Mitsubishi Electric PUZ-A18NKA7 Manuel utilisateur

Catégorie
Climatiseurs split-system
Taper
Manuel utilisateur
PUZ-A·NHA7/KA7
PUY-A·NHA7/KA7
Air-Conditioners
Français
Español
English
POUR L’INSTALLATEUR
PARA EL INSTALADOR
FOR INSTALLER
INSTALLATION MANUAL
For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing
the air-conditioner unit.
MANUEL D’INSTALLATION
Avant d’installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d’installation de l’appareil
intérieur pour une utilisation sûre et correcte.
MANUAL DE INSTALACIÓN
Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior
antes de instalar la unidad de aire acondicionado.
BG79U896H14_cover.indd 1 2021/10/08 11:49:39
001
1
Contents
1. Safety precautions .............................................. 1
2. Installation location .............................................. 3
3. Installing the outdoor unit ......................................... 4
4. Installing the refrigerant piping ..................................... 5
5. Drainage piping work ............................................ 7
6. Electrical work .................................................. 7
7. Test run ....................................................... 9
8. Special functions ............................................... 10
9. System control (Fig. 9-1) ......................................... 11
10. Low ambient cooling ............................................ 11
1. Safety precautions
Before installing the unit, make sure you read all the “Safety precau-
tions”.
Please report to or take consent by the supply authority before connec-
tion to the system.
After installation work has been completed, explain the “Safety precautions,”
use,and maintenance of the unit to the customer according to the information in the
Operation Manual and perform the test run to ensure normal operation. Both the
Installation Manual and Operation Manual must be given to the user for keeping.
These manuals must be passed on to subsequent users.
: Indicates a part which must be grounded.
Warning:
Carefully read the labels afxed to the main unit.
Warning:
The unit must not be installed by the user. Ask a dealer or an authorized
technician to install the unit. If the unit is installed incorrectly, water leakage,
electric shock, or re may result.
For installation work, follow the instructions in the Installation Manual and
use tools and pipe components specically made for use with R410A re-
frigerant. The R410A refrigerant in the HFC system is pressurized 1.6 times
the pressure of usual refrigerants. If pipe components not designed for
R410A refrigerant are used and the unit is not installed correctly, the pipes
may burst and cause damage or injuries. In addition, water leakage, electric
shock, or re may result.
The unit must be installed according to the instructions in order to minimize
the risk of damage from earthquakes, typhoons, or strong winds. An incor-
rectly installed unit may fall down and cause damage or injuries.
The unit must be securely installed on a structure that can sustain its weight.
If the unit is mounted on an unstable structure, it may fall down and cause
damage or injuries.
If the air conditioner is installed in a small room, measures must be taken to
prevent the refrigerant concentration in the room from exceeding the safety
limit in the event of refrigerant leakage. Consult a dealer regarding the ap-
propriate measures to prevent the allowable concentration from being ex-
ceeded. Should the refrigerant leak and cause the concentration limit to be
exceeded, hazards due to lack of oxygen in the room may result.
Ventilate the room if refrigerant leaks during operation. If refrigerant comes
into contact with a ame, poisonous gases will be released.
All electric work must be performed by a qualied technician according to
local regulations and the instructions given in this manual. The units must
be powered by dedicated power lines and the correct voltage and circuit
breakers must be used. Power lines with insufcient capacity or incorrect
electrical work may result in electric shock or re.
Use C1220 copper phosphorus, for copper and copper alloy seamless pipes,
to connect the refrigerant pipes. If the pipes are not connected correctly, the
unit will not be properly grounded and electric shock may result.
U
se only specied cables for wiring. The wiring connections must be made
securely with no tension applied on the terminal connections. Also, never
splice
the cables for wiring (unless otherwise indicated in this document).
Failure to observe these instructions may result in overheating or a re.
The terminal block cover panel of the outdoor unit must be rmly attached. If
the cover panel is mounted incorrectly and dust and moisture enter the unit,
electric shock or re may result.
When installing or relocating, or servicing the air conditioner, use only the
specified refrigerant (R410A) to charge the refrigerant lines. Do not mix it
with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high
pressure in the refrigerant line, and may result in an explosion and other
hazards.
The use of any refrigerant other than that specified for the system will
cause mechanical failure or system malfunction or unit breakdown. In the
worst case, this could lead to a serious impediment to securing product
safety.
Use only accessories authorized by Mitsubishi Electric and ask a dealer or
an authorized technician to install them. If accessories are incorrectly in-
stalled, water leakage, electric shock, or re may result.
Do not alter the unit. Consult a dealer for repairs. If alterations or repairs are
not performed correctly, water leakage, electric shock, or re may result.
The user should never attempt to repair the unit or transfer it to another loca-
tion. If the unit is installed incorrectly, water leakage, electric shock, or re
may result. If the air conditioner must be repaired or moved, ask a dealer or
an authorized technician.
After installation has been completed, check for refrigerant leaks. If refriger-
ant leaks into the room and comes into contact with the ame of a heater or
portable cooking range, poisonous gases will be released.
When opening or closing the valve below freezing temperatures, refriger-
ant may spurt out from the gap between the valve stem and the valve body,
resulting in injuries.
Do not perform pump down work when there is a gas leak. The intake of air
or other gases causes abnormally high pressure in the refrigeration cycle,
which may cause explosion or injury.
1.1. Before installation
Caution:
Do not use the unit in an unusual environment. If the air conditioner is in-
stalled in areas exposed to steam, volatile oil (including machine oil), or sul-
furic gas, areas exposed to high salt content such as the seaside, or areas
where the unit will be covered by snow, the performance can be signicantly
reduced and the internal parts can be damaged.
Do not install the unit where combustible gases may leak, be produced, ow,
or accumulate. If combustible gas accumulates around the unit, re or explo-
sion may result.
The outdoor unit produces condensation during the heating operation. Make
sure to provide drainage around the outdoor unit if such condensation is
likely to cause damage.
Warning:
Describes precautions that must be observed to prevent danger of injury or
death to the user.
Caution:
Describes precautions that must be observed to prevent damage to the unit.
When installing the unit in a hospital or communications ofce, be prepared
for noise and electronic interference. Inverters, home appliances, high-
frequency medical equipment, and radio communications equipment can
cause the air conditioner to malfunction or breakdown. The air conditioner
may also affect medical equipment, disturbing medical care, and communi-
cations equipment, harming the screen display quality.
en
BG79U896H14_01en.indd 1 2021/10/22 15:52:11
002
2
1. Safety precautions
1.3. Before electric work
Caution:
Be sure to install circuit breakers. If not installed, electric shock may result.
For the power lines, use standard cables of sufcient capacity. Otherwise, a
short circuit, overheating, or re may result.
When installing the power lines, do not apply tension to the cables. If the
connections are loosened, the cables can snap or break and overheating or
re may result.
Be sure to ground the unit. Do not connect the ground wire to gas or water
pipes, lighting rods, or telephone grounding lines. If the unit is not properly
grounded, electric shock may result.
Use circuit breakers (ground fault interrupter, isolating switch (+B fuse), and
molded case circuit breaker) with the specied capacity. If the circuit breaker
capacity is larger than the specied capacity, breakdown or re may result.
1.4. Before starting the test run
Caution:
Turn on the main power switch more than 12 hours before starting opera-
tion. Starting operation just after turning on the power switch can severely
damage the internal parts. Keep the main power switch turned on during the
operation season.
Before starting operation, check that all panels, guards and other protective
parts are correctly installed. Rotating, hot, or high voltage parts can cause
injuries.
Do not touch any switch with wet hands. Electric shock may result.
Do not touch the refrigerant pipes with bare hands during operation. The
refrigerant pipes are hot or cold depending on the condition of the owing
refrigerant. If you touch the pipes, burns or frostbite may result.
After stopping operation, be sure to wait at least ve minutes before turn-
ing off the main power switch. Otherwise, water leakage or breakdown may
result.
1.5. Using R410A refrigerant air conditioners
Caution:
Use C1220 copper phosphorus, for copper and copper alloy seamless pipes,
to connect the refrigerant pipes. Make sure the insides of the pipes are clean
and do not contain any harmful contaminants such as sulfuric compounds,
oxidants, debris, or dust. Use pipes with the specied thickness. (Refer to
page 5) Note the following if reusing existing pipes that carried R22 refriger-
ant.
- Replace the existing are nuts and are the ared sections again.
- Do not use thin pipes. (Refer to page 5)
Store the pipes to be used during installation indoors and keep both ends of
the pipes sealed until just before brazing. (Leave elbow joints, etc. in their
packaging.) If dust, debris, or moisture enters the refrigerant lines, oil dete-
rioration or compressor breakdown may result.
Use ester oil, ether oil, alkylbenzene oil (small amount) as the refrigeration
oil applied to the ared sections. If mineral oil is mixed in the refrigeration
oil, oil deterioration may result.
Do not use refrigerant other than R410A refrigerant. If another refrigerant is
used, the chlorine will cause the oil to deteriorate.
Use the following tools specically designed for use with R410A refrigerant.
The following tools are necessary to use R410A refrigerant. Contact your
nearest dealer for any questions.
Tools (for R410A)
Gauge manifold Flare tool
Charge hose Size adjustment gauge
Gas leak detector Vacuum pump adapter
Torque wrench Electronic refrigerant charging scale
Be sure to use the correct tools. If dust, debris, or moisture enters the refrig-
erant lines, refrigeration oil deterioration may result.
Do not use a charging cylinder. If a charging cylinder is used, the composi-
tion of the refrigerant will change and the efciency will be lowered.
1.2. Before installation (relocation)
Caution:
Be extremely careful when transporting the units. 2 or more persons are
needed to handle the unit, as it weighs 20 kg, 44 Ibs or more. Do not grasp
the packaging bands. Wear protective gloves to remove the unit from the
packaging and to move it, as you can injure your hands on the ns or the
edge of other parts.
• Be sure to safely dispose of the packaging materials. Packaging materials,
such as nails and other metal or wooden parts may cause stabs or other
injuries.
The base and attachments of the outdoor unit must be periodically checked
for looseness, cracks or other damage. If such defects are left uncorrected,
the unit may fall down and cause damage or injuries.
Do not clean the air conditioner unit with water. Electric shock may result.
Tighten all are nuts to specication using a torque wrench. If tightened too
much, the are nut can break after an extended period and refrigerant can
leak out.
en
BG79U896H14_01en.indd 2 2021/10/22 15:52:11
003
41-11/32
13+1-3/16
52-11/16
8-7/8
23-5/8
14-9/16
3
2.1. Refrigerant pipe (Fig. 2-1)
Check that the difference between the heights of the indoor and outdoor
units, the length of refrigerant pipe, and the number of bends in the pipe are
within the limits shown below.
Models APipe length
(one way)
BHeight
difference
C
Number of
bends (one way)
PUZ-A12, A18 Max. 30 m, 100 ft Max. 30 m, 100 ft Max. 15
PUZ-A24, A30, A36, A42 Max. 50 m, 165 ft *1 Max. 30 m, 100 ft Max. 15
PUY-A12, A18 Max. 50 m, 165 ft Max. 30 m, 100 ft Max. 15
PUY-A24, A30, A36, A42 Max. 69 m, 225 ft *1 Max. 30 m, 100 ft Max. 15
*1. If outdoor unit is connected to the A-COIL indoor unit (PAA-A18, 24, 30, 36, 42),
pipe length is “Max. 30 m, 100 ft”.
Height difference limitations are binding regardless of which unit, indoor or out-
door, is positioned higher.
D Indoor unit
E Outdoor unit
2.2. Choosing the outdoor unit installation location
Avoid locations exposed to direct sunlight or other sources of heat.
Select a location from which noise emitted by the unit will not inconvenience neigh-
bors.
Select a location permitting easy wiring and pipe access to the power source and
indoor unit.
Avoid locations where combustible gases may leak, be produced, ow, or accumu-
late.
Note that water may drain from the unit during operation.
Select a level location that can bear the weight and vibration of the unit.
Avoid locations where the unit can be covered by snow. In areas where heavy
snow fall is anticipated, special precautions such as raising the installation location
or installing a hood on the air intake must be taken to prevent the snow from block-
ing the air intake or blowing directly against it. This can reduce the airow and a
malfunction may result.
Avoid locations exposed to oil, steam, or sulfuric gas.
Use the transportation handles of the outdoor unit to transport the unit. If the unit is
carried from the bottom, hands or ngers may be pinched.
2.3. Outline dimensions (Outdoor unit) (Fig. 2-2)
Fig. 2-1
A
B
E
D
C
Fig. 2-2
31-7/8
11-13/16+29/32
24-13/16
6-3/32
19-11/16
2-15/32
13
37-13/32
13+1-3/16
37-1/8
6-7/8
23-5/8
14-9/16
A12, A18
A36, A42
(inch)
(inch)
(inch)
A24, A30
2. Installation location
en
BG79U896H14_01en.indd 3 2021/10/22 15:52:13
004
A
C
E
BA12, A18
D
A36, A42
A36, A42
14-9/16
(inch)
23-5/8 23-5/8
13
1
Min. 18-7/9
8-7/8
41-11/32
Min. 1
8-7/8
A24, A30
D
Fig. 3-1 4
2. Installation location
2.4. Ventilation and service space
2.4.1. Windy location installation
When installing the outdoor unit on a rooftop or other location unprotected from the
wind, situate the air outlet of the unit so that it is not directly exposed to strong winds.
Strong wind entering the air outlet may impede the normal airow and a malfunction
may result.
The following shows three examples of precautions against strong winds.
1 Face the air outlet towards the nearest available wall about 500 mm, 19-11/16
inch away from the wall. (Fig. 2-3)
2
Install an optional air outlet guide and air guide if the unit is installed in a location
where strong winds from a typhoon, etc. may directly enter the air outlet. (Fig. 2-4)
A Air outlet guide
3 Position the unit so that the air outlet blows perpendicularly to the seasonal wind
direction, if possible. (Fig. 2-5)
B Wind direction
Fig. 2-4
Fig. 2-3
A
Fig. 2-5
2.4.2. When installing a single outdoor unit (Refer to the last page)
Minimum dimensions are as follows, except for Max., meaning Maximum dimen-
sions, indicated.
The gures in parentheses are for A36, A42 models.
Refer to the gures for each case.
1 Obstacles at rear only (Fig. 2-6)
2 Obstacles at rear and above only (Fig. 2-7)
3 Obstacles at rear and sides only (Fig. 2-8)
* 350 mm, 13-25/32 inch for A12, A18
4 Obstacles at front only (Fig. 2-9)
* When using an optional air outlet guide, the clearance for A42 models is 500 mm,
19-11/16 inch or more.
5 Obstacles at front and rear only (Fig. 2-10)
* When using an optional air outlet guide, the clearance for A42 models is 500 mm,
19-11/16 inch or more.
6 Obstacles at rear, sides, and above only (Fig. 2-11)
* 350 mm, 13-25/32 inch for A12, A18
• Do not install the optional air outlet guides for upward airow.
2.4.3. When installing multiple outdoor units (Refer to the last page)
Leave 350 mm, 13-25/32 inch for A12, A18 and 10 mm, 13/32 inch for A24-A42
space or more between the units.
1 Obstacles at rear only (Fig. 2-12)
2 Obstacles at rear and above only (Fig. 2-13)
• No more than three units must be installed side by side. In addition, leave space as shown.
• Do not install the optional air outlet guides for upward airow.
3 Obstacles at front only (Fig. 2-14)
* When using an optional air outlet guide, the clearance for A36, A42 models is 1000 mm,
39-3/8 inch or more.
4 Obstacles at front and rear only (Fig. 2-15)
* When using an optional air outlet guide, the clearance for A36, A42 models is 1000 mm,
39-3/8 inch or more.
5 Single parallel unit arrangement (Fig. 2-16)
* When using an optional air outlet guide installed for upward airow, the clearance is 500
(1000) mm, 19-11/16 (39-3/8) inch or more.
6 Multiple parallel unit arrangement (Fig. 2-17)
* When using an optional air outlet guide installed for upward airow, the clearance is 1000
(1500) mm, 39-3/8 (59-1/16) inch or more.
7 Stacked unit arrangement (Fig. 2-18)
• The units can be stacked up to 2 units high.
• No more than two stacked units must be installed side by side. In addition, leave space as
shown.
3. Installing the outdoor unit
Be sure to install the unit in a sturdy, level surface to prevent rattling noises during
peration. (Fig. 3-1)
<Foundation specications>
Foundation bolt M10 (3/8")
Thickness of concrete 120 mm, 4-23/32 inch
Length of bolt 70 mm, 2-3/4 inch
Weight-bearing capacity 320 kg, 264 lbs
Make sure that the length of the foundation bolt is within 30 mm, 1-3/16 inch of the
bottom surface of the base.
Secure the base of the unit rmly with four-M10 foundation bolts in sturdy locations.
Installing the outdoor unit
Do not block the vent. If the vent is blocked, operation will be hindered and break-
down may result.
In addition to the unit base, use the installation holes on the back of the unit to
attach wires, etc., if necessary to install the unit. Use self-tapping screws (ø5 × 15
mm, ø13/16 × 19/32 inch or less) and install on site.
Warning:
The unit must be securely installed on a structure that can sustain its weight.
If the unit is mounted on an unstable structure, it may fall down and cause
damage or injuries.
The unit must be installed according to the instructions in order to minimize
the risk of damage from earthquakes, typhoons, or strong winds. An incor-
rectly installed unit may fall down and cause damage or injuries.
A M10 (3/8ʺ) bolt
B Base
C As long as possible.
D Vent
E Set deep in the ground.
Max. 23/32 for A12, A18
Max. 1-3/16 for A24-A42
(inch)
Fig. 3-1
A24, A30A12, A18
19-11/16 19-11/16
6-3/32 6-3/32
31-7/8
1-9/32
11-13/16
13
23-5/8 23-5/8
6-7/8 6-7/8
37-13/32
1-3/32 13
14-9/16
(inch)
Min. 25-19/32
Min. 13-25/32
Min. 14-25/32
Min. 1
en
BG79U896H14_01en.indd 4 2021/10/22 15:52:25
005
5
45˚± 2˚
A
C
D
B
øA
R1/64 to R1/32
A24-A42A12, A18
DD
AE
B
C
A Liquid pipe
B Gas pipe
C Insulation
D Taping
4. Installing the refrigerant piping
4.1.
Precautions for devices that use R410A refrigerant
Refer to page 2 for precautions not included below on using air conditioners
with R410A refrigerant.
Use ester oil, ether oil, alkylbenzene oil (small amount) as the refrigeration
oil applied to the ared sections.
Use C1220 copper phosphorus, for copper and copper alloy seamless pipes,
to connect the refrigerant pipes. Use refrigerant pipes with the thicknesses
specied in the table to the below. Make sure the insides of the pipes are
clean and do not contain any harmful contaminants such as sulfuric com-
pounds, oxidants, debris, or dust.
Warning:
When installing or relocating, or servicing the air conditioner, use only the
specied refrigerant (R410A) to charge the refrigerant lines. Do not mix it with
any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pres-
sure in the refrigerant line, and may result in an explosion and other hazards.
The use of any refrigerant other than that specied for the system will cause
mechanical failure or system malfunction or unit breakdown. In the worst
case, this could lead to a serious impediment to securing product safety.
A12, A18 A24-A42
Liquid pipe ø6.35 mm, 1/4inch
thickness 0.8 mm, 1/32 inch
ø9.52 mm, 3/8 inch
thickness 0.8 mm, 1/32 inch
Gas pipe ø12.7 mm, 1/2 inch
thickness 0.8 mm, 1/32 inch
ø15.88 mm, 5/8 inch
thickness 1.0 mm, 3/64 inch
Do not use pipes thinner than those specied above.
4.2. Connecting pipes (Fig. 4-1) (Fig. 4-2)
When commercially available copper pipes are used, inslate both the liquid and
gas pipes separately with commercially available insulation materials (heat-resist-
ant to 100 °C, 212 °F or more, thickness of 12 mm, 1/2 inch or more). (Fig. 4-1)
The indoor parts of the drain pipe should be wrapped with polyethylene foam insu-
lation materials (specic gravity of 0.03, thickness of 9 mm, 23/64 inch or more).
[Fig. 4-2]
• Apply thin layer of refrigerant oil to pipe and joint seating surface before tightening
are nut. A
Use 2 wrenches to tighten piping connections. B
Use leak detector or soapy water to check for gas leaks after connections are
completed.
Apply refrigerating machine oil over the entire are seat surface. C
Use the are nuts for the following pipe size. D
Notes:
1. The are nut is attached to its pipe.
2. The are nut is in the outdoor unit accessory.
Do not use the are nut attached. If it is used, a gas leakage or even a pipe
extraction may occur.
When bending the pipes, be careful not to break them. Bend radii of 100 mm,
3-15/16 inch to 150 mm, 5-27/32 inch are sufcient.
Make sure the pipes do not contact the compressor. Abnormal noise or vibration
may result.
1 Pipes must be connected starting from the indoor unit.
Flare nuts must be tightened with a torque wrench.
2 Flare the liquid pipes and gas pipes and apply a thin layer of refrigeration oil
(Applied on site).
Warning:
When installing the unit, securely connect the refrigerant pipes before starting
the compressor.
4.3. Refrigerant piping (Fig. 4-3)
For A12, A18
Remove the service panel D (2 screws).
For A24-A42
Remove the service panel D (3 screws) and the front piping cover A (2 screws)
and rear piping cover B (2 screws:PUZ(Y)-A24, A30NHA7) (4 screws:PUZ(Y)-A36,
A42NKA7).
1 Perform refrigerant piping connections for the indoor/outdoor unit when the out-
door unit’s stop valve is completely closed.
2 Vacuum-purge air from the indoor unit and the connection piping.
3 After connecting the refrigerant pipes, check the connected pipes and the indoor
unit for gas leaks. (Refer to 4.4 Refrigerant pipe airtight testing method)
4 Vacuumize the refrigerant lines through the service port of the liquid stop valve
and then open the stop valves completely (for both the liquid and gas stop valves).
This will completely connect the refrigerant lines of the indoor and outdoor units.
• If the stop valves are left closed and the unit is operated, the compressor and
control valves will be damaged.
Use a leak detector or soapy water to check for gas leaks at the pipe connection
sections of the outdoor unit.
• Do not use the refrigerant from the unit to purge air from the refrigerant lines.
• After the valve work is completed, tighten the valve caps to the correct torque:
20 to 25 N·m, 14 to 18 ft·lbs (200 to 250 kgf·cm).
Failure to replace and tighten the caps may result in refrigerant leakage. In addi-
tion, do not damage the insides of the valve caps as they act as a seal to prevent
refrigerant leakage.
5 Use sealant to seal the ends of the thermal insulation around the pipe connection
sections to prevent water from entering the thermal insulation.
A (Fig. 4-1)
Copper pipe O.D. Flare dimensions
øA dimensions
(mm) (inch) (mm) (inch)
ø6.35 1/4” 8.7 - 9.1 11/32 - 23/64
ø9.52 3/8” 12.8 - 13.2 1/2 - 33/64
ø12.7 1/2” 16.2 - 16.6 41/64 - 21/32
ø15.88 5/8” 19.3 - 19.7 49/64 - 25/32
B (Fig. 4-1)
Copper pipe O.D. Flare nut O.D. Tightening torque
(mm) (inch) (mm) (inch) (N·m) (ft·lbs)
ø6.35 1/4” 17 43/64 14 - 18 10 - 13
ø9.52 3/8” 22 7/8 34 - 42 25 - 30
ø12.7 1/2” 26 1 - 3/64 49 - 61 35 - 44
ø15.88 5/8” 29 1 - 9/64 68 - 82 49 - 59
A
B
C
D
Fig. 4-1
Fig. 4-2
A12, A18 A24 - A42
Gas side Pipe size (mm, inch) ø12.7, 1/2” ø15.88, 5/8”
Liquid side Pipe size (mm, inch) ø6.35, 1/4” ø9.52, 3/8”
A Flare cutting dimensions
B Flare nut tightening torque
90˚± 0.5˚
A Front piping cover
B Piping cover
C Stop valve
D Service panel
E Bend radius : 100 mm, 3-15/16 inch-150 mm, 5-27/32 inch
Fig. 4-3
(inch)
en
BG79U896H14_01en.indd 5 2021/10/22 15:52:27
006
6
4. Installing the refrigerant piping
4.4. Refrigerant pipe airtight testing method
(1) Connect the testing tools.
• Make sure the stop valves
A
B
are closed and do not open them.
• Add pressure to the refrigerant lines through the service port
C
of the liquid stop valve
D
.
(2) Do not add pressure to the specied pressure all at once; add pressure little by little.
1
Pressurize to 0.5 MPa (5 kgf/cm2G), wait 5 minutes, and make sure the pressure does
not decrease.
2
Pressurize to 1.5 MPa (15 kgf/cm2G), wait 5 minutes, and make sure the pressure does
not decrease.
3
Pressurize to 4.15 MPa (41.5 kgf/cm2G) and measure the surrounding temperature and
refrigerant pressure.
(3) If the specied pressure holds for about one day and does not decrease, the pipes have
passed the test and there are no leaks.
• If the surrounding temperature changes by 1 °C, the pressure will change by about 0.03
MPa (0.3 kgf/cm2G). Make the necessary corrections.
(4) If the pressure decreases in steps (2) or (3), there is a gas leak. Look for the source of
the gas leak.
4.5. Stop valve opening method (Fig. 4-5)
1 Remove the cap and turn the valve rod counterclockwise as far as it will go with the
use of a 4 mm, 5/32 inch hexagonal wrench. Stop turning when it hits the stopper.
(ø6.35, 1/4 inch: Approximately 4.5 revolutions) (ø9.52, 3/8 inch: Approximately
10 revolutions)
2 Make sure that the stop valve is open completely, push in the handle and rotate
he cap back to its original position.
A Valve
B Unit side
C Operation section
D Cap
E Local pipe side
F Pipe cover
G Service port
H Wrench hole
Refrigerant pipes are protectively wrapped for A24-A42
The pipes can be protectively wrapped up to a diameter of ø90 mm, 3-35/64 inch
before or after connecting the pipes. Cut out the knockout in the pipe cover follow-
ing the groove and wrap the pipes.
Pipe inlet gap for A24-A42
Use putty or sealant to seal the pipe inlet around the pipes so that no gaps remain.
(If the gaps are not closed, noise may be emitted or water and dust will enter the
unit and breakdown may result.)
I Double spanner section
(Do not apply a spanner other than to this sec-
tion. Doing so would cause refrigerant leaks.)
J Seal section
(Seal the end of the heat insulation material at
the pipe connection section with whatever seal
material you have on hand so that water does
not inltrate the heat insulation material.)
K Handle
Precautions when using the charge valve (Fig. 4-6)
Do not tighten the service port too much when installing it, otherwise, the valve core
could be deformed and become loose, causing a gas leak.
After positioning section B in the desired direction, turn section A only and tighten it.
Do not further tighten sections A and B together after tightening section A.
Warning:
When opening or closing the valve below freezing temperatures, refrigerant
may spurt out from the gap between the valve stem and the valve body, result-
ing in injuries.
A
B
H
I
C
D
E
F
G
D
B
A
C
Fig. 4-4
D
G
B
A
I
F
E
J
H
Fig. 4-5
c
B
A
D
Fig. 4-6
Notes:
1. The gure to the left is an example only.
The stop valve shape, service port po-
sition, etc., may vary according to the
model.
2. Turn section A only.
(Do not further tighten sections A and
B together.)
C Charge hose
D Service port
A Stop valve <Liquid side>
B Stop valve <Gas side>
C Service port
D Open/Close section
E Local pipe
F Sealed, same way for gas side
G Pipe cover
H Do not use a wrench here.
Refrigerant leakage may result.
I Use 2 wrenches here.
en
BG79U896H14_01en.indd 6 2021/10/22 15:52:27
007
7
5. Drainage piping work
Outdoor unit drainage pipe connection
When drain piping is necessary, use the drain socket or the drain pan (option).
A12, A18 A24, A30 A36, A42
Drain socket PAC-SJ08DS-E PAC-SG61DS-E
Drain pan PAC-SG63DP-E PAC-SG64DP-E PAC-SH97DP-E
6. Electrical work
6.1. Outdoor unit (Fig. 6-1, Fig. 6-2)
1 Remove the service panel.
2 Wire the cables referring to the Fig. 6-1 and the Fig. 6-2.
Fig. 6-1
Fig. 6-2
A12, A18
A
C
C
E
E
EE E
S3
S3
S2
S1
S2S1L1 L2
GR
A
B
B
D
D
A
A24-A42
E
B
A
F
C
L1
GR
L2 S1 S2 S3
A
B
C
DE
L1
GR
L2 S1 S2 S3
A Indoor unit
B Outdoor unit
C Remote controller
D Main switch (Breaker)
E Earth
A Earth terminal
B Terminal block
C Clamp
D Service panel
For Power
For Power
4.6. Addition of refrigerant
• Additional charging is not necessary if the pipe length does not exceed 21 m, 70 ft
for A12-A30, 30 m 100 ft for A36, A42.
• Especially, additional charging is not necessary if the pipe length does not exceed
30 m 100 ft for A24, 30, 36, A42 connected to the A-COIL indoor unit (PAA-A18,
24, 30, 36, 42).
If the pipe length exceeds the specied length above, charge the unit with additional
R410A refrigerant according to the permitted pipe lengths in the chart below.
Notes:
1. When the unit is stopped, charge the unit with the additional refrigerant through
the liquid stop valve after the pipe extensions and indoor unit have been vacu-
umized.
When the unit is operating, add refrigerant to the gas check valve using a
safety charger. Do not add liquid refrigerant directly to the check valve.
2. After charging the unit with refrigerant, note the added refrigerant amount on
the service label (attached to the unit).
Refer to the “1.5. Using R410A refrigerant air conditioners” for more informa-
tion.
• Be careful when installing multiple units. Connecting to an incorrect indoor unit
can lead to abnormally high pressure and have a serious effect on operation per-
formance.
Model Max pipe
length
Max height
difference
Additional refrigerant charging amount (kg/oz) *2
21 m
70 ft
24 m
80 ft
27 m
90 ft
30 m
100 ft
34 m
110 ft
37 m
120 ft
40 m
130 ft
43 m
140 ft
46 m
150 ft
49 m
160 ft
50 m
165 ft
52 m
170 ft
55 m
180 ft
58 m
190 ft
61 m
200 ft
64 m
210 ft
67 m
220 ft
69 m
225 ft
PUZ-A12, 18
30 m, 100 ft
30 m, 100 ft 0
0.06 kg
2 oz
0.11 kg
4 oz
0.17 kg
6 oz
--------------
PUZ-A24, 30
50 m, 165 ft *1
30 m, 100 ft 0
0.20 kg
7 oz
0.40 kg
14 oz
0.60 kg
21 oz
0.79 kg
28 oz
0.99 kg
35 oz
1.19 kg
42 oz
1.39 kg
49 oz
1.59 kg
56 oz
1.79 kg
63 oz
1.89 kg
67 oz
-------
PUZ-A36, 42
50 m, 165 ft *1
30 m, 100 ft 0 0 0 0
0.20 kg
7 oz
0.40 kg
14 oz
0.26 kg
21 oz
0.79 kg
28 oz
0.99 kg
35 oz
1.19 kg
42 oz
1.29 kg
46 oz
-------
PUY-A12, 18
50 m, 165 ft
30 m, 100 ft 0
0.03 kg
1 oz
0.06 kg
2 oz
0.09 kg
3 oz
0.11 kg
4 oz
0.14 kg
5 oz
0.17 kg
6 oz
0.20 kg
7 oz
0.23 kg
8 oz
0.26 kg
9 oz
0.27 kg
10 oz
-------
PUY-A24, 30
69 m, 225 ft *1
30 m, 100 ft 0
0.09 kg
3 oz
0.17 kg
6 oz
0.26 kg
9 oz
0.34 kg
12 oz
0.43 kg
15 oz
0.51 kg
18 oz
0.60 kg
21 oz
0.68 kg
24 oz
0.77 kg
27 oz
0.81 kg
29 oz
0.85 kg
30 oz
0.94 kg
33 oz
1.02 kg
36 oz
1.11 kg
39 oz
1.19 kg
42 oz
1.28 kg
45 oz
1.32 kg
47 oz
PUY-A36, 42
69 m, 225 ft *1
30 m, 100 ft 0 0 0 0
0.09 kg
3 oz
0.17 kg
6 oz
0.26 kg
9 oz
0.34 kg
12 oz
0.43 kg
15 oz
0.51 kg
18 oz
0.55 kg
20 oz
0.60 kg
21 oz
0.68 kg
24 oz
0.77 kg
27 oz
0.85 kg
30 oz
0.94 kg
33 oz
1.02 kg
36 oz
1.06 kg
38 oz
*1. If outdoor unit is connected to the A-COIL indoor unit (PAA-A18, 24, 30, 36, 42), pipe length is “Max. 30 m, 100 ft”.
*2. This additional refrigerant chart is used only when connected to an indoor unit other than A-COIL indoor unit (PAA-A18, 24, 30, 36, 42). Additional charging is not necessary
if the pipe length does not exceed 30 m 100 ft for A24, 30, 36, A42 connected to the A-COIL indoor unit (PAA-A18, 24, 30, 36, 42).
4. Installing the refrigerant piping
E Wire the cables so that they do not
contact the center of the service panel
or the gas valve.
en
BG79U896H14_01en.indd 7 2021/10/22 15:52:28
008
8
A12, A18
A24-A42
TERMINAL BED
CABLE STRAP
CORD COVER
CONDUIT COVER
SERVICE PANEL
CONDUIT PLATE : accessory
6. Electrical work
en
BG79U896H14_01en.indd 8 2021/10/22 15:52:30
009
S1
S2
S3
S1
S2
S3
208/230V
9
6. Electrical work
Warning:
In case of A-control wiring, there is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between power
line and communication signal line. Therefore, please turn off the main power supply when servicing. And do not touch the S1, S2, S3 terminals when the power
is energized. If isolator should be used between indoor unit and outdoor unit, please use 3-pole type.
7. Test run
7.1. Before test run
After completing installation and the wiring and piping of the indoor and
outdoor units, check for refrigerant leakage, looseness in the power supply
or control wiring, wrong polarity, and no disconnection of one phase in the
supply.
Use a 500-volt megohmmeter to check that the resistance between the pow-
er supply terminals and ground is at least 1 MΩ.
Do not carry out this test on the control wiring (low voltage circuit) terminals.
Warning:
Do not use the air conditioner if the insulation resistance is less than 1 MΩ.
Insulation resistance
After installation or after the power source to the unit has been cut for an extended
period, the insulation resistance will drop below 1 MΩ due to refrigerant accumulat-
ing in the compressor. This is not a malfunction. Perform the following procedures.
1. Remove the wires from the compressor and measure the insulation resistance of
the compressor.
2. If the insulation resistance is below 1 MΩ, the compressor is faulty or the resist-
ance dropped due the accumulation of refrigerant in the compressor.
3. After connecting the wires to the compressor, the compressor will start to warm
up after power is supplied. After supplying power for the times indicated below,
measure the insulation resistance again.
• The insulation resistance drops due to accumulation of refrigerant in the com-
pressor. The resistance will rise above 1 MΩ after the compressor is warmed up
for 12 hours.
(The time necessary to warm up the compressor varies according to atmos-
pheric conditions and refrigerant accumulation.)
• To operate the compressor with refrigerant accumulated in the compressor, the
compressor must be warmed up at least 12 hours to prevent breakdown.
4. If the insulation resistance rises above 1 MΩ, the compressor is not faulty.
Caution:
• The compressor will not operate unless the power supply phase connection
is correct.
• Turn on the power at least 12 hours before starting operation.
- Starting operation immediately after turning on the main power switch can result
in severe damage to internal parts. Keep the power switch turned on during the
operational season.
6.2. Field electrical wiring
Outdoor unit model A12 A18 A24 A30 A36 A42
Outdoor unit power supply
~/N (single), 60Hz,
208/230 V
~/N (single), 60Hz,
208/230 V
~/N (single), 60Hz,
208/230 V
~/N (single), 60Hz,
208/230 V
~/N (single), 60Hz,
208/230 V
~/N (single), 60Hz,
208/230 V
Outdoor unit input capacity Main switch (Breaker) *1 15 A 15 A 25 A 25 A 30 A 30 A
Wiring Wire
No. x
size (mm2)
Outdoor unit power supply 2 x Min. AWG 14 2 × Min. AWG 14 2 × Min. AWG 12 2 × Min. AWG 12 2 × Min. AWG 10 2 × Min. AWG 10
Indoor unit-Outdoor unit *2 3 x AWG 14 (polar) 3 x AWG 14 (polar) 3 x AWG 14 (polar) 3 x AWG 14 (polar) 3 x AWG 14 (polar) 3 x AWG 14 (polar)
Indoor unit-Outdoor unit earth *2
1 x Min. AWG 14 (polar) 1 x Min. AWG 14 (polar)
1 x Min. AWG 14 (polar)
1 x Min. AWG 14 (polar) 1 x Min. AWG 14 (polar) 1 x Min. AWG 14 (polar)
Remote controller-Indoor unit *3
2 × AWG 22 (Non-polar) 2 x AWG 22 (Non-polar) 2 x AWG 22 (Non-polar) 2 x AWG 22 (Non-polar) 2 x AWG 22 (Non-polar) 2 x AWG 22 (Non-polar)
Circuit
rating
Outdoor unit L1-L2 (single) *4 208/230 V AC 208/230 V AC 208/230 V AC 208/230 V AC 208/230 V AC 208/230 V AC
Indoor unit-Outdoor unit S1-S2 (single) *4 208/230 V AC 208/230 V AC 208/230 V AC 208/230 V AC 208/230 V AC 208/230 V AC
Indoor unit-Outdoor unit S2-S3 (single) *4 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
Remote controller-Indoor unit *4 12 V DC 12 V DC 12 V DC 12 V DC 12 V DC 12 V DC
*1. Please follow applicable federal, state, or local codes to prevent potential leakage/electric shock. Or install a ground fault interrupt for the prevention of leakage and elec-
tric shock.
*2. Max. 50 m, 164 ft
S3 separated, Max. 80 m, 262 ft
*3. The 10 m, 30 ft wire is attached in the remote controller accessory.
*4. The gures are NOT always against the ground.
S3 terminal has DC 24 V against S2 terminal. However between S3 and S1, these terminals are NOT electrically insulated by the transformer or other device.
Notes: 1. Wiring size must comply with the applicable local and national code.
2.
Power supply cords, the Indoor-Outdoor connecting cable and the water heater-Outdoor connecting cable shall not be lighter than polychloroprene
sheathed exible cord. (Design 60245 IEC 57
)
3. Use an earth wire which is longer than the other cords so that it will not become disconnected when tension is applied.
Never splice the power cable or the indoor-outdoor connection cable, otherwise it may result in a smoke, a re or communication failure.
Single phase
A-Control
Outdoor Unit
A-Control
Indoor Unit
Isolator 3 poles isolator
en
BG79U896H14_01en.indd 9 2021/10/22 15:52:31
010
A
SW1
Orange
1
3
Brown
Red
EB
F
CNDM
X
X
C D
10
8. Special functions
8.1. Low noise mode (on-site modication) (Fig. 8-1)
By performing the following modication, operation noise of the outdoor unit can be
reduced by about 3-4 dB.
The low noise mode will be activated when a commercially available timer or the
contact input of an ON/OFF switch is added to the CNDM connector (option) on the
control board of the outdoor unit.
• The ability varies according to the outdoor temperature and conditions, etc.
1 Complete the circuit as shown when using the external input adapter
(PAC-SC36NA-E). (Option)
2 SW7-1 (Outdoor unit control board): OFF
3 SW1 ON: Low noise mode
SW1 OFF: Normal operation
A Circuit diagram example (low noise mode)
B On-site arrangement
C External input adapter (PAC-SC36NA-E)
X: Relay
8.3. Refrigerant collecting (pump down)
Perform the following procedures to collect the refrigerant when moving the indoor
unit or the outdoor unit.
1 Supply power (circuit breaker).
When power is supplied, make sure that “CENTRALLY CONTROLLED” is not
displayed on the remote controller. If “CENTRALLY CONTROLLED” is dis-
played, the refrigerant collecting (pump down) cannot be completed normally.
Start-up of the indoor-outdoor communication takes about 3 minutes after the
power (circuit breaker) is turned on. Start the pump-down operation 3 to 4 min-
utes after the power (circuit breaker) is turned ON.
2 After the liquid stop valve is closed, set the SWP switch on the control board of the
outdoor unit to ON. The compressor (outdoor unit) and fans (indoor and outdoor
units) start operating and refrigerant collecting operation begins. LED1 and LED2
on the control board of the outdoor unit are lit.
Only set the SWP switch (push-button type) to ON if the unit is stopped. How-
ever, even if the unit is stopped and the SWP switch is set to ON less than 3
minutes after the compressor stops, the refrigerant collecting operation cannot
be performed. Wait until compressor has been stopped for 3 minutes and then
set the SWP switch to ON again.
Fig. 8-1
3 Because the unit automatically stops in about 2 to 3 minutes when the refrigerant
collecting operation is completed (LED1 off, LED2 lit), be sure to quickly close
the gas stop valve. If LED1 is lit and LED 2 is off and the outdoor unit is stopped,
refrigerant collection is not properly performed. Open the liquid stop valve com-
pletely, and then repeat step 2 after 3 minutes have passed.
If the refrigerant collecting operation has been completed normally (LED1 off,
LED2 lit), the unit will remain stopped until the power supply is turned off.
4 Turn off the power supply (circuit breaker).
Note that when the extension piping is very long with large refrigerant amount,
it may not be possible to perform a pump-down operation. When performing the
pump-down operation, make sure that the low pressure is lowered to near 0
MPa (gauge).
Warning:
When pumping down the refrigerant, stop the compressor before disconnect-
ing the refrigerant pipes. The compressor may burst if air etc. get into it.
Do not perform pump down work when there is a gas leak. The intake of air
or other gases causes abnormally high pressure in the refrigeration cycle,
which may cause explosion or injury.
A Circuit diagram example
(Demand function)
B On-site arrangement
X, Y: Relay
8.2. Demand function (on-site modication) (Fig. 8-2)
By performing the following modication, energy consumption can be reduced to
0–100% of the normal consumption.
The demand function will be activated when a commercially available timer or the
contact input of an ON/OFF switch is added to the CNDM connector (option) on the
control board of the outdoor unit.
1 Complete the circuit as shown when using the external input adapter
(PAC-SC36NA-E). (Option)
2 By setting SW7-1 on the control board of the outdoor unit, the energy consump-
tion (compared to the normal consumption) can be limited as shown below.
SW7-1 SW2 SW3 Energy consumption
Demand
function ON
OFF OFF 100%
ON OFF 75%
ON ON 50%
OFF ON 0% (Stop)
Fig. 8-2
The followings must be checked as well.
• The outdoor unit is not faulty. LED1 and LED2 on the control board of the outdoor
unit ash when the outdoor unit is faulty.
• Both the gas and liquid stop valves are completely open.
A protective sheet covers the surface of the DIP switch panel on the control board
of the outdoor unit. Remove the protective sheet to operate the DIP switches easily.
7. Test run
D Outdoor unit control board
E Max. 10 m, 33 ft
F Power supply for relay
C External input adapter
(PAC-SC36NA-E)
D Outdoor unit control board
E Max. 10 m, 33 ft
F Power supply for relay
7.2. Test run
7.2.1. Using SW4 in outdoor unit
1) PUZ Type
SW4-1 ON Cooling operation
SW4-2 OFF
SW4-1 ON Heating operation
SW4-2 ON
2) PUY Type
SW4-1 ON Cooling operation
SW4-2 ON or OFF
* After performing the test run, set SW4-1 to OFF.
After power is supplied, a small clicking noise may be heard from the inside of the
outdoor unit. The electronic expansion valve is opening and closing. The unit is
not faulty.
A few seconds after the compressor starts, a clanging noise may be heard from
the inside of the outdoor unit. The noise is coming from the check valve due to the
small difference in pressure in the pipes. The unit is not faulty.
The test run operation mode cannot be changed by DIP switch SW4-2 during
the test run. (To change the test run operation mode during the test run, stop
the test run by DIP switch SW4-1. After changing the test run operation mode,
resume the test run by switch SW4-1.)
7.2.2. Using remote controller
Refer to the indoor unit installation manual.
• Make sure that the all of the SW5 DIP switches for function changes on the control
board of the outdoor unit are set to OFF. If all of the SW5 switches are not set to
OFF, record the settings and then set all of the switches to OFF. Begin recovering
the refrigerant. After moving the unit to a new location and completing the test run,
set the SW5 switches to the previously recorded settings.
A
SW2 SW3
Orange
1
3
Brown
Red
CNDM
Y
X
XY
F
BE
C D
en
BG79U896H14_01en.indd 10 2021/10/22 15:52:31
011
11
123456
Set the refrigerant address using the DIP switch of the outdoor unit.
1 Wiring from the Remote Control
This wire is connected to TB5 (terminal board for remote controller) of the indoor
unit (non-polar).
2 When a Different Refrigerant System Grouping is Used.
Up to 16 refrigerant systems can be controlled as one group using the slim MA
remote controller.
Note:
In single refrigerant system (twin), there is no need of wiring 2.
A Outdoor unit
B Indoor unit
C Master remote controller
D Subordinate remote controller
E Standard 1:1 (Refrigerant address = 00)
F
Simultaneous twin (Refrigerant address = 01)
G
Simultaneous twin (Refrigerant address = 02)
E SW 1 - 3 ~ 6
F SW 1 - 3 ~ 6
G SW 1 - 3 ~ 6
9. System control (Fig. 9-1)
Fig. 9-1
SW1
Function table
<SW1>
Function Operation according to switch setting
ON OFF
SW1
function
settings
1 Compulsory
defrosting Start Normal
2 Error history
clear Clear Normal
3
4
5
6
Refrigerant
system ad-
dress setting
Settings for outdoor unit addresses
0 to 15
TB1
A GFAA E
B B B B B
D
C
TB1 TB1
TB4
TB5
TB4
TB5
TB4 TB4
TB5
TB4
1
1
2
ON
OFF
ON
OFF
ON
OFF
3 4 5 6
3 4 5 6
3 4 5 6
ON
OFF
2
10. Low ambient cooling
Precautions for low ambient cooling
If the outdoor temperature is 23 °F or lower during cooling operation, install an optional air guide to prevent wind from blowing into the outdoor unit.
Install the outdoor unit in a location where wind will not blow onto the back of the unit.
To prevent damage to the parts, be sure to install the unit, turn on the main power, and perform service in an environment where the ambient temperature is 0 °F or higher.
In order to protect the compressor and electrical components, do not turn off the circuit breaker if the unit is installed in an environment where the ambient temperature is 0
°F or lower.
It needs at least 12hr standby to operation in order to warm the electrical parts.
en
BG79U896H14_01en.indd 11 2021/10/22 15:52:31
012
1
fr
Index
1. Consignes de sécurité
Avant d’installer le climatiseur, lire attentivement toutes les “Consignes
de sécurité”.
Veuillez consulter ou obtenir la permission votre compagnie d’électricité
avant de connecter votre système.
Une fois l’installation terminée, expliquer les “Consignes de sécurité”, l’utilisation et
l’entretien de l’appareil au client conformément aux informations du mode d’emploi
et effectuer l’essai de fonctionnement en continu pour garantir un fonctionnement
normal. Le manuel d’installation et le mode d’emploi doivent être fournis à l’utilisa-
teur qui doit les conserver. Ces manuels doivent également être transmis aux nou-
veaux utilisateurs.
: Indique un élément qui doit être mis à la terre.
Avertissement:
Prendre soin de lire les étiquettes se trouvant sur l’appareil principal.
Avertissement:
L’appareil ne doit pas être installé par l’utilisateur. Contacter un revendeur
ou un technicien agréé pour installer l’appareil. Si l’appareil n’est pas cor-
rectement installé, des fuites d’eau, des chocs électriques ou des incendies
peuvent se produire.
Pour l’installation, respecter les instructions du manuel d’installation et uti-
liser des outils et des composants de tuyau spécialement conçus pour une
utilisation avec le réfrigérant R410A. La pression du réfrigérant R410A du
système HFC est 1,6 fois supérieure à celle des réfrigérants traditionnels.
Si des composants de tuyau non adaptés au réfrigérant R410A sont utilisés
et si l’appareil n’est pas correctement installé, les tuyaux peuvent éclater et
provoquer des dommages ou des blessures. Des fuites d’eau, des chocs
électriques et des incendies peuvent également se produire.
L’appareil doit être installé conformément aux instructions pour réduire les
risques de dommages liés à des tremblements de terre, des typhons ou des
vents violents. Une installation incorrecte peut entraîner la chute de l’appa-
reil et provoquer des dommages ou des blessures.
L’appareil doit être solidement installé sur une structure pouvant supporter
son poids. Si l’appareil est xé sur une structure instable, il risque de tomber
et de provoquer des dommages ou des blessures.
Si le climatiseur est installé dans une petite pièce, certaines mesures doi-
vent être prises pour éviter que la concentration de réfrigérant ne dépasse
le seuil de sécurité en cas de fuite. Consulter un revendeur pour obtenir les
mesures adéquates et ainsi éviter de dépasser la concentration autorisée.
En cas de fuite de réfrigérant et de dépassement du seuil de concentration,
des risques liés au manque d’oxygène dans la pièce peuvent survenir.
Aérer la pièce en cas de fuite de réfrigérant lors de l’utilisation. Le contact
du réfrigérant avec une amme peut provoquer des émanations de gaz toxi-
ques.
Toutes les installations électriques doivent être effectuées par un technicien
qualié conformément aux réglementations locales et aux instructions four-
nies dans ce manuel. Les appareils doivent être alimentés par des lignes
électriques adaptées. Utiliser la tension correcte et des coupe-circuits. Des
lignes électriques de capacité insufsante ou des installations électriques
incorrectes peuvent provoquer un choc électrique ou un incendie.
Utiliser le cuivre phosphoreux C1220, pour des tuyaux sans soudure en cui-
vre et en alliage de cuivre, pour raccorder les tuyaux de réfrigérant. Si les
tuyaux ne sont pas correctement raccordés, la mise à la terre de l’appareil
ne sera pas conforme et des chocs électriques peuvent se produire.
N’utiliser que les câbles spéciés pour les raccordements. Les raccorde-
ments doivent être réalisés correctement sans tension sur les bornes. Ne
jamais effectuer de jonction sur les câbles (sauf en cas d’indications contrai-
res). Le non respect de cette consigne peut entraîner une surchauffe ou un
incendie.
Le couvercle du bloc de sortie de l’appareil extérieur doit être solidement
xé. S’il n’est pas correctement installé et si des poussières et de l’humidité
s’inltrent dans l’appareil, un choc électrique ou un incendie peut se pro-
duire.
Lors de l’installation, du déplacement ou de l’entretien du climatiseur, n’utili-
sez que le réfrigérant spécié (R410A) pour remplir les tuyaux de réfrigérant.
Ne pas le mélanger avec un autre réfrigérant et faire le vide d’air dans les
tuyaux.
Si du réfrigérant est mélangé avec de l’air, cela peut provoquer des poin-
tes de pression dans les tuyaux de réfrigérant et entraîner une explosion et
d’autres risques.
L’utilisation d’un réfrigérant différent de celui spécié pour le climatiseur
peut entraîner des défaillances mécaniques, des dysfonctionnements du
système ou une panne de l’appareil. Dans le pire des cas, cela peut entraîner
un obstacle à la mise en sécurité du produit.
N’utiliser que les accessoires agréés par Mitsubishi Electric et contacter un
revendeur ou un technicien agréé pour les installer. Si les accessoires ne
sont pas correctement installés, une fuite d’eau, un choc électrique ou un
incendie peut se produire.
Ne pas changer l’appareil. Consulter un revendeur en cas de réparations. Si
les modications ou réparations ne sont pas correctement effectuées, une
fuite d’eau, un choc électrique ou un incendie peut se produire.
L’utilisateur ne doit jamais essayer de réparer ou de déplacer l’appareil. Si
l’appareil n’est pas correctement installé, des fuites d’eau, des chocs électri-
ques ou des incendies peuvent se produire. Si le climatiseur doit être réparé
ou déplacé, contacter un revendeur ou un technicien agréé.
Une fois l’installation terminée, vérier les éventuelles fuites de réfrigérant.
Si le réfrigérant fuit dans la pièce et entre en contact avec la amme d’un
chauffage ou d’une cuisinière, des gaz toxiques peuvent se dégager.
Lors de l’ouverture ou de la fermeture de la vanne sous des températures de
congélation, le réfrigérant peut jaillir de l’espace entre la tige de vanne et le
corps de vanne et provoquer des blessures.
Ne pas purger s’il y a une fuite de gaz. L’arrivée d’air ou d’autres gaz pro-
voque une pression anormalement élevée dans le cycle de réfrigération, ce
qui peut provoquer une explosion ou des blessures.
1.1. Avant l’installation
Précaution:
Ne pas utiliser l’appareil dans un environnement inhabituel. Si le climati-
seur est installé dans des endroits exposés à la vapeur, à l’huile volatile
(notamment l’huile de machine), au gaz sulfurique, à une forte teneur en sel,
par exemple, à la mer, ou dans des endroits où l’appareil sera recouvert de
neige, les performances peuvent considérablement diminuer et les pièces
internes de l’appareil être endommagées.
Ne pas installer l’appareil dans des endroits où des gaz de combustion peu-
vent s’échapper, se dégager ou s’accumuler. L’accumulation de gaz de com-
bustion autour de l’appareil peut provoquer un incendie ou une explosion.
Avertissement:
Précautions à suivre pour éviter tout danger de blessure ou de décès de l’uti-
lisateur.
Précaution:
Décrit les précautions qui doivent être prises pour éviter d’endommager l’ap-
pareil.
L’appareil extérieur produit de la condensation lors du fonctionnement du
chauffage. Prévoir un système de drainage autour de l’appareil extérieur au
cas où la condensation provoquerait des dommages.
Lors de l’installation de l’appareil dans un hôpital ou un centre de commu-
nications, se préparer au bruit et aux interférences électroniques. Les in-
verseurs, les appareils électroménagers, les équipements médicaux haute
fréquence et de communications radio peuvent provoquer un dysfonction-
nement ou une défaillance du climatiseur. Le climatiseur peut également
endommager les équipements médicaux et de communications, perturbant
ainsi les soins et réduisant la qualité d’afchage des écrans.
1. Consignes de sécurité ............................................. 1
2. Emplacement pour l’installation ...................................... 3
3. Installation de l’appareil extérieur .................................... 4
4. Installation de la tuyauterie du réfrigérant .............................. 5
5. Mise en place du tuyau d’écoulement ................................. 7
6. Installations électriques ............................................ 7
7. Marche d’essai .................................................. 9
8. Fonctions spéciales .............................................. 10
9. Contrôle du système (Fig. 9-1) ..................................... 11
10. Rafraîchissement à basse température ambiante ...................... 11
6. Installations électriques ........................................... 17
7. Marche d’essai ................................................. 19
8. Fonctions spéciales .............................................. 20
9. Contrôle du système (Fig. 9-1) ..................................... 21
10. Rafraîchissement à basse température ambiante ...................... 21
BG79U896H14_02fr.indd 1 2021/10/22 15:53:52
013
2
fr
1. Consignes de sécurité
1.3. Avant l’installation électrique
Précaution:
Veiller à installer des coupe-circuits. Dans le cas contraire, un choc élec-
trique peut se produire.
Pour les lignes électriques, utiliser des câbles standard de capacité suf-
fisante. Dans le cas contraire, un court-circuit, une surchauffe ou un in-
cendie peut se produire.
Lors de l’installation des lignes électriques, ne pas mettre les câbles sous
tension. Si les connexions sont desserrées, les câbles peuvent se rompre
et provoquer une surchauffe ou un incendie.
Veiller à mettre l’appareil à la terre. Ne pas relier le l de terre aux conduites
de gaz ou d’eau, aux paratonnerres ou aux lignes de terre téléphoniques. Une
mise à la terre incorrecte de l’appareil peut provoquer un choc électrique.
Utiliser des coupe-circuits (disjoncteur de fuite à la terre, interrupteur
d’isolement (fusible +B) et disjoncteur à boîtier moulé) à la capacité spéci-
fiée. Si la capacité du coupe-circuit est supérieure à celle spécifiée, une
défaillance ou un incendie peut se produire.
1.4. Avant la marche d’essai
Précaution:
Activer l’interrupteur principal au moins 12 heures avant la mise en fonc-
tionnement de l’appareil. L’utilisation de l’appareil juste après sa mise
sous tension peut endommager sérieusement les pièces internes. Laisser
l’interrupteur activé pendant la période d’utilisation.
Avant d’utiliser l’appareil, vérier que tous les panneaux, toutes les protec-
tions et les autres pièces de sécurité sont correctement installés. Les pièces
tournantes, chaudes ou à haute tension peuvent provoquer des blessures.
Ne pas toucher les interrupteurs les mains humides au risque de provoquer
un choc électrique.
Ne pas toucher les tuyaux de réfrigérant les mains nues lors de l’utilisation.
Les tuyaux de réfrigérant sont chauds ou froids en fonction de l’état du
réfrigérant qu’ils contiennent. Toucher les tuyaux peut provoquer des
brûlures ou des gelures.
A la n de l’utilisation de l’appareil, attendre au moins cinq minutes avant
de désactiver l’interrupteur principal. Dans le cas contraire, une fuite d’eau
ou une défaillance peut se produire.
1.5.
Utilisation de climatiseurs utilisant le réfrigérant R410A
Précaution:
Utiliser le cuivre phosphoreux C1220, pour des tuyaux sans soudure en cuivre
et en alliage de cuivre, pour raccorder les tuyaux de réfrigérant. Vérier que
l’intérieur des tuyaux est propre et dépourvu de tout agent nocif tel que des
composés sulfuriques, des oxydants, des débris ou des saletés. Utiliser des
tuyaux d’épaisseur spéciée. (Se reporter à la page 16). Respecter les instruc-
tions suivantes en cas de réutilisation de tuyaux de réfrigérant R22 existants.
-
Remplacer les écrous évasés existants et évaser de nouveau les sections éva-
sées.
- Nepasutiliserdetuyauxns.(Sereporteràlapage16)
Stocker à l’intérieur les tuyaux à utiliser pendant l’installation et couvrir
les deux extrémités jusqu’au processus de brasage. (Laisser les joints de
coude, etc. dans leur emballage.) L’inltration de poussières, de débris ou
d’humidité dans les tuyaux de réfrigérant peut affecter la qualité de l’huile
ou endommager le compresseur.
Appliquer une petite quantité d’huile ester, éther ou alkylbenzène comme
huile réfrigérante sur les sections évasées. Le mélange d’huile minérale et
d’huile réfrigérante peut affecter la qualité de l’huile.
Ne pas utiliser un réfrigérant autre que le réfrigérant R410A. Si c’est le cas,
le chlore peut affecter la qualité de l’huile.
Utiliser les outils suivants spécialement conçus pour une utilisation avec le
réfrigérant R410A. Les outils suivants sont nécessaires pour utiliser le réfri-
gérant R410A. En cas de questions, contacter le revendeur le plus proche.
Outils (pour R410A)
Collecteur jauge Outil d’évasement
Tuyau de charge Jauge de réglage de la taille
Détecteur de fuite de gaz Adaptateur pour pompe à vide
Clé dynamométrique
Echelle électronique de charge de réfrigérant
Veiller à utiliser les outils adaptés. L’inltration de poussières, de débris ou
d’humidité dans les tuyaux de réfrigérant peut affecter la qualité de l’huile
réfrigérante.
• Ne pas utiliser un cylindre de charge. L’utilisation d’un cylindre de charge
peut modier la composition du réfrigérant et réduire son efcacité.
1.2. Avant l’installation (déplacement)
Précaution:
Transportez et installez les appareils avec précaution. L’appareil doit être
transporté par 2 personnes ou plus, car il pèse 20 kg, 44 lbs minimum. Ne
pas tirer les rubans d’emballage. Portez des gants de protection pour sortir
l’appareil de son emballage et pour le déplacer, car vous risquez de vous
blesser les mains sur les ergots ou les arêtes des autres pièces.
• Veiller à éliminer le matériel d’emballage en toute sécurité. Le matériel d’em-
ballage (clous et autres pièces en métal ou en bois) peut provoquer des
blessures.
La base et les xations de l’appareil extérieur doivent être vériées régu-
lièrement pour éviter qu’elles ne se desserrent, se ssurent ou subissent
d’autres dommages. Si ces défauts ne sont pas corrigés, l’appareil peut tom-
ber et provoquer des dommages ou des blessures.
Ne pas nettoyer le climatiseur à l’eau au risque de provoquer un choc élec-
trique.
Serrer les écrous évasés, conformément aux spécications, à l’aide d’une
clé dynamométrique. Si les écrous sont trop serrés, ils peuvent se casser
après un certain temps et provoquer une fuite de réfrigérant.
BG79U896H14_02fr.indd 2 2021/10/22 15:53:53
014
41-11/32
13+1-3/16
52-11/16
8-7/8
23-5/8
14-9/16
Fig. 2-2
A36, A42
3
fr
2. Emplacement pour l’installation
2.1. Tuyaux de réfrigérant (Fig. 2-1)
Vérier que la différence de hauteur entre les appareils intérieur et extérieur,
la longueur du tuyau de réfrigérant et le nombre de coudes permis dans le
tuyau se situent au sein des limites reprises dans le tableau ci-dessous.
Modèles
A Longueur du
tuyau (un sens)
B Différence de
haueur
C Nombre de
coudes (un sens)
PUZ-A12, A18
Max. 30 m, 100 ft Max. 30 m, 100 ft Max. 15
PUZ-A24, A30, A36, A42
Max. 50 m, 165 ft *1 Max. 30 m, 100 ft Max. 15
PUY-A12, A18
Max. 50 m, 165 ft Max. 30 m, 100 ft Max. 15
PUY-A24, A30, A36, A42
Max. 69 m, 225 ft *1 Max. 30 m, 100 ft Max. 15
*1.Sil’appareil extérieurestraccordé àl’appareilintérieur A-COIL(PAA-A18,24,
30, 36, 42), la longueur de la tuyauterie est “Max. 30 m, 100 ft”.
• Lesspécicationsconcernantladifférenced’élévations’appliquentàtoutes dis-
positions des appareils intérieurs et extérieurs, sans tenir compte de celui qui est
le plus élevé.
D Appareil intérieur
E Appareil extérieur
2.2. Sélection de l’emplacement d’installation de
l’appareil extérieur
Eviter les endroits exposés au rayonnement solaire direct ou à d’autres sources de chaleur.
• Sélectionnerunendroitoùlebruitdel’appareiln’incommoderapaslevoisinage.
 Sélectionnerunendroitpermettantunaccèsfaciledescâblesettuyauxàla
source d’alimentation et à l’appareil intérieur.
Eviter les endroits exposés à des risques de fuite, d’échappement ou
d’accumulation de gaz.
Ne pas oublier que des gouttes d’eau peuvent couler de l’appareil lors de son utilisation.
Sélectionnerunendroitdeniveaupouvantsupporterlepoidsetlesvibrationsdel’appareil.
Eviterlesendroitsoùl’appareilpeutêtrerecouvertdeneige.Dansleszonesoùles
chutes de neige importantes sont prévisibles, certaines précautions (par ex., relever
l’emplacement d’installation ou installer une hotte sur l’arrivée d’air) doivent être
prises pour éviter que la neige ne bloque l’arrivée d’air ou ne tombe directement des-
sus. La circulation de l’air risque de diminuer et d’entraîner un dysfonctionnement.
Eviter les endroits exposés à l’huile, à la vapeur ou au gaz sulfurique.
Utiliser les poignées de transport (quatre emplacements à gauche, à droite, à
l’avant et à l’arrière) de l’appareil extérieur pour le déplacer. Transporter l’appareil
par le bas peut provoquer des pincements aux mains ou aux doigts.
2.3.
Dimensions extérieures (Appareil extérieur) (Fig. 2-2)
Fig. 2-1
A
B
E
D
C
37-13/32
13+1-3/16
37-1/8
6-7/8
23-5/8
14-9/16
A12, A18 (inch)
(inch)
(inch)
A24, A30
31-7/8
11-13/16+29/32
24-13/16
6-3/32
19-11/16
2-15/32
13
BG79U896H14_02fr.indd 3 2021/10/22 15:53:54
015
4
fr
A
C
E
BA12, A18
D
A36, A42
A36, A42
14-9/16
(inch)
23-5/8 23-5/8
13
1
Min. 18-7/9
8-7/8
41-11/32
Min. 1
8-7/8
A24, A30
D
Fig. 3-1
2. Emplacement pour l’installation
2.4. Ventilation et espace de service
2.4.1. Installation à un endroit exposé au vent
Lors de l’installation de l’appareil extérieur sur un toit ou à d’autres endroits non
protégés du vent, diriger la sortie d’air de l’appareil vers le côté qui n’est pas directe-
mentexposéauxventsforts.Leventsoufantdanslasortied’airpeutempêcherl’air
de circuler normalement et provoquer un dysfonctionnement.
Voici trois exemples de précautions à prendre.
1 Positionner la sortie d’air vers le mur le plus proche et à environ 500 mm, 19-
11/16 inch de celui-ci. (Fig. 2-3)
2
Installer un guidage d’air et un guidage de sortie d’air en option si l’appareil a été
placéàunendroitoùlesventsviolentsd’untyphon,etc.peuventdirectements’
engouffrer dans la sortie d’air.
(Fig. 2-4)
A Guidage de sortie d’air
3 Placerl’appareildesortequelasortied’airsoufedansladirectionperpendicu-
laire à celle des vents saisonniers, si celle-ci est connue. (Fig. 2-5)
BSensduvent
Fig. 2-4
Fig. 2-3
A
Fig. 2-5
2.4.2. Lors de l’installation d’un seul appareil extérieur (Voir en
dernière page)
Le dimensions minimales sont les suivantes, à l’exception des valeurs Max., indi-
quant les dimensions maximales.
Le chiffre entre parenthèses concerne les modèles A36, A42.
Utiliser les chiffres pour chaque cas.
1 Obstacles uniquement à l’arrière (Fig. 2-6)
2 Obstacles uniquement à l’arrière et au-dessus (Fig. 2-7)
3 Obstacles uniquement à l’arrière et sur les côtés (Fig. 2-8)
* 350 mm, 13-25/32 inch pour A12, A18
4 Obstacles uniquement à l’avant (Fig. 2-9)
* Lors de l’utilisation d’un guidage de sortie d’air en option, le jeu des modèles A42 est de
500 mm, 19-11/16 inch minimum.
5 Obstacles uniquement à l’avant et à l’arrière (Fig. 2-10)
* Lors de l’utilisation d’un guidage de sortie d’air en option, le jeu des modèles A42 est de
500 mm, 19-11/16 inch minimum.
6 Obstacles uniquement à l’arrière, sur les côtés et au-dessus (Fig. 2-11)
* 350 mm, 13-25/32 inch pour A12, A18
• Ne pas utiliser les guidages de sortie d’air en option pour un débit d’air vers le haut.
2.4.3. Lors de l’installation de plusieurs appareils extérieurs (Voir
en dernière page)
Pour A12, A18, laisser 350 mm, 13-25/32 inch et pour A24-A42, laisser 10 mm,
13/32 inch d’espace entre les appareils.
1 Obstacles uniquement à l’arrière (Fig. 2-12)
2 Obstacles uniquement à l’arrière et au-dessus (Fig. 2-13)
Ne pas installer côte à côte plus de trois appareils. Espacer également les appareils, comme illustré.
• Ne pas utiliser les guidages de sortie d’air en option pour un débit d’air vers le haut.
3 Obstacles uniquement à l’avant (Fig. 2-14)
* Lors de l’utilisation d’un guidage de sortie d’air en option, le jeu des modèles A36, A42 est de
1000 mm, 39-3/8 inch minimum.
4 Obstacles uniquement à l’avant et à l’arrière (Fig. 2-15)
* Lors de l’utilisation d’un guidage de sortie d’air en option, le jeu des modèles A36, A42 est de
1000 mm, 39-3/8 inch minimum.
5 Disposition pour un seul appareil parallèle (Fig. 2-16)
* Lors de l’utilisation d’un guidage de sortie d’air en option installé pour un débit d’air vers le
haut, le jeu est de 500 (1000) mm, 19-11/16 (39-3/8) inch minimum.
6 Disposition pour plusieurs appareils parallèles (Fig. 2-17)
* Lors de l’utilisation d’un guidage de sortie d’air en option installé pour un débit d’air vers le
haut, le jeu est de 1000 (1500) mm, 39-3/8 (59-1/16) inch minimum.
7 Disposition pour appareils empilés (Fig. 2-18)
• Il est possible d’empiler jusqu’à deux appareils.
• Ne pas installer côte à côte plus de deux appareils empilés. Espacer également les appar-
eils, comme illustré.
3. Installation de l’appareil extérieur
Bien installer l’appareil sur une surface solide et de niveau, de façon à éviter tout
bruit de crécelle pendant le fonctionnement. (Fig. 3-1)
<Spécicationsdelafondation>
Boulon de fondation M10 (3/8")
Epaisseur de béton 120 mm, 4-23/32 inch
Longueur des boulons 70 mm, 2-3/4 inch
Résistance au poids 320 kg, 264 lbs
• S’assurerquelalongueurdesboulonsdefondationnedépassepas30mm,
1-3/16 inch par rapport à la surface inférieure de la base.
Fixer fermement la base de l’appareil avec quatre boulons de fondation M10 pla-
césàdesendroitssufsammentrobustes.
Installation de l’appareil extérieur
• Nepasbloquerleventilateur.Sileventilateurestbloqué,l’appareilseraralentiet
risque d’être endommagé.
Pour installer l’appareil, utiliser, si nécessaire et en plus de la base de l’appareil, les
oricesd’installationsituésàl’arrièrepourxerlescâbles,etc.Utiliserdesvisauto-
taraudeuses (ø5 × 15 mm, ø13/16 × 19/32 inch moins) et installer l’appareil sur site.
Avertissement:
L’appareil doit être solidement installé sur une structure pouvant supporter
son poids. Si l’appareil est fixé sur une structure instable, il risque de
tomber et de provoquer des dommages ou des blessures.
L’appareil doit être installé conformément aux instructions pour réduire les risques de dom-
mages liés à des tremblements de terre, des typhons ou des vents violents. Une installation
incorrecte peut entraîner la chute de l’appareil et provoquer des dommages ou des blessures.
Max. 23/32 pour A12, A18
Max. 1-3/16 pour A24-42
A
Boulon M10 (3/8 ème de pouce)
B Base
C Aussi long que possible.
D Ventilateur
E
Profondément enfoncé dans la terre
(inch)
Fig. 3-1
A24, A30A12, A18
19-11/16 19-11/16
6-3/32 6-3/32
31-7/8
1-9/32
11-13/16
13
23-5/8 23-5/8
6-7/8 6-7/8
37-13/32
1-3/32 13
14-9/16
(inch)
Min. 25-19/32
Min. 13-25/32
Min. 14-25/32
Min. 1
BG79U896H14_02fr.indd 4 2021/10/22 15:54:00
016
5
fr
A24-A42A12, A18
DD
AE
B
C
45˚± 2˚
A
C
D
B
øA
R1/64 to R1/32
Fig. 4-2
90˚±0,5˚
(inch)
R1/64 à R1/32
Fig. 4-3
4.1.
Consignes pour appareils utilisant le réfrigérant R410A
Se reporter à la page 2 pour les consignes non reprises ci-dessous concer-
nant l’utilisation de climatiseurs avec un réfrigérant R410A.
Appliquer une petite quantité d’huile ester, éther ou alkylbenzène comme
huile réfrigérante sur les sections évasées.
Utiliser le cuivre phosphoreux C1220, pour des tuyaux sans soudure en cuivre
et en alliage de cuivre, pour raccorder les tuyaux de réfrigérant. Utiliser les
tuyaux de réfrigérant dont l’épaisseur est spéciée dans le tableau ci-dessous.
Vérier que l’intérieur des tuyaux est propre et dépourvu de tout agent nocif tel
que des composés sulfuriques, des oxydants, des débris ou des saletés.
Avertissement:
Lors de l’installation, du déplacement ou de l’entretien du climatiseur, n’utilisez
que le réfrigérant spécié (R410A) pour remplir les tuyaux de réfrigérant. Ne pas
le mélanger avec un autre réfrigérant et faire le vide d’air dans les tuyaux.
Si du réfrigérant est mélangé avec de l’air, cela peut provoquer des pointes de
pression dans les tuyaux de réfrigérant et entraîner une explosion et d’autres
risques.
L’utilisation d’un réfrigérant différent de celui spécié pour le climatiseur peut
entraîner des défaillances mécaniques, des dysfonctionnements du système
ou une panne de l’appareil. Dans le pire des cas, cela peut entraîner un obs-
tacle à la mise en sécurité du produit.
A12, A18 A24-A42
Conduit de
liquide
ø6,35 mm, 1/4inch
épaisseur 0,8 mm, 1/32 inch
ø9,52 mm, 3/8 inch
épaisseurs 0,8 mm, 1/32 inch
Conduit de gaz ø12,7 mm, 1/2 inch
épaisseur 0,8 mm, 1/32 inch
ø15,88 mm, 5/8 inch
épaisseur 1,0 mm, 3/64 inch
Ne pas utiliser de tuyaux plus ns que ceux spéciés ci-dessus.
4.2. Connexion des tuyaux (Fig. 4-1) (Fig. 4-2)
En cas d’utilisation de tuyaux en cuivre disponibles sur le marché, isoler séparé-
ment les tuyaux de liquide et de gaz avec un matériau isolant vendu dans le com-
merce (résistant à une température de 100 °C, 212 °F ou plus, et d'une épaisseur
de 12 mm, 1/2 inch ou plus). (Fig. 4-1)
Les parties intérieures du tuyau d’écoulement doivent également être entourées
dematièreisolanteenmoussedepolyéthylène(avecunepoidsspéciquede0,03
et de 9 mm, 23/64 inch d’épaisseur ou plus).
[Fig. 4-2]
•Appliquerunlmminced’huileréfrigérantesurlasurfacedutuyauetdusupportdu
joint avant de serrer l’écrou évasé. A
Utiliser deux clés pour serrer les connexions des tuyaux. B
Lorsque le raccord des tuyaux est terminé, utiliser un détecteur de fuite de gaz ou une
solution savonneuse à base d’eau pour s’assurer qu’il n’y ait pas de fuite de gaz.
Appliquer de l’huile réfrigérante sur toute la surface évasée du fond. C
Utiliser les écrous évasés correspondant aux tailles de tuyaux suivantes. D
Remarques:
1.Leraccordconiqueestxéàsontuyau.
2. Le raccord conique se trouve dans l’accessoire pour appareil extérieur.
Nepasutiliserleraccordconiquexé:celapourraitprovoquerunefuitedegaz,
voire l’extraction du tuyau.
Veiller à ne pas rompre les tuyaux lors de leur courbure. Des rayons de courbure
comprisentre100mm,3-15/16inchà150mm,5-27/32inchsufsent.
• Vérier que les tuyaux ne touchent pas le compresseur. Des vibrations ou des
bruits anormaux pourraient se produire.
1 Raccorder les tuyaux en commençant par l’appareil intérieur.
Serrerlesécrousévasésàl’aided’uneclédynamométrique.
2 Evaser les conduits de liquide et de gaz, puis appliquer un lm mince d’huile
réfrigérante (application sur site).
Avertissement:
Pendant l’installation de l’appareil, brancher correctement les tuyaux de réfri-
gérant avant de lancer le compresseur.
4.3. Mise en place des tuyaux de réfrigérant (Fig. 4-3)
Pour A12, A18
Retirer le panneau de service D (2 vis).
Pour A24-A42
Retirer le panneau de service D (3 vis) le cache-tuyaux avant A (2 vis) et le cache-
tuyaux arrière B (2 vis:PUZ(Y)-A24, A30NHA7) (4 vis:PUZ(Y)-A36, A42NKA7).
1 Effectuer les raccordements des tuyaux de réfrigérant de l’appareil intérieur/exté-
rieur lorsque la vanne d’arrêt de l’appareil extérieur est complètement fermée.
2 Faire le vide d’air de l’appareil intérieur et des tuyaux de raccordement.
3Unefoislestuyauxderéfrigérantraccordés,vérierleséventuellesfuitesdegaz
dans les tuyaux raccordés et l’appareil intérieur. (Voir 4.4. Test d’étanchéité des
tuyaux de réfrigérant.)
4Viderlestuyauxderéfrigérantparl’orice deservicedelavanned’arrêtde li-
quide, puis ouvrir complètement les vannes d’arrêt (de gaz et de liquide). Cette
opération permet le raccordement complet des tuyaux de réfrigérant des appa-
reils intérieur et extérieur.
• Faire fonctionner l’appareil sans avoir ouvert les vannes d’arrêt risque d’endom-
mager le compresseur et la vanne de commande.
Utiliserundétecteurdefuitesoudel’eausavonneusepourvérierleséventuelles
fuites de gaz aux sections de raccordement des tuyaux de l’appareil extérieur.
• Ne pas utiliser le réfrigérant de l’appareil pour faire le vide d’air des tuyaux de
réfrigérant.
Après avoir utilisé les vannes, resserrer leurs capuchons au couple correct : 20
à 25 N·m, 14 à 18 ft·lbs (200 à 250 kgf·cm).
 Silescapuchonssontmalreplacésouresserrés,unefuitederéfrigérantpeut
se produire. Veiller également à ne pas endommager l’intérieur des capuchons
des vannes car leur étanchéité empêche les fuites de réfrigérant.
5 Appliquer un agent d’étanchéité sur les extrémités de l’isolation thermique autour
dessectionsderaccordementdestuyauxand’empêcherl’eaudepénétrerdans
l’isolation thermique.
4. Installation de la tuyauterie du réfrigérant
A (Fig. 4-1)
Diam. ext. Tuyau en cuivre Dimensions évasement
Dimensions øA
(mm) (inch) (mm) (inch)
ø6,35 1/4” 8,7 - 9.1 11/32 - 23/64
ø9,52 3/8” 12,8 - 13,2 1/2 - 33/64
ø12,7 1/2” 16,2 - 16,6 41/64 - 21/32
ø15,88 5/8” 19,3 - 19,7 49/64 - 25/32
B (Fig. 4-1)
Diam. ext. Tuyau en cuivre Diam.ext. raccord conique Couple de serrage
(mm) (inch) (mm) (inch) (N·m) (ft·lbs)
ø6,35 1/4” 17 43/64 14 - 18 10 - 13
ø9,52 3/8” 22 7/8 34 - 42 25 - 30
ø12,7 1/2” 26 1 - 3/64 49 - 61 35 - 44
ø15,88 5/8” 29 1 - 9/64 68 - 82 49 - 59
A Dimension de l’évasement
B Couple de serrage du raccord conique
A
Couvercle de la tuyauterie avant
B Couvercle de la tuyauterie
C Vanne d’arrêt
D Panneau de service
E Rayon de cintrage : 100 mm, 3-15/16 inch-150 mm, 5-27/32 inch
A Conduit de liquide
B Conduit de gaz
C Isolation thermique
D Rubanage
Fig. 4-1
A
B
C
D
A12, A18 A24 - A42
Côté gaz Diamètre du tuyau (mm, inch) ø12,7, 1/2” ø15,88, 5/8”
Côté liquide Diamètre du tuyau (mm, inch) ø6,35, 1/4” ø9,52, 3/8”
BG79U896H14_02fr.indd 5 2021/10/22 15:54:01
017
6
fr
4. Installation de la tuyauterie du réfrigérant
4.4. Test d’étanchéité des tuyaux de réfrigérant
(1) Connecter les outils de test.
Vérierquelesvannesd’arrêtA et B sont fermées et ne pas les ouvrir.
Ajouterdelapressiondanslestuyauxderéfrigérantparl’oricedeserviceC
de la vanne d’arrêt de liquide D.
(2)
Nepasajouterenuneseulefoisdepressionàlapressionspéciéemaisprogressivement.
1
Pressuriserjusqu’à0,5MPa(5kgf/cm²G),attendrecinqminutesetvérier
que la pression ne diminue pas.
2
Pressuriserjusqu’à 1,5MPa(15kgf/cm²G),attendrecinqminutesetvérier
que la pression ne diminue pas.
3
Pressuriser jusqu’à 4,15 MPa (41,5 kgf/cm²G), puis mesurer la température
ambiante et la pression du réfrigérant.
(3)
Silapressionspéciéesemaintientpendantenvironunejournéesansdiminu-
er, les tuyaux ne présentent pas de fuite.
•Silatempératureambiantevariede1°C,lapressionvaried’environ0,03MPa
(0,3 kgf/cm²G). Apporter les corrections nécessaires.
(4)
Silapressiondiminueàl’étape(2)ou(3),ilyaunefuitedegaz.Rechercher
l’origine de la fuite de gaz.
4.5. Comment ouvrir la vanne d’arrêt (Fig. 4-5)
1 Retirez le bouchon, et tournez la tige de soupape à fond dans le sens antihoraire
avec une clé hexagonale de 4 mm, 5/32 inch. Arrêtez de tourner quand elle
frappe la retenue. (ø6,35, 1/4 inch: env. 4,5 tours) (ø9,52, 3/8 inch: env. 10 tours)
2Vérierquelavanned’arrêtestcomplètementouverte,appuyersurlapoignée
et tourner le capuchon pour le ramener sur sa position d’origine.
A Vanne
B Côté appareil
C Coté de fonctionnement
D Capuchon
E Côté tuyau local
F Gaine du tuyau
GOricepourl’entretien
HOricepourlaclé
Les tuyaux de réfrigérant sont entourés d’une couche de protection pour A24-A42
Les tuyaux peuvent être entourés, après ou avant avoir été raccordés, d’une
couche de protection allant jusqu’à ø90 mm, 3-35/64 inch. Découper la rondelle
défonçable du cache-tuyaux en suivant la rainure et envelopper les tuyaux.
Oriced’entréedutuyaupourA24-A42
Appliquer du mastic ou un agent d’étanchéité sur l’entrée des tuyaux pour éviter
tout espace.
(Silesespacesnesontpassupprimés,l’appareilrisquedefonctionnerbruyam-
mentoud’êtreendommagéàcaused’uneinltrationd’eauetdepoussières).
I
Côté clé double
(Utiliser une clé de ce côté uniquement. Dans le cas
contraire, une fuite de liquide pourrait en résulter.)
J
Côté joint d’étanchéité
(Etancher l’extrémité de l’isolation thermique
du côté du raccord du tuyau avec un produit
d’étanchéitéquelconquepourévitertouteinltra-
tion d’eau dans le matériel d’isolation thermique.)
K Poignée
D
G
B
A
I
F
E
J
H
Fig. 4-5
A Vanned’arrêt<côtéliquide>
B Vanned’arrêt<côtégaz>
C Oricepourl’entretien
D Sectiond’ouverture/fermeture
E Tuyau local
F Hermétique, idem pour le côté gaz
G Fourrure du tuyau
H Ne pas utiliser de clé ici.
Il pourrait y avoir des fuites de
réfrigérant.
I Utiliser deux clés ici.
Fig. 4-6
c
B
A
D
Remarques:
1.Lagureàgauchen’estreprésentéequ’àtitre
d’exemple.
La forme de la vanne d’arrêt, la position de
l’ouverture de service, etc., peuvent différer
selon le modèle.
2. Tournez la section A uniquement.
(Ne serrez pas davantage les sections A et
B l’une contre l’autre.)
C Flexible de charge
D Ouverture de service
Précautions à prendre lors de l’utilisation de la soupape de charge (Fig. 4-6)
Ne serrez pas trop l’ouverture de service au moment de l’installer, car vous pour-
riez déformer le corps de la soupape et des fuites pourraient se produire.
Après avoir posé la section B dans la direction désirée, tournez la section A
uniquement et serrez-la.
Ne serrez pas davantage les sections A et B l’une contre l’autre après avoir serré
la section A.
Avertissement:
Lors de l’ouverture ou de la fermeture de la vanne sous des températures de
congélation, le réfrigérant peut jaillir de l’espace entre la tige de vanne et le
corps de vanne et provoquer des blessures.
A
B
H
I
C
D
E
F
G
D
B
A
C
Fig. 4-4
BG79U896H14_02fr.indd 6 2021/10/22 15:54:02
018
7
fr
4.6. Ajout de produit réfrigérant
• Une charge supplémentaire n’est pas nécessaire si la longueur du tuyau ne
dépasse pas 21 m, 70 ft pour A12-A30, 30 m 100 ft pour A36, A42.
• En particulier, une charge supplémentaire n’est pas nécessaire si la longueur du
tuyau ne dépasse pas 30 m, 100 ft pour A24, 30, 36, A42 raccordé à l’appareil
intérieur A-COIL (PAA-A18, 24, 30, 36, 42).
•Silalongueurdutuyaudépasselalongueurspéciéeci-dessus,rechargerl’ap-
pareil en gaz réfrigérant R410A en fonction des longueurs de tuyau autorisées
dans le tableau ci-dessous.
Remarques:
1. Une fois l’appareil arrêté, le charger de réfrigérant supplémentaire par la
vanne d’arrêt de liquide après avoir vidé les extensions de tuyaux et l’appareil
intérieur. Lors de l’utilisation de l’appareil, ajouter du réfrigérant par le clapet
de non-retour du gaz à l’aide d’un chargeur de sécurité. Ne pas ajouter de
réfrigérant liquide directement par le clapet de non-retour.
2. Une fois l’appareil chargé de réfrigérant, noter la quantité de réfrigérant
ajouté sur l’étiquette de service (collée sur l’appareil).
Pour plus d’informations, se reporter à la section “1.5. Utilisation de climati-
seurs utilisant le réfrigérant R410A”.
• L’installation de plusieurs appareils doit se faire avec précaution. Le raccorde-
ment à un appareil intérieur défaillant peut entraîner une pression anormalement
élevée et altérer sérieusement les performances de l’appareil.
Modèle Longueur de
tuyau max.
Différence
de hauteur
max.
Quantité de charge de réfrigérant ajouté (kg/oz) *2
21 m
70 ft
24 m
80 ft
27 m
90 ft
30 m
100 ft
34 m
110 ft
37 m
120 ft
40 m
130 ft
43 m
140 ft
46 m
150 ft
49 m
160 ft
50 m
165 ft
52 m
170 ft
55 m
180 ft
58 m
190 ft
61 m
200 ft
64 m
210 ft
67 m
220 ft
69 m
225 ft
PUZ-A12, 18 30 m, 100 ft 30 m, 100 ft 0
0,06 kg
2 oz
0,11 kg
4 oz
0,17 kg
6 oz
--------------
PUZ-A24, 30
50 m, 165 ft *1
30 m, 100 ft 0
0,20 kg
7 oz
0,40 kg
14 oz
0,60 kg
21 oz
0,79 kg
28 oz
0,99 kg
35 oz
1,19 kg
42 oz
1,39 kg
49 oz
1,59 kg
56 oz
1,79 kg
63 oz
1,89 kg
67 oz
-------
PUZ-A36, 42
50 m, 165 ft *1
30 m, 100 ft 0 0 0 0
0,20 kg
7 oz
0,40 kg
14 oz
0,26 kg
21 oz
0,79 kg
28 oz
0,99 kg
35 oz
1,19 kg
42 oz
1,29 kg
46 oz
-------
PUY-A12, 18 50 m, 165 ft 30 m, 100 ft 0
0,03 kg
1 oz
0,06 kg
2 oz
0,09 kg
3 oz
0,11 kg
4 oz
0,14 kg
5 oz
0,17 kg
6 oz
0,20 kg
7 oz
0,23 kg
8 oz
0,26 kg
9 oz
0,27 kg
10 oz
-------
PUY-A24, 30
69 m, 225 ft *1
30 m, 100 ft 0
0,09 kg
3 oz
0,17 kg
6 oz
0,26 kg
9 oz
0,34 kg
12 oz
0,43 kg
15 oz
0,51 kg
18 oz
0,60 kg
21 oz
0,68 kg
24 oz
0,77 kg
27 oz
0,81 kg
29 oz
0,85 kg
30 oz
0,94 kg
33 oz
1,02 kg
36 oz
1,11 kg
39 oz
1,19 kg
42 oz
1,28 kg
45 oz
1,32 kg
47 oz
PUY-A36, 42
69 m, 225 ft *1
30 m, 100 ft 0 0 0 0
0,09 kg
3 oz
0,17 kg
6 oz
0,26 kg
9 oz
0,34 kg
12 oz
0,43 kg
15 oz
0,51 kg
18 oz
0,55 kg
20 oz
0,60 kg
21 oz
0,68 kg
24 oz
0,77 kg
27 oz
0,85 kg
30 oz
0,94 kg
33 oz
1,02 kg
36 oz
1,06 kg
38 oz
*1.Sil’appareilextérieurestraccordéàl’appareilintérieurA-COIL(PAA-A18,24,30,36,42),lalongueurdelatuyauterieest“Max.30m,100ft”.
*2. Ce tableau des réfrigérants supplémentaire n’est utilisé que s’il est raccordé à un appareil intérieur autre qu’une unité intérieure A-COIL (PAA-A18, 24, 30, 36, 42). Une
charge supplémentaire n’est pas nécessaire si la longueur du tuyau ne dépasse pas 30 m, 100 ft pour A24, 30, 36, A42 raccordé à l’appareil intérieur A-COIL (PAA-A18,
24, 30, 36, 42).
5. Mise en place du tuyau d’écoulement
Raccordement du tuyau d’écoulement de l’appareil extérieur
Lorsqu’un tuyau d’écoulement s’avère nécessaire, utiliser la douille de drainage ou la cuvette de drainage (en option).
A12, A18 A24, A30 A36, A42
Douille de drainage PAC-SJ08DS-E PAC-SG61DS-E
Cuvette de drainage PAC-SG63DP-E PAC-SG64DP-E PAC-SH97DP-E
6. Installations électriques
6.1. Appareil extérieur (Fig. 6-1, Fig. 6-2)
1 Retirer le panneau de service.
2Effectuerlecâblageconformémentauxgures6-1et6-2.
A Appareil intérieur
B Appareil extérieur
C Télécommande
D Interrupteur/fusible principal
(Disjoncteur)
E Mise à la terre
Pour alimentation
Pour
alimentation
A Borne de terre
B Embase de borne
C Attache
D Panneau de service
EAcheminerlescâblesdemanière
qu’ils ne touchent pas le centre du
panneau de service ou la vanne de
gaz.
A
C
C
E
E
EE E
S3
S3
S2
S1
S2S1L1 L2
GR
A
B
B
D
D
A
4. Installation de la tuyauterie du réfrigérant
Fig. 6-2
A12, A18
A24-A42
E
B
A
F
C
L1
GR
L2 S1 S2 S3
A
B
C
DE
L1
GR
L2 S1 S2 S3
Fig. 6-1
BG79U896H14_02fr.indd 7 2021/10/22 15:54:02
019
8
fr
A12, A18
A24-A42
6. Installations électriques
TERMINAL BED
SANGLEACABLE
PANNEAUDESERVICE
COUVRE-CABLE
COUVRE-TUBE
PLAQUETTE DE TUBE: accessoire
BG79U896H14_02fr.indd 8 2021/10/22 15:54:05
020
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Mitsubishi Electric PUZ-A18NKA7 Manuel utilisateur

Catégorie
Climatiseurs split-system
Taper
Manuel utilisateur