Tools and Materials
Important Information
CAUTION: Risk of personal injury. Do not use the bath
filler as a grab bar or support bar when entering or exiting
the bath. The bath filler is not designed to support weight.
NOTICE: To avoid damage to the O-rings on the bottom of the
faucet, keep the faucet vertical and use care when installing the
faucet.
NOTE: A minimum operating pressure of 45 psi (310 kPa) is
required for proper operation. If a pressure of less than 45 psi (310
kPa) is present, contact a plumber or choose another faucet.
For use with automatic compensating valves rated at 1.6 gal/min
(6.1 l/min) or less.
Observe all local plumbing and building codes.
Shut off the water supply.
A drill bit is provided for installation to wood support. Use an
appropriate drill bit for other materials.
The dimensions given assume the spout and bath are mounted on
the same surface. Adjust the dimensions accordingly if the spout
and bath are mounted on different surfaces.
If this product is installed with an overflowing bath, the outer rim
of the bath should slightly overlap the 2x4 framing.
Installer supplied copper tubing must be 5/8 OD (1/2
Nominal).
Carefully review this document and any appropriate rough-in
sheets. Design the bath enclosure accordingly.
Sealant Tape
Plus:
• 3/16" Masonry Bit (for concrete installation)
• Conventional Woodworking Tools
• Plumbing Tools and Materials
1240534-2-C 2 Kohler Co.
Important Information (cont.)
The appearance of your faucet may differ from the illustrations in
this guide. The instructions still apply.
Kohler Co. 3 1240534-2-C
1. Prepare the Site
IMPORTANT! 2x6 lumber is NOT adequate for this application.
Bath
Finished
Floor
Subfloor
2-7/8"
(73 mm) Min
3-11/16"
(94mm) Max
Wood Support
2-3/4" (70 mm)-
3-9/16" (90 mm)
Finished
Floor
3-15/16"
(100 mm)
Min
Finished
Wall
Base
Centerline
1240534-2-C 4 Kohler Co.
Prepare the Site (cont.)
NOTICE: Adequate floor support is required. The wood support
must be a minimum of 2 (51 mm) thick by 6 (152 mm) wide. 2x6
lumber is NOT adequate for this application.
NOTE: Concrete can be used as the floor support.
Plan out the bath filler placement based on the dimensions above.
Cut a hole in the subfloor large enough to install the wood
support between two floor joists.
Secure a wood support 2-7/8 (73 mm) - 3-11/16 (94 mm) below
the height of the finished floor.
Kohler Co. 5 1240534-2-C
2. Spout Orientation
NOTE: Verify correct spout orientation before securing the base to
the wooden support.
NOTE: The base has a blue mark and a notch on the cold supply
side.
Orient the base with the cold supply side notch placed in the
direction shown.
If possible, dry fit the faucet to the base using the screws and
washers. Orient the spout to the inside of the bath.
If your faucet is not available at this time, make sure the base is
positioned so the faucet will properly run water into the bath.
Mark the mounting hole locations on the wooden support.
Mark the orientation of the base and where the notch is
positioned on the wooden support.
Wall
Pencil
Hot
Bath
Cold
1240534-2-C 6 Kohler Co.
3. Install the Base
If attached, remove the faucet from the base.
Drill 1-1/2 (380 mm) deep holes with a 3/16 drill bit (provided)
using the marked locations as the center point.
If using concrete as the floor support, drill 1-1/2 (380 mm) deep
holes with a 3/16 masonry bit (not provided).
Realign the base to the position you marked. Make sure the cold
supply side notch is in the correct orientation.
Secure the base to the support with the screws and washers
provided.
Verify the base is level and tighten the screws.
Floor
Joist
Wood
Support
3/16"
Mounting
Hole
Base
Washer
Screw
Kohler Co. 7 1240534-2-C
4. Connect the Supplies
NOTE: The base has a blue mark and a notch on the cold supply
side.
Apply sealant tape on the ½ NPT hot and cold supply pipes and
thread into the base.
Insert the plugs into the base.
Turn on the water supply and check for leaks.
Turn off the water supply.
Secure the guard onto the base with the screws provided.
Guard
Screw
Cold Supply
Base
Plug
Hot Supply
Notch
Blue Mark
1240534-2-C 8 Kohler Co.
5. Install the Finished Floor
Finish the floor leaving a 3-1/4 (83 mm) diameter hole for the
guard.
Cut the guard so it is flush with the finished flooring.
Guard
Finished Floor
3-1/4"
(83 mm)
Fit the finished floor
between the
Min and Max lines.
Kohler Co. 9 1240534-2-C
6. Install the Faucet
NOTICE: To avoid damage to the O-rings on the bottom of the
faucet, keep the faucet vertical and use care when installing the
faucet.
Make sure the water is turned off.
Relieve the water pressure.
Remove the plugs from the base.
Remove the rubber protector (not shown) from the faucet.
Place the faucet onto the base and insert the screws and washers
provided through the flange.
Tighten the screws using the hex wrench provided.
Slide the escutcheon down onto the floor, covering the base.
Hex
Wrench
Escutcheon
Screw
Washer
Flange
Plug
Base
1240534-2-C 10 Kohler Co.
7. Install the Handshower
Install the handshower hose as shown.
Handshower
Holder
Hose
Diverter
Washer
Kohler Co. 11 1240534-2-C
8. Installation Checkout
Ensure the faucet handle is in the OFF position.
Remove the aerator from the spout.
Turn on the water supply and check for leaks.
Point the hose into the bath and turn the faucet handle to the ON
position.
Pull the diverter out to send water through the hose to remove
debris.
Turn the faucet off to reset the diverter.
Turn the faucet on and run hot and cold water through the spout
to remove debris.
Check for leaks.
Turn the faucet off.
Reinstall the aerator and install the handshower to the hose. Place
the handshower into the handshower holder.
Aerator
Handle
Handshower
Diverter
Handshower
Holder
Handshower
Washer
Hose
1240534-2-C 12 Kohler Co.
Care and Cleaning
For best results, keep the following in mind when caring for your
KOHLER product:
Use a mild detergent such as liquid dishwashing soap and warm
water for cleaning. Do not use abrasive cleaners that may scratch
or dull the surface.
Carefully read the cleaner product label to ensure the cleaner is
safe for use on the material.
Always test your cleaning solution on an inconspicuous area
before applying to the entire surface.
Do not allow cleaners to sit or soak on the surface.
Wipe surfaces clean and rinse completely with water immediately
after cleaner application. Rinse and dry any overspray that lands
on nearby surfaces.
Use a soft, dampened sponge or cloth. Never use an abrasive
material such as a brush or scouring pad to clean surfaces.
For detailed cleaning information and products to consider, visit
www.kohler.com/clean. To order Care & Cleaning information, call
1-800-456-4537.
Warranty
KOHLER
®
Faucet Lifetime Limited Warranty
Kohler Co. warrants its Faucets* manufactured after January 1, 1997, to
be leak and drip free during normal residential use for as long as the
original consumer purchaser owns his or her home. If the Faucet
should leak or drip during normal use, Kohler Co. will, free of charge,
mail to the purchaser the cartridge necessary to put the Faucet in good
working condition. This warranty applies only to Kohler Faucets
installed in the United States of America, Canada or Mexico (North
America).
Kohler Co. also warrants all other aspects of the faucet or accessories
(Faucet)*, (except gold, non-Vibrant
®
, non-chrome finishes) to be free
of defects in material and workmanship during normal residential use
for as long as the original consumer purchaser owns his or her home.
This warranty applies only to Kohler Faucets installed in North
America. If a defect is found in normal residential use, Kohler Co. will,
at its election, repair, provide a replacement part or product, or make
appropriate adjustment. Damage to a product caused by accident,
misuse, or abuse is not covered by this warranty. Improper care and
Kohler Co. 13 1240534-2-C
Warranty (cont.)
cleaning will void the warranty**. Proof of purchase (original sales
receipt) must be provided to Kohler Co. with all warranty claims.
Kohler Co. is not responsible for labor charges, installation, or other
incidental or consequential costs. In no event shall the liability of
Kohler Co. exceed the purchase price of the Faucet.
If the Faucet is used commercially or is installed outside of North
America, or if the finish is gold, non-Vibrant or a painted or powder
coated color finish, Kohler Co. warrants the Faucet to be free from
defects in material and workmanship for one (1) year from the date the
product is installed, under Kohler Co.’s standard one-year limited
warranty.
If you believe that you have a warranty claim, contact Kohler Co.,
either through your Dealer, Plumbing Contractor, Home Center or
E-tailer, or by writing Kohler Co., Attn.: Customer Care Center, 444
Highland Drive, Kohler, WI 53044, USA. Please be sure to provide all
pertinent information regarding your claim, including a complete
description of the problem, the product, model number, color, finish,
the date the product was purchased and from whom the product was
purchased. Also include your original invoice. For other information,
or to obtain the name and address of the service and repair facility
nearest you, call 1-800-4-KOHLER (1-800-456-4537) from within the
USA and Canada, and 001-800-456-4537 from within Mexico, or visit
www.kohler.com within the USA, www.ca.kohler.com from within
Canada, or www.mx.kohler.com in Mexico.
KOHLER CO. AND/OR SELLER ARE PROVIDING THESE
WARRANTIES IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. KOHLER CO. AND/OR
SELLER DISCLAIM ALL LIABILITY FOR SPECIAL, INCIDENTAL
OR CONSEQUENTIAL DAMAGES. Some states/provinces do not
allow limitations of how long an implied warranty lasts or the
exclusion or limitation of such damages, so these limitations and
exclusions may not apply to you. This warranty gives the consumer
specific legal rights. You may also have other rights that vary from
state/province to state/province.
This is Kohler Co.’s exclusive written warranty.
*Trend
®
faucets, MasterShower
®
tower, BodySpa systems and
components; WaterHaven
®
tower, systems and components; Tripoint
®
faucets, Polished Gold, non-Vibrant and painted or powder coated
finishes, fittings; all items within the Fixture Related section of the
Kohler Faucets Price Book, drains, Duostrainer
®
sink strainers,
1240534-2-C 14 Kohler Co.
Warranty (cont.)
soap/lotion dispensers, Moxie
®
Wireless Speaker; and faucets used in
commercial settings, and outside North America, are covered by
Kohler Co.’s one-year limited warranty.
**Never use cleaners containing abrasive cleansers, ammonia, bleach,
acids, waxes, alcohol, solvents or other products not recommended for
chrome. This will void the warranty.
Kohler Co. 15 1240534-2-C
Guide d’installation et d’entretien
Robinet de baignoire au plancher
Outils et matériaux
Informations importantes
ATTENTION: Risque de blessures. Ne pas utiliser le
remplisseur de baignoire en tant que barre d’appui pour
entrer ou sortir de la baignoire. Le remplisseur de baignoire
n’est pas conçu pour supporter un poids.
AVIS: Pour éviter d’endommager les joints toriques se trouvant sur
le bas du robinet, maintenir celui-ci à la verticale et procéder avec
soin lors de l’installation du robinet.
REMARQUE: Une pression de fonctionnement minimum de 45 psi
(310 kPa) est requise pour un fonctionnement adéquat. Si la pression
présente est inférieure à 45 psi (310 kPa), contacter un plombier ou
choisir un autre robinet.
À utiliser avec des vannes de compensation automatique d’une
valeur nominale de 1,6 gal/min (6,1 l/min) ou moins.
Respecter tous les codes de plomberie et de bâtiment locaux.
Fermer l’arrivée d’eau.
Une mèche est fournie pour une installation sur un support en
bois. Utiliser une mèche appropriée pour les autres matériaux.
Ruban
d'étanchéité
Plus:
• Mèche à maçonnerie de 3/16"
(pour installation sur du béton)
• Outils de menuiserie classiques
• Outils et matériaux de plomberie
Kohler Co. Français-1 1240534-2-C
Informations importantes (cont.)
Les dimensions fournies assument que le bec et la baignoire sont
montés sur la même surface. Ajuster les dimensions en
conséquence si le bec et la baignoire sont montés sur des surfaces
différentes.
Si le produit est installé avec une baignoire avec débordement, le
rebord extérieur de la baignoire doit légèrement chevaucher le
cadre 2x4.
Le diamètre extérieur de la tubulure en cuivre fournie par
l’installateur doit être égal à 5/8 (1/2 nominal).
Étudier ce document avec précaution ainsi que toutes les fiches
de raccordement appropriées. Concevoir l’enceinte de la baignoire
en conséquence.
L’apparence de votre robinet peut être différente des illustrations
de ce guide. Les instructions s’appliquent tout de même.
Kohler Co. Français-2 1240534-2-C
1. Préparer le site
IMPORTANT! Le bois 2x6 n’est PAS adéquat pour cette application.
Baignoire
Plancher
fini
Sous-plancher
2-7/8"
(73 mm) Min
3-11/16"
(94mm) Max
Support en bois
2-3/4" (70 mm)-
3-9/16" (90 mm)
Plancher
fini
3-15/16"
(100 mm)
Min
Mur
fini
Ligne centrale
de la base
1240534-2-C Français-3 Kohler Co.
Préparer le site (cont.)
AVIS: Un support de plancher adéquat est requis. Le support en
bois doit avoir au minimum une épaisseur de 2 (51 mm) par une
largeur de 6 (152 mm). Le bois 2x6 n’est PAS adéquat pour cette
application.
REMARQUE: Le béton peut être utilisé comme support de
plancher.
Prévoir le positionnement du remplisseur de baignoire en
fonction des dimensions ci-dessus.
Découper un trou assez grand dans le sous-plancher pour
installer le support en bois entre deux solives de plancher.
Fixer un support en bois de 2-7/8 (73 mm) - 3-11/16 (94 mm)
sous la hauteur du plancher fini.
Kohler Co. Français-4 1240534-2-C
2. Orientation du bec
REMARQUE: Vérifier l’orientation adéquate du bec avant de
sécuriser la base sur le support en bois.
REMARQUE: La base comprend un repère bleu et une encoche sur
le côté d’alimentation en eau froide.
Orienter la base avec l’encoche côté alimentation en eau froide
placée dans la direction indiquée.
Si possible, faire un ajustement à sec du robinet sur la base en
utilisant les vis et les rondelles. Orienter le bec sur l’intérieur de
la baignoire.
Si le robinet n’est pas disponible immédiatement, s’assurer que la
base est positionnée de manière à ce que le robinet fasse couler
l’eau correctement dans la baignoire.
Marquer les emplacements des orifices de fixation sur le support
en bois.
Marquer l’orientation de la base et l’emplacement l’encoche est
positionnée sur le support en bois.
Mur
Crayon
Chaud
Baignoire
Froid
1240534-2-C Français-5 Kohler Co.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Kohler K-T97331-4-SN Guide d'installation

Catégorie
Articles sanitaires
Taper
Guide d'installation