A. MOUNTING
GENERAL
This luminaire is designed for outdoor lighting
applications, and should not be used in areas of limited
ventilation, or in high ambient temperature enclosures.
For optimum performance, it should be installed and
maintained according to the following recommendations.
UNPACKING
This luminaire has been properly packed so that no parts
should have been damaged during transit. Inspect to
confirm.
INSTALLATION
The refractor must be removed to access two bolts (on
each side of the reflector) which secures front housing to
back plate. Removal of the front housing allows access for
mounting and wiring.
NOTE: For units marked W25C having socket
mounted in front housing, plug wire assembly
located in center top of back plate must be un-
plugged while removing front housing.
A gasket is provided with the unit to be used when
mounting over an outlet box, and should be installed
between rear of back plate and the mounting surface. If
additional sealing is desired, caulk back of housing with
generic non-hardening sealant (not provided) across the
top and down both sides.
Outlet Box Mounting: The luminaire can be mounted to
a suitable surface-mounted outlet box (3'’ or 4'’ octagon, or
2'’x4'’ rectangular). The back plate may be attached to the
outlet box with two 10-24 screws (not provided), approxi-
mately ‘’ long. An alternate method of mounting the back
plate over a surface-mounted outlet box is to position back
plate over box and mount with two 3/8'’ bolts (not
provided) through the knock-out holes provided in the back
plate (see figure 2). Wire the unit (see Wiring). Reattach
the front housing/reflector over the back plate. For W25C
having socket mounted in front housing, plug wire assembly
must be re-connected as front housing is installed.
Figure 1
Figure 2
Tube protecteur d'alimentation :
Note : Certains modèles peuvent ne pas permettre ce
montage ou nécessiter du câblage spécial haute
température. Reportez-vous aux étiquettes sur la
plaque arrière pour les instructions.
Des bouchons défonçables sont disponibles pour permettre le
montage de la plaque arrière sur des surfaces verticales avec deux
boulons de 3/8 po (non fournis). Le tube protecteur d'alimentation
est positionné sur les supports de chaque côté de la plaque arrière, et
fixé avec les colliers et vis fournis (voir figure 2). Le tube peut aussi
être fixé au mur d'un côté ou de l'autre du luminaire avec des brides
pour tuyau (non fournies). Faites les raccordements (voir la section
CÂBLAGE). Repoussez les surfaces de passage de chaque côté du
boîtier avant en utilisant des pinces, en les tordant vers l'intérieur.
Rattachez le boîtier avant et réflecteur sur la plaque arrière. Pour le
modèle W25C qui a la douille montée sur le boîtier avant, il faut
rebrancher le bloc bornier d'alimentation amovible au remontage.
Mettez l'ampoule en place (voir la section INSTALLATION
D'AMPOULE) et remontez le réfracteur ou l'assemblage optique à
écran.
NOTE : Ne mettez pas une pression excessive du joint sur les
lentilles acryliques car elles pourraient alors se fissurer
autour des trous de vissage.
B. CÂBLAGE
Établissez toutes les liaisons électriques en conformité avec
la norme NEC ou vos réglementations locales en vigueur.
Vérifiez que la tension secteur disponible est compatible avec
celle de l’appareil indiquée sur sa plaque d’identification.
Le câblage par le client arrive soit par le trou central de la
plaque arrière, soit par les passages pour tube protecteur
d'alimentation sur les côtés du boîtier avant. Dans les deux
cas un accès facile à la zone de câblage (voir figure 2) est
fourni pour les connexions électriques.
Faites passer les fils d'arrivée d'alimentation dans les passe-
fils fournis et gardez au moins un écartement de 13 mm par
rapport au ballast et au réflecteur.
NOTE : Connectez l'arrivée de masse sur la vis de terre
(marquée <<gnd>>) de la plaque arrière.
N'enlevez pas les bornes isolantes des fils non nécessaires
pour la connexion de tension requise.
MONO-TENSION
Tous les ballasts pour les modèles mono-tension sont précâblés de
sorte que l’usager n’ait qu’à relier les fils conducteurs
d’alimentation.
MULTI-TENSION – (120/208/240/277 volts)
Connectez la sortie du ballast ayant la borne isolée sur la borne de tension
voulue comme indiqué sur la plaque d’identification sur le ballast.
MULTI-PUISSANCE
Des ballasts sont disponibles pour diverses combinaisons de
puissances. Reportez-vous aux instructions de câblage sur
l'étiquette de câblage située à l'intérieur du luminaire.
Pour terminer l'installation reportez-vous à MONTAGE.
INSTALLATION D'AMPOULE
35-201578-4A (7/00)
N’utilisez que le type d’ampoules spécifié sur la plaque
d’identification. Suivez les recommandations et restrictions des
fabricants d’ampoules, en particulier pour le type de ballast, la position
d’utilisation, etc.
Serrage d’ampoule- modèle à culot Mogul : l’ampoule doit être
mise en place de façon sûre, par un serrage NEMA-EEI spécifié au
couple de 35 pouces-livres, qui s’effectue le plus aisément par un
serrage manuel ferme. Le vissage doit être suffisant pour
complètement abaisser et charger le contact central de la douille.
Serrage d’ampoule- modèle à culot moyen : L’ampoule doit être
vissée en douceur assez loin pour enfoncer le contact central de sa
douille.
ENTRETIEN ET NETTOYAGE
Il faudra à l’occasion nettoyer le réfracteur pour maintenir son
apparence et le niveau d’éclairage. La fréquence de nettoyage
dépendra de la densité de poussière ambiante et du niveau minimum
d’éclairage désiré. Le réfracteur et le boîtier seront lavés avec une
solution d’eau chaude et de détergent ménager léger, puis rincés à
l’eau claire et séchés par essuyage. Si l’ensemble optique interne
devenait sale, nettoyez le réflecteur et l’intérieur du réfracteur de la
même façon. Remplacez le joint statique s’il est endommagé.
La puissance lumineuse générée par le luminaire est également
dépendante de l’âge de son ampoule. Pour les applications où le
niveau lumineux est critique, il peut être souhaitable de remplacer les
ampoules avant qu’elles ne grillent. Le fabricant d'ampoules peut
fournir des données sur la baisse de luminosité en fonction du
vieillissement.
WARNING
Risk of electric shock
Turn power off before servicing
see instructions
WARNING
Risk of fire
Use supply wire specified on
nameplate
CAUTION
Unit will fall if not installed properly
Follow installation instructions
ATTENTION
Risque de brûlure
Laissez le bloc d’ampoule refroidir
avant d’y toucher
DANGER
Risque de brûlure
Ne pas toucher si en marche
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or
maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred
to GE Lighting Solutions.
g
GE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
16943533----888
g
GE
Lighting Solutions
Through-Feed Conduit:
Note: Some units may not allow this mounting or
may require special high temperature cable. See
labels on back plate for instruction.
Knock-out holes are provided to permit mounting of the
back plate on vertical surfaces with two 3/8'’ bolts (not
provided). The -inch conduit is then positioned in the
cradles on each side of back plate and secured to back plate
with clips and screws provided (see figure 2). The conduit
may also be secured to the wall on either side of the fixture
with conduit straps (not provided). Wire the unit (see
Wiring). Knock-out the sections on each side of the front
housing using pliers, twisting inwardly. Re-attach the front
housing/reflector over the back plate. For W25C having
socket mounted in front housing, plug wire assembly must
be re-connected as front housing is installed.
Install lamp (see LAMP INSTALLATION) and re-install
refractor or cut-off optical assembly.
NOTE: Do not overcompress the gasket on acrylic
lens units as this may cause the lens to crack around
the screw holes.
B. WIRING
Make all electrical connections in accordance with
the National Electrical Code and any applicable local
code requirements.
Verify that supply voltage is correct by comparing it
to nameplate.
Customer wiring enters either through the center hole in
the back plate or through the conduit entrance knock-outs
on the sides of the front housing. In either case, an easy
access wiring area (see figure 2) is provided for electrical
connections.
Route incoming supply conductors through clips
provided and maintain half inch minimum spacing
from ballast and reflector.
NOTE: Connect ground lead to ground (gnd) screw
on the back plate.
Do not remove insulated connectors from wires not
needed for required voltage connection.
IF SINGLE VOLTAGE:
All single voltage ballasts are pre-wired such that user
need only connect the supply conductors.
IF MULTIVOLT: (120/208/240/277 volts)
Connect the ballast lead with the insulated terminal to
the desired voltage terminal as indicated on the ballast
terminal nameplate.
IF MULTIWATT:
Multiwatt ballasts are available in various combinations of
wattage. See wiring instructions on wiring tag inside the
luminaire.
To complete installation refer to MOUNTING.
LAMP INSTALLATION
CAUTION
Risk of burn
Allow lamp/fixture to cool before
handling
WARNING
Risk of burn
Do not touch operating luminaire
Use only lamps specified on nameplate. Observe
lamp manufacturer’s recommendations and
restrictions on lamp operation, particularly ballast
type, burning position, etc.
Lamp Tightness-Mogul Base Lamp: The lamp should be
securely inserted to the NEMA-EEI specified torque of 35
inch-pounds, which is best achieved by very firm tightening
sufficient to fully depress and load the center contact of the
socket.
Lamp Tightness-Medium Base Lamp: The lamp should
be tightened to a light firmness sufficient to depress the
center contact.
MAINTENANCE AND CLEANING
It will occasionally be necessary to clean the outside of
the refractor to maintain light levels. Frequency of cleaning
will depend on ambient dirt level and minimum light level
which is acceptable to the user. The refractor should be
washed in a solution of warm water and any mild,
nonabrasive household detergent, rinsed with clean water
and wiped dry. Should the optical assembly become dirty on
the inside, wipe the reflector and clean the refractor in the
above manner.
The light output of a luminaire is dependent on the age
of the lamp. In applications where the light level is critical,
it may be desirable to replace lamps before they burn out.
The lamp manufacturer can provide data showing how the
lamp light output decreases with use.
GEH-5794
Luminaires Wallighter
175 et 250 à écran
INSTRUCTIONS
À LIRE TOTALEMENT AVANT D'INSTALLER
W1LR, W1SR, W1LG, W1SG, W25C (optique à écran)
A. MONTAGE
GÉNÉRALITÉS
Ce luminaire est conçu pour les applications d'éclairage en
extérieur, et ne doit pas être utilisé dans des zones à ventilation
limitée, ou dans des lieux fermés à température élevée. Pour une
performance optimale, il doit être installé et entretenu en suivant les
recommendations suivantes.
DÉBALLAGE
Ce luminaire a été soigneusement emballé de sorte qu'aucune
pièce ne devrait avoir été endommagée pendant le transport.
Effectuez une inspection pour le confirmer.
INSTALLATION
Le réfracteur doit être déposé pour accéder aux deux écrous (un
de chaque côté du réflecteur) qui attachent le boîtier avant à la
plaque arrière. La dépose du boîtier avant permet de procéder au
montage et au câblage.
NOTE : Sur les modèles marqués W25C ayant la douille
montée sur le boîtier avant, l'assemblage de bornier
enfichable situé sur le centre haut du panneau arrière doit
être débranché avant de pouvoir déposer le boîtier avant.
Un joint statique est fourni avec l'appareil pour son montage sur
une boîte de raccordement électrique, et doit être installé entre la
partie postérieure de la plaque arrière et la surface de montage. S'il y a
besoin de plus d'étanchéité, colmatez l'arrière du boîtier avec de
l'enduit générique sans durcissement (non fourni) sur son sommet et
en bas sur les côtés.
Montage sur boîte de raccordement électrique : Le luminaire peut
être monté sur une boîte de raccordement électrique adéquate à
surface en saillie (forme octogonale de 3'’ ou 4'’, ou rectangulaire de
2'’x4'’ ). Sa plaque arrière peut être fixée à cette boîte de
raccordement avec deux vis (non fournies) de dimension approxima-
tive 10-24'’’. Une autre méthode de montage de la plaque arrière sur
une boîte de raccordement en saillie est de la positionner puis de la
fixer avec deux boulons de 3/8'’ (non fournis) au travers des trous
repoussés dans le panneau arrière (voir figure 2). Câblez l'appareil
(voir le section CÂBLAGE). Rattachez le boîtier avant/réflecteur sur
la plaque arrière. Pour les modèles W25C à douille sur le boîtier avant,
rebranchez l'assemblage de bornier enfichable au remontage.
Figure 1
Figure 2
4 PERÇAGES
Ø 9mm (.356")
2 PERÇAGES Ø 11mm (.437")
4 PERÇAGES Ø 5mm (.188")
À UTILISER POUR MONTAGE SUR
BOÎTE OCTOGONALE 83mm (3.250")
4 PERÇAGES Ø 5mm (.188")
À UTILISER POUR MONTAGE SUR
BOÎTE OCTOGONALE 102mm (4")
2 PERÇAGES Ø 5mm (.188")
À UTILISER POUR MONTAGE SUR
BOÎTE GEM
.688 in (17mm) DIA
BOUCHON D
É
FONÇABLE
POUR ASSEMBLAGE
327mm
(12.875 in)
73mm
(2.875 in)
161mm
(6.344 in)
35mm (1.375 in) MAX
16mm (.625 in) MIN
22mm (.875 in) DIA
4mm
(.150 in)
102mm
(4.000 in)
203mm
(8.000 in)
111mm
(4.375 in)
367mm
(14.438 in)
ATTENTION
Risque de chute en cas de mauvais
montage - Suivre les instructions
DANGER
Risque d'électrocution
Mettre hors tension avant
d'intervenir - Suivez les instructions
DANGER
Risque d'incendie
Utilisez le câble d'alimentation
spécifié sur la plaque d'identification
Ces instructions n'ont pas pour destination de couvrir tous les détails ou variantes de l'équipement, ni de répondre à toutes les éventualités que vous pourriez rencontrer pendant l'installation,
le fonctionnement ou l'entretien. Si vous souhaitez des informations complémentaires, ou si vous rencontrez un problème particulier qui ne soit pas adressé de votre point de vue d'acheteur,
le sujet doit être remonté jusqu'à la société GE Lighting Solutions
g
GE
Lighting Solutions
Through-Feed Conduit:
Note: Some units may not allow this mounting or
may require special high temperature cable. See
labels on back plate for instruction.
Knock-out holes are provided to permit mounting of the
back plate on vertical surfaces with two 3/8'’ bolts (not
provided). The -inch conduit is then positioned in the
cradles on each side of back plate and secured to back plate
with clips and screws provided (see figure 2). The conduit
may also be secured to the wall on either side of the fixture
with conduit straps (not provided). Wire the unit (see
Wiring). Knock-out the sections on each side of the front
housing using pliers, twisting inwardly. Re-attach the front
housing/reflector over the back plate. For W25C having
socket mounted in front housing, plug wire assembly must
be re-connected as front housing is installed.
Install lamp (see LAMP INSTALLATION) and re-install
refractor or cut-off optical assembly.
NOTE: Do not overcompress the gasket on acrylic
lens units as this may cause the lens to crack around
the screw holes.
B. WIRING
Make all electrical connections in accordance with
the National Electrical Code and any applicable local
code requirements.
Verify that supply voltage is correct by comparing it
to nameplate.
Customer wiring enters either through the center hole in
the back plate or through the conduit entrance knock-outs
on the sides of the front housing. In either case, an easy
access wiring area (see figure 2) is provided for electrical
connections.
Route incoming supply conductors through clips
provided and maintain half inch minimum spacing
from ballast and reflector.
NOTE: Connect ground lead to ground (gnd) screw
on the back plate.
Do not remove insulated connectors from wires not
needed for required voltage connection.
IF SINGLE VOLTAGE:
All single voltage ballasts are pre-wired such that user
need only connect the supply conductors.
IF MULTIVOLT: (120/208/240/277 volts)
Connect the ballast lead with the insulated terminal to
the desired voltage terminal as indicated on the ballast
terminal nameplate.
IF MULTIWATT:
Multiwatt ballasts are available in various combinations of
wattage. See wiring instructions on wiring tag inside the
luminaire.
To complete installation refer to MOUNTING.
LAMP INSTALLATION
CAUTION
Risk of burn
Allow lamp/fixture to cool before
handling
WARNING
Risk of burn
Do not touch operating luminaire
Use only lamps specified on nameplate. Observe
lamp manufacturer’s recommendations and
restrictions on lamp operation, particularly ballast
type, burning position, etc.
Lamp Tightness-Mogul Base Lamp: The lamp should be
securely inserted to the NEMA-EEI specified torque of 35
inch-pounds, which is best achieved by very firm tightening
sufficient to fully depress and load the center contact of the
socket.
Lamp Tightness-Medium Base Lamp: The lamp should
be tightened to a light firmness sufficient to depress the
center contact.
MAINTENANCE AND CLEANING
It will occasionally be necessary to clean the outside of
the refractor to maintain light levels. Frequency of cleaning
will depend on ambient dirt level and minimum light level
which is acceptable to the user. The refractor should be
washed in a solution of warm water and any mild,
nonabrasive household detergent, rinsed with clean water
and wiped dry. Should the optical assembly become dirty on
the inside, wipe the reflector and clean the refractor in the
above manner.
The light output of a luminaire is dependent on the age
of the lamp. In applications where the light level is critical,
it may be desirable to replace lamps before they burn out.
The lamp manufacturer can provide data showing how the
lamp light output decreases with use.
GEH-5794
Luminaires Wallighter
175 et 250 à écran
INSTRUCTIONS
À LIRE TOTALEMENT AVANT D'INSTALLER
W1LR, W1SR, W1LG, W1SG, W25C (optique à écran)
A. MONTAGE
GÉNÉRALITÉS
Ce luminaire est conçu pour les applications d'éclairage en
extérieur, et ne doit pas être utilisé dans des zones à ventilation
limitée, ou dans des lieux fermés à température élevée. Pour une
performance optimale, il doit être installé et entretenu en suivant les
recommendations suivantes.
DÉBALLAGE
Ce luminaire a été soigneusement emballé de sorte qu'aucune
pièce ne devrait avoir été endommagée pendant le transport.
Effectuez une inspection pour le confirmer.
INSTALLATION
Le réfracteur doit être déposé pour accéder aux deux écrous (un
de chaque côté du réflecteur) qui attachent le boîtier avant à la
plaque arrière. La dépose du boîtier avant permet de procéder au
montage et au câblage.
NOTE : Sur les modèles marqués W25C ayant la douille
montée sur le boîtier avant, l'assemblage de bornier
enfichable situé sur le centre haut du panneau arrière doit
être débranché avant de pouvoir déposer le boîtier avant.
Un joint statique est fourni avec l'appareil pour son montage sur
une boîte de raccordement électrique, et doit être installé entre la
partie postérieure de la plaque arrière et la surface de montage. S'il y a
besoin de plus d'étanchéité, colmatez l'arrière du boîtier avec de
l'enduit générique sans durcissement (non fourni) sur son sommet et
en bas sur les côtés.
Montage sur boîte de raccordement électrique : Le luminaire peut
être monté sur une boîte de raccordement électrique adéquate à
surface en saillie (forme octogonale de 3'’ ou 4'’, ou rectangulaire de
2'’x4'’ ). Sa plaque arrière peut être fixée à cette boîte de
raccordement avec deux vis (non fournies) de dimension approxima-
tive 10-24'’’. Une autre méthode de montage de la plaque arrière sur
une boîte de raccordement en saillie est de la positionner puis de la
fixer avec deux boulons de 3/8'’ (non fournis) au travers des trous
repoussés dans le panneau arrière (voir figure 2). Câblez l'appareil
(voir le section CÂBLAGE). Rattachez le boîtier avant/réflecteur sur
la plaque arrière. Pour les modèles W25C à douille sur le boîtier avant,
rebranchez l'assemblage de bornier enfichable au remontage.
Figure 1
Figure 2
4 PERÇAGES
Ø 9mm (.356")
2 PERÇAGES Ø 11mm (.437")
4 PERÇAGES Ø 5mm (.188")
À UTILISER POUR MONTAGE SUR
BOÎTE OCTOGONALE 83mm (3.250")
4 PERÇAGES Ø 5mm (.188")
À UTILISER POUR MONTAGE SUR
BOÎTE OCTOGONALE 102mm (4")
2 PERÇAGES Ø 5mm (.188")
À UTILISER POUR MONTAGE SUR
BOÎTE GEM
.688 in (17mm) DIA
BOUCHON D
É
FONÇABLE
POUR ASSEMBLAGE
327mm
(12.875 in)
73mm
(2.875 in)
161mm
(6.344 in)
35mm (1.375 in) MAX
16mm (.625 in) MIN
22mm (.875 in) DIA
4mm
(.150 in)
102mm
(4.000 in)
203mm
(8.000 in)
111mm
(4.375 in)
367mm
(14.438 in)
ATTENTION
Risque de chute en cas de mauvais
montage - Suivre les instructions
DANGER
Risque d'électrocution
Mettre hors tension avant
d'intervenir - Suivez les instructions
DANGER
Risque d'incendie
Utilisez le câble d'alimentation
spécifié sur la plaque d'identification
Ces instructions n'ont pas pour destination de couvrir tous les détails ou variantes de l'équipement, ni de répondre à toutes les éventualités que vous pourriez rencontrer pendant l'installation,
le fonctionnement ou l'entretien. Si vous souhaitez des informations complémentaires, ou si vous rencontrez un problème particulier qui ne soit pas adressé de votre point de vue d'acheteur,
le sujet doit être remonté jusqu'à la société GE Lighting Solutions
g
GE
Lighting Solutions
GEH-5794
Wallighter 175 and
Wallighter 250 Cutoff Luminaires
INSTRUCTIONS
READ THOROUGHLY BEFORE INSTALLING
2
W1LR, W1SR, W1LG, W1SG, W25C (cutoff optics)
A. MOUNTING
GENERAL
This luminaire is designed for outdoor lighting
applications, and should not be used in areas of limited
ventilation, or in high ambient temperature enclosures.
For optimum performance, it should be installed and
maintained according to the following recommendations.
UNPACKING
This luminaire has been properly packed so that no parts
should have been damaged during transit. Inspect to
confirm.
INSTALLATION
The refractor must be removed to access two bolts (on
each side of the reflector) which secures front housing to
back plate. Removal of the front housing allows access for
mounting and wiring.
NOTE: For units marked W25C having socket
mounted in front housing, plug wire assembly
located in center top of back plate must be un-
plugged while removing front housing.
A gasket is provided with the unit to be used when
mounting over an outlet box, and should be installed
between rear of back plate and the mounting surface. If
additional sealing is desired, caulk back of housing with
generic non-hardening sealant (not provided) across the
top and down both sides.
Outlet Box Mounting: The luminaire can be mounted to
a suitable surface-mounted outlet box (3'’ or 4'’ octagon, or
2'’x4'’ rectangular). The back plate may be attached to the
outlet box with two 10-24 screws (not provided), approxi-
mately ‘’ long. An alternate method of mounting the back
plate over a surface-mounted outlet box is to position back
plate over box and mount with two 3/8'’ bolts (not
provided) through the knock-out holes provided in the back
plate (see figure 2). Wire the unit (see Wiring). Reattach
the front housing/reflector over the back plate. For W25C
having socket mounted in front housing, plug wire assembly
must be re-connected as front housing is installed.
Figure 1
Figure 2
Tube protecteur d'alimentation :
Note : Certains modèles peuvent ne pas permettre ce
montage ou nécessiter du câblage spécial haute
température. Reportez-vous aux étiquettes sur la
plaque arrière pour les instructions.
Des bouchons défonçables sont disponibles pour permettre le
montage de la plaque arrière sur des surfaces verticales avec deux
boulons de 3/8 po (non fournis). Le tube protecteur d'alimentation
est positionné sur les supports de chaque côté de la plaque arrière, et
fixé avec les colliers et vis fournis (voir figure 2). Le tube peut aussi
être fixé au mur d'un côté ou de l'autre du luminaire avec des brides
pour tuyau (non fournies). Faites les raccordements (voir la section
CÂBLAGE). Repoussez les surfaces de passage de chaque côté du
boîtier avant en utilisant des pinces, en les tordant vers l'intérieur.
Rattachez le boîtier avant et réflecteur sur la plaque arrière. Pour le
modèle W25C qui a la douille montée sur le boîtier avant, il faut
rebrancher le bloc bornier d'alimentation amovible au remontage.
Mettez l'ampoule en place (voir la section INSTALLATION
D'AMPOULE) et remontez le réfracteur ou l'assemblage optique à
écran.
NOTE : Ne mettez pas une pression excessive du joint sur les
lentilles acryliques car elles pourraient alors se fissurer
autour des trous de vissage.
B. CÂBLAGE
Établissez toutes les liaisons électriques en conformité avec
la norme NEC ou vos réglementations locales en vigueur.
Vérifiez que la tension secteur disponible est compatible avec
celle de l’appareil indiquée sur sa plaque d’identification.
Le câblage par le client arrive soit par le trou central de la
plaque arrière, soit par les passages pour tube protecteur
d'alimentation sur les côtés du boîtier avant. Dans les deux
cas un accès facile à la zone de câblage (voir figure 2) est
fourni pour les connexions électriques.
Faites passer les fils d'arrivée d'alimentation dans les passe-
fils fournis et gardez au moins un écartement de 13 mm par
rapport au ballast et au réflecteur.
NOTE : Connectez l'arrivée de masse sur la vis de terre
(marquée <<gnd>>) de la plaque arrière.
N'enlevez pas les bornes isolantes des fils non nécessaires
pour la connexion de tension requise.
MONO-TENSION
Tous les ballasts pour les modèles mono-tension sont précâblés de
sorte que l’usager n’ait qu’à relier les fils conducteurs
d’alimentation.
MULTI-TENSION – (120/208/240/277 volts)
Connectez la sortie du ballast ayant la borne isolée sur la borne de tension
voulue comme indiqué sur la plaque d’identification sur le ballast.
MULTI-PUISSANCE
Des ballasts sont disponibles pour diverses combinaisons de
puissances. Reportez-vous aux instructions de câblage sur
l'étiquette de câblage située à l'intérieur du luminaire.
Pour terminer l'installation reportez-vous à MONTAGE.
INSTALLATION D'AMPOULE
35-201578-4A (7/00)
N’utilisez que le type d’ampoules spécifié sur la plaque
d’identification. Suivez les recommandations et restrictions des
fabricants d’ampoules, en particulier pour le type de ballast, la position
d’utilisation, etc.
Serrage d’ampoule- modèle à culot Mogul : l’ampoule doit être
mise en place de façon sûre, par un serrage NEMA-EEI spécifié au
couple de 35 pouces-livres, qui s’effectue le plus aisément par un
serrage manuel ferme. Le vissage doit être suffisant pour
complètement abaisser et charger le contact central de la douille.
Serrage d’ampoule- modèle à culot moyen : L’ampoule doit être
vissée en douceur assez loin pour enfoncer le contact central de sa
douille.
ENTRETIEN ET NETTOYAGE
Il faudra à l’occasion nettoyer le réfracteur pour maintenir son
apparence et le niveau d’éclairage. La fréquence de nettoyage
dépendra de la densité de poussière ambiante et du niveau minimum
d’éclairage désiré. Le réfracteur et le boîtier seront lavés avec une
solution d’eau chaude et de détergent ménager léger, puis rincés à
l’eau claire et séchés par essuyage. Si l’ensemble optique interne
devenait sale, nettoyez le réflecteur et l’intérieur du réfracteur de la
même façon. Remplacez le joint statique s’il est endommagé.
La puissance lumineuse générée par le luminaire est également
dépendante de l’âge de son ampoule. Pour les applications où le
niveau lumineux est critique, il peut être souhaitable de remplacer les
ampoules avant qu’elles ne grillent. Le fabricant d'ampoules peut
fournir des données sur la baisse de luminosité en fonction du
vieillissement.
WARNING
Risk of electric shock
Turn power off before servicing
see instructions
WARNING
Risk of fire
Use supply wire specified on
nameplate
CAUTION
Unit will fall if not installed properly
Follow installation instructions
ATTENTION
Risque de brûlure
Laissez le bloc d’ampoule refroidir
avant d’y toucher
DANGER
Risque de brûlure
Ne pas toucher si en marche
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or
maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred
to GE Lighting Solutions.
g
GE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
16943533----888
g
GE
Lighting Solutions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

GE W1LR Guide d'installation

Taper
Guide d'installation

dans d''autres langues