United States Stove Company VG5717 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
© 2022 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
Owner’s Instruction and Operation Manual
U.S. Environmental Protection Agency
Certied to comply with 2020 particulate
emissions standards.
SAFETY NOTICE: If this heater is not properly installed, a house re may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or re ocials about
permits, restrictions and installation requirements in your area. NEVER OPERATE THIS
PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
Save These Instructions In A Safe Place For Future Reference.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals
including carbon monoxide, which is known to the
State of California to cause cancer, birth defects,
and/or other reproductive harm. For more
information, go to www.P65warnings.ca.gov
853928-1503L
VG5717-P
Certied to ASTM E1509-12 (2017)
and Certied to ULC-S627-00-REV1
Mobile Home Approved
R
Report #: F22-777
Model Number:
2
© 2022 United States Stove Company
Heating Specications
Fuel Burn Rate* (lowest setting) 1.9 lbs./hr.
Burn Time (lowest setting) 32 hrs. (approximate)
Hopper Capacity 90 lbs (40.8kg)
Electrical Specications
Electrical Rating 120V, 60 Hz, 3.0 Amps
Watts (operational) 180W
Watts (igniter running) 260W
Dimensions
Overall: Height x Width X Depth 32-7/8” X 24-3/4” X 24-3/8” (836mm X 630mm X 621mm)
Your pellet stove has been approved for installation in the USA and Canada. It may also be installed in a manufactured
or mobile home. Your stove is Certied to ASTM E1509-12 (2017) and Certied. This manual describes the installation
and operation of the Ashley, pellet stove. This heater meets the 2020 U.S. Environmental Protection Agencys crib wood
emission limits for wood-heaters sold after May 15, 2020. Under specic EPA test conditions this heater has been shown
to deliver heat at a rate of 11,871 to 30,884 Btu/hr. This heater achieved a particulate emissions rate of 1.6 g/hr when
tested to method ASTM E 2779 and 77% eciency.
WARNING:
IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE
OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL.
INTRODUCTION
For Customer Service, please call:
1-800-750-2723 Ext 5050 or;
Text to 423-301-5624 or;
Email us at:
customerservice@usstove.com
Note: Register your product online at
www.usstove.com or download the free
app today. This app is available only
on the App Store for iPhone and iPad.
Search US Stove. Save your receipt with
your records for any claims.
© 2022 United States Stove Company
3
INSTALLATION CHECKLIST
Your Wood Stove should be installed by a qualied installer only. An NFI qualied Installer can be found at www.ncertied.
org/public/nd-an-n-pro/
CUSTOMER SERVICE
1-800-750-2723 ext 5050
Text to 423-301-5624
Email to: Customerservice@usstove.com
COMMISSIONING CHECKLIST
This checklist is to be completed in full by the qualied person who installs this unit. Keep this page for future reference.
Failure to install and commission according to the manufacturer’s instructions and complete this checklist will invalidate
the warranty.
Please Print
Customer Name: Telephone Number:
Address:
Model:
Serial Number:
Installation Company Name: Phone Number:
Installation Technician’s Name: License Number:
DESCRIPTION OF WORK
Location of installed appliance: _____________________________________________________________________________________
Venting System: New Venting System Yes No If yes, Brand ______________________________________________
If no, Date of inspection of existing venting system: __________________________________________________________________
COMMISSIONING
Conrm Hearth Pad Installation as per Installation Instructions .........................................................................................
Conrm proper placement of internal parts ...........................................................................................................................
Check soundness of door gasket and door seals .................................................................................................................
Conrm clearances to combustibles as per installation instructions in this manual .........................................................
Check the operations of the air controls ................................................................................................................................
Conrm the venting system is secure and sealed .................................................................................................................
Conrm the stove starts and operates properly ....................................................................................................................
Check to ensure a CO alarm is installed as per local building codes and is functional ......................................................
Explain the safe operation, proper fuel usage, cleaning, and routine maintenance requirements .....................................
Declaration of Completion: As the qualied person responsible for the work described above, I conrm that the appliance
as associated work has been installed as per manufacturer’s instructions and following any applicable building and
installation codes.
Signed: _______________________________________ Print Name: ___________________________________ Date: _______________
Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE
4
© 2022 United States Stove Company
ASSEMBLY INSTRUCTIONS
FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050
1. Pull the factory installed wires out of the top of the
stove. There will be two wire harnesses, as shown.
2. Unpack the top mount controls and ensure that the
wiring harness shown is attached securely.
3. Connect the factory installed wiring harnesses to the
control panel as shown.
4. Secure the control panel to the top of the stove with
two sheet metal screws.
© 2022 United States Stove Company
5
INSTALLATION
SAFETY NOTICE
IF THIS STOVE IS NOT PROPERLY INSTALLED, A
HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF
FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS.
CONTACT YOUR LOCAL BUILDING OFFICIALS TO
OBTAIN A PERMIT AND INFORMATION ON ANY
ADDITIONAL INSTALLATION RESTRICTIONS OR
INSPECTION REQUIREMENTS IN YOUR AREA.
DO NOT PLACE CLOTHING OR OTHER FLAMMABLE
ITEMS ON OR NEAR THIS STOVE.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR ’FRESHEN UP’
A FIRE IN THIS STOVE. KEEP ALL SUCH LIQUIDS
WELL AWAY FROM THE STOVE WHILE IT IS IN USE.
THIS APPLIANCE IS A FREESTANDING HEATER.
IT IS NOT INTENDED TO BE ATTACHED TO ANY
TYPE OF DUCTING. IT IS NOT A FURNACE. DO NOT
CONNECT THIS UNIT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM. THIS APPLIANCE IS NOT
INTENDED FOR COMMERCIAL USE.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
YOUR STOVE REQUIRES PERIODIC MAINTENANCE
AND CLEANING (SEE ”MAINTENANCE”). FAILURE
TO MAINTAIN YOUR STOVE MAY LEAD TO
IMPROPER AND/OR UNSAFE OPERATION.
A POWER SURGE PROTECTOR IS REQUIRED. THIS
UNIT MUST BE PLUGGED INTO A 110 - 120V, 60
HZ GROUNDED ELECTRICAL OUTLET. DO NOT USE
AN ADAPTER PLUG OR SEVER THE GROUNDING
PLUG. DO NOT ROUTE THE ELECTRICAL CORD
UNDERNEATH, IN FRONT OF, OR OVER THE HEATER.
DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS
OR PINCH THE CORD UNDER FURNITURE.
CAUTION:
BURNING FUEL CREATES CARBON MONOXIDE AND
CAN BE HAZARDOUS TO YOUR HEALTH IF NOT
PROPERLY VENTED.
ATTENTION:
A WORKING SMOKE DETECTOR MUST BE
INSTALLED IN THE SAME ROOM AS THIS PRODUCT.
INSTALL A SMOKE DETECTOR ON EACH FLOOR OF
YOUR HOME; INCASE OF ACCIDENTAL FIRE FROM
ANY CAUSE IT CAN PROVIDE TIME FOR ESCAPE.
THE SMOKE DETECTOR MUST BE INSTALLED AT
LEAST 15 FEET (4,57 M) FROM THE APPLIANCE IN
ORDER TO PREVENT UNDUE TRIGGERING OF THE
DETECTOR WHEN RELOADING.
CAUTION:
USE OF OUTSIDE AIR IS NOT REQUIRED FOR THIS
UNIT.
DO NOT UNPLUG THE STOVE IF YOU SUSPECT A
MALFUNCTION. TURN THE ON/OFF SWITCH TO
”OFF’ AND CONTACT YOUR DEALER.
THE HEATER WILL NOT OPERATE DURING A POWER
OUTAGE. IF A POWER OUTAGE DOES OCCUR,
CHECK THE HEATER FOR SMOKE SPILLAGE AND
OPEN A WINDOW IF ANY SMOKE SPILLS INTO THE
ROOM.
NEVER BLOCK FREE AIRFLOW THROUGH THE OPEN
VENTS OF THE UNIT.
US Stove highly recommends your stove be installed by a
qualied NFI (US) or WETT (Canada) technician. To nd
the nearest qualied installer, go to:
https://ncertied.org,
https://www.wettinc.ca/
FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050
6
© 2022 United States Stove Company
INSTALLATION
INSTALLATION OPTIONS
Freestanding Unit - supported by pedestal/legs and
placed on a non-combustible oor surface in compliance
with clearance requirements for a freestanding stove
installation.
Alcove Unit - supported by pedestal/legs and placed
on a non-combustible oor surface in compliance with
clearance requirements for an alcove installation.
IMPROPER INSTALLATION
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty. The manufacturer will not be held responsible
for damage caused by the malfunction of a stove due to
improper venting or installation.
FLOOR PROTECTION
This heater must have a non-combustible oor protector
(ember protection) installed beneath it if the oor is of
combustible material. If a oor pad is used, it should
be UL listed or equal. The oor pad or non-combustible
surface should be large enough to cover at least the area
under the product and 6” (153 mm) beyond the front and
beyond each side of the fuel loading and ash removal
openings. Floor protection must extend under and 2” (51
mm) to each side of the chimney tee for an interior vertical
installation. Canadian Installations require a minimum of
18” [458 mm] beyond the front of the unit and 8” [204 mm]
beyond each side of the unit.
ASide to Stove U.S.A 6” 153 mm
CAN 8” 204 mm
B Front to Stove U.S.A 6” 153 mm
CAN 18” 458 mm
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home in accordance with the
clearances given below. For safety reasons, please
adhere to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be done
by means approved by a regulatory authority.
CSide Wall To Appliance 8” 204 mm
D Side Wall To Flue 3” 77 mm
E Back wall To Appliance 9.5” 242 mm
F Back wall To Flue 3” 77 mm
GWall To Corner Of Appliance 2” 51 mm
H Ceiling Height To Floor 60” 1524 mm
JCeiling Height To Appliance 27” 686 mm
© 2022 United States Stove Company
7
OUTSIDE AIR SUPPLY (OPTIONAL, UNLESS INSTALLING
IN A MOBILE HOME)
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home.
You can purchase the 69FAK through your heater dealer.
Installation instructions are supplied with the air intake kit.
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK, AWNING,
OR IN ANY SEMI ENCLOSED OR ROOFED AREA. DOING
SO MAY RESULT IN UNPREDICTABLE AIRFLOW AT THE
VENT CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE, AS
WELL AS, OTHER UNFORESEEABLE ISSUES.
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the oor.
Fresh Air
Intake
Exhaust
Pipe
WARNING! DO NOT INSTALL IN SLEEPING ROOM.
CAUTION! THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
WHEN INSTALLED IN A MOBILE HOME, THE STOVE
MUST BE GROUNDED DIRECTLY TO THE STEEL
CHASSIS AND BOLTED TO THE FLOOR.
In addition to the previously detailed installation
requirements, mobile home installations must meet the
following requirements:
This stove must be securely fastened to the oor of
the mobile home using two 1/4” lag bolts that are long
enough to go through both a hearth pad, if used, and the
oor of the home.
The heater must be electrically grounded to the steel
chassis of the mobile home with 8 GA copper wire using
a serrated or star washer to penetrate paint or protective
coating to ensure grounding.
Vent must be 3 or 4-inch “PLVent and must extend a
minimum or 36” (914 mm) above the roof line of the
mobile home and must be installed using a certied
ceiling re stop and rain cap.
When moving your mobile home, all exterior venting must
be removed while the mobile home is being relocated.
After relocation, all venting must be reinstalled and
securely fastened.
Outside Air is mandatory for mobile home installation.
See Outside Air Supply section and your dealer for
purchasing.
Check with your local building ocials as other codes
may apply.
VENTING REQUIREMENTS
WARNING:
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
DO NOT CONNECT THE PELLET VENT TO A VENT
SERVING ANY OTHER APPLIANCE OR STOVE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
The following installation guidelines must be followed
to ensure conformity with both the safety listing of this
stove and to local building codes. Do not use makeshift
methods or compromise in the installation.
IMPORTANT:
THIS UNIT IS EQUIPPED WITH A NEGATIVE DRAFT
SYSTEM THAT PULLS AIR THROUGH THE BURN POT
AND PUSHES THE EXHAUST OUT OF THE DWELLING.
IF THIS UNIT IS CONNECTED TO A FLUE SYSTEM
OTHER THAN THE WAY EXPLAINED IN THIS MANUAL,
IT WILL NOT FUNCTION PROPERLY.
MAXIMUM VENTING DISTANCE
Installation MUST include at least 3-feet of vertical pipe
outside the home. This will create some natural draft to
reduce the possibility of smoke or odor during appliance
shutdown and keep exhaust from causing a nuisance or
hazard by exposing people or shrubs to high temperatures.
The maximum recommend vertical venting height is 12-
feet for 3-inch type “PLvent. Total length of horizontal vent
must not exceed 4-feet. This could cause back pressure.
Use no more than 180 degrees of elbows (two 90-degree
elbows, or two 45-degree and one 90-degree elbow, etc.)
to maintain adequate draft.
INSTALLATION
8
© 2022 United States Stove Company
IMPORTANCE OF PROPER DRAFT
Draft is the force which moves air from the appliance up
through the chimney. The amount of draft in your chimney
depends on the length of the chimney, local geography,
nearby obstructions and other factors. Too much draft
may cause excessive temperatures in the appliance.
Inadequate draft may cause backpung into the room and
‘plugging’ of the chimney. Inadequate draft will cause the
appliance to leak smoke into the room through appliance
and chimney connector joints. An uncontrollable burn or
excessive temperature indicates excessive draft. Take into
account the chimney’s location to ensure it is not too close
to neighbours or in a valley which may cause unhealthy or
nuisance conditions.
PELLET VENT TYPE
A certied 3-inch or 4-inch type “PLpellet vent exhaust
system must be used for installation and attached to the
pipe connector provided on the back of the stove (use a
3-inch to 4-inch adapter for 4-inch pipe). The connection
at the back of the stove must be sealed using Hi-Temp
RTV. Use a 4-inch vent if the vent height is over 12-feet or
if the installation is over 2,500 feet above sea level. We
recommend the use of Simpson Dura-Vent® or Metal-
Fab® pipe (if you use other pipes, consult your local
building codes and/or building inspectors). Do not use
Type-B Gas Vent pipe or galvanized pipe with this unit. The
pellet vent pipe is designed to disassemble for cleaning
and should be checked several times during the burning
season. The pellet vent pipe is not furnished with the unit
and must be purchased separately.
PELLET VENT INSTALLATION
The installation must include a clean-out tee to enable
collection of y ash and to permit periodic cleaning of the
exhaust system. 90-degree elbows accumulate y ash
and soot thereby reducing exhaust ow and performance
of the stove. Each elbow or tee reduces draft potential by
30% to 50%. All joints in the vent system must be fastened
by at least 3 screws, and all joints must be sealed with Hi-
Temp RTV silicone sealant to be airtight. The area where
the vent pipe penetrates to the exterior of the home must
be sealed with silicone or other means to maintain the
vapor barrier between the exterior and the interior of the
home. Vent surfaces can get hot enough to cause burns if
touched by children. Noncombustible shielding or guards
may be required.
PELLET VENT TERMINATION
Do not terminate the vent in an enclosed or semi-enclosed
area, such as; carport, garage, attic, crawl space, under a
sun deck or porch, narrow walkway, or any other location
that can build up a concentration of fumes. Termination in
one of these areas can also lead to unpredictable pressure
situations with the appliance, and could result in improper
performance and/or malfunction. The termination
must exhaust above the outside air inlet elevation. The
termination must not be located where it will become
plugged by snow or other materials. Do not terminate the
venting into an existing steel or masonry chimney.
VENT TERMINATION CLEARANCES
A. Minimum 4-foot (1.22m) clearance below or beside
any door or window that opens.
B. Minimum 1-foot (0.3m) clearance above any door or
window that opens.
C. Minimum 3-foot (0.91m) clearance from any adjacent
building.
D. Minimum 7-foot (2.13m) clearance from any grade
when adjacent to public walkways.
E. Minimum 2-foot (0.61m) clearance above any grass,
plants, or other combustible materials.
F. Minimum 3-foot (0.91m) clearance from an forced air
intake of any appliance.
G. Minimum 2-foot (0.61m) clearance below eves or
overhang.
H. Minimum 1-foot (0.3m) clearance horizontally from
combustible wall.
INSTALLATION
© 2022 United States Stove Company
9
I. Must be a minimum of 3 foot (0.91m) above the roof
and 2 foot (0.61m) above the highest point or the roof
within 10 feet (3.05m).
Determining where to install your new pellet stove heater.
To get the most ecient use of re-circulated heat, you
should consider a room that is centrally located within
your home. Choose a room that is large and open. It is
Extremely Important to maintain proper clearances from
any combustible surfaces or materials in the room where
your heater will be located. You can nd proper clearance
measurements in this manual and on the rating label of
your pellet stove. The pellet stove can be vented through an
exterior wall or into an existing masonry or metal chimney
if “PL vent pipe is used throughout existing chimney.
Venting can pass through the ceiling and roof if approved
pipe is used. Where passage through a wall, or partition of
combustible construction is desired, the installation must
conform to CAN/CSA-B365.
WARNING:
DO NOT OBTAIN COMBUSTION AIR FROM THE
ATTIC, GARAGE OR ANY OTHER UNVENTILATED
AREA. YOU MAY OBTAIN COMBUSTION AIR FROM
A VENTILATED CRAWL SPACE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER HEATER, FURNACE OR
APPLIANCE.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
ONLY USE APPROVED MATERIAL FOR
INSTALLATION, FAILURE TO DO SO MAY RESULT
IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN
DEATH.
This appliance is certied for use with listed 3 inch or 4 inch
“PL” pellet venting products. The use of other components
other than stated herein could cause bodily harm, heater
damage, and void your warranty.
HORIZONTAL EXHAUST VENT INSTALLATION
1. Locate your pellet stove in a location which meets the
requirements of this manual, but in an area where it
does not interfere with the house framing, wiring, etc.
2. Install a non-combustible hearth pad underneath the
pellet stove. This pad should extend at least 6” (152
mm) in front of the unit.
3. Place the pellet stove approximately 15” (381 mm)
away from the interior wall.Locate the center of the
exhaust pipe of your unit. This point should then be
extended to the interior wall of your house. Once you
have located the center point, on the interior wall, cut a
7” (175 mm) diameter hole through the wall.
4. The next step is to install the wall thimble, refer to the
instructions which come with the wall thimble for this
step.
5. Install the appropriate length of exhaust vent pipe
into the wall thimble. See steps 11 and 12 when
determining the correct length of exhaust vent to use.
6. Outside Fresh Air is Mandatory when installing
this pellet stove room heater in airtight homes and
mobile homes. Be sure that the outside air vent
has an approved cap on it to prevent rodents from
entering. Be sure to install in location that won’t
become blocked with snow, etc.
7. Connect the exhaust vent pipe to the exhaust outlet of
your pellet stove.
8. Secure all vent joint connections with 3 screws.
Seal the exhaust vent joint connections with high
temperature silicone sealant.
9. Push the unit straight back to the interior wall,
being sure to maintain the minimum clearances to
combustibles 2” (51 mm) to the back of the unit. Seal
the annular space of the wall thimble and around the
vent pipe with high temperature silicone sealant.
10. The exhaust vent pipe must extend at least 12” (300
mm) out past the exterior wall. Seal the annular space
of the wall thimble and around the vent pipe with high
temperature silicone sealant.
11. Install an approved horizontal termination cap or if
necessary install a 90° elbow and appropriate length
of vertical venting. An approved vertical vent cap is
recommended.
INSTALLATION
10
© 2022 United States Stove Company
THROUGH THE WALL INSTALLATION
(RECOMMENDED INSTALLATION)
TYPICAL THROUGH THE
WALL INSTALLATION
Canadian installations must conform to CAN/CSA-B365.
To vent the unit through the wall, connect the pipe adapter
to the exhaust motor adapter. If the exhaust adapter
is at least 18” (457 mm) above ground level, a straight
section of pellet vent pipe can be used through the wall.
Your heater dealer should be able to provide you with a
kit that will handle most of this installation, which will
include a wall thimble that will allow the proper clearance
through a combustible wall. Once outside the structure,
a 3” (76 mm) clearance should be maintained from the
outside wall and a clean out tee should be placed on the
pipe with a 90-degree turn away from the house. At this
point, a 3ft (0.91m) (minimum) section of pipe should be
added with a horizontal cap, which would complete the
installation. A support bracket should be placed just below
the termination cap or one every 4ft (1.22m) to make the
system more stable. If you live in an area that has heavy
snowfall, it is recommended that the installation be taller
than 3ft (0.91m) to get above the snowdrift line. This same
installation can be used if your heater is below ground level
by simply adding the clean-out section and vertical pipe
inside until ground level is reached. With this installation
you have to be aware of the snowdrift line, dead grass, and
leaves. We recommend a 3ft (0.91m) minimum vertical
rise on the inside or outside of the house. The “through
the wall” installation is the least expensive and simplest
installation. Never terminate the end vent under a deck, in
an alcove, under a window, or between two windows. We
recommend Simpson Dura-Vent® or Metal-Fab® kits.
INSTALLATION
© 2022 United States Stove Company
11
INSTALLATION
THROUGH THE ROOF/CEILING
INSTALLATION
When venting the heater through the ceiling, the pipe
is connected the same as through the wall, except the
clean-out tee is always on the inside of the house, and
a 3” (76 mm) adapter is added before the clean-out tee.
You must use the proper ceiling support anges and
roof ashing (supplied by the pipe manufacturer; follow
the pipe manufacturer’s directions). It is important to
note that if your vertical run of pipe is more than 12ft
(3.7m), the pellet vent pipe size should be increased to
4” (102 mm) in diameter.
Do not exceed more than 4ft (1.22m) of pipe on a
horizontal run and use as few elbows as possible. If an
offset is required, it is better to install 45-degree elbows
rather than 90-degree elbows.Venting your pellet stove
into an existing Class A 6” chimney System
1.
IMPORTANT:
If you are installing your pellet stove as a replacement
to an existing wood stove, you can install your pellet
stove using the existing class A 6” venting system.
You must have the existing chimney system
cleanedand/ or inspected by a qualied chimney
sweep before proceeding with the installation of your
pellet stove.
2. To the right is an example of an installation using part
number 860001, 3-6” transition into 6” connector pipe.
the illustration is only an example. Please conform
to any local building codes or regulations having
jurisdiction before you have a qualied installer
proceed with this installation.
12
© 2022 United States Stove Company
NEVER OPERATE THIS PRODUCT WHILE UNATTENDED
OPERATION INSTRUCTIONS
PANEL / REMOTE CONTROLS
The operation of this appliance can be controlled from
the panel located on the side of the stove and/or by the
remote control. The control functions are as follows:
A. On/Off Switch
When pushed, the stove will automatically ignite. No
other re starter is necessary. The igniter will stay on
for at least 10 and up to 12 minutes, depending on
when Proof of Fire is reached. The re should start in
approximately 5 minutes.
After pushing the “On/Off” button, the auger motor is on
for 3.5 minutes, off for 1 minute. During the remainder
of the start-up period, the auger motor operates on the
heat range “1” setting.
During start up the heat level advance (Up and Down keys)
will change the heat range indicator level accordingly,
but there is no change in the stoves operating conditions
until start-up is completed.
During start-up ignition must occur within 12 minutes or
the stove will error out and show E3.
During the start-up phase, the Mode key does not
function.
B. Heat Range Arrow Buttons
These buttons when pushed will set the pellet feed
rate, hence the heat output or heat range of your stove.
When using the hand-held remote this function can be
performed with the “Up/Down” buttons.
The levels of heat output will incrementally change on
the bar graph starting from heat range “1” to heat range
“5”.
C. °C / °F Button
The °C / °F button changes the two digit display from
degrees Celsius to degrees Fahrenheit.
D. MODE (M/T) BUTTON
The Mode of the stove can be switched between manual
and controlled with a Thermostat. Separate LEDs to
the left of the two digit display indicate the mode of
operation Manual or T-Stat. The stove has to be in
normal operation to be switched from Manual to T-Stat
mode.
Manual mode operates according to the 5 set levels of
feed on the bar graph from heat range “1” to heat range
“5”.
T-Stat mode works as follows:
The stove has a built in Thermostat into the controls
of the appliance. The temperature sensor for the T-Stat
is located on the back of the stove behind the display
board.
Once the stove has gone into run mode the stove can be
switch into T-Stat mode.
The Up and Down Level / Temp Arrow buttons are used
to change the desired set-point temperature. Once the
desired temperature is reached the two digit display
will ash for four seconds and reset to the actual room
temperature.
Once the stove reaches within 3°F of the desired
temperature set point, it returns to the heat range that
the stove was set on before it was switched to T-Stat
mode (if the stove was running on heat range “5” when
switched to T-stat mode when it gets within 3°F of the
set point it will return to heat range “5”).
Once the stove reaches the desired set-point, the stove
will drop to heat range “1”.
When room temperature drops below desired set-point
the stove will ramp back up until it reaches the desired
temperature.
NOTE:
Operation range of this
remote is within 16-1/12 ft.
of the appliance.
© 2022 United States Stove Company
13
OPERATION INSTRUCTIONS
PROPER FUEL
ATTENTION:
THIS APPLIANCE IS DESIGNED FOR THE USE
OF PELLETIZED FUEL THAT MEET OR EXCEED
THE STANDARD SET BY THE PELLET FUEL
INSTITUTE (PFI).
Your pellet stove is designed to burn premium hardwood
pellets that comply with the Pellet Fuels Institute (PFI)
standard (minimum of 40 lbs density per cubic ft, 1/4” to
5/16” diameter, length no greater than 1.5”, not less than
8,200 BTU/lb, moisture under 8% by weight, ash under 1%
by weight, and salt under 300 parts per million). Pellets
that are soft, contain excessive amounts of loose sawdust,
have been, or are wet, will result in reduced performance.
Store your pellets in a dry place. DO NOT store the fuel
within the installation clearances of the unit or within the
space required for refuelling and ash removal. Doing so
could result in a house re. Do not over re or use volatile
fuels or combustibles, doing so may cause a personal and
property damage hazards.
THIS STOVE IS APPROVED FOR BURNING PELLETIZED
WOOD FUEL ONLY! Factory-approved pellets are those
1/4” or 5/16” in diameter and not over 1” long. Longer or
thicker pellets sometimes bridge the auger ights, which
prevents proper pellet feed. Burning wood in forms other
than pellets is not permitted. It will violate the building
codes for which the stove has been approved and will void
all warranties. The design incorporates automatic feed of
the pellet fuel into the re at a carefully prescribed rate. Any
additional fuel introduced by hand will not increase heat
output but may seriously impair the stoves performance
by generating considerable smoke. Do not burn wet
pellets. The stoves performance depends heavily on the
quality of your pellet fuel. Avoid pellet brands that display
these characteristics:
Excess Fines – “Fines” is a term describing crushed
pellets or loose material that looks like sawdust or sand.
Pellets can be screened before being placed in hopper
to remove most nes.
Binders – Some pellets are produced with materials to
hold the together, or “bind” them.
High ash content – Poor quality pellets will often create
smoke and dirty glass. They will create a need for more
frequent maintenance. You will have to empty the burn
pot plus vacuum the entire system more often. Poor
quality pellets could damage the auger. We cannot
accept responsibility for damage due to poor quality
pellet.
This heater is designed to burn only PFI Premium grade
pellets. DO NOT BURN:
1. Garbage;
2. Lawn clippings or yard waste;
3. Materials containing rubber, including tires;
4. Materials containing plastic;
5. Waste petroleum products, paints or paint thinners, or
asphalt products;
6. Materials containing asbestos;
7. Construction or demolition debris;
8. Railroad ties or pressure-treated wood;
9. Manure or animal remains;
10. Salt water driftwood or other previously salt water
saturated materials;
11. Unseasoned wood; or
12. Paper products, cardboard, plywood, or particleboard.
The prohibition against burning these materials does
not prohibit the use of re starters made from paper,
cardboard, saw dust, wax and similar substances
for the purpose of starting a re in an affected wood
heater.
Burning these materials may result in release of toxic
fumes or render the heater ineffective and cause smoke.
CAUTION:
KEEP FOREIGN OBJECTS OUT OF THE HOPPER.
THE MOVING PARTS OF THIS STOVE ARE
PROPELLED BY HIGH TORQUE ELECTRIC
MOTORS. KEEP ALL BODY PARTS AWAY FROM
THE AUGER WHILE THE STOVE IS PLUGGED INTO
AN ELECTRICAL OUTLET. THESE MOVING PARTS
MAY BEGIN TO MOVE AT ANY TIME WHILE THE
STOVE IS PLUGGED IN.
PRE-START-UP CHECK
Remove burn pot, making sure it is clean and none of the
air holes are plugged. Clean the rebox, and then reinstall
burn pot. Clean door glass if necessary (a dry cloth or
paper towel is usually sucient). Never use abrasive
cleaners on the glass or door. Check fuel in the hopper,
and rell if necessary.
BUILDING A FIRE
Never use a grate or other means of supporting the fuel.
Use only the burn pot supplied with this heater. Hopper lid
must be closed in order for the unit to feed pellets. During
the start-up period:
14
© 2022 United States Stove Company
Make sure the burn pot is free of pellets.
DO NOT open the viewing door.
DO NOT add pellets to the burn pot by hand.
NOTE: During the rst few res, your stove will emit an odor
as the high-temperature paint cures or becomes seasoned
to the metal. Maintaining smaller res will minimize this.
Avoid placing items on the stovetop during this period
because the paint could be affected. Attempts to achieve
heat output rates that exceed heater design specications
can result in permanent damage to the heater.
AUTOMATIC IGNITOR
1. Fill hopper and clean burn pot.
2. Press the “On/Off” button. Make sure the green light
comes on.
3. Adjust the feed rate to the desired setting by pressing
the “Heat Level Advance” button.
If the re doesn’t start in 12 minutes, press “On/Off”, wait
a few minutes, clear the burn pot, and start the procedure
again.
OPTIMAL OPERATION
This pellet stove has been certied by the US EPA to
meet strict 2020 guidelines. To insure this unit produces
the optimal minimal emissions, it is critical to follow the
following guidelines. To achieve a “high burn”, your stove
should be set on setting 5 with the damper fully open.
To achieve a “medium burn”, your stove should be set
on setting 3 with the damper closed 50%. To achieve a
“low burn”, your stove should be set on setting 1 with the
damper fully closed. Setting 4 will give you a medium high
burn and setting 2 will give you a medium low burn. If the
door is opened while the stove is in operation it must be
closed within 30 seconds or the stove will shut down. If
the stove shuts down push the “On/Off” button to re-start
your stove. The stove will have to fully shut down and turn
off before you will be able to restart the stove
OPENING DOOR
CAUTION:
DO NOT OPERATE YOUR STOVE WITH THE
VIEWING DOOR OPEN. THE AUGER WILL NOT
FEED PELLETS UNDER THESE CIRCUMSTANCES
AND A SAFETY CONCERN MAY ARISE FROM
SPARKS OR FUMES ENTERING THE ROOM.
THE DOOR MUST BE CLOSED AND SEALED
DURING OPERATION.
If the door is opened while the stove is in operation it must
be closed within 30 seconds or the stove will shut down. If
the stove shuts down push the “On/Off” button to re-start
your stove. The stove will have to fully shut down and turn
off before you will be able to restart the stove.
ROOM AIR FAN
When starting your stove the Room Air Fan will not come
on until the stoves heat exchanger warms up. This usually
takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The re goes out and the auger motor and blowers will run
until the stove cools. This will take 30 minutes or longer
depending on the heat remaining in the appliance. After
the stove components stop running all lights on the display
will go out and the two digit display will begin ashing “E3”
OPERATION INSTRUCTIONS
© 2022 United States Stove Company
15
REFUELING
CAUTION:
THE HOPPER AND STOVE TOP WILL BE HOT
DURING OPERATION; THEREFORE, YOU
SHOULD ALWAYS USE SOME TYPE OF HAND
PROTECTION WHEN REFUELING YOUR STOVE.
DO NOT TOUCH THE HOT SURFACES OF THE
STOVE. EDUCATE ALL CHILDREN ON THE
DANGERS OF A HIGH-TEMPERATURE STOVE.
YOUNG CHILDREN SHOULD BE SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS THE
STOVE.
NEVER PLACE YOUR HAND NEAR THE AUGER
WHILE THE STOVE IS IN OPERATION.
WE RECOMMEND THAT YOU NOT LET THE
HOPPER DROP BELOW 1/4 FULL.
WARNING:
KEEP HOPPER LID CLOSED AT ALL TIMES
EXCEPT WHEN REFILLING.
DO NOT OVERFILL HOPPER.
TAMPER WARNING
This wood heater has a manufacturer-set minimum low
burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood heater in a manner inconsistent with operating
instructions in this manual.
SHUTDOWN PROCEDURE
WARNING:
NEVER SHUT DOWN THIS UNIT BY UNPLUGGING
IT FROM THE POWER SOURCE.
Turning your stove off is a matter of pressing the “POWER”
button on the display board. The green light will turn back
to red when the “POWER” button is pushed. The auger
motor will stop, and the blowers will continue to operate
until the internal rebox temperatures have fallen to a
preset level.
1. Your stove is equipped with a high temperature snap
disc. This unit has a manual reset snap disc. This
safety switch has two functions.
A. To recognize an overheat situation in the stove and
shut down the fuel feed or auger system.
B. In case of a malfunctioning convection blower, the
high-temperature snap disc will automatically shut
down the auger, preventing the stove from overheating.
NOTE: On some units, once tripped, like a circuit breaker,
the reset button will have to be pushed before restarting
your stove. On other units the snap disc has no reset
button and will reset itself once the stove has cooled. The
manufacturer recommends that you call your dealer if this
occurs as this may indicate a more serious problem. A
service call may be required.
2. If the combustion blower fails, an air pressure switch
will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds
during operation will cause enough pressure change to
activate the air switch, shutting the fuel feed off. The stove
will shut down and show “E2” on the two digit display. The
stove has to fully shut down before restarting.
INTERIOR CHAMBERS
Burn Pot - Periodically remove and clean the burn pot
and the area inside the burn pot housing. In particular,
it is advisable to clean out the holes in the burn pot to
remove any build up that may prevent air from moving
through the burn pot freely.
Heat Exchanger - There are three panels in the back of
the rebox that need to be removed in order to clean the
y ash out of the heat exchanger.
a. Open the door and remove the burnpot.
b. Use the tab located at the top of the center panel to lift
the panel up and out of the unit.
OPERATION INSTRUCTIONS
16
© 2022 United States Stove Company
c. Lift the left and right panel up and out of the unit.
Left
Panel Right
Panel
d. Remove y ash.
It is possible that creosote may accumulate in the exhaust
fan therefore, this must be brushed clean. The exhaust fan
can be found behind the left side panel (facing the front
of the heater), the circulation fan can be found behind the
right side panel. To access the igniter, remove the air inlet
tube and cover (2 screws). The auger motor is located in
the center rear of the unit. Note: When cleaning, take care
not to damage the fan blades.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac is
designed for ash removal. Some regular vacuum cleaner
(i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
WARNING:
FAILURE TO PROPERLY MAINTENANCE THE CLEAN
OUTS WILL RESULT IN POOR PERFORMANCE OF
THIS STOVE.
OPERATION INSTRUCTIONS
© 2022 United States Stove Company
17
NEVER OPERATE THIS PRODUCT WHILE UNATTENDED
MAINTENANCE
CAUTION:
FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS
INDICATED CAN RESULT IN POOR PERFORMANCE,
SAFETY HAZARDS, FIRE, AND EVEN DEATH.
NEVER PERFORM ANY INSPECTIONS, CLEANING,
OR MAINTENANCE ON A HOT STOVE.
DISCONNECT THE POWER CORD BEFORE
PERFORMING ANY MAINTENANCE! NOTE:
TURNING THE ON/OFF SWITCH TO ”OFF” DOES NOT
DISCONNECT ALL POWER TO THE ELECTRICAL
COMPONENTS OF THE STOVE.
DO NOT OPERATE STOVE WITH BROKEN GLASS,
LEAKAGE OF FLUE GAS MAY RESULT.
ATTEMPTS TO ACHIEVE HEAT OUTPUT RATES
THAT EXCEED HEATER DESIGN SPECIFICATIONS
CAN RESULT IN PERMANENT DAMAGE TO THE
HEATER.
CREOSOTE FORMATION, INSPECTION, &
REMOVAL
CAUTION:
THE EXHAUST SYSTEM SHOULD BE CHECKED
MONTHLY DURING THE BURNING SEASON FOR ANY
BUILD-UP OF SOOT OR CREOSOTE.
When any wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture
to form creosote. The creosote vapors condense in the
relatively cool chimney ue or a newly started re or
from a slow-burning re. As a result, creosote residue
accumulates on the ue lining. When ignited, this creosote
makes an extremely hot re, which may damage the
chimney or even destroy the house. Despite their high
eciency, pellet stoves can accumulate creosote under
certain conditions. The chimney connector and chimney
should be inspected by a qualied person annually or per
ton of pellets to determine if a creosote or y ash build-up
has occurred. If creosote has accumulated, it should be
removed to reduce the risk of a chimney re. Inspect the
system at the stove connection and at the chimney top.
Cooler surfaces tend to build creosote deposits quicker, so
it is important to check the chimney from the top as well as
from the bottom. The creosote should be removed with a
brush specically designed for the type of chimney in use.
A qualied chimney sweep can perform this service. It is
also recommended that before each heating season the
entire system be professionally inspected, cleaned and, if
necessary, repaired. To clean the chimney, disconnect the
vent from the stove.
FLY ASH
This accumulates in the horizontal portion of an exhaust
run. Though non-combustible, it may impede the normal
exhaust ow. It should therefore be periodically removed.
ASH REMOVAL & DISPOSAL
CAUTION:
ALLOW THE STOVE TO COOL BEFORE PERFORMING
ANY MAINTENANCE OR CLEANING. ASHES MUST BE
DISPOSED IN A METAL CONTAINER WITH A TIGHT
FITTING LID. THE CLOSED CONTAINER OF ASHES
SHOULD BE PLACED ON A NON-COMBUSTIBLE
SURFACE OR ON THE GROUND, WELL AWAY FROM
ALL COMBUSTIBLE MATERIALS, PENDING FINAL
DISPOSAL.
Remove the ashes periodically to avoid unnecessary ash
build up. Remove ashes when unit has cooled. Ashes
should be placed in a metal container with a tight tting
lid. The closed container of ashes should be placed
on a noncombustible oor or on the ground, well away
from all combustible materials, pending nal disposal. If
the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed
container until all embers have been thoroughly cooled.
The container shall not be used for other trash or waste
disposal. If combined with combustible substances, ashes
and embers may ignite.
SMOKE & CO MONITORS
Burning wood naturally produces smoke and carbon
monoxide(CO) emissions. CO is a poisonous gas
when exposed to elevated concentrations for extended
periods of time. While the modern combustion systems
in heaters drastically reduce the amount of CO emitted
out the chimney, exposure to the gases in closed or
conned areas can be dangerous. Make sure you stove
gaskets and chimney joints are in good working order
and sealing properly to ensure unintended exposure. It is
recommended that you use both smoke and CO monitors
in areas having the potential to generate CO.
CHECK & CLEAN THE HOPPER
Check the hopper periodically to determine if there is any
sawdust (nes) that is building up in the feed system or
pellets that are sticking to the hopper surface. Clean as
needed.
DOOR & GLASS GASKETS
Inspect the main door and glass window gaskets
periodically. The main door may need to be removed to
have frayed, broken, or compacted gaskets replaced by
your authorized dealer. This unit’s door uses a 1” diameter
rope gasket.
18
© 2022 United States Stove Company
MAINTENANCE
BLOWER MOTORS
Clean the air holes on the motors of both the exhaust and
distribution blowers annually. Remove the exhaust blower
from the exhaust duct and clean out the internal fan blades
as part of your fall start-up. If you have indoor pets your
power motors should be inspected monthly to make sure
they are free of animal hair build up. Animal hair build up
in blowers can result in poor performance or unforeseen
safety hazards.
PAINTED SURFACES
Painted surfaces may be wiped down with a damp cloth. If
scratches appear, or you wish to renew your paint, contact
your authorized dealer to obtain a can of suitable high-
temperature paint.
GLASS
We recommend using a high-quality glass cleaner. Should
a buildup of creosote or carbon accumulate, you may wish
to use 000 steel wool and water to clean the glass. DO
NOT use abrasive cleaners. DO NOT perform the cleaning
while the glass is HOT. Do not attempt to operate the unit
with broken glass. Replacement glass may be purchased
from your U.S. Stove dealer. If the glass is broken, follow
these removal procedures:
1. Once the heater has cooled, remove the door from the
heater.
2. Remove the rope gasket from the door followed by the
nuts holding the glass retainer in place.
3. While wearing gloves, carefully remove any loose
pieces of glass from the door frame.
4. Replace the glass and gasket, making sure the gasket
runs the full perimeter of the glass edge.
5. Re-install the retainer and eight nuts and rope gasket
using high-temperature silicone to adhere the gasket
to the door.
6. Never use substitute materials for the glass.
DO NOT abuse the door glass by striking, slamming, or
similar trauma. Do not operate the stove with the glass
removed, cracked, or broken.
FALL START UP
Prior to starting the rst re of the heating season, check
the outside area around the exhaust and air intake systems
for obstructions. Clean and remove any y ash from the
exhaust venting system. Clean any screens on the exhaust
system and on the outside air intake pipe. Turn all of the
controls on and make sure that they are working properly.
This is also a good time to give the entire stove a good
cleaning throughout.
SPRING SHUTDOWN
After the last burn in the spring, remove any remaining
pellets from the hopper and the auger feed system. Scoop
out the pellets and then run the auger until the hopper
is empty and pellets stop owing (this can be done by
pressing the “ON” button with the viewing door open).
Vacuum out the hopper. Thoroughly clean the burn pot,
and rebox. It may be desirable to spray the inside of the
cleaned hopper with an aerosol silicone spray if your stove
is in a high humidity area. The exhaust system should be
thoroughly cleaned.
MAINTENANCE SCHEDULE
Use the following as a guide under average use conditions.
Gaskets around door and door glass should be inspected
and repaired or replaced when necessary.
Daily Weekly Monthly or
as needed
Burn Pot Stirred Empty
Combustion
Chamber Brushed
Ashes Check Empty
Interior Chambers Vacuumed
Combustion
Blower Blades
Vacuumed /
Brushed
Convection Blower
Impeller
Vacuumed /
Brushed
Vent System Cleaned
Gaskets Inspected
Glass Wiped Cleaned
Hopper (end of
season)
Empty &
Vacuumed
© 2022 United States Stove Company
19
TROUBLESHOOTING GUIDE
When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by
enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors: 1) poor
fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You can usually
solve those problems related to 1 and 2. Customer service can solve problems relating to 3, 4 and 5. Refer to diagrams
in the “Repair Parts” section to help locate indicated parts. For the sake of troubleshooting and using this guide to
assist you, you should look at your heat level setting to see which light is flashing.
Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” does
not disconnect all power to the electrical components of the stove.
Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All other
work should be done by a trained technician.
Display is Flashing “E1”
Possible Causes Possible Remedies: (Unplug stove first when possible)
The stove is consuming too much fuel
Adjust the fuel adjuster slide (see the “How To Adjust The Fuel
Adjuster” section of this manual). Close the slide about 1/4” after
your stove cools down. Restart your stove. If your display shows
E1 again, close the slide another 1/4” and restart.
The convection blower is overheating and
tripping the internal temperature shuto.
Clean any dust o of the windings and fan blade. If oiling the
blower does not help, the blower may be bad.
The stove is being left on the highest setting for
extended periods of time.
If operating the heater on the highest heat setting, the room
temperature could increase enough and lead to potential
overheating situations. If this happens try operating at a lower
heat setting.
Fuel other than wood pellets is being burned in
the stove.
This pellet stove is designed and tested to use wood pellets.
Check for signs of fuel other than wood pellets. No other types
of fuel have been approved for this pellet stove. If there are signs
of other types of fuel being used, stop using them immediately.
Power surge or brown out situation.
A power surge, spike, or voltage drop could cause the high limit
switch to trip. Check to see if a surge protector is being used on
the stove. If not, recommend one to the customer.
High Limit Switch is malfunctioning. If the other items check out OK, replace the high limit switch.
ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT
WITH OPERATING INSTRUCTIONS IN THIS MANUAL.
20
© 2022 United States Stove Company
TROUBLESHOOTING GUIDE
Display is Flashing “E2”
Possible Causes Possible Remedies: (Unplug stove first when possible)
Airflow switch hose or stove attachment pipes
for hose are blocked.
Unhook air hose from the air switch and blow through it. If air
flows freely, the hose and tube are fine. If air will not flow throw
the hose, use a wire coat hanger to clear the blockage.
The air inlet, burnpot, interior combustion air
chambers, combustion blower, or exhaust pipe
are blocked with ash or foreign material.
Follow all cleaning procedures in the maintenance section of the
owners manual.
The firebox is not properly sealed. Make sure the door is closed and that the gasket is in good shape.
Vent pipe is incorrectly installed. Check to make sure vent pipe installation meets criteria in
owners manual.
The airflow switch wire connections are bad. Check the connectors that attach the gray wires to the air switch.
Combustion blower failure.
With the stove on, check to see if the combustion blower is
running. If it is not, you will need to check for power going to the
combustion blower. It should be a full current. If there is power,
the blower is bad. If there is not, make sure the control board is
sending power to the air switch.
Control board not sending power to combustion
blower.
If there is no current going to the combustion blower, check all
wire connections. If all wires are properly connected, you have a
bad control board.
Control board not sending power to air switch. There should be a 5-volt current (approximately) going to the air
switch after the stove has been on for 30 seconds.
Air switch has failed.
To test the air switch, you will need to disconnect the air hose
from the body of the stove. With the other end still attached
to the air switch, very gently suck on the loose end of the hose
(you may want to remove the hose entirely o the stove and the
air switch first and make sure it is clear). If you hear a click, the
air switch is working. BE CAREFUL TOO MUCH VACUUM CAN
DAMAGE THE AIR SWITCH.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

United States Stove Company VG5717 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire

dans d''autres langues