Baumer ZUSBM-ALL.IOL Mode d'emploi

Taper
Mode d'emploi
11048016
Í?+$p0ÂÂ*Â@Î
1/1
Canada
Baumer Inc.
CA-Burlington, ON L7M 4B9
Phone +1 (1)905 335-8444
China
Baumer (China) Co., Ltd.
CN-201612 Shanghai
Phone +86 (0)21 6768 7095
Denmark
Baumer A/S
DK-8210 Aarhus V
Phone +45 (0)8931 7611
France
Baumer SAS
FR-74250 Fillinges
Phone +33 (0)450 392 466
Germany
Baumer GmbH
DE-61169 Friedberg
Phone +49 (0)6031 60 07 0
India
Baumer India Private Limited
IN-411038 Pune
Phone +91 20 2528 6833/34
Italy
Baumer Italia S.r.l.
IT-20090 Assago, MI
Phone +39 (0)2 45 70 60 65
Singapore
Baumer (Singapore) Pte. Ltd.
SG-339412 Singapore
Phone +65 6396 4131
Sweden
Baumer A/S
SE-56133 Huskvarna
Phone +46 (0)36 13 94 30
Switzerland
Baumer Electric AG
CH-8501 Frauenfeld
Phone +41 (0)52 728 1313
United Kingdom
Baumer Ltd.
GB-Watchfield, Swindon, SN6 8TZ
Phone +44 (0)1793 783 839
USA
Baumer Ltd.
US-Southington, CT 06489
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Schnittstellenzubehör
Interface accessories
Accessoires d'interface
IO-Link Master zur Verbindung über
USB
IO-Link master for USB connection
Allgemeine Hinweise
Bestimmungsgemässer Gebrauch
Dieses Produkt ist ein Präzisionsgerät und dient zur
Erfassung von Objekten, Gegensnden und
Aufbereitung bzw. Bereitstellung von Messwerten
als elektrische Gsse für das Folgesystem.
Sofern dieses Produkt nicht speziell gekennzeichnet
ist, darf dieses nicht für den Betrieb in
explosionsgehrdeter Umgebung eingesetzt werden.
Inbetriebnahme
Einbau, Montage und Justierung dieses Produktes
rfen nur durch eine Fachkraft erfolgen.
Montage
Zur Montage nur die r dieses Produkt vorgesehenen
Befestigungen und Befestigungszuber verwenden.
Nicht benutzte Ausgänge dürfen nicht beschaltet werden.
Bei Kabelaushrungen mit nicht benutzten Adern,
ssen diese isoliert werden. Zulässige Kabel-
Biegeradien nicht unterschreiten. Vor dem elektrischen
Anschluss des Produktes ist die Anlage spannungsfrei
zu schalten. Wo geschirmte Kabel vorgeschrieben
werden, sind diese zum Schutz vor elektromagnetischen
Störungen einzusetzen. Bei kundenseitiger Konfektion
von Steckverbindungen an geschirmte Kabel, sollen
Steckverbindungen in EMV-Ausführung verwendet
und der Kabelschirm muss grossfchig mit dem
Steckergehäuse verbunden werden.
General notes
Rules for proper usage
This product is a precision device which has been
designed for the detection of objects and parts.
It generates and provides measured values issued
as electrical signals for following systems.
Unless this product has not been specifically
marked it may not be used in hazardous areas.
Set-up
Installation, mounting and adjustment of this product
may only be executed by skilled employees.
Installation
Only mounting devices and accessories specifically
provided for this product may be used for installation.
Unused outputs may not be connected.
Unused strands of hard-wired sensors must be isolated.
Do not exceed the maximum permissible bending radius
of the cable. Before connecting the product electrically
the system must be powered down. Where screened
cables are mandatory, they have to be used in order to
assure EMI protection. When assembling connectors and
screened cables at customer site the screen of the cable
must be linked to the connector housing via a large
contact area.
Indications d‘ordre général
Affectation
Ce produit est un appareil de précision. Il sert
à la détection d’objets, de pièces, ainsi qu’au
traitement et à la transmission de valeurs de
mesure sous forme d’une grandeur électrique.
Si ce produit n’est pas spécialement désigné,
il ne peut être utilisé dans des environnements
présentant un risque d’explosion.
Mise en service
L’installation, le montage et le réglage de ce produit
ne peut être effectué que par une personne spécialisée.
Montage
Pour le montage, n’utiliser que les fixations et les
accessoires prévus pour ce produit. Les sorties non
utilisées ne doivent pas être raccordées. Dans le cas
d’exécutions avec câble, les fils non utilisés doivent être
isolés. Ne pas dépasser le rayon de courbure autorisé
pour le câble. Mettre impérativement l’installation hors
tension avant de procéder au raccordement du produit.
Dans les cas où des câbles blindés sont demandés, ils
doivent être absolument utilisés afin d’éviter les
perturbations d’ordre électromagnétiques. Dans le cas
où des câbles blindés avec connecteurs sont confectionnés
par le client, il faut utiliser des connecteurs conformes CEM
et le blindage du câble doit être relié au connecteur.
Alle Masse in mm
All dimensions in mm
• Toutes les dimensions en mm
Abmessungen Dimensions
Dimensions
Weitere Informationen
More information
Information complémentaire
O500.ZR-GW1T.72O
USB IO-Link Master
Maître IO-Link pour la connexion
USB
http://www.baumer.com/PID/11048016
• Herunterladen der Software und der Bedienungsanleitung
• Download of software and manual
• Le téléchargement du logiciel et manuel
M12 x 1
15,5 54
41,4
24
DC 24V
PWR LED
Mini USB B
Error
Pin 4
Pin 2