Xmart SUPRA 1005-UL Manuel utilisateur

Catégorie
Alimentations sans interruption (UPS)
Taper
Manuel utilisateur

Ce manuel convient également à

USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 1
VER. 2303.09
ENGLISH
INTERACTIVE UPS
120V NEMA
Technical information on this manual is property of XMART by INTEGRA . This manual Information cannot be copied
or distributed totally or partially without written approval of XMART.
XMART can introduce modifications in their products or manuals without further notice.
XMART is not responsible of mistakes or missing information in this manual.
XMART is not responsible for wrong use a third part can do of this information.
Trademarks and logos in this manual are property of their owners.
USER MANUAL
SUPRA 1005/1505/2005
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 2
1. SAFETY INSTRUCTIONS
SYMBOLS
WARNING / AVERTISSEMENT
ELECTRICAL SHOCK RISK / RISQUE DE CHOC ÉLECTRIQUE
WARNING: It is required to read and understand this
manual. Follow all instructions given in this manual
for starting up and operating this product. Only
qualified technician must start-up, operate and
maintain this product. Keep manuals as a guide for
future consults.
WARNING: This product operates with dangerous
voltages. It must be installed, operated, and
maintained ONLY by qualified technicians trained for
this kind of products. Service personnel MUST know
and understand very well all electric risks related to
this product. UPS manufacturer or distributor will
never be responsible for any accident produced by
lack of knowledge or negligent practices at the
moment of install, starting up, or maintain this
product. UPS manufacturer or distributor is not liable
for any damage that might rise from misusing this
unit or defective installation.
WARNING: If you are not qualified technician do not
try to repair this product.
WARNING: Internal area of this product is locked by
screws. Do not try to access inside the UPS unless
you are a qualified technician. UPS must be checked,
repaired, and maintained by qualified personnel only.
AVERTISSEMENT: Il est nécessaire de lire et de
comprendre ce manuel. Suivez toutes les instructions
données dans ce manuel pour le marrage et
l'utilisation de ce produit. Seul un technicien qualifié
doit démarrer, utiliser et entretenir ce produit.
Conservez les manuels comme guide pour les
consultations futures.
AVERTISSEMENT: Ce produit fonctionne avec des
tensions dangereuses. Il doit être installé, utilisé et
entretenu UNIQUEMENT par des techniciens qualifiés
formés pour ce type de produits. Le personnel de
service DOIT connaître et comprendre très bien tous
les risques électriques liés à ce produit. Le fabricant
ou le distributeur de l'UPS ne sera jamais
responsable de tout accident causé par un manque
de connaissances ou des pratiques négligentes lors
de l'installation, du démarrage ou de l'entretien de ce
produit. Le fabricant ou le distributeur de l'UPS n'est
pas responsable des dommages pouvant résulter
d'une mauvaise utilisation de cet appareil ou d'une
installation défectueuse.
AVERTISSEMENT: Si vous n'êtes pas un technicien
qualifié, n'essayez pas de réparer ce produit.
AVERTISSEMENT: La zone interne de ce produit est
verrouillée par des vis. N'essayez pas d'accéder à
l'intérieur de l'onduleur à moins d'être un technicien
qualifié. L'onduleur doit être vérifié, réparé et
entretenu uniquement par du personnel qualifié.
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 3
ELECTRICAL SHOCK RISK / RISQUE DE CHOC ÉLECTRIQUE
PRÉCAUTION: Il y a des tensions dangereuses dans
les prises de courant de l'UPS bien que l'équipement
ne soit pas branché sur la ligne électrique.
PRÉCAUTION: À l'intérieur de cet équipement, en
raison des batteries internes, il y a TOUJOURS des
tensions dangereuses, même l'UPS est éteint et
débranché de la ligne électrique.
WARNING EQUIPMENT DISPOSAL: / AVERTISSEMENT ÉLIMINATION DE L'ÉQUIPEMENT
UNITÉS HORS SERVICE: Il est fortement
recommandé de mettre au rebut cet équipement
conformément aux directives en vigueur dans votre
pays. Au moment de l'élimination, toutes les pièces
doivent être gérées de manière appropriée pour éviter
d'éventuels dommages à l'environnement ou pour
que certains matériaux soient recyclés.
PILES: Ne pas jeter au feu (risque d'explosion).
N'ouvrez pas les piles, il y a des liquides dangereux à
l'intérieur.
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 4
2. SAFETY & QUALITY STANDARDS
SAFETY - LOW VOLTAGE DIRECTIVE (2014/35/EU)
UPS Part 1-1: General & Safety UPS in accessible areas
IEC/EN 62040-1
ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE ( 2014/30/EU)
UPS, Part 2, Electromagnetic Compatibility:
IEC/EN 62040-2
Low Freq. Conducted Disturbances & Signals:
IEC/EN 61000-2-2
Electrostatic discharge immunity Test:
IEC/EN 61000-4-2
(Air: Level 3, Contact: Level 2)
Radiated radio Frequency immunity:
IEC/EN 61000-4-3 (Level 3)
Electrical Fast Transient / burst immunity:
IEC/EN 61000-4-4 (Level 3)
Surge Immunity:
IEC/EN 61000-4-5
(L-L: Level 2, L-G: Level 3)
UPS Part 3: Methods of operation, specifications, and test requirement
IEC/EN 62040-3
IT Equipment. SAFETY. Part 1: General Requirements
IEC/EN 60950-1
For 220V MODELS:
CE compliant
For 120V MODELS (1005-UL/1505-UL/2005-UL):
UL1778 (by cTUVus)
IP PROTECTION
IP20 (static)
QUALITY MANAGEMENT:
Manufactured under:
ISO 9001 : 2000
ENVIRONMENTAL MANAGEMENT:
Manufactured under:
ISO 14001 : 2004
Changes or modifications not expressly approved by the
party responsible for compliance could void the user´s
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
Any modification made by user or operator may affect
compliance of the safety and performance certifications
listed above. UPS manufacturer is not responsible of any
modification made on the product or its accessories after it
is manufactured.
Les changements ou modifications non expressément
approuvés par la partie responsable de la conformité peuvent
annuler l'autorité de l'utilisateur à utiliser l'équipement.
REMARQUE: cet équipement a été testé et déclaré conforme
aux limites d'un appareil numérique de classe A,
conformément à la partie 15 des règles de la FCC. Ces
limites sont conçues pour fournir une protection raisonnable
contre les interférences nuisibles lorsque l'équipement est
utilisé dans un environnement commercial. Cet équipement
génère, utilise et peut émettre de l'énergie de radiofréquence
et, s'il n'est pas installé et utilisé conformément au manuel
d'instructions, peut causer des interférences nuisibles aux
communications radio. L'utilisation de cet équipement dans
une zone résidentielle est susceptible de provoquer des
interférences nuisibles, auquel cas l'utilisateur devra corriger
les interférences à ses propres frais.
Toute modification apportée par l'utilisateur ou l'opérateur
peut affecter la conformité des certifications de sécurité et de
performance énumérées ci-dessus. Le fabricant de l'onduleur
n'est pas responsable de toute modification apportée au
produit ou à ses accessoires après sa fabrication.
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 5
Ce produit est conçu pour fonctionner dans un
environnement domestique et commercial.
Il s'agit d'un produit de catégorie C2. Dans un environnement
résidentiel, ce produit peut provoquer des interférences radio,
dans ce cas l'utilisateur peut exiger de prendre des mesures
supplémentaires.
3. BATTERY MAINTENANCE
Batteries capacity, in general (of all kinds), decreases with time and use.
Our products contain high quality batteries only.
Batteries useful life in our UPS is between 3 and 5 years, considering environment temperature under
25ºC and optimal operational conditions. This time can be dramatically reduced by high temperature and
other adverse operation condition.
Batteries life expectancy may be also affected by other operation conditions such as electrical service
quality as well as number and kind of equipment connected to UPS.
Batteries should be periodically tested to check capacity and assure and appropriate back up.
* To enlarge batteries life expectancy, it is recommendable to fully discharge UPS once every 3 months
* During long UPS storage recharge batteries according to following table:
STORAGE TEMPERATURE
FREQUENCY
RECHARGING TIME
-25°C a +30°C
Every 4 months
4 h
+30°C a +45°C
Every 2 months
4 h
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 6
4. UPS DESCRIPTION
This equipment is known as UPS (Uninterruptible Power Supply). It has 2 main functions: give electrical
protection against surges, spikes and some other dangerous failures of electrical main system and provides
electrical backup based on internal batteries. In that way products you connect to your UPS will be protected
and will receive electrical energy even during failures of main electrical AC system.
This UPS is designed to satisfy all requirements of Personal Computers (PCs). It includes internal voltage
regulator to stabilize input AC variations without using internal batteries. Only in presence of important input
failures UPS will use internal batteries to provide energy in outlet sockets. In this way batteries life expectancy is
longer.
Parts Identification
A.- ON/OFF
B.- LCD Touchscreen
1.- Outputs (battery backup)
2.- Outputs (Surge protected)
3.- AC Input
4.- Input Breaker
5.- RJ-45 protected sockets
6.- USB port
7.- RS-232 port (1005 Model only)
RS232 COMMUNICATION PORT (1005 Model only)
RS232 Comm. Cable to connect UPS and PC must have 1:1 pin connection.
Serial Port pin Identification:
Pin 2: RX: Data Reception
Pin 3: TX: Data Transmission
Pin 5: GND: Grounding
This UPS will provide backup energy in its outlets when main AC input fails. Runtime will depend on different
factors:
Battery charging level.
Battery capacity according to the use given and lifetime.
Load consumption connected to UPS outlets. Higher the output load shorter the runtime.
Under normal condition, when UPS is ON and connected to AC source, UPS will keep batteries fully charged.
NOTE: For Self-protection, all models of this family have a Max. backup time of 240 Minutes, limited by UPS
electronic.
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 7
5. UPS INSTALLATION
CONSERVEZ CES INSTRUCTIONS Ce manuel
contient des instructions importantes pour les
modèles SUPRA 1005/1505/2005 qui doivent être
suivies lors de l'installation et de l'entretien de
l'onduleur et des batteries.
L'entretien des batteries doit être effectué ou
supervisé par du personnel connaissant les batteries
et les précautions requises.
Lors du remplacement des piles, remplacez-les par
des piles ou des blocs-piles du même type et du
même nombre.
ATTENTION: Ne jetez pas les piles au feu. Les piles
peuvent exploser.
ATTENTION: Ne pas ouvrir ou mutiler les batteries.
L'électrolyte libéré est nocif pour la peau et les yeux.
Il peut être toxique.
ATTENTION: Une batterie peut présenter un risque de
choc électrique et de courant de court-circuit élevé.
Le contact avec n'importe quelle partie d'une batterie
mise à la terre peut entraîner un choc électrique. Les
précautions suivantes doivent être observées lorsque
vous travaillez sur des batteries :
a) Retirez montres, bagues ou autres objets
métalliques.
b) Utilisez des outils avec des poignées isolées.
c) Portez des gants et des bottes en caoutchouc.
d) Ne posez pas d'outils ou de pièces métalliques sur
les batteries.
e) Déconnectez la source de charge et la charge
avant d'installer ou d'entretenir la batterie.
f) Retirez les masses de batterie pendant l'installation
et l'entretien pour réduire la probabilité de choc.
Retirez la connexion de la terre si une partie de la
batterie est déterminée comme étant mise à la terre.
ATTENTION : RISQUE D'EXPLOSION SI LA BATTERIE
EST REMPLACÉE PAR UN TYPE INCORRECT. JETEZ
LES PILES USAGÉES SELON LES INSTRUCTIONS
La prise de courant doit être installée à proximité de
l'équipement et doit être facilement accessible.
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 8
This UPS must be installed indoor with controlled environment free of excessive dust and, corrosive air.
Do not install in outdoor. Keep UPS working under operational conditions listed in specifications table of
this manual. Keep out of direct sun light, water, and heat sources.
Do not install UPS close to PC screen to avoid interference. UPS must be at least at 20cm from screen.
Connect LAN cable to RJ45 port in this UPS identified as IN. Connect RJ-45 out to your PC LAN socket.
Plug power cord of this UPS to AC source socket.
Plug your products to UPS AC outlets.
This unit MUST NOT be installed into closed boxes/cabinets that avoid fresh air access. During normal
operation, this unit needs fresh air to flow through ventilation system (Vents) to cool power circuits.
Installing this unit in a closed box/cabinet makes inner air to be recycled without refreshing, increasing
inside temperature, exceeding operation max. temperature, and causing permanent damage to the UPS.
IMPORTANT WARNINGS / AVERTISSEMENTS IMPORTANTS:
Make sure UPS is plugged to AC source
compatible with UPS electrical specifications.
Check UPS specs in UPS label.
Make sure your products input voltage is
compatible with UPS voltage output.
Check total load in Watts to be connected to
UPS is not higher to maximum UPS capacity.
Do NOT plug neither laser printers nor copiers to
this UPS. This equipment are high load products
will overload your UPS.
Assurez-vous que l'UPS est branché sur une
source CA compatible avec les spécifications
électriques de l'UPS. Vérifiez les spécifications
UPS sur l'étiquette UPS.
Assurez-vous que la tension d'entrée de vos
produits est compatible avec la tension de sortie
de l'onduleur.
Vérifiez que la charge totale en watts à connecter
à l'UPS n'est pas supérieure à la capacité
maximale de l'UPS.
Ne branchez PAS d'imprimantes laser ni de
copieurs sur cet onduleur. Ces équipements
sont des produits à forte charge qui
surchargeront votre onduleur.
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 9
6. OPERATION
Once UPS is installed and connected according to section 4 of this manual, please turn UPS on by
ON/OFF button in front panel. Front panel green LED must turn ON.
Turn your products ON one by one.
After finishing your products will be fully protected by the UPS.
This UPS has COLD-START function that allows to turn UPS on even during a failure in the main AC source.
7. LCD
LCD shows valuable information about Utility and UPS data but also provides alarm codes for easy
troubleshooting. User can skip from screen to screen by simple touching LCD.
Note: Below table shows screens for 220V model. In 120V models, input & output values will be close to 120V.
NORMAL MODE BATTERY MODE ALARM BEEP CODE TROUBLESHOOTING
OUTPUT
SALIDA
Continuous
Beep continuo
Output Shorcircuit:
Remove faulty
equipment from UPS
output
INPUT
ENTRADA
Continuous
Beep continuo
Overload:
Remove non critical
equipments from UPS
output
LOAD
CONSUMO
Continuous
Beep continuo
Overcharge:
Call technical service
BATTERY
BATERIA
Continuous
Beep continuo
Battery Low:
Recharge during 6
hours. If not solved call
tech. service
OVERLOAD
SOBRECARGA
Continuous
Beep continuo
Output Hight under
battery mode:
Call Tech. Service
Mode Symbol
Símbolo de
Modo
Continuous
Beep continuo
High Temperature:
Call Tech. Service
UTILITY & UPS INFORMATION
ALARM & ERROR CODES
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 10
8. CONTROL SOFTWARE
Most of the models of this UPS family come with USB port to communicate with your PC. In that way UPS can
be monitored and configured. Your PC can be shutdown automatically when input AC failure is detected saving
your information and providing a controlled shutdown. Event log and alarms can also be monitored from your
PC. Control software can be downloaded from our website: www.xmart-ups.com. We keep updated last
updated version. User manual and installation manual is also available in our web.
Our software is available in different versions for: Windows, Mac OSX, Linux, and Unix.
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 11
9. AFTER SALES SUPPORT & WARRANTY
Support: If a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved,
please contact authorized service center or authorized dealer.
Batteries: Rechargeable batteries can be charged and discharged hundreds of times. However, they will eventually wear out.
This is not a defect or failure so that batteries wear out is not covered by this warranty.
Battery lifetime will depend on operative conditions like working temperature, type, and frequency of discharging cycles. Higher
the temperature shorter will be the lifetime. Frequent and deep discharging cycles also will short lifetime. For critical applications
batteries should be revised and replaced periodically. Long storage (longer than 6 months) without required recharging will wear
out batteries. This situation is not covered by this limited warranty since this is not considered as a defect. Check recharging
instructions on user manual.
Conditions Limited Warranty “PLUS”
1.- Subject to the conditions of this limited warranty, this product is warranted to be free from defects in materials and
workmanship at the time of XMART supplies the product.
In Europe, warranty time is 2 years on electronic parts and 2 years on internal batteries from XMART invoice date.
In America, standard warranty times could vary depending on country/region or can be extended by purchasing
warranty options. Please check warranty plans and extensions with your local distributor.
2.- If during the warranty period, this product fails to operate under normal use and service, due to defects in materials or
workmanship, authorized distributor or service center will, at their option, either repair or replace the product in accordance with
terms and conditions stipulated herein. Transportation expenses are not covered by this limited warranty.
3.- Warranty is valid only if the original invoice issued by XMART, specifying date of purchase, serial number, and name of the
dealer, is presented with the product to be revised. XMART and authorized partners reserve the right to refuse warranty service if
any of this information has been removed, changed, or missing in original invoice document.
4.- If product is repaired or replaced, repaired, or replaced product will be warranted for the remaining time of the original
warranty or for 90 days on repaired part from date of repair, whichever is longer.
5.- XMART or their distribution/service partners reserve the right to charge handling fee if returned product is free of failure or it
is out of warranty because any of the reasons described in this warranty.
6.- If product is out of warranty a reparation proposal will be sent to the user for his approval. If proposal is not accepted,
service center will keep product available for the user during 60 continuous days. After this period product would be disposed
and user will not be able to rise any claim.
7.- Rechargeable batteries, like included in this product, will definitively wear out even under normal operation. This is not a
defect or failure, so it is not covered by this warranty.
8.- This warranty does not cover batteries wear out caused by improper or long storage (over 6 months without required
recharging indicated in product manual). Even performing recharging procedure this product cannot be storage longer than 18
months. Problems on batteries caused by this kind of long storage are not covered by this warranty.
9.- This warranty does not cover product failures caused by installations, modifications or repair performed by non-authorized
person. If product is open by not authorized technician warranty will be considered void. This warranty does not cover failure
caused by inadequate installation or maintenance, misuse, accidents, fire, or floods.
10.- This product can include protection devices like input fuse or input breaker. Activation of this kind of devices is not a failure
it is caused by an improper product installation. Input fuse or breaker reset, or replacement is not covered by this warranty.
11.- This warranty does not cover damages produced during transportation from user to technical service caused by improper
packing of the product by user.
12.- Warranty terms and conditions cannot be modified or extended by third parties without written approval of XMART.
Limited Warranty “PLUS”
- XMART does not warrant that the operation of this product will be uninterrupted or error-free during its lifetime. If product fails
to work, the maximum liability of XMART under this limited warranty is expressly limited to the lesser of the price you have paid
for the product or the cost of repairing or replacement of any hardware components that malfunction in conditions of normal
use.
- In no event will XMART be liable for any damages caused by the product or the failure of the product to perform, including any
lost profits or savings or special, incidental, or consequential damages. XMART is not liable for any claim made by a third party
to XMART or to final user.
- XMART is not responsible for damage that occurs because of your failure to follow the instructions intended for this hardware
product.
- XMART is not responsible for damage that occurs because of your failure to follow the instructions intended for this hardware
product.
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 12
10. TECHNICAL SPECIFICATIONS
INTERACTIVE UPS 1005 1505 2005
Capacity / Capacidad 1,000VA / 600W 1,500VA / 900W 2,000VA / 1200W
Nominal Voltage / Voltaje Nominal
Voltage Range / Rango de Voltaje
Frequency / Frecuencia
Powercord / cable entrada
Generator Compatible / Compatible con motogeneradores
Voltage / Voltaje
Frequency / Frecuencia
Transfer Time / Tiempo Transferencia
Waveform / Forma de Onda (Normal Mode)
Waveform / Forma de Onda (Battery Mode)
Type / Tipo
Capacity / Capacidad
7AH 9AH 9AH
Quantity / Cantidad
2 pcs/pzs 2 pcs/pzs 2 pcs/pzs
Back-up Time Typical / Autonomía Típica (N1*) 40 min. max. 55 min. max. 55 min. max.
Recharge Time / Tiempo de Recarga
Protections / Protecciones
Interface / Interfaz
Acoustic Alarm / Alarma Sonora
Operation Mode / Modo de Operación
Alarms / Alarmas
LCD Information / Información en Pantalla
Input Circuit Breaker / "Breaker" de Entrada
Surge/Spikes Protection (Line H-N)
Protección contra Picos / Rayos (Línea L-N)
Surge & Spikes Prot. / Prot. Picos & Rayos (RJ11/RJ45)
Total Surge Suppression / Supresión Total
Power Outlets / Tomas de Salida
1005 / 1505 / 2005 - NEMA 120V (UL1778)
LCD Touch Secreen / LCD Táctil
Communication / Comunicación USB+RS232 USB USB
Software / Software
Operating / Condiciones de Operación:
Product Size & Net Weight (DxWxH)
Dimensiones & Peso Neto del Producto
325 x 135 x 185 mm
8.5 Kg
325 x 135 x 185 mm
10.5 Kg
325 x 135 x 185 mm
11.2 Kg
Operating / Condiciones de Operación:
Acoustic Noise / Ruido Acustico ≤ 40 dB @ 1 m ≤ 45 dB @ 1 m ≤ 45 dB @ 1 m
Operating Altitude / Altura Operativa
Unit Size & Gross Weight (DxWxH)
Dimension & Peso Bruto Unitario
399 x 198 x 280 mm
9 Kg
399 x 198 x 280 mm
10.8 Kg
399 x 198 x 280 mm
11.8 Kg
Half Pallet Information / Información Medio Pallet
DxWxH
60pcs / 555Kg
120 x 100 x 127cm
60pcs / 663Kg
120 x 100 x 127cm
60pcs / 723Kg
120 x 100 x 127cm
Full Pallet Information / Información Full Pallet
DxWxH
105pcs / 960Kg
120 x 100 x 225cm
105pcs / 1149Kg
120 x 100 x 225cm
105pcs / 1254Kg
120 x 100 x 225cm
American
Conduction & Radiation (Models 120V)
Quality & Enviroment
< 95% RH / 0-40 ºC
0-2000m (Over sea level / Sobre el nivel del mar)
Touch LCD to go to next value on screen / Tocar el LCD para ir al siguiente valor en pantalla
Compatible: Windows family; Mac OS; Linux; Unix
< 95% RH / 0-40 ºC / < 40 dB
RoHS / ISO9001 & ISO14001
Tech. Specs. may change without further notice or to comply with special project requirements. Las especif. pueden cambiar sin aviso previo o para cumplir con proyectos.
N1*: Times for 1PC + TFT load / Tiempos para 1PC + Pantalla TFT
Packing / Empaque: 1 unit per carton / Cartón individual
Safety & Standards
UL1778 (certified by cTÜVus)
FCC Part 15 Class A
Protections / Protecciones
With Reset / Rearmable
Power Outlet with surge & spikes protection: L-N
Tomas de Salida Protegidas contra Picos/Rayos: L-N
> 758J
Tel/Internet/Ethernet RJ45/RJ11
Features / Funcionalidades
8 x NEMA5-15R (6 with Backup + 2 Surge Protected)
Alarm & fault codes are presented on LCD / Alarmas y códigos de falla en LCD
Input/Output Voltage, UPS mode, Battery level (%), load (%), Alarm codes //
Voltajes de entrada y salida, Nivel de baterías (%), Carga (%), Alarmas
Sinewave / Sinusoidal
Simulated Sinewave / Sinusoidal Sintetizada
Batteries / Baterías
Sealed Lead Acid - Maintenance Free (VRLA AGM) / Acido Plomo Sellada Sin Mtto. (VRLA AGM)
Touch LCD / Pantalla LCD táctil
Deep discharge and overcharge / Descarga Profundas y Sobre-Cargas
Alarms-Indications / Alarmas-Indicaciones
4-6 hours to 90% capacity / 4-6 Horas hasta 90% de capacidad
Battery Mode / Low Battery / Overload / Battery Replacement / UPS Fault
Dedicated symbols for each operation mode on LCD / Modo de operación en LCD
Input / Entrada
89-145 Vac
110 Vac - 120 Vac (Default 120 Vac)
60Hz (+/- 1Hz) - 50Hz (+/- 1Hz)
2 - 6 ms typical / típico
60 Hz / 50 Hz: Auto Sensing / Autodetección
6 feet (1.83m) NEMA5-15P
Yes /
Output / Salida
+/- 10%
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 13
NOTES:
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 14
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 15
USER MANUAL - SUPRA 1005/1505/2005
www.xmart-ups.com VER. 2303.09-AP-ENG 16
USA
Miami FL 33196, USA
EUROPE
Sabadell, Barcelona. 08202. Spain
LATAM
Santiago de Chile, Chile
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Xmart SUPRA 1005-UL Manuel utilisateur

Catégorie
Alimentations sans interruption (UPS)
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues