testing the Gas Supply System .......................................................................................................................5
Ventilation ........................................................................................................................................................6
Electrical connections ......................................................................................................................................6
OPERATION .........................................................................................................................................................7
Controls (Fig. 1) ...............................................................................................................................................7
Before First Use ...............................................................................................................................................7
Lighting the Tilting Braising Pan ....................................................................................................................... 8
Using the Tilting Braising Pan ..........................................................................................................................8
CLEANING ............................................................................................................................................................9
After Each Use .................................................................................................................................................9
Once A Day ......................................................................................................................................................9
Stainless Steel .................................................................................................................................................9
STAINLESS STEEL EQUIPMENT CARE AND CLEANING ............................................................................10
MAINTENANCE ..................................................................................................................................................12
Lubrication .....................................................................................................................................................12
Vent ................................................................................................................................................................12
Service and Parts Information ........................................................................................................................ 12
TROUBLESHOOTING .......................................................................................................................................12
– 4 –
INSTALLATION, OPERATION AND CARE OF
GAS TILTING BRAISING PAN
MODEL VGCTS16
SAVE THESE INSTRUCTIONS FOR FUTURE USE
GENERAL
Your Vulcan Tilting Braising Pan is a versatile piece of equipment. It allows you to stew, simmer, pan fry,
braise, grill, or sauté, and all with a very uniform heat pattern. Capacity of Model VGCTS16 is 16 gallons
(4.2 liters). The braising pan includes a support stand with drain pan.
Your Vulcan tilting braising pan is produced with quality workmanship and material. Proper installation,
usage and maintenance will result in many years of satisfactory performance.
Vulcan suggests that you thoroughly read this entire manual and carefully follow all of the instructions
provided.
INSTALLATION
Before installing, verify that the gas and electrical service agree with the specications on the rating plate
located on the right side panel as you face the machine. If the supply and equipment requirements do not
agree, do not proceed with the installation. Contact your dealer or Vulcan customer service immediately.
UNPACKING
This tilting braising pan was carefully inspected before leaving the factory. The transportation company
assumes full responsibility for safe delivery upon acceptance of this shipment.
Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is found to be
damaged, save the packaging material and contact the carrier within 5 working days of delivery.
LOCATION
The equipment area must be kept free and clear of combustible substances.
The braising pan is intended for use on non-combustible oors. When installed, minimum clearance from
combustible and non-combustible construction must be 3" (7.6 cm) at the sides and 6" (15.2 cm) at the rear.
The installation location must allow adequate clearances for servicing and proper operation.
The braising pan must be installed so that the ow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber must be provided. Make sure there
is an adequate supply of air in the room suitable for the amount of combustion gas feeding the braising
pan burners.
Do not permit fans to blow directly at the braising pan. Wherever possible, avoid open windows next to
the braising pan. Avoid wall-type fans which create air crosscurrents within the room.
– 5 –
INSTALLATION CODES AND STANDARDS
Your Vulcan tilting braising pan must be installed in accordance with:
In the United States:
1. State and local codes, or in the absence of local codes, with:
2. National Fuel Gas Code ANSI-Z223.1 (latest edition), available from The American Gas Association,
Inc., 1515 Wilson Boulevard, Arlington, VA 22209.
3. National Electrical Code ANSI/NFPA-70 (latest edition), available from The National Fire Protection
Association, Batterymarch Park, Quincy, MA 01169.
4. ANSI NFPA Standard #96 Vapor Removal from Cooking Equipment (latest edition), available from
The National Fire Protection Association, Batterymarch Park, Quincy, MA 01169.
In Canada:
1. Local codes.
2. CAN/CGA-B149.1 National Fuel Gas Code (latest edition), available from The Canadian Gas
Association, 178 Rexdale Boulevard, Etobicoke, Ontario, Canada M9W 1R3.
3. Canadian Electrical Code Part 1 CSA-C22.1 (latest edition), available from The Canadian Standards
Association, 178 Rexdale Boulevard, Etobicoke, Ontario, Canada M9W 1R3.
LEVELING
Place a carpenter's level on top of the braising pan. Turn the adjustable feet to level the braising pan
side-to-side and front-to-back.
GAS CONNECTIONS
Location of the gas inlet is at the rear of the braising pan. Codes require that a gas shuto valve must be
installed in the gas line ahead of the braising pan.
Connect gas supply. Make sure the pipes are clean and free of obstructions.
The braising pan is equipped with xed burner orices which coincide with installation elevation.
Natural gas pressure regulators are preset for 7" (1.47 kPa) W.C. (Water Column).
Prior to lighting, check all joints in the gas supply line for leaks. Use soap and water
solution. Do not use an open ame.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
TESTING THE GAS SUPPLY SYSTEM
When test pressures exceed 1/2 psig (3.45 kPa), the braising pan and its individual shuto valve must be
disconnected from the gas supply piping system.
When test pressures are 1/2 psig (3.45 kPa) or less, the braising pan must be isolated from the gas supply
system by closing its individual manual shuto valve.
– 6 –
VENTILATION
DO NOT obstruct the ow of ue gases from the ue located on the rear of the braising pan. It is
recommended that the ue gases be ventilated to the outside of the building through a ventilation system
installed by qualied personnel.
From the termination of the braising pan ue to the lters of the hood venting system, an 18" (46 cm)
minimum clearance must be maintained.
Information on the construction and installation of ventilating hoods may be obtained from the standard
for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest edition), available from the National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
ELECTRICAL CONNECTIONS
Electrical and grounding connections must comply with the National Electrical
Code and/or other local codes.
Appliances equipped with a exible electric supply cord are provided with a three-
prong grounding plug. It is imperative that this plug be connected into a properly grounded three-
prong receptacle. If the receptacle is not the proper grounding type, contact an electrician. Do
not remove the grounding prong from this plug.
A 120/60/1 supply cord is supplied at the rear of the braising pan.
Do not connect the braising pan to electrical supply until after gas connections have been made.
An electrical diagram is located inside the braising pan control box.
– 7 –
OPERATION
The tilting braising pan and its parts are hot. Use care when operating, cleaning or
servicing the tilting braising pan.
CONTROLS (Fig. 1)
Fig. 1
Thermostat Maintains set temperature by controlling power supply. Temperature
range is from O to 450°F (232°C).
Power Switch Turns the braising pan on and o.
Temperature Light (Red) When lit, indicates burners are providing heat to the braising pan. Light
cycles on and o as burner cycles on and o.
Ignition Light (Green) When lit, indicates ignition has occurred. Light will go out when set
temperature is reached.
Tilting Handle (Not shown.) Pull forward to tilt braising pan; push backward to return
braising pan to the down position.
BEFORE FIRST USE
Use a noncorrosive, grease-dissolving commercial cleaner to clean the protective metal oils from all
surface parts and the interior of the tilting braising pan. Follow the cleaner manufacturer's directions.
Rinse thoroughly and drain the pan. Wipe dry with a soft, clean cloth.
– 8 –
LIGHTING THE TILTING BRAISING PAN
1. Open main gas valve.
2. Ensure braising pan is in the DOWN position.
3. Turn Power Switch ON. Set thermostat dial to desired setting. This will turn on the electronic ignition.
The gas solenoid valve will open, supplying gas to the burner. The RED temperature light and the
GREEN ignition light will come on.
4. If ignition is not achieved, turn the thermostat to OFF and turn the Power Switch to OFF. Wait 5
minutes before repeating steps 2 and 3.
5. When the braising pan reaches set temperature, the RED temperature light and the GREEN ignition
light will go o and the burner will shut o. The burner will cycle on and o to maintain set temperature.
Shutdown
Turn thermostat to OFF. Turn Power Switch to OFF. For extended shutdown, turn thermostat, Power
Switch, and main gas valve OFF.
USING THE TILTING BRAISING PAN
When the braising pan is tilted, power supply to the burner is interrupted. The braising pan can only be
operated in the down position.
To prevent discoloration of stainless steel cooking surface, do not turn the heat on unless the braising pan
is covered with a uid, a thin layer of cooking oil, or food to be cooked.
1. Grasp the tilting handle and tilt the braising pan down as far as it will go and then back to ensure
that it moves easily.
2. Turn the Power Switch ON.
3. Set the Thermostat dial to HIGH (450°F / 232°C).
4. Preheat braising pan and allow it to cycle in order to equalize heat across the entire pan surface.
5. Set the Thermostat dial to the desired cooking temperature.
Approx. Temperature
Function (°F) (°C)
Simmering 200 93
Sautéing 225-275 107-135
Searing 300-350 149-177
Pan Frying 325-375 163-190
Grilling 350-425 177-218
6. At the end of cooking, turn the Thermostat to OFF and turn the Power Switch to OFF.
7. The braising pan is provided with a stationary support for holding the drain pan. When unloading
prepared foods, pull the drain pan out about 17" (432 mm) and place a food receiving pan in it. Tilt
the braising pan to remove product. The drain pan is removable for cleaning.
– 9 –
CLEANING
Disconnect the electrical power to the machine and follow lockout / tagout procedures
before cleaning.
Do not use corrosive cleaning agents
AFTER EACH USE
The tilting braising pan should be cleaned after each use. Clean with warm water and a mild detergent.
Rinse thoroughly and wipe dry with a soft clean cloth.
Your braising pan is equipped with a stand and drain pan accessory, remove the drain pan and clean it in
a sink as you would any utensil.
ONCE A DAY
Thoroughly clean the braising pan with warm water and a mild detergent. Rinse thoroughly and wipe dry
with a soft clean cloth.
STAINLESS STEEL
Clean stainless steel surfaces with a damp cloth and polish with a soft dry cloth. To remove discolorations,
use a non-abrasive cleaner.
– 10 –
STAINLESS STEEL EQUIPMENT CARE AND CLEANING
(Supplied courtesy of NAFEM. For more information, visit their web site at www.nafem.org)
Contrary to popular belief, stainless steels ARE susceptible to rusting.
Corrosion on metals is everywhere. It is recognized quickly on iron and steel as unsightly yellow/orange
rust. Such metals are called “active” because they actively corrode in a natural environment when their
atoms combine with oxygen to form rust.
Stainless steels are passive metals because they contain other metals, like chromium, nickel and manganese
that stabilize the atoms. 400 series stainless steels are called ferritic, contain chromium, and are magnetic;
300 series stainless steels are called austenitic, contain chromium and nickel; and 200 series stainless,
also austenitic, contains manganese, nitrogen and carbon. Austenitic types of stainless are not magnetic,
and generally provide greater resistance to corrosion than ferritic types.
With 12-30 percent chromium, an invisible passive lm covers the steel’s surface acting as a shield against
corrosion. As long as the lm is intact and not broken or contaminated, the metal is passive and stain-
less. If the passive lm of stainless steel has been broken, equipment starts to corrode. At its end, it rusts.
Enemies of Stainless Steel
There are three basic things which can break down stainless steel’s passivity layer and allow corrosion
to occur.
Mechanical abrasion
Deposits and water
Chlorides
Mechanical abrasion means those things that will scratch a steel surface. Steel pads, wire brushes and
scrapers are prime examples.
Water comes out of the faucet in varying degrees of hardness. Depending on what part of the country you
live in, you may have hard or soft water. Hard water may leave spots, and when heated leave deposits
behind that if left to sit, will break down the passive layer and rust stainless steel. Other deposits from
food preparation and service must be properly removed.
Chlorides are found nearly everywhere. They are in water, food and table salt. One of the worst chloride
perpetrators can come from household and industrial cleaners.
So what does all this mean? Don’t Despair!
Here are a few steps that can help prevent stainless steel rust.
1. Use the proper tools.
When cleaning stainless steel products, use non-abrasive tools. Soft cloths and plastic scouring pads
will not harm steel’s passive layer. Stainless steel pads also can be used but the scrubbing motion
must be in the direction of the manufacturers’ polishing marks.
2. Clean with the polish lines.
Some stainless steel comes with visible polishing lines or “grain.” When visible lines are present,
always scrub in a motion parallel to the lines. When the grain cannot be seen, play it safe and use
a soft cloth or plastic scouring pad.
3. Use alkaline, alkaline chlorinated or non-chloride containing cleaners.
While many traditional cleaners are loaded with chlorides, the industry is providing an ever-increasing
choice of non-chloride cleaners. If you are not sure of chloride content in the cleaner used, contact
your cleaner supplier. If your present cleaner contains chlorides, ask your supplier if they have an
alternative. Avoid cleaners containing quaternary salts; it also can attack stainless steel and cause
pitting and rusting.
– 11 –
4. Treat your water.
Though this is not always practical, softening hard water can do much to reduce deposits. There are
certain lters that can be installed to remove distasteful and corrosive elements. To insure proper
water treatment, call a treatment specialist.
5. Keep your food equipment clean.
Use alkaline, alkaline chlorinated or non-chloride cleaners at recommended strength. Clean frequently
to avoid build-up of hard, stubborn stains. If you boil water in stainless steel equipment, remember
the single most likely cause of damage is chlorides in the water. Heating cleaners that contain
chlorides have a similar eect.
6. Rinse, rinse, rinse.
If chlorinated cleaners are used, rinse and wipe equipment and supplies dry immediately. The sooner
you wipe o standing water, especially when it contains cleaning agents, the better. After wiping
equipment down, allow it to air dry; oxygen helps maintain the stainless steel’s passivity lm.
7. Never use hydrochloric acid (muriatic acid) on stainless steel.
8. Regularly restore/passivate stainless steel.
Job Cleaning Agent Comments
Routine cleaning Soap, ammonia,
detergent, Medallion
Apply with soft cloth or sponge.
Fingerprints and smears Arcal 20, Lac-O-Nu Ecoshine Provides barrier lm
Stubborn stains and
discoloration
Cameo, Talc, Zud,
First Impression
Rub in direction of polish lines.
Grease and fatty acids,
blood, burnt-on foods
Easy-o, DeGrease It Oven Aid Excellent removal
on all nishes
Grease and Oil Any good commercial
detergent
Apply with soft cloth or sponge.
Restoration/Passivation Benet, Super Sheen
Review
1. Stainless steels rust when passivity (lm-shield) breaks down as a result of scrapes, scratches,
deposits and chlorides.
2. Stainless steel rust starts with pits and cracks.
3. Use the proper tools. Do not use steel pads, wire brushes or scrapers to clean stainless steel.
4. Use non-chlorinated cleaners at recommended concentrations. Use only chloride-free cleaners.
5. Soften your water. Use lters and softeners whenever possible.
6. Wipe o cleaning agent(s) and standing water as soon as possible. Prolonged contact causes
eventual problems.
To learn more about chloride-stress corrosion and how to prevent it, contact the equipment manufacturer
or cleaning materials supplier.
Developed by Packer Engineering, Naperville, Ill., an independent testing laboratory.
– 12 –
FORM 31041 Rev. A (May 2018) PRINTED IN U.S.A.
MAINTENANCE
The tilting braising pan and its parts are hot. Use care when operating, cleaning
or servicing the braising pan.
Disconnect the electrical power to the machine and follow lockout / tagout procedures
before performing any maintenance.
LUBRICATION
Never grease or oil the pivot bearings as this may cause problems with tilting. Bearings are oilite and
never require lubrication.
VENT
Periodically check the ue, when the braising pan is turned o and is cool, to be sure it is free of obstructions.
SERVICE AND PARTS INFORMATION
To obtain service and parts information concerning this unit, contact the Vulcan Service Agency in your
area, or visit www.vulcanequipment.com.
TROUBLESHOOTING
Problem Possible Cause
Burners do not come on. 1. The power supply is o.
2. The gas supply to the braising pan is o.
3. The gas valve is o.
4. The thermostat is not turned on.
5. The pan is not in the lowest position.
6. Problem with the gas control system. Contact your Vulcan
authorized servicer.
Braising pan dicult to tilt. 1. Dirt in oilite bearings causing it to bind. Call your local Vulcan-
authorized servicer.
MANUEL D’INSTALLATION ET
D’UTILISATION
Pour de plus amples renseignements sur Vulcan ou pour localiser un fournisseur agréé de pièces
ou de services dans votre région, visitez notre site à l'adresse www.vulcanequipment.com
VULCAN
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANEQUIPMENT.COM
3600 NORTH POINT BLVD.
BALTIMORE, MD 21222
FORMULAIRE 31041 Rév. A (mai 2018)
BRAISIÈRE BASCULANTE
MODÈLE VGCTS16
MODÈLES
VGCTS16 ML-152053
Modèle VGCTS16
IMPORTANT POUR VOTRE SÉCURITÉ
CE MANUEL EST DESTINÉ AU PERSONNEL QUALIFIÉ POUR INSTALLER CET ÉQUIPEMENT
À GAZ, QUI DOIT EFFECTUER LE DÉMARRAGE ET LES RÉGLAGES INITIAUX SUR LE
TERRAIN DE L'ÉQUIPEMENT DÉCRIT DANS LE PRÉSENT MANUEL.
AFFICHEZ, DANS UN ENDROIT BIEN EN VUE, LES INSTRUCTIONS À SUIVRE EN CAS
L'ODEUR DE GAZ EST DÉTECTÉE. CETTE INFORMATION PEUT ÊTRE OBTENUE
D'AUPRÈS LE FOURNISSEUR DE GAZ LOCAL.
IMPORTANT
EN CAS UNE ODEUR DE GAZ EST DÉTECTÉE, COUPEZ
L'ALIMENTATION EN GAZ AUX APPAREILS DEPUIS LE ROBINET
D'ARRÊT PRINCIPAL ET CONTACTEZ LA SOCIÉTÉ GAZIÈRE
LOCALE OU LE FOURNISSEUR DE GAZ POUR RÉPARATION.
IMPORTANT POUR VOTRE SÉCURITÉ
N'ENTREPOSEZ PAS ET N'UTILISEZ PAS DE L'ESSENCE
NI D'AUTRES VAPEURS OU LIQUIDES INFLAMMABLES À
PROXIMITÉ DE CET APPAREIL OU DE TOUT AUTRE APPAREIL.
AVERTISSEMENT
UNE INSTALLATION, UN RÉGLAGE, UNE
ALTÉRATION, UN SERVICE OU UN ENTRETIEN INAPPROPRIÉ
PEUT PROVOQUER DES DOMMAGES, DES BLESSURES VOIRE LA
MORT. LISEZ ATTENTIVEMENT LES INSTRUCTIONS RELATIVES
À L’INSTALLATION, AU FONCTIONNEMENT ET À L’ENTRETIEN
AVANT D’INSTALLER OU D’ENTRETENIR CET ÉQUIPEMENT.
EN CAS DE PANNE D’ÉLECTRICITÉ, N’ESSAYEZ PAS DE FAIRE
FONCTIONNER CET APPAREIL.
CONSERVEZ CE MANUEL AUX FINS DE RÉFÉRENCE ULTÉRIEURE
– 2 –
©VULCAN, 2018
– 3 –
TABLE DES MATIÈRES
GÉNÉRALITÉS .....................................................................................................................................................4
INSTALLATION .....................................................................................................................................................4
Déballage .........................................................................................................................................................4
Emplacement ...................................................................................................................................................4
Codes et normes d’installation .........................................................................................................................5
Mise à niveau ...................................................................................................................................................5
Raccordement au gaz ......................................................................................................................................5
Test du système d’alimentation en gaz ............................................................................................................5
VENTILATION ..................................................................................................................................................6
Raccordement électrique .................................................................................................................................6
FONCTIONNEMENT ............................................................................................................................................7
Commandes (fi g. 1) .........................................................................................................................................7
Avant la première utilisation .............................................................................................................................7
Allumer la braisière basculante ........................................................................................................................8
Utiliser la braisière basculante .........................................................................................................................8
NETTOYAGE.........................................................................................................................................................9
Après chaque utilisation ...................................................................................................................................9
Une fois par jour ...............................................................................................................................................9
Acier inoxydable ...............................................................................................................................................9
ENTRETIEN ET NETTOYAGE DE L'ÉQUIPEMENT EN ACIER INOXYDABLE ...........................................10
ENTRETIEN ........................................................................................................................................................12
Lubrifi cation ....................................................................................................................................................12
Ventilation ......................................................................................................................................................12
Renseignements sur l’entretien et les pièces ................................................................................................12
DÉPANNAGE ......................................................................................................................................................12
– 4 –
INSTALLATION, UTILISATION ET ENTRETIEN DES
BRAISIÈRE BASCULANTE À GAZ
MODÈLE VGCTS16
CONSERVEZ CES INSTRUCTIONS AUX FINS DE RÉFÉRENCES ULTÉRIEURES
GÉNÉRALITÉS
La braisière basculante Vulcan est une pièce d’équipement polyvalente. Elle vous permet de faire mijoter, de poêler,
de braiser, de griller ou de sauter, le tout avec une chaleur très uniforme. La capacité du modèle VGCTS16 est de
16 gallons (4,2 L). La braisière comprend un support avec bac de récupération.
La braisière basculante Vulcan est le résultat de haute qualité de fabrication et de matériaux de technologies de pointe.
Une installation, une utilisation et un entretien appropriés se traduiront par plusieurs années de rendement satisfaisant.
Vulcan recommande de lire attentivement ce manuel dans son intégralité et de suivre soigneusement toutes les
instructions fournies.
INSTALLATION
Avant d'installer la braisière, vérifi ez que l'alimentation électrique et de gaz est conforme aux spécifi cations
de la plaque signalétique située sur le côté droit du panneau à l'avant de l’appareil. Si les exigences relatives
à l'alimentation et à l'équipement ne sont pas respectées, ne procédez pas à l'installation. Communiquez
immédiatement avec le service à la clientèle Vulcan.
DÉBALLAGE
Cette braisière basculante a été inspectée soigneusement avant de quitter l’usine. La société de transport
assume l'entière responsabilité de la livraison en bon état puisqu’elle accepte d’eff ectuer cette expédition.
Immédiatement après le déballage, vérifi ez s'il y a des dommages éventuels liés au transport. Si la
braisière est endommagée, conservez le matériel d'emballage et communiquez avec le transporteur dans
les 5 jours ouvrables qui suivent la livraison.
EMPLACEMENT
La braisière doit être dégagée de toute substance combustible.
La braisière de par sa conception doit être utilisée sur des sols non combustibles. Lorsqu’installée, un dégagement
minimum de toute construction combustible et non combustible doit être de 3 po (7,6 cm) aux côtés et de 6 po (15,2 cm)
à l’arrière.
L'emplacement d'installation doit permettre un dégagement adéquat à des fi ns d'entretien et de bon fonctionnement.
La braisière doit être installée de manière à ce que le ux d'air de combustion et de ventilation ne soit pas obstrué. Un
dégagement suffi sant pour les ouvertures d'air dans la chambre de combustion doit être fourni. Assurez-vous qu'il y a
suffi samment d'air dans la pièce, adapté à la quantité de gaz de combustion qui alimente les brûleurs de la braisière.
Ne laissez pas les ventilateurs souffl er directement sur la braisière. Évitez autant que possible les fenêtres ouvertes
près de la braisière. Évitez les ventilateurs muraux qui créent des courants d'air dans la pièce.
– 5 –
CODES ET NORMES D’INSTALLATION
Votre braisière basculante Vulcan doit être installée conformément aux codes ci-après :
États-Unis :
1. Codes d'État et locaux, ou en l'absence de codes locaux :
2. National Fuel Gas Code ANSI-Z223.1 (dernière édition), disponible auprès de l'American Gas
Association, Inc., 1515 Wilson Boulevard, Arlington, VA 22209.
3. National Electrical Code ANSI/NFPA No 70 (dernière édition) disponible auprès de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 01169.
4. Norme 96 Vapor Removal from Cooking Equipment NFPA ANSI (dernière édition), disponible
auprès de la National Fire Protection Association, Batterymarch Park, Quincy, MA 01169.
Au Canada :
1. Codes locaux.
2. Code d’installation du gaz naturel et du propane, CAN/CGA-B149.1 (dernière édition), disponible
auprès de l'Association canadienne du gaz, 178 Rexdale Boulevard, Etobicoke, Ontario, Canada
M9W 1R3.
3. Code canadien de l'électricité partie 1 CSA C22.1, (dernière édition) disponible auprès de l'Association
canadienne de normalisation, 178 Rexdale Boulevard, Etobicoke, Ontario, Canada M9W 1R3.
MISE À NIVEAU
Placez un niveau de menuisier sur le dessus de la braisière. Tournez les pieds de nivellement pour niveler
la braisière d'un côté à l'autre et de l’avant à l’arrière.
RACCORDEMENT AU GAZ
L'emplacement de l'entrée de gaz se trouve à l'arrière de la braisière. Les codes exigent qu'un robinet
d'arrêt de gaz soit installé sur le tuyau de gaz avant l'alimentation en gaz à la braisière.
Raccordez l’alimentation en gaz. Assurez-vous que les tuyaux sont propres et libres d'obstacle.
La braisière est équipée d'orifi ces de brûleur fi xes qui coïncident avec l'élévation de l'installation.
Les régulateurs de pression de gaz naturel sont prédéfi nis pour 7 po (1,47 kPa) CE (colonne d’eau).
AVERTISSEMENT
Avant la mise sous tension, vérifi ez tous les joints du tuyau d'approvisionnement
en gaz pour la présence des fuites. Utilisez une solution d'eau et de savon. N'utilisez pas de
amme nue.
Après que la tuyauterie a été vérifi ée pour la présence de fuites, tous les tuyaux destinés à recevoir le
gaz doivent être entièrement purgés pour éliminer l'air.
TEST DU SYSTÈME D’ALIMENTATION EN GAZ
Lorsque les pressions de test dépassent 1/2 psi (3,45 kPa), la braisière et son robinet d'arrêt individuel
doivent être déconnectés de la tuyauterie d'alimentation en gaz.
Lorsque les pressions de test est de 1/2 psi (3,45 kPa) ou inférieures, la braisière doit être isolée du système
d'alimentation en gaz en fermant son robinet d'arrêt.
– 6 –
VENTILATION
N'obstruez PAS la circulation des gaz de fumée du conduit de fumée situé à l'arrière de la braisière. Il est
recommandé que les gaz de fumée soient évacués à l'extérieur du bâtiment au moyen d'un système de
ventilation installé par du personnel qualifi é.
Un dégagement minimal d'au moins 18 po (46 cm) doit être maintenu entre l'extrémité du conduit de
fumée et les fi ltres du système de hotte de ventilation.
Les renseignements sur la construction et l'installation de hottes de ventilation peuvent être obtenus de
la norme « Vapor Removal from Cooking Equipment », NFPA nº 96 (dernière édition) disponible auprès
de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
RACCORDEMENT ÉLECTRIQUE
AVERTISSEMENT
Les raccordements électriques et à la terre doivent être conformes au Code national
de l'électricité et aux autres codes locaux.
AVERTISSEMENT
Les appareils équipés d'un cordon d'alimentation électrique souple sont fournis
avec une fi che bipolaire avec terre. Il est impératif que cette che soit branchée dans une prise
électrique triphasée. Si la prise n'est pas le type de mise à la terre, contactez un électricien.
N'enlevez pas la broche de mise à la terre de cette fi che.
Un cordon d'alimentation de calibre 120/60/1 est fourni à l'arrière de la braisière.
Ne raccordez pas la braisière à l'alimentation électrique tant que les raccordements de gaz n'ont pas été
eff ectués.
Un schéma électrique est situé à l'intérieur de la boîte de commande de la braisière.
– 7 –
FONCTIONNEMENT
AVERTISSEMENT
La braisière et ses pièces sont chaudes. Faites attention lorsque vous utilisez,
nettoyez ou entretenez la braisière basculante.
COMMANDES ( g. 1)
Fig. 1
Thermostat Maintient la température réglée en contrôlant l'alimentation électrique.
La plage de température est de Off (arrêt) à 450 °F (232 °C).
Interrupteur d'alimentation Pour mettre en marche ou à l’arrêt la braisière.
Voyant de température
(rouge)
Lorsqu'il est allumé, indique que les brûleurs fournissent de la chaleur
à la braisière. Le voyant s'allume et s'éteint lorsque le brûleur s'allume
et s'éteint.
Voyant d’allumage (vert) Lorsqu'il est allumé, cela indique que l'allumage s'est produit. Le voyant
s'éteint lorsque la température réglée est atteinte.
Manche (non représenté.) Poussez le manche vers l'avant pour incliner la
braisière; poussez-le vers l'arrière pour ramener la braisière en position
inférieure.
AVANT LA PREMIÈRE UTILISATION
Utilisez un nettoyant dégraissant et non corrosif de type commercial pour nettoyer les huiles de protection
de métal sur toutes les parties de la surface et l'intérieur de la braisière. Suivez les instructions du fabricant
de nettoyant. Rincez bien et videz la braisière. Essuyez la braisière avec un chiff on doux et propre.
INTERRUPTEUR
D’ALIMENTATION
VOYANT DE
TEMPÉRATURE
VOYANT D’ALLUMAGE
THERMOSTAT
– 8 –
ALLUMER LA BRAISIÈRE BASCULANTE
1. Ouvrez le robinet principale d’alimentation en gaz.
2. Assurez-vous que la braisière se trouve en position INFÉRIEURE.
3. Mettez l'interrupteur d'alimentation sur la position MARCHE. Réglez le bouton du thermostat sur le
réglage souhaité. Cela activera l'allumage électronique. L'électrovanne de gaz s'ouvre, fournissant
du gaz au brûleur. Le voyant de température ROUGE et le voyant d'allumage VERT s'allument.
4. Si l’allumage n'est pas établi, tournez le bouton du thermostat vers OFF (arrêt) et mettez l'interrupteur
d'alimentation en position OFF. Attendez 5 minutes avant de répéter les étapes 2 et 3.
5. Lorsque la braisière atteint la température réglée, le voyant de température ROUGE et le voyant
d'allumage VERT s'éteignent et le brûleur s'éteint. Le brûleur s'allume et s'éteint pour maintenir la
température réglée.
Arrêt
Tournez le bouton de température vers la position OFF (arrêt). Mettez l'interrupteur d'alimentation sur la
position OFF. Pour un arrêt prolongé, éteignez le thermostat, l'interrupteur d'alimentation et tournez le
robinet principal d’alimentation en gaz vers la position d’arrêt.
UTILISER LA BRAISIÈRE BASCULANTE
Lorsque la braisière est inclinée, l'alimentation en courant du brûleur est interrompue. La braisière ne peut
être utilisée qu'en position inférieure.
Pour éviter la décoloration de la surface de cuisson en acier inoxydable, ne chauff ez pas à moins que la
braisière ne soit recouverte d'un liquide, d'une fi ne couche d'huile de cuisson ou d'aliments à cuire.
1. Saisissez le manche et faites incliner la braisière vers le bas aussi loin que possible, puis remettez
le manche vers le haut pour vous assurer que la braisière se déplace facilement.
2. Mettez l'interrupteur d'alimentation sur la position ON (marche).
3. Tournez le bouton du thermostat vers HIGH (450 °F / 232 °C).
4. Préchauff ez la braisière et laissez-la fonctionner afi n d'égaliser la chaleur sur toute la surface du
fond.
5. Tournez le bouton du thermostat vers la température de cuisson désirée.
Température approximative
Fonction (°F) (°C)
Mijoter 200 93
Sauter 225-275 107-135
Saisir 300-350 149-177
Poêler 325-375 163-190
Griller 350-425 177-218
6. À la n de la cuisson, tournez le bouton du thermostat vers OFF (arrêt) et mettez l'interrupteur
d'alimentation en position OFF.
7. La braisière est munie d'un support xe pour maintenir le bac de récupération. Lorsque vous déchargez
des aliments préparés, sortez le bac de récupération d'environ 17 po (432 mm) et placez-y un bac
de réception de nourriture. Inclinez la braisière pour retirer le produit. Le bac de récupération est
amovible aux fi ns de nettoyage.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Vulcan VGCTS16 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues