Premier Mounts CTM-MS3 Mode d'emploi

Taper
Mode d'emploi
Installation Guide
Installationsanleitung, Guía de Instalaon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
premiermounts.com | p. 800.368.9700 | e. [email protected]
500 W Central Ave, Suite A, Brea, CA 92821 USA
Warning Statements
Weight Limit
Maximum Flat Panel Weight: 300 lbs. THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING
AT LEAST FOUR TIMES THE WEIGHT OF THE FLAT PANEL. IF
NOT, THE WALL STRUCTURE MUST BE REINFORCED.
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND COMPLETELY
UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED IN THESE
INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR
EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE PROPER SAFETY
EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.
PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS PRODUCT FOR
PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR
MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION
OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR
MODIFICATIONS.
If mounting to wall studs or ceiling studs, make sure that the mounting screws are anchored into the center of the wall studs or ceiling studs.
It is recommended that a maximum of 5/8” plaster board be used when mounting to wooden studs.
Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there
are no electrical wires in wall. Cutting or drilling into an electrical line may cause serious personal injury.
Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a water or gas line
may cause severe property damage or personal injury.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious personal injury.
Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of impact.
AVANT L’INSTALLATION DE CE PRODUIT, LES CONSIGNES D’INSTALLATION DOIVENT ÊTRE LUES ET PLEINEMENT COMPRISES.
CONSERVER CES CONSIGNES D’INSTALLATION DANS UN ENDROIT FACILEMENT ACCESSIBLE POUR RÉFÉRENCE FUTURE.
LA PROCÉDURE D’INSTALLATION CORRECTE PAR UN TECHNICIEN QUALIFIÉ DOIT ÊTRE OBSERVÉE, COMME DÉCRIT DANS CES
CONSIGNES D’INSTALLATION. FAUTE DE QUOI DES DOMMAGES MATÉRIELS, BLESSURES GRAVES, VOIRE MÊME LA MORT PEUT
SUBVENIR.
DES MESURES DE SÉCURITÉ DOIVENT ÊTRE PRATIQUÉES À TOUT MOMENT DURANT L’ASSEMBLAGE DE CE PRODUIT. UTILISER
L’ÉQUIPEMENT ET OUTILS DE SÉCURITÉ APPROPRIÉ POUR LA PROCÉDURE D’ASSEMBLAGE AFIN D’ÉVITER DES BLESSURES.
LES SUPPORTS PREMIER MOUNTS NE GARANTISSENT PAS CONTRE LES DOMMAGES CAUSÉS PAR L’USAGE DU PRODUIT DE
MONTAGE PREMIER MOUNTS À D’AUTRES FINS QUE CELLES POUR LESQUELLES IL A ÉTÉ CONÇU OU DES DOMMAGES CAUSÉS
PAR DES ACCESSOIRES OU DES MODIFICATIONS NON AUTORISÉS, ET NOUS NE POUVONS PAS ÊTRE TENUS RESPONSABLES
DES DOMMAGES, PLAINTES, RÉCLAMATIONS, POURSUITES, ACTIONS OU CAUSES D’ACTION DE N’IMPORTE QUELLE
MANIÈRE RÉSULTANT DE, DÉCOULANT DE OU TOUCHANT DE N’IMPORTE QUELLE MANIÈRE UN TEL USAGE, ACCESSOIRE OU
MODIFICATION
Au moins deux pe s
matériels dû à la chute ou à la manipulation incorrecte de l’écran plat.
Si le montage s’effectue sur des rivets, assurez-vous que les vis de montage sont ancrées au centre des rivets. L’usage d’un détecteur de rivet
bord-à-bord est recommandé.
Il est recommandé qu’un maximum de plaque-plâtre de ⅝″ soit utilisé lors d’un montage sur des rivets à bois.
Familiarisez-vous avec l’environnement de montage. Si un perçage et/ou une coupe est opéré sur la surface de montage, assurez-vous
S’assurer qu’il n’y a pas de canalisation d’eau à l’intérieur du mur où le montage doit être localisé. Une coupe/perçage dans une canalisation
d’eau peut causer sérieusement endommager le circuit d’eau au niveau de la surface de montage.
Ce produit n’est destiné qu’à être utilisé à l’intérieur. L’utilisation de ce produit à l’extérieur pourrait entraîner des défauts matériels et/ou des
blessures graves.
Ne pas installer près de sources de forte chaleur. Ne pas installer sur une structure soumise aux vibrations, aux mouvements ou aux chocs.
AVERTISSEMENT
Page 2 premiermounts.com | p. 800.368.9700 | e. [email protected]
Wall Plate Mounting
Bracket Griplate™
Washer 5/16" Flat
Washer
Universal
Spacers M6 Safety
Knurl Knob
Thread Depth
Indicator
(Supplied)
5/16" x 3"
Lag Bolt
Panelock™
Hardware Kit M6 x 12mm
Security Head
Allen Wrench
M6 x 16mm M8x 16mm M8 x 20mm
M6 x 20mm M6 x 30mm
x1x1 x1 Pairx9
x4 x2 x9
x4
x2 x1 x2
x4 x4 x6 x4 x4
M6 or 1/4"
Wood Drill bit
3/8" Masonry
Drill bit
13mm or 1/2"
Socket
Finned Anchor
Level
X
X
X
Directional Mounting Arrow
The Directional Mounting Arrow stamped into the CTM-MS3 wall plate
indicates which edge is the top.
Visual Centering Diamond
The Visual Centering Diamond will guide you in determining the screen
placement on the wall.
Mounting Safety
Two people are recommended to install the wall plate.
Il est recommandé deux personnes pour l’installation de ce support.
You must secure the wall plate to three (3) wall studs with a minimum of
nine (9) lag bolts (3 lag bolts for each stud found)
Vous devez assembler la sablière sur trois (3) rivets de mur avec un
minimum de neuf (9) tirefonds (3 tirefonds pour chaque rivet trouvé).
1)
the vicinity of the wall plate.
2) Use a pencil to mark the exact center of each of the wall studs.
Minimum of 2 x 4 wood stud to be used
Minimum de 2 x 4 bois goujon pour être utilisé
WOOD STUD INSTALLATION
x9
Page 3
1
Installation Guide
Installationsanleitung, Guía de Instalaon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
Included components
Required for installation
premiermounts.com | p. 800.368.9700 | e. [email protected]
3
2
Page 4
CTM-MS3
Installation Guide
Installationsanleitung, Ga de Instalacíon, Guida de Installazione, Guide dInstallation, Installatie gids
X
X
X
Drill a “pilot hole” in the center of the upper right mark using a 1/4" drill
bit and power drill.
Only use a 1/4"drill bit when drilling pilot holes.
N’utiliser qu’un foret de 1/4” lors du forage de guidage.
Two people are recommended for this step; one person to
level the wall plate and another person to mark the wall stud
location.
Il est recommandé deux personnes pour cette étape : une
personne pour niveler la sablière et une autre personne pour
marquer l’emplacement de l’ossature murale à claire-voie.
1) Place the wall plate against the wall in the desired viewing
location.
2) Adjust the wall plate to align the mount slots in the wall plate with
the center of the wall studs.
3) Use a pencil to mark the upper right mounting location along the
center of the wall stud.
premiermounts.com | p. 800.368.9700 | e. [email protected]
5
4
Page 5
Installation Guide
Installationsanleitung, Guía de Instalaon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
1) Level the wall plate.
2) Use a pencil to mark the remaining eight (8) mounting locations
along the center of each wall stud.
1) Place the wall plate against the wall and align it with the pilot
hole.
2) Insert one (1) 5/16˝ x 3˝ lag bolt and one (1) 5/16˝ washer into the
upper right pilot hole.
3) Use a socket wrench and a 1/2˝ socket to tighten the lag bolt.
Do not over tighten the lag bolt.
Éviter de trop serrer les tirefonds.
premiermounts.com | p. 800.368.9700 | e. [email protected]
-
port au mur. Une installation incorrecte peut entraîner des
blessures ou des dommages matériels.
6
7
Page 6
Installation Guide
Installationsanleitung, Guía de Instalaon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
1) Insert one (1) 5/16″ x 3″ lag bolt and one (1) 5/16″ washer into
each pilot hole
2) Tighten all lag bolts using a socket wrench and 1/2″ socket.
Do not over tighten the lag bolts when attaching the mount to
the wall. Improper installation may result in personal injury or
property damage.
Drill a “pilot hole” in the center of each of the marks with a power drill
and a 1/4″ drill bit.
Two people are recommended for this step; one person to
level the wall plate and another person to drill the pilot holes.
Il est recommandé deux personnes pour cette étape : une
personne pour niveler la sablière et une autre personne pour
percer le forage de guidage.
Only use 1/4" drill bit when drilling the pilot holes.
N’utiliser qu’un foret de 1/4” lors du forage de guidage.
premiermounts.com | p. 800.368.9700 | e. [email protected]
CONCRETE WALL INSTALLATION
Two people are recommended for this step: one person to
level the wall plate and another person to mark the mounting
locations.
Il est recommandé deux personnes pour cette étape : une
personne pour niveler la sablière et une autre personne pour
marquer les emplacements de montage.
8
9
Page 7
Installation Guide
Installationsanleitung, Guía de Instalaon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
Drill nine (9) pilot holes of each mark using a drill and 3/8” masonary drill
bit. Drill 3 inches deep.
Only use a 3/8" masonary drill bit when drilling pilot holes.
N’utiliser qu’un foret de 3/8” lors du forage de guidage.
premiermounts.com | p. 800.368.9700 | e. [email protected]
10
Page 8
11
Installation Guide
Installationsanleitung, Ga de Instalacíon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
5/16" Flat Washer
5/16" x 3" Lag Bolt
x9
x9
Insert the lag bolts and washers into the Finned Anchors.Tighten all lag
bolts using a socket wrench and 1/2″ or 13mm socket.
Do not over tighten the lag bolts.
Éviter de trop serrer les tirefonds.
Insert a Finned Anchors into each hole. Lightly tap each Finned Anchors
into place with a hammer.
x9
premiermounts.com | p. 800.368.9700 | e. [email protected]
Si la vis que vous sélectionnez est plus longue que la marque du jeu
maximal de 1/8” sur le paillon ou le cure-dents, comme illustré sur le
schéma 2 et le schéma 3, veuillez ne pas utiliser cette vis. La longueur
de la vis doit dévier la marque.
et sortez pas lorsqu'une tension est appliquée.
12
Page 9
13
Installation Guide
Installationsanleitung, Ga de Instalacíon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
Selecting the Mounting Hardware
1) Insert a small straw or toothpick into the threaded inserts found
2) Use a pencil to mark the depth of the threaded insert on the small
straw or toothpick.
3) Mark the straw or toothpick 1/8” above the depth of the threaded
insert, as shown in Figure 1.
4) Insert the small straw or toothpick into the remaining threaded
inserts to compare and verify their depth using the straw or
toothpick’s 1/8” allowance mark.
5) Locate the correct diameter screw for the threaded insert.
If the screw you selected is longer than the 1/8” allowance mark on the
small straw or toothpick, as shown in Figure 2 and Figure 3, do not use
this screw. The screw length must not bypass the mark.
6) Test each size of the screws provided.
The correct screws should thread easily into the mounting point and not
pull out when tension is applied.
1˝ ¼˝
Flat Panel
Universal Washer
Universal Spacer
Mounting Bracket
Mount Point
Mounting Screw
Premier Mounts’ Universal Spacers allow you to attach the mounting bracket
panel.
The Universal Spacers must be stacked and oriented as shown.
The Universal Spacers must only be installed between the mounting
Universal Spacer Installation
premiermounts.com | p. 800.368.9700 | e. [email protected]
Cette section exige deux personnes.
Éviter de relâcher votre écran plat jusqu’à ce que vous vous
assuriez que les crochets de haut et de bas de tous les
deux supports de montage sont bien posés sur les rails de
montage hauts et bas de la sablière.
Page 10
14
15
Installation Guide
Installationsanleitung, Guía de Instalaon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
This section requires two people.
and bottom hooks of both mounting brackets are securely
seated on the upper and lower mounting rails of the wall
panel.
1)
the wall panel.
2)
3) Engage the top and bottom mounting brackets to the rails of the
wall plate.
Universal Washer Installation
Attaching the Flat Panel to the Mount
M8
M6
M5
M4
Premier Mounts’ Universal Washers are designed to accommodate the
The Universal Washer must be installed between the head of
the mounting screw and the mounting bracket as shown.
Éviter de trop serrer le dispositif de montage.
1)
2) Identify the number and location of the thread inserts on the back
3) Aligning the holes on each mounting bracket with the thread
4)
minimum of two (2) screws per bracket.
Do not overtighten the mounting hardware.
premiermounts.com | p. 800.368.9700 | e. [email protected]
Les boutons de molettes de sécurité maintiennent le panneau plat
d'être accidentellement délogé du CTM-MS3.
Page 11
17
16
Installation Guide
Installationsanleitung, Guía de Instalaon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
If the safety knurl knobs were previously installed, they must be
removed prior to installing the Panelock™ hardware.
Be sure that the Panelock™ is facing in the same direction as
shown in the illustration to the right.
1) Slide the Panelock™ onto the top mounting rail, placing the
2) Insert and tighten one (1) M6 x 12mm screw to attach the
Repeat steps 1 and 2 to attach the remaining Panelock™.
If you chose not to install the safety knurl knobs and instead chose to use
the Panelock, skip this section and proceed to the Panelock Installation
section below.
The Panelock is a theft deterrent device. It comes with security
hardware that requires a special tool that is used to install and
remove the security head screws.
dislodged from the CTM-MS3.
1)
2) Install and tighten a safety knurl knob at the top of one of the
mounting brackets.
3) Repeat steps 1 and 2 for the other safety knurl knob.
Safety Knurl Knob
(1 per Bracket)
Panelock
Hook
Security Head
Wrench
M6 x 12mm
Security Head
Screw
Panelock
Hook
Security Head
Wrench
Safety Knurl Knob Installation
Panelock™ Installation
premiermounts.com | p. 800.368.9700 | e. [email protected]
Éviter de trop serrer les vis de blocage.
Les boutons de molettes de sécurité maintiennent le panneau plat
d'être accidentellement délogé du CTM-MS3.
Page 12
19
18
Installation Guide
Installationsanleitung, Guía de Instalaon, Guida de Installazione, Guide dInstallation, Installatie gids
CTM-MS3
Adjusting the Flat Panel Friction Tilt Angle
1)
2)
3)
panel away from you.
Adjusting the Flat Panel to the Original Position
1)
2)
3)
towards the wall while the lower hand gently pulls the bottom of
dislodged from the CTM-MS3.
1) Thread an M6 x 30mm locking safety screw at the bottom of one
of the mounting brackets.
2) Use a Phillips head screwdriver to tighten the locking safety
screw.
3) Repeat steps 1 and 2 for the other locking safety screw.
Do not overtighten the locking safety screws.
M6 x 30mm
Locking Safety Screw
(1 per Bracket)
Locking Safety Screw Installation
Tilting Adjustment
premiermounts.com | p. 800.368.9700 | e. [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Premier Mounts CTM-MS3 Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues