INSTALLATION INSTRUCTION
BLADE
WS-11511, 11522
WARNING
IMPORTANT: NEVER attempt any work without shutting off the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local
regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or
switch ”OFF” the circuit breaker switch(es) that control the power to the fixture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts
that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this fixture.
CAUTION When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en posi
tion d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, nen
laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler
l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression
à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta
lación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calificado, de acuerdo con el código eléctrico nacional
y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali
mentación principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la
instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calificación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la
base sólo.
HARDWARE A1 B1 C1 I1
Wire
Connector
Qty: 3
Mounting
Screw
Qty: 4 + 1 Extra
Screw
Qty: 2 + 1 Extra
Junction Box
Screw
Qty: 2 + 1 extra
Technology Upgraded
No Driver Required
Driver
(Please direct wire with 120V AC)
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2015
INSTALLATION INSTRUCTION
BLADE
WS-11511, 11522
PREPARATION
1. Shut off the power at the circuit breaker and remove
existing fixture, including the mounting hardware.
2. Carefully unpack your new fixture and lay out all the parts on a
clear area. Be careful not to lose any small parts
necessary for installation.
3. Remove the mounting screws (C1) from the fixture.
4. Connect the electrical wires as shown in Fig. 3, making sure
that all wire connectors are secured. Fixture and
junction box ground wires should be connected to
mounting plate using green screw provided. After wires
are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE
For Junction Box (Fig.1)
5. Secure the mounting ring (D1) to the junction box (F1) using
junction box screws (B1). Make sure the two holes (spacing
2-3/4”) are vertical direction as shown in Fig. 1.
6. Put the mounting plate (E1) and the conversation plate (G1)
onto the mounting ring (D1). Make sure the two holes on
mounting plate (E1), the two slots on
conversation plate (G1) and the two holes (spacing 2-3/4”)
are aligned. Fasten them using screws (I1).
For Switch Box (Fig.2)
7. Secure mounting plate (E1) to the switch box (F1)
using screws (B1). The side of the mounting plate marked
“GND” (E1) must face out.
8. Place the fixture back plate (H1) over the mounting plate (E1)
and secure with screws (C1).
H1
B1 C1
E1
A1
F1
I1 C1
E1
A1 G1
B1
D1
F1
FIG.2 - Switch box moutning
FIG.1 - Junction box mounting
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.3 Wiring
Screws
Fixture
Screw
Fixture
Screw
Mounting
Plate
Wire
Connector
Switch Box
Fixture
Screw
Mounting
plate
Wire
Connector
Conversation
plate
Screw
Mounting
Ring
Junction
Box
2 1/4”
4”
Ø3 1/4”
Ø2 3/4”
Back Plate Dimensions
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
OVERALL COMPONENT DIMENSIONS
CAUTION: TO PREVENT ELECTRICAL SHOCK, ENSURE ELECTRICITY HAS BEEN TURNED OFF AT THE CIRCUIT BREAKER BEFORE
BEGINNING.
-Read all instructions before installing.
-System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
-When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
-Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms
could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
MISE EN GARDE: POUR ÉVITER TOUT CHOC ÉLECTRIQUE, ASSUREZVOUS QUE LE DISJONCTEUR SOIT MIS HORS TENSION AVANT DE
COMMENCER.
-Lisez toutes les instructions avant l’installation.
-Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux règlements
locaux.
-Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec
les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus pour ce
produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
COMPONENT OVERVIEW
The trimless junction box cover is intended for installation to NEC approved 4” square junction boxes recessed in drywall and ush with the
support structure. It may be covered with spackle and/or plaster to conceal junction box visibility. It is to be connected to compatible Modern
Forms xtures. Refer to specications sheets for more information.
2"
#8
TYP
HARDWARE
Wire Connector
Qty: 3 (+1 Extra)
½” Plastic Spacer
Qty: 2
⁄”-40 x 1⁄” Long
Mounting Screw
Qty: 2 (+1 Extra)
¾” Plastic Spacer
Qty: 2
A
D
B
E
#8-32 x ¾” Long
Junction Box Screw
Qty: 2 (+1 Extra)
1” Plastic Spacer
Qty: 2
C
F
NOTE: This accessory is supplied with an optional mounting C-ring for
xture connection via ⁄” K.O. hole. This component may be omitted
from the installation if mounting xtures using #8 screw holes.
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIG. 1
FIG. 2
FIG. 4
TRIMLESS JUNCTION BOX COVER INSTALLATION:
The trimless junction box cover is compatible with NEC approved
4” square junction boxes recessed in drywall and ush with the
support structure.
1. Install compatible junction box (by others) to the framing
structure. Ensure the junction box is ush with the base or front
of framing structure (See FIG. 1).
2. Install the mounting plate to the junction box (See FIG. 2).
Ensure the spacer alignment base is facing outward.
FIG. 3
105mm
105mm
FIG. 5 FIG. 6
3. Determine the drywall thickness and select the appropriate
spacer to install between the mounting plate and the trimless
junction box cover (See FIG. 3).
NOTE: Only 1 matching pair of spacers are to be used per
installation.
4. Using the mounting screws provided, attach the trimless
junction box cover to the mounting plate (See FIG. 4).
5. Make a 4⁄” square cutout in drywall at the intended trimless
junction box cover location and proceed to install to framing
structure (See FIG. 5). Apply and nish spackle up to the center
hole of trimless junction box cover. Ensure #8 holes on the
cover are free of spackle. (See FIG. 6).
Mounting Plate
Plastic
Spacers
Trimless Junction Box Cover
Cover Mounting Screws
Ground Wire
Example: ½” Drywall (No Spacer)
⁄”½”
Spacer Alignment
Base
Spacer
Height
Drywall
Thickness
No Spacer ½”
½” ⁄”
¾” 1”
1” 1¼”
Junction Box
Screws
CB
D
E
F
3Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIXTURE INSTALLATION TO JUNCTION BOX COVER:
The trimless junction box cover features two #8 holes which may be used to mount xtures:
1. Make appropriate splice connections. Wiring may be placed inside the xture or pushed into the junction box.
2. Using #8 mounting screws supplied with the lighting xture, attach the xtures to the #8 holes on the trimless junction box cover. Apply
xture cover or lensing (where applicable) to complete the installation. (See FIG. 7).
Fixture #8 Mounting Screws
FIG. 7
Wire Connector