STEP 1 - Check for All Required Hardware
• 1-Port Hardened Serial Server
• This Quick Start Guide
USER-SUPPLIED COMPONENTS
• Network and serial cables (not included)
• Power supply (not included)
STEP 2 - UL C1/D2 Installation Information
UL CLASS 1 / DIVISION 2 WARNING INFORMATION
SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS
A, B, C AND D HAZARDOUS LOCATIONS, OR
NONHAZARDOUS LOCATIONS ONLY.
CONVENANT À L’EMPLOI DANS LES SITES
DANGEREUX DE CLASSE I, DIVISION 2, GROUPES
A, B, C ET D, OU DANS LES SITES NON HASARDEUX
SEULEMENT
WARNING - EXPLOSION HAZARD - SUBSTITUTION
OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR
CLASS I, DIVISION 2.
ATTENTION - DANGER D’EXPLOSION - LA
SUBSTITUTION DE COMPOSANTS PEUT ENTRAÎNER
UNE ADÉQUATION À LA CLASSE I, DIVISION 2.
THE UNIT IS TO BE POWERED BY A CLASS 2 POWER
SOURCE, OF A GROUNDED-TYPE, WHEN POWER IS
APPLIED TO THE BARREL CONNECTOR.
L’UNITÉ DOIT ÊTRE ALIMENTÉE PAR UNE SOURCE
D’ALIMENTATION DE CLASSE 2, DE TYPE MISE À LA
TERRE, LORSQUE LE CONNECTEUR DU CANON EST
ALIMENTÉ.
THE POWER CABLE MUST HAVE A MINIMUM RATING
OF 80°C.
LE CÂBLE D’ALIMENTATION DOIT AVOIR UNE
INDICATION MINIMALE DE 80 °C.
POWER CANNOT BE APPLIED TO BOTH THE
TERMINAL BLOCK AND BARREL CONNECTORS
SIMULTANEOUSLY.
L’ALIMENTATION NE PEUT PAS ÊTRE APPLIQUÉE
SIMULTANÉMENT AUX CONNECTEURS DU BORNIER
ET DU BARILLET.
THE USE OF COAXIAL CABLE FOR THE FIELD WIRING SHALL
BE IN ACCORDANCE WITH CLASS 2/CLASS 3 REQUIREMENTS
IN ARTICLE 725 OF THE NEC.
L’UTILISATION D’UN CÂBLE COAXIAL POUR LE CÂBLAGE SUR
SITE DOIT ÊTRE CONFORME AUX EXIGENCES DE CLASSE 2 /
CLASSE 3 DE L’ARTICLE 725 DU NEC.
ONE CONDUCTOR PER TERMINAL
UN CONDUCTEUR PAR BORNE
USE COPPER WIRE ONLY
UTILISER UNIQUEMENT DU FIL DE CUIVRE
WIRE SIZE: 28 TO 16 AWG
TAILLE DE FIL: 28 À 16 AWG
TIGHTENING TORQUE: 5 KG-CM
COUPLE DE SERRAGE: 5 KG-CM
WIRE TEMPERATURE RATING: 105 °C MINIMUM (SIZED FOR 60
°C AMPACITY)
INDICE DE TEMPÉRATURE DU FIL: 105 °C MINIMUM (CALIBRÉ
POUR 60 °C)
80 °C MAXIMUM SURROUNDING AMBIENT AIR
TEMPERATURE
80 °C TEMPÉRATURE AMBIANTE AMBIANTE MAXIMALE