Chief LCM4U Guide d'installation

Catégorie
Supports de plafond à panneau plat
Taper
Guide d'installation

Ce manuel convient également à

INSTALLATION INSTRUCTIONS
FCA4U
LCM4U
Quad Ceiling Accessory
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
FCA4U / LCM4U
FCA4U / LCM4U Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located within the mounting system of the
FCA4U does not exceed maximum weights listed in Table 1.
Table 1: Weight Capacity
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
IMPORTANT ! : The FCA4U
is designed to be mounted
to a 1-1/2" NPT or NPSM following ANSI/ASME B1.20.1
(Schedule 40, 0.154" minimum thickness steel or
aluminum-ASTM B221) threaded extension column, or a
UL Listed Chief CPA column (not included).
NOTE: The FCA4U accessory is
intended to be used with the
UL Listed CPA Ceiling Plates (not included): CPA330,
CPA365, CPA395.
NOTE: The FCA4U accessory may also be used with the UL
Listed Chief ceiling plates WITHOUT swaged collars
(not included): CMA330, CMA345, CMA395.
NOTE: The UL Listed FCA4U accessory may be used with the
following UL Listed models:
MCM1U
MCM1US
LCM1U
LCM1US
RLC1
RMC1
NOTE: The FCA4U accessory is included with the UL Listed
LCM4U Ceiling Mount. The LCM4U consists of the
FCA4U accessory plus four LCM1U ceiling mounts.
--SAVE THESE INSTRUCTIONS--
MODEL Max Weight
Allowed for
EACH
Display
Total Max Weight Capacity
of Mounting System w/
Accessory
FCA4U
85 lbs
(38.6 kg)
with four LCM1U or MCM1U
340 lbs (154.2 kg)
85 lbs
(38.6 kg)
with four RLC1 or RMC1
340 lbs (154.2 kg)
Installation Instructions FCA4U / LCM4U
3
DIMENSIONS
DIMENSIONS: INCHES
[MILLIMETERS]
FCA4U
10.5
265.9
C/L OF MOUNT
COLUMN SOLD SEPARATELY
DIMENSIONS: INCHES
[MILLIMETERS]
LCM4U - Consists of FCA4U plus four LCM1U mounts
FCA4U / LCM4U Installation Instructions
4
DIMENSIONS (cont’d)
LEGEND
SHOWN WITH SIMULATED
60" SCREENS
SHOWN WITH SIMULATED
55" SCREENS
DIMENSIONS: INCHES
[MILLIMETERS]
LCM4U - Consists of FCA4U plus four LCM1U mounts
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
By Hand
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
Installation Instructions FCA4U / LCM4U
5
TOOLS REQUIRED FOR INSTALLATION
PARTS
1/8" (included)
3/16" (included)
1/2" or 13mm
A (1)
[Quad ceiling accessory]
D (8)
[Rotation ring]
B (1)
[Bottom coupling]
C (1)
10-24 x 1/4"
E (8)
5/16 x 3/4"
F (10)
[Cable zip clip]
G (10)
[Cable tie 5-1/2"]
H (1)
1/8"
FCA4U / LCM4U Installation Instructions
6
INSTALLATION
NOTE: The following procedure assumes that a UL Listed
CMA ceiling plate or CPA ceiling plate (not included)
and
a 1-1/2" NPT or NPSM following ANSI/ASME
B1.20.1 (Schedule 40, 0.154" minimum thickness steel
or aluminum-ASTM B221) threaded extension column,
or a UL Listed Chief CPA column (not included)
have
been properly installed following instructions provided
with ceiling plate and extension column.
Preparing FCA4U
1. OPTIONAL: Add cable zip clips (F) to each arm of quad
ceiling accessory (A). (See Figure 1)
NOTE: Cables may instead be routed through the arms and
columns of the quad ceiling accessory.
Figure 1
Installing FCA4U to 1-1/2" NPT Column
1. Slide quad ceiling accessory (A) up from below onto
installed column (not included). (See Figure 2)
2. Tighten two existing 5/16 x 1-1/2" button head cap screws
in center of quad ceiling accessory. (See Figure 2)
3. Thread bottom coupling (B) onto installed column at base of
quad ceiling accessory until tight, with a minimum of four
threads engaged. (See Figure 2)
4. Install and tighten one 10-24 x 1/4" set screw (C) into
bottom coupling (B). (See Figure 2)
5. Loosen two button head screws tightened in Step 2, and
slide accessory down extension column until it rests on the
bottom coupling (B). (See Figure 2)
6. Tighten two button head cap screws (loosened in Step 5) in
center of quad ceiling accessory. (See Figure 2)
7. Proceed to Installing Mount Assemblies and Screens
section.
1.
Figure 2
Installing FCA4U to CPA Extension Column
NOTE: In following Steps 1 through 7, bottom stop collar and
hardware is included with mount assemblies.
(F)
1
(A)
1
4
3
(C) x 1
(B)
(A)
6
2
5
Installation Instructions FCA4U / LCM4U
7
1. Slide quad ceiling accessory (A) up from below onto
installed column (not included). (See Figure 3)
2. Tighten two existing 5/16 x 1-1/2" button head cap screws
in center of quad ceiling accessory. (See Figure 3)
3. Slide bottom stop collar onto installed column, lining up
holes in collar with holes in column.
Figure 3
4. Install two 5/16" x 1" self-tapping screws through two 5/16"
flat washers, bottom stop collar, and into installed column.
5. Install and tighten 5/16" x 3/4" set screw into bottom stop
collar. (See Figure 3)
6. Loosen two button head screws tightened in Step 2, and
slide accessory down extension column until it rests on the
bottom stop collar. (See Figure 3)
7. Tighten two button head cap screws (loosened in Step 6) in
center of quad ceiling accessory. (See Figure 3)
Installing Mount Assemblies and Screens
NOTE: In the following Steps 1-6, parts not designated with a
letter are included with mount assemblies.
1. OPTIONAL: Slide one rotation ring (D) up onto leg of the
quad ceiling accessory (A). (See Figure 4)
NOTE: The rotation rings only need to be installed if the mount
assemblies will be rotated after installation.
2. Slide mount assembly onto leg of the quad ceiling
accessory.
3. Insert one rotation ring (D) below mount assembly on leg of
the quad ceiling accessory. (See Figure 5)
4. Thread bottom coupling onto leg of quad ceiling accessory
until tight, with a minimum of four threads engaged. (See
Figure 5)
5. Install and tighten one 10-24 x 1/4" set screw into bottom
coupling. (See Figure 5)
Figure 4
Figure 5
6. Install and tighten two 5/16" nylon tipped set screws (E) [OR
two 5/16" set screws included with mount assembly]
through back of mount assembly and against column. (See
Figure 5)
NOTE: The nylon tipped set screws (E) only need to be
installed if the mount assemblies will be rotated after
installation. If no rotation is necessary, use 5/16" set
screws from mount assemblies hardware.
7. Repeat Steps 1 through 6 for remaining mount assemblies.
8. Complete installation following the remaining steps in
the Installation Instructions included with the mount
assemblies.
Cable Management
1. Cables may be routed through columns and arms of
FCA3U.
2. Use cable zip clips (F) and cable ties (G) as required to hold
cables in place.
1
(A)
3
4
5
2
7
6
(D)
(A)
1
(D)
2
4
bottom
coupling
5
10-24 x 1/4"
6
(E) x 2
FCA4U / LCM4U Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P 800.582.6480 / 952.225.6000
F 877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P +31 (0) 495 580 852
F +31 (0) 495 580 845
Asia Pacific A Office No. 1 on 12/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P 852 2145 4099
F 852 2145 4477
Chief, a products division of
Milestone AV Technologies
8800-002459 Rev00
2014 Milestone AV Technologies
www.chiefmfg.com
01/14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Chief LCM4U Guide d'installation

Catégorie
Supports de plafond à panneau plat
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues