Telemecanique Sensors XCSDMR791L01M12 Mode d'emploi

Catégorie
Éclairage de confort
Taper
Mode d'emploi
XCS DMC / DMP / DMR (EAC)
Printed in
r
3,5/0.14
6,5/0.25 13
0.51
8/0.31
25
0.98
78/3.07
88/3.46
2xØ4,5
0.18
46
1.81
Ø15
0.59
M12
8/0.31
2xØ3,5/0.14
2xØ6/0.23
7/0.27
16
0.63
51/2
16
0.63
3,5
0.14
36
1.42
Ø10
0.39
M08
13
0.51
88/3.46
r 30/1.18
2xØ4,5
0.18
8
25
0.98
3,5/0.14
6,5/0.25
151/5.95
78/3.07
0.14
7/0.27
51/2
3,5
16
0.63
8
0.31
2xØ3,5
0.14
2xØ6
0.23
16/0.63
12,5
0.49
30/1.18
151
5.95
XCSDMppp
Coded magnetic switches
Interrupteurs magnétique codé
Codierte Magnetschalter
Interruptores magnéticos codificados
Interruttori magnetici codificati
Interruptores magnéticos codificados
XCSDMC
XCSZCpppp + XCSZC1
XCSDMP
XCSZPpppp + XCSZP1
XCSDMR
XCSZRpppp + XCSZR1
Dimensions / Encombrements / Abmessungen /
Dimensiones / Dimensioni / Dimensões
XCSDMC
XCSDMP XCSDMR
mm
in.
2xØ4,3/0.17
Ø29,5
1.16
M30x1,5
16
7/0.27
0.63
13
0.51
38,5/1.51
1,5x45°
0.06x45°
r 30/1.18
151/5.95
www.tesensors.com
1/6
02 - 2017
AAV82775 06
A instalação, utilização e manutenção do equipamento eléctrico devem ser efectuadas exclusivamente por pessoal qualificado. A Schneider Electric não assume qualquer
responsabilidade pelas consequências resultantes da utilização deste material.
Le apparecchiature elettriche devono essere installate, usate e riparate solo da personale qualificato. Schneider Electric non assume nessuna responsabilità per qualunque
conseguenza derivante dall'uso di questo materiale.
Sólo el personal de servicio cualificado podrá instalar, utilizar, reparar y mantener el equipo eléctrico. Schneider Electric no asume las responsabilidades que pudieran
surgir como consecuencia de la utilización de este material.
Electrical equipment should be installed, operated and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences
arising out of the use of this material.
Elektrische Geräte dürfen nur von Fachpersonal installiert, betrieben, gewartet und instand gesetzt werden. Schneider Electric haftet nicht für Schäden, die aufgrund
der Verwendung dieses Materials entstehen.
Les équipements électriques doivent être installés, exploités et entretenus par un personnel qualifié. Schneider Electric n'assume aucune responsabilité
des conséquences éventuelles découlant de l'utilisation de cette documentation.
en
fr
de
es
it
pt
© 2017 Schneider Electric. “All Rights Reserved.”
English
These devices have been designed to be in compliance
with the standards currently in effect: EN/IEC 60947-5-1,
EN/ISO 13849-1, EN/IEC 62061, EN/IEC 60947-1,
EN/ISO 14119, EN/IEC 60204.
These devices can achieve up to category 4 PL=e or SIL 3
(if combined with an appropriate PREVENTA XPS safety
unit PL=e / SIL 3).
Ces appareils ont été conçus d’après les normes
actuellement en vigueur : EN/IEC 60947-5-1, EN/ISO
13849-1, EN/IEC 62061, EN/IEC 60947-1, EN/ISO 14119,
EN/IEC 60204.
Ces équipements peuvent atteindre un circuit de
commande jusqu'à la catégorie 4 PL=e ou SIL 3
correspondant (en combinaison avec une unité de
sécurité PREVENTA XPS appropriée PL=e / SIL 3).
Die Geräte wurden gemäß den geltenden Normen EN/IEC
60947-5-1, EN/ISO 13849-1, EN/IEC 62061, EN/IEC
60947-1, EN/ISO 14119, EN/IEC 60204 entwickelt.
Diese Geräte können bis Kategorie 4 PL = e bzw. SIL 3 zu
erreichen (wenn mit einer entsprechenden PREVENTA
XPS Sicherheitsmodul kombiniert PL = e / SIL 3)
erreichen.
Estos dispositivos han sido diseñados de conformidad con
las normas actualmente en vigor EN/IEC 60947-5-1,
EN/ISO 13849-1, EN/IEC 62061, EN/IEC 60947-1, EN/ISO
14119, EN/IEC 60204.
Estos dispositivos permiten conseguir hasta la categoría 4
PL = e o SIL 3 (si se combina con una unidad de
seguridad PREVENTA XPS apropiado PL = e / SIL 3).
Questi dispositivi sono stati progettati secondo le norme in
vigore: EN/IEC 60947-5-1, EN/ISO 13849-1, EN/IEC
62061, EN/IEC 60947-1, EN/ISO 14119, EN/IEC 60204.
Questi dispositivi consentono di ottenere fino a categoria 4
PL = e o SIL 3 (se combinato con un adeguato unità di
sicurezza PREVENTA XPS PL = e / SIL 3).
Estes aparelhos foram concebidos para estar em
conformidade com as normas em vigor: EN/IEC
60947-5-1, EN/ISO 13849-1, EN/IEC 62061, EN/IEC
60947-1, EN/ISO 14119, EN/IEC 60204.
Estes aparelhos permitem atingir até à categoria 4 PL = e
ou SIL 3 (se combinado com uma unidade de segurança
PREVENTA XPS apropriado PL = e / SIL 3).
Franç
ais Deutsch
Espa
ñol
Italiano Portugu
ês
A não observância destas instruções pode provocar
a morte, ferimentos graves, ou danos no equipamento.
Si no se siguen estas instrucciones pueden
producirse lesiones personales graves o mortales o
daños en el equipo.
Le non-respect de ces instructions peut provoquer la
mort, des blessures graves ou des dommages
matériels.
Failure to follow these instructions can result in
death, serious injury, or equipment damage.
WARNING / AVERTISSEMENT / WARNUNG / ADVERTENCIA / AVVERTIMENTO / AVISO
Il mancato rispetto di queste istruzioni può provocare
morte, gravi infortuni o danni alle apparecchiature.
Die Nichtbeachtung dieser Anweisungen kann zu Tod,
schwerer Körperverletzung oder Materialschäden
führen.
FUNCIONAMIENTO INESPERADO DEL EQUIPO
UNINTENDED EQUIPMENT OPERATION
FUNCIONAMENTO NÃO PREVISTO DOS
EQUIPAMENTOS
FONCTIONNEMENT INATTENDU DE L'EQUIPEMENT UNBEABSICHTIGTER GERÄTEBETRIEB
FUNZIONAMENTO NON INTENZIONALE
DELL’ APPARECCHIATURA
Le non-respect de ces instructions peut provoquer
des blessures ou des dommages matériels.
Failure to follow these instructions can result in
injury or equipment damage.
Il mancato rispetto di queste istruzioni può
provocare infortuni o danni alle apparecchiature.
Si no se siguen estas instrucciones pueden pro-
ducirse lesiones personales o daños en el equipo.
Die Nichtbeachtung dieser Anweisungen kann zu
Körperverletzungen oder Materialschäden führen.
A não observância destas instruções pode provo-
car ferimentos pessoais, ou danos no equipamento.
RIESGO DE DAÑOS MATERIALES RISCHIO DI DANNI MATERIALI DANOS NOS EQUIPAMENTOS
RISQUE DE DOMMAGE MATERIELRISK OF MATERIAL DAMAGE GEFAHR VON MATERIALSCHÄDEN
CAUTION / ATTENTION / ACHTUNG / AVISO / ATTENZIONE / ATENCÃO
XCS DMC / DMP / DMR (EAC)
Safety solutions using Preventa
Solutions de sécurité selon Preventa
Sicherheitslösungen mit Preventa
Soluciones de seguridad según Preventa
Soluzioni di sicurezza secondo Preventa
Soluções de segurança da Preventa
Cable connection procedures
Procédures de connexion des câbles
Kabelanschlüsse
Procedimentos de conexión de los cables
Procedure di collegamento dei cavi
Procedimentos para a conexão de cabos
mm
in.
Do not use magnetic or magnetized screws to mount
safety switches.
Do not mount safety switches in locations subject to
magnetic fields in excess of 0.3 mT.
Los interruptores de seguridad no deben instalarse por
medio de tornillos magnéticos o magnetizados.
• Los interruptores de seguridad no deben instalarse en
ubicaciones expuestas a campos magnéticos de más
de 0.3 mT.
Do not use safety switch as a mechanical stop.
• Do not adjust the position of switches using a hammer
or other tool likely to exceed the device's shock and
vibration tolerances.
Ne
pas utiliser les interrupteurs de sécurité comme
butées
mécaniques.
• Ne pas régler la position des interrupteurs à l'aide d'un
marteau, ou de tout autre outil qui pourrait dépasser les
tolérances du dispositif aux chocs et aux vibrations.
Verwenden Sie den Sicherheitsschalter nicht als
mechanische Abschaltung.
Passen Sie die Position der Schalter nicht mit einem
Hammer oder einem anderen Werkzeug an, die
wahrscheinlich die Toleranzwerte für Geräteschläge
und-vibrationen überschreiten.
Não utilize o interruptor de segurança como um meio
de paragem mecânico.
Não ajuste a posição dos interruptores utilizando um
martelo ou outra ferramenta susceptível de ultrapassar
as tolerâncias aos choques e às vibrações do
dispositivo.
Non utilizzare il vostro interruttore di sicurezza come
arresto meccanico.
Non regolare la posizione degli interruttori con un
martello o un altro attrezzo simile che possa superare
le tolleranze d’urto e di vibrazione del dispositivo.
Los interruptores de seguridad no deben utilizarse
como topes mecánicos.
La posición de los interruptores no debe ajustarse por
medio de un martillo u otra herramienta que podría
exceder
las tolerancias del dispositivo a los choques y
vibraciones.
Ne pas monter les interrupteurs de sécurité
à l'aide de
vis magnétiques ou de vis magnétisées.
Ne pas monter les interrupteurs de sécurité dans des
endroits exposés à des champs magnétiques
supérieurs à 0,3 mT.
Non utilizzare viti magnetiche o magnetizzate per
montare gli interruttori di sicurezza.
Non montare gli interruttori di sicurezza in posti
soggetti a campi magnetici superiori a 0,3 mT.
Verwenden Sie keine Magnet- oder magnetisierten
Schrauben, um die Sicherheitsschalter zu montieren.
Montieren Sie keine Sicherheitsschalter in
Umgebungen, die Magnetfeldern über 0.3 mT
ausgesetzt sind.
Não utilize parafusos magnéticos ou magnetizados
para montar os interruptores de segurança.
Não monte os interruptores de segurança em locais
sujeitos a campos magnéticos de intensidade superior
a 0,3 mT.
2/6
AAV82775 06
www.tesensors.com
100/3.93
100/3.93
100/3.93
100/3.93
Functional directions - Minimum distance between the magnet and the sensor
Directions fonctionnelles - Distance minimale entre l'aimant et le capteur
Funktions-Richtungen - Mindestabstand zwischen dem Magneten und dem Sensor
Direcciones funcionales - Distancia mínima entre el imán y el sensor
Direzioni funzionali - Distanza minima tra il magnete e il sensore
Direcções funcionais - Distância mínima entre o íman eo sensor
XCSDMC XCSDMRXCSDMP
u 0.3 mT
1
0.04
1
0.04
1
0.04
1
0.04
1
0.04
1
0.04
1
0.04
mm
in.
XCS DMC: Sao 4 mmm/0.16 in.
XCS DMP:
Sao 4 mmm/0.16 in.
> 40
> 1.57
XZCP0941L2
XZCP0941L5
XZCP0941L10
XZCP1041L2
XZCP1041L5
XZCP1041L10
BK WH
BU BN
M8
XZCP1141L2
XZCP1141L5
XZCP1141L10
XZCP1241L2
XZCP1241L5
XZCP1241L10
M12
BU BK
WH BN
XZCP29P11L2
XZCP29P11L5
XZCP29P11L10
M12
5/GY
1/WH
6/PK
3/GN 7/BU
2/BN
8/RD
4/YE
Minimum mounting clearances between safety switches and ferromagnetic materials
Espaces de dégagement minimum, au montage, entre interrupteurs de sécurité et matériaux ferromagnétiques
Minimaler Abstand zwischen Sicherheitsschaltern und ferromagnetischen Materialien
Espacios libros mínimos para el montaje, entre los interruptores de seguridad y los materiales ferromagnéticos
Spazio di montaggio minimo tra gli interruttori di sicurezza e materiali ferromagnetici;
Distâncias mínimas de montagem entre interruptores de segurança e materiais ferromagnéticos XCSDMR
XCS DMC / DMP / DMR (EAC)
XCSDMC XCSDMRXCSDMP
1.42 in.
36 mm
12 N.m max.
106 lb-in
1 N.m max.
8.8 lb-in
1 N.m max.
8.8 lb-in
Pre-Wired Female Connectors
Prolongateurs
Verlängerungskabel
Extensiones de cables
Prolunghe
Cabos de Extensão
A, B and C non-magnetic shim
A, B et C cale amagnétique
A, B und C unmagnetischer Keil
A, B y C calce amagnético
A, B e C spessore amagnetico
A, B e C calço não magnético
A = XCS ZCC (x2)
B = XCS ZCP (x2)
C = XCS ZCR (x1)
Tightening torque, tightening capacity
Couple de serrage, capacité de serrage
Anzugdrehmoment, Anzugvermögen
Par de apriete, capacidad de apriete
Coppia di serraggio, capacità di serraggio
Binário de aperto, capacidade de aperto
3/6
AAV82775 06
www.tesensors.com
b
a
B
XCSDMP
a
b
A
XCMDSC
mm / in.
XCSDMC
XCSDMP
40/1.57 13/0.51 81/3.19 x 55/2.16
100/3.94 10/0.39 118/4.64 x 55/2.16
a ub uc x d u
Ø > 45
Ø > 1.77
> 10
> 0.39
> 12
> 0.47
> 20
> 0.79
> 5
> 0.2
C
Fig. 1
< 10
< 0.39
> 12
> 0.47
> 20
> 0.79
C
Fig. 3
Ø > 45
Ø > 1.77
> 10
> 0.39
> 13
> 0.51
> 5
> 0.2
Fig. 2
< 10
< 0.39
> 17
> 0.67
Fig. 4
d
c
d
c
Sao : Assured Operating Distance / Portée de travail assurée / Gewährleisteter Arbeitsbereich / Alcance de trabajo asegurado
Portata di lavoro garantita / Alcance de trabalho assegurado 1 mm = 0.04 in.
XCSDMC
Sao
1
XCSDMC
Sao
1
Sao
0 3-3 4-4 5-5 2-2 1-1
10
8
6
4
2
0
L
XCSDMP
1
XCSDMR
L (mm)
10
8
6
4
2
0
L
0 3-3 2-2 1-1
Sao
1
XCSDMR
α(°)
- 40°
140°
- 20°
160°
180°
20°
200°
40°
220°
°
°
60
240
- 60°
120°
10
8
6
4
2
0
α
Sao
1
XCSDMC
Sao
1
XCS DMC / DMP / DMR (EAC)
1
4
Wiring diagram / Mise en œuvre électrique / Anschluß Schema /
Instalación eléctrica / Collegamenti elettrici / Instalação eléctrica
RISQUE D'ELECTROCU-
TION, D' EXPLOSION OU
D' ARC ELECTRIQUE
Coupez l'alimentation avant
de travailler sur cet appareil.
Le non-respect de ces
instructions provoquera
la mort ou des blessures
graves.
HAZARD OF ELECTRIC
SHOCK, EXPLOSION
OR ARC FLASH
Disconnect all power before
servicing equipment.
Failure to follow these
instructions will result
in death or serious
injury.
DANGER / DANGER / PELIGRO
RIESGO DE ELECTROCUCIÓN,
EXPLOSIÓN O ARCO
ELÉCTRICO
Desconecte toda alimentació-
nantes de realizar el servicio.
Si no se respetan estas
instrucciones, se producirán
graves daños corporales
o la muerte.
Note: Unused inputs must be jumpered to enable
actuation of the outputs.
Note: Unused inputs must be jumpered to enable
actuation of the outputs.
Illustration of contacts with magnet present
Représentation des contacts en présence de l’aimant
Darstellung der Kontakte, bei Magnetbetätigung
Representación de los contactos en presencia del imán
Rappresentazione dei contatti in presenza del magnete
Representação dos contactos em presença do ímã
Fault
Detection
Fault Detected
Logic
Cat. 4 / PL=e (EN/ISO 13849-1) / SIL3 - XPSDMB
Cat. 3 / PL=d (EN/ISO 13849-1) / SIL2 - XPSDMB
Cat. 3 / PL=d (EN/ISO 13849-1) / SIL2 - XPSDME
Fault
Detection
Fault Detected
Logic
Cat. 4 / PL=e (EN/ISO 13849-1) / SIL3 - XPSDME
Logic
Cat. 4 / PL=e (EN/ISO 13849-1) / SIL3 - XPSAF
4/6
AAV82775 06
www.tesensors.com
XCS DMC59pp
(NC + NO)
XCS DMR59pp
(NC + NO)
XCS DMP50pp
(NC + NC + NO)
/ / /
XCS DMC59pp
(NC + NO)
XCS DMR59pp
(NC + NO)
XCS DMP50pp
(NC + NC + NO)
/ /
XCS DMP59pp
(NC + NO)
XCSDMC79pp
XCSDMP79pp
XCSDMR79pp
XCSDMP70pp
NC + NC
NC + NC + NO
Characteristics
Ambient air temperature
Vibration resistance 10 gn (10-150 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 30 gn (11 ms) conforming to EN/IEC 60068-2-27
Protection against electric shock Class II conforming to EN/IEC 61140
Degree of protection : IP 66 + IP 67 : IP 67 Per IEC 60529
Degree of pollution 3, conforming to IEC / EN 60947-5-1
Ue = 24 V cRated operating characteristics Ie = 100 mA
Repeat accuracy 10 %
Hysteresis 20 %
Frequency of operating cycle 150 Hz
B10d 50 million cycles at 10mA
Drop out voltage 0.1 Vdc without LED; 2.4 Vdc with LED
1 Vdc without LED; 4.2 Vdc with LED
Cable connection M8 ; M12
Operation: - 13 °F to 185 °F (- 25…85 °C) / Storage: - 40 °F to 185 °F (- 40…85 °C)
Use cables with 4 or 6 conductors such as the M8 or M12 cables pictured here:
The minimum conductor wire size is 0.25 mm2 (24 AWG).
Typical cable lengths are 2 m, 5 m, and 10 m (6.6 ft, 16.4 ft, 32.8 ft).
Caractéristiques
Température de l’air ambiant Pour fonctionnement : - 25…85 °C / Pour stockage : - 40…85 °C
Tenue aux vibrations 10 gn (10…150 Hz) selon EN/IEC 60068-2-6
Tenue aux chocs 30 gn (durée 11 ms) selon EN/IEC 60068-2-27
Protection contre les chocs électriques Classe II selon EN/IEC 61140
Degré de protection : IP 66 + IP 67 : IP 67 suivant IEC 60529
Degré de pollution 3, selon IEC / EN 60947-5-1
Caractéristiques assignées d’emploi Ue = 24 V cIe = 100 mA
Reproductibilité 10 %
Hystérésis 20 %
Fréquence de commutation 150 Hz
B10d 50 millions de cycles à 10mA
Chute de tension 0,1 V c sans LED; 2,4 V c avec LED
1 V c sans LED; 4,2 V c avec LED
Raccordement M8 ; M12
Utiliser des câbles à 4 ou 6 conducteurs, tels que les câbles M8 ou M12 représentés ici :
Calibre minimal du fil : 0.25 mm2 (24 AWG).
Longueurs de câbles types : 2 m, 5 m, and 10 m.
Safety solutions using Preventa / Solutions de sécurité selon Preventa /
Sicherheitslösungen mit Preventa / Soluciones de seguridad según Preventa /
Soluzioni di sicurezza secondo Preventa / Soluções de segurança da Preventa
XCS DMC59pp
(NC)
(NO)
BN/BU
WH/BK
1/3
2/4
(mm/in.)
1
Sao
Sar
5/0.19
15/0.59
14/0.55
XCS DMC79pp
(NC)
(NC)
BN/BU
WH/BK
1/3
2/4
(mm/in.)
1
Sao
Sar
5/0.19
15/0.59
14/0.55
XCS DMP50pp
(NC)
(NO)
(NO)
BN/BU
GY/PK
WH/BK
1/3
6/7
2/4
(mm/in.)
1
Sao
Sar
8/0.31
20/0.78
14/0.55
XCS DMP70pp
(NC)
(NO)
(NC)
BN/BU
GY/PK
WH/BK
1/3
6/7
2/4
(mm/in.)
1
Sao
Sar
8/0.31
20/0.78
14/0.55
XCS DMP59pp
XCS DMR59pp
(NC)
(NO)
BN/BU
WH/BK
1/3
2/4
(mm/in.)
1
Sao
Sar
8/0.31
20/0.78
14/0.55
XCS DMP79pp
XCS DMR79pp
(NC)
(NC)
BN/BU
WH/BK
1/3
2/4
(mm/in.)
1
Sao
Sar
8/0.31
20/0.78
14/0.55
-Contact closed (1)
-Contact fermé (1)
-Kontakt geschlossen (1)
- Contacto cerrado (1)
- Contatto chiuso (1)
- Contacto fechado (1)
-Contact open (0)
-Contact ouvert (0)
-Kontakt geöffnet (0)
- Contacto abierto (0)
- Contatto aperto (0)
-Contacto aberto (0)
-Transient state
-Etat transitoire
-Übergangszustand
- Estado transitorio
- Stato transitorio
- Estado transitório
XCS DMC / DMP / DMR (EAC)
Sao : Assured Operating Distance
Sao : portée de travail assurée
Sao : gewährleisteter Arbeitsbereich
Sao : alcance de trabajo asegurado
Sao : zona di lavoro garantita
Sao : alcance de trabalho assegurado
Sar : Assured Release Distance
Sar : portée de déclanchement assurée
Sar : gewährleisteter Auslösebereich
Sar : alcance de activación asegurada
Sar : distanza minima per garantire l’intervento
Sar : alcance de activação assegurado
en
fr
5/6
AAV82775 06
www.tesensors.com
Contact status with magnet present
Etat des contacts en présence de l’aimant
Kontaktspiegel bei Magnetbetätigung
Estado de los contactos en presencia del imán
Stato dei contatti in presenza del magnete
Estado dos contactos em presença do ímã
Required Fusing Protection (using without safety module) 500 mA gG (gl) cartridge fuse
Protection par fusible nécessaire (utilisation hors module de sécurité) Cartouche fusible 500 mA gG (gl)
Características
Temperatura ambiente Funcionamento: - 25…85 °C Armazenagem: - 40…85 °C
Comportamento às vibrações 10 gn (10 ... 150 Hz) segundo EN/IEC 60068-2-6
Comportamento aos choques 30 gn (duração 11 ms) segundo EN/IEC 60068-2-27
Protecção contra os choques eléctricos Classe II segundo EN/IEC 61140
Grau de protecção : IP 66 + IP 67 : IP 67 Per IEC 60529
Grau de poluição 3, segundo IEC / EN 60947-5-1
Características estipuladas de emprego Ue = 24 V c Ie = 100 mA
Reprodutibilidade 10 %
Histeresis 20 %
Frequência de comutação
B10d
B10d
150 Hz
50 milhões de ciclos de 10mA
Queda de tensão 0,1 V c sem LED; 2,4 V c com LED
1 V c sem LED; 4,2 V c com LED
Ligações M8 ; M12
Utilize cabos com 4 ou 6 condutores, tais como os cabos M8 ou M12 aqui apresentados:
A dimensão mínima do fio condutor é de 0.25 mm2 (24 AWG).
Os comprimentos típicos dos cabos são de 2 m, 5 m, e 10 m.
XCS DMC / DMP / DMR (EAC)
Technische Daten
Umgebungstemperatur Betrieb : Lagerung : - 40…85 °C
Vibrationsfestigkeit 10 gn (10…150 Hz) gemäß EN/IEC 60068-2-6
Schockfestigkeit 30 gn (Dauer 11 ms) geß EN/IEC 60068-2-27
Schutz gegen Spannungstöße Klasse II gemäß EN/IEC 61140
Schutzart : IP 66 + IP 67 : IP 67 gemäß IEC 60529
Verschmutzungsgrad3, gemäß IEC / EN 60947-5-1
Ue = 24 V cNennbetriebsdaten Ie = 100 mA
Schaltgenauigkeit 10 %
Hysterese 20 %
Schaltfrequenz 150 Hz
B10d 50 Millionen Zyklen bei 10mA
Spannungsabfall 0,1 V c ohne LED; 2,4 V c mit LED
1 V c ohne LED; 4,2 V c mit LED
Elektrischer Anschluß
- 25…85 °C
M8 ; M12
Verwenden Sie Kabel mit 4 oder 6 Leitern, wie die hier
abgebildeten M8- oder M12-Kabel:
Minimale Größe des Leiterdrahtes: 0.25 mm2 (24 AWG).
Kabellängen in der Regel: 2 m, 5 m und 10 m.
Características
Temperaturas ambiente Para funcionamiento: - 25…85 °C Para almacenamiento: - 40…85 °C
Resistencia a las vibraciones 10 gn (10 ... 150 Hz) según EN/IEC 60068-2-6
Resistencia a los impactos 30 gn (duración 11 ms) según EN/IEC 60068-2-27
Protección contra las descargas eléctricas Clase II según EN/IEC 61140
Grado de protección : IP 66 + IP 67 : IP 67 conforme a la IEC 60529
Grado de contaminación 3, según IEC / EN 60 947-5-1
Características de uso
Reproductibilidad 10 %
Histéresis 20 %
Frecuencia de conmutación 150 Hz
B10d 50 millones de ciclos en 10mA
Caída de tensión 0,1 V c sin LED; 2,4 V c con LED
1 V c sin LED; 4,2 V c con LED
Conexión M8 ; M12
Utilizar cables con 4 o 6 conductores, como los cables M8 o M12 representados a continuación:
Calibre mínimo del hilo 0.25 mm2 (24 AWG).
Longitudes de cables estándares: 2 m, 5 m, y 10 m.
Ue = 24 V cIe = 100 mA
Caratteristiche
Temperatura ambiente Funzionamento: Stoccaggio: - 40…85 °C
Tenuta alle vibrazioni 10 gn (10 … 150 Hz) secondo EN/IEC 60068-2-6
Tenuta agli urti 30 gn (durata 11 mis) secondo EN/IEC 60068-2-27
Protezione contro gli choc elettrici Classe II secondo EN/IEC 61140
Grado di protezione : IP 66 + IP 67 : IP 67 Per IEC 60529
Grado d’inquinamento 3, secondo IEC / EN 60 947-5-1
Caratteristiche nominali d’impiego V 42 = eU Ie = 100 mA
Ripetibilità 10 %
Isteresi 20 %
Frequenza di commutazione 150 Hz
50 milioni di cicli a 10mA
Calo di tensione 0,1 V c senza LED; 2,4 V c con LED
1 V c senza LED; 4,2 V c con LED
Collegamento
- 25…85 °C
M8 ; M12
Usare cavi con 4 o 6 conduttori come i cavi M8 o M12 illustrati a seguito:
Le dimensioni minime del cavo conduttore sono di 0.25 mm2 (24 AWG).
Le lunghezze dei cavi sono di 2 m, 5 m e 10 m.
de
es
it
pt
6/6
AAV82775 06
www.tesensors.com
Erforderlicher Sicherungsschutz (Verwendung auβerhalb des Sicherheitsmodul) Sicherung 500 mA gG (gl)
Se requiere una protección por fusible
(utilización fuera del módulo de seguridad) Cartucho fusible 500 mA gG (gl)
Protezione con fusibili richiesta (senza modulo di sicurezza) Fusibile 500 mA gG (gI)
Protecção de Fusíveis Necessária (utilização sem módulo de segurança) Cartucho fusível 500 mA gG (gl)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Telemecanique Sensors XCSDMR791L01M12 Mode d'emploi

Catégorie
Éclairage de confort
Taper
Mode d'emploi