Tetra 12V GEPS12-25U-NA Signage Power Supply Guide d'installation

Taper
Guide d'installation
LED Systems Power Supply
Installation Guide
SIGN195 | GE2025-6710
Power Supply Features
Supports all 12 VDC Tetra Products
Dry and Damp Locations Rated
Class 2 Power Supply
120-277 VAC Input
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Disconnect power at fuse box or circuit breaker before servicing or
installing product.
Properly ground Tetra® power supply.
Must be enclosed in an end product.
RISK OF FIRE
In the end product, power supply spacing to other heat producing
components shall be minimum 2 inches spacing to sidewalls and
minimum 2 inches spacing to top of enclosure.
Adjacent power supplies shall be spaced at least 1 in. end to end
and 4 in. in any other direction.
Use only approved wire for input/output connection. Minimum size
18 AWG (0.82 mm2).
Follow all local codes.
Application considerations potentially requiring additional spacing
include high ambient temperature seen by the power supply, poor
contact with a heat dissipating material, inadequate ventilation, or
direct exposure to sun.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra®.
Doit être inclus à l’intérieur d’un produit final.
RISQUES D’INCENDIE
Dans le produit fini, l’espacement entre le bloc d’alimentation et les autres
composants dégageant de la chaleur doit être d’au moins 2 pouces des
parois latérales et d’au moins 2 pouces du haut de l’enceinte.
Les blocs d’alimentation adjacents doivent être espacés d’au moins 1 po
de bout en bout et 4 po dans toute autre direction.
N’utilisez que des fils approuvés pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82 mm2).
Respectez tous les codes locaux..
Certaines applications pourraient requérir un espacement additionnel, p.
ex. une température ambiante élevée autour du bloc d’alimentation, un
mauvais contact avec une matière dissipatrice de chaleur, une ventilation
inadéquate ou une exposition directe au soleil.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
Limited to use in dry and damp locations.
The suitability of rain enclosure shall be determined if
intended for wet location.
The grounding and bonding of the LED Driver shall
be done in accordance with National Electric Code
(NEC) Article 600.
Follow all National Electric Codes (NEC) and local
codes.
GEPS12-25U-NA (120-277 VAC input/12VDC output/25W)
1212
Volt
BEFORE YOU BEGIN
Read these instructions completely and carefully.
CAUTION / ATTENTION
RISK INJURY
While performing installations described, gloves, safety
glasses or goggles should be worn.
RISQUES DE BLESSURE
Lors de l’exécution des installations décrites, des gants, des lunettes
de sécurité ou des lunettes de protection doivent être portées.
Tetra® Power Supply GEPS12-25U-NA Installation Guide
2
Power Supply Installation
NOTE: For installation in Canada, a disconnect switch of appropriate rating needs to be placed within 29.5 feet (9 meters) of
primary side of the power supply. The switch voltage rating shall not be less than the branch circuit voltage. The switch must
also support twice the amount of input current.
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line, neutral
and ground connections, in accordance with National Electric Code (NEC) Article 600 and all local regulations.
Connect the AC line to the black
or brown (line) and white or
blue (neutral) input wires of the
power supply using suitable wire
connectors.
Connect the supply wire that is
attached to the Tetra LED System
to the red (+) and black or blue (-)
output wires of the power supply
as outlined in the “Electrical
Connections” section of your LED
system’s Installation Instructions.
NOTE: To avoid overloading this
power supply with LED modules,
please refer to the specific module
loading guides.
Input
wires
White or blue
(neutral)
Black or brown
(line)
AC line
To Tetra LED System
Output
wires
Red (+) Black or blue (-)
Mount the power supply. Mounting
the power supply base directly to
a thermally conductive installation
surface can improve thermal
performance.
NOTE: All electrical connections
should be suitably protected
from mechanical damage and the
environment. Seal all connections
exposed to water with electrical
grade self-hardening silicone.
OPTIONAL
A Weather Box (GEXNWB2) may be used to
house and seal Class 2 connections.
A) Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
B) Secure the weather box using a #6 or #8
(M2 or M3) screw.
Weather box
can be painted
Light engine
1 2 3
WARNING
RISK OF ELECTRIC SHOCK
AC input connections shall be
suitably enclosed.
A B
Tetra® Power Supply GEPS12-25U-NA Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 3 of 3
(Rev 06/19/23)
SIGN195 | GE2025-6710
Power Supply Specifications
Performance Data Min Typical Max
Input Voltage (VAC) 100 120-277 305
Input Frequency (Hz) 50/60
Input Current (A) 0.1 (277VAC) 0.3 (100VAC)
THD – 20
PF 0.9 –
Output Voltage (VDC) 11.0 12.0 13.0
Output Current (ADC) 2.0
Output Power (W) 25
Environmental Operating Temperature Range -25°C +25°C +50°C*
Environmental Humidity (non-condensing) 95%
Environmental Storage Temperature Range -10°C +70°C
Environmental Rating IP66 rated: must be protected from direct exposure to the weather
Dimensions 5.2 in. x 1.6 in. x 1.2 in. (133 mm x 30.5 mm x 40 mm)
Conforms to the following standards:
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
For the most up-to-date version of this installation guide, please visit https://products.LED.com/sign-lighting
*Maximum case temperature is 75°C
Symptom Solution
All letters are OFF Recycle AC power, turn it off, then turn on again.
If still off, check the power supply DC output voltage using a voltmeter. It should be nominally 12V.
» If there is DC output, inspect and correct all DC wire damage/polarity issues; If no issue is found, replace the
OFF-module string.
» If there is no DC output, have a licensed electrician check the input AC voltage and if there is correct AC voltage,
replace the power supply.
» If there is no AC voltage, correct the upstream AC issue.
Some LEDs appear dim Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Some of the letters
are not illuminated
Inspect and correct the wires of the non-illuminated letters for damage/polarity issues; If no issues are found, see the
troubleshooting solution for “All letters are OFF.”
Shadows Re-route supply wire and secure to the back of the can with electrical grade RTV silicone. Adjust wire connector
orientation so that it does not cover any LEDs.
Adjust LED layout to ensure uniformity of illumination of the face of the letter.
Troubleshooting
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
  • Page 1 1
  • Page 2 2
  • Page 3 3

Tetra 12V GEPS12-25U-NA Signage Power Supply Guide d'installation

Taper
Guide d'installation