Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
Limited to use in dry and damp locations.
The grounding and bonding of the LED Driver shall be done in
accordance with National Electric Code (NEC) Article 600.
Follow all National Electric Codes (NEC) and local codes.
These products are only suitable for connection to a circuit from
a Class 2 power source. These products have not been evaluated
for use when connected to a power source that does not comply
with Class 2 voltage and energy limited supplies.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN
ACCORDANCE WITH KIT INSTRUCTIONS.
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY THE
INSTRUCTIONS ARE PRESENT.
TROUSSE DE CONVERSION À DEL POUR LA
MODERNISATION DES ENSEIGNES
À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power off before inspection, installation or removal.
Properly ground power supply enclosure.
RISK OF FIRE
Use only UL approved wire for input/output connections.
Minimum size 18 AWG (0.82mm2)
Follow all NEC and local codes.
Not to be submerged or used in a marine environment.
RISK OF FIRE OR ELECTRIC SHOCK
LED Retrofit Kit installation requires knowledge of
sign electrical systems. If not qualified, do not attempt
installation. Contact a qualified electrician.
Install this kit only in host signs that have been identified in
the installation instructions and where the input rating of the
retrofit kit does not exceed the input rating of the sign.
Installation of this LED retrofit kit may involve drilling or
punching of holes into the structure of the sign. Check
for enclosed wiring and components to avoid damage to
wiring and electrical parts.
Do not make or alter any open holes in an enclosure of
wiring or electrical components during kit installation.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
Assurez-vous de correctement mettre à terre l’alimentation électrique.
RISQUES D’INCENDIE
N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82mm2)
Respectez tous les codes NEC et codes locaux.
Ne pas submerger ou installer dans un environnement marin.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE
L’installation de l’équipement de remplacement DEL exige Ia connaissance des
systèmes électriques pour enseignes. Si non qualifié, ne tentez pas d’installation.
Veuillez contacter un électricien qualifié.
Risque d’incendie ou de choc Électrique. Installez cet ensemble seulement dans des
enseignes hôtes qui ont été identifiés dans les instructions d’installation et dont la
capacité d’entrée de l’ensemble ne dépasse pas la capacité d’entrée de l’enseigne.
L’installation de cet équipement de remplacement DEL peut impliquer le perçage
ou le poinçonnage de trous dans la structure du panneau Vérifiez le câblage et
les composants inclus pour éviter d’endommager le câblage et les composants
électriques.
Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage ou de
composants électriques pendant l’installation de cet équipement de remplacement DEL.
2424
Volt
GESS2471-2, GESS2450-2, GESS2441-2, GESS2432-2,
GESS24H71-2, GESS24H50-2, GESS24H41-2, GESS24H32-2
BEFORE YOU BEGIN
Read these instructions completely and carefully.
CAUTION / ATTENTION
RISK INJURY
While performing installations described, gloves, safety glasses or
goggles should be worn.
RISQUES DE BLESSURE
Lors de l’exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
Tetra® PowerStrip Installation Guide
2
Electrical grade RTV silicone.
Example electrical grade RTV silicones include:
Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant
Momentive White Blanc RTV 162 Silicone Rubber Adhesive Sealant-Electrical Grade
Dow Corning 3140 - Non-Corrosive Flowable (clear)
Dow Corning 3145 - Non-Corrosive Nonflowable (clear or gray)
Dow Corning RTV 748 Non-Corrosive Sealant-White
Peel off backing to expose
adhesive tape.
Mark row spacing guidelines so
that modules are spaced evenly
inside and from edges of sign.
Determine how many modules are
required for one row and cut wire.
Layout Recommendations
NOTE: Minimum recommended sign depth is 5 inches (127mm).
Tetra Module Depth Stroke Width Mod to Mod Spacing
Single Sided
PowerStrip and
Single Sided
Powerstrip High
Output
5-6” (127-152mm) 10” (254mm) 12” (305mm)
6-7” (152-178mm) 12” (305mm) 12” (305mm)
7-8” (178-203mm) 13” (330mm) 12” (305mm)
8-9” (203-229mm) 14” (356mm) 12” (305mm)
9-10” (229-254mm) 15” (381mm) 12” (305mm)
10-11” (254-279mm) 16” (406mm) 12” (305mm)
11-12” (279-305mm) 17” (432mm) 12” (305mm)
Powerstrip SS HO 12-18” (305-457mm) 18” (457mm) 12” (305mm)
18” (457mm) 12” (305mm) 12” (305mm)
Row
spacing
Sign
depth
Components
UL certified 18 AWG (0.82 mm2)
supply wire
UL certified 22-14 AWG (0.33-2.08 mm2)
wire connectors or 22-18 AWG
(0.33-0.82 mm2) inline/IDC connectors
#6 or #8 (M3 or M4) screws, 1/8 inch
(3.2mm) rivets
End caps
24 Volt Power Supply
Optional
Tetra® Mounting Rail
Tetra® Assembly Bracket or Mounting
Rail Clip
Tetra® Angle Mounting Clips and
Extender Rod
Installation: Sign Without Rails
Secure with at least one screw per
module with #6 or #8 (M3 or M4)
screws or 1/8-inch rivets (3.175 mm),
silicone or equivalent.
Position string of modules ene to
end along guidelines inside of sign.
Evenly space modules by arranging
approximately one module per
12 in. (305mm).
TC Measure Point
Tetra® PowerStrip SS MO LED modules
Tetra® PowerStrip SS High Output LED
modules
2
5
1
4
3
1
1
7
7
8
8
9
9
10
10
11
11
2
2
3
3
4
4
5
5
6
6
Tetra® PowerStrip Installation Guide
3
Electrical Connections
Run a wire from the power supply
to inside the sign and connect to
the first module on the strip.
NOTE: Exceeding maximum load
will cause the power supply to shut
down. If overload occurs, remove
excess load, recycle the input power
to restart the power supply.
Connect modules using twist-on
wire connectors or in-line (IDC)
connectors. Join white wires together
and red striped wires together.
NOTE: Additional supply wire may
be necessary to bridge electrical
connections.
Cap all exposed wires with
appropriate end caps or apply
electric grade (non-corrosive) silicone
for additional weather protection.
Red stripe (+)
White (-)
Power
Supply
To LED System
Red (+)
Black or blue (-)
Connect the red stripe wire (+) of
the LED system to the red wire (+)
of the power supply. Connect the
white wire (-) of the LED system
to the black or blue wire (-) of the
power supply.
NOTE: Do not use connectors pre-lled with silicone grease/mineral base protective grease or use silicone grease to seal connections.
To Power Supply
Red (+)
Red stripe (+)
White (-)
Black or
blue (-)
Measure and cut Tetra® Mounting
Rail or other suitable mounting
means to appropriate length to fit
into sign.
Secure the Mounting Rail to the
inside of the box sign using a
Tetra® Mounting Rail Clip or other
suitable mounting means. Ensure
the #6 (M3) screw does not exceed
3/4 inches (19 mm) in length.
Installation: Sign Using Rails
Sign
Tetra® Mounting Rail
Measure inside
Arrange modules evenly spaced
apart. Place the Tetra® modules
on the Mounting Rail and secure
into lip with a self-tapping #6 (M3)
screw or 1/8-inch (3.175 mm) rivet.
Or mount using the alternative clip
and extender rod configuration.
Alternative clip
and extender rod
NOTE: All electrical connections should be suitably protected from
mechanical damage and the environment. Seal all connections in locations
that may be exposed to water with electrical grade RTV silicone.
2
2
4
1
1
3
3
Tetra® PowerStrip Installation Guide
4
Troubleshooting
Dismantling
Symptom Solution
Row of modules does not light Check wire connections to power supply to ensure red stripe-to-red and white-to-black or blue
connections.
Check row-to-row polarity connections.
Sign does not light Check input and output voltage and check power supply input/output connections.
Check polarity connections.
Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
Individual modules do not light Remove module and replace with another working module.
Modules are dim Ensure the overall length of the Tetra® LED system does not exceed the maximum load.
Ensure the length and gauge of the supply wire is equal to or below the recommended remote
mounting distance.
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the
building. Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED
power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes
(whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and
associated transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.
NOTE: Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable
local, state, or country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in)
diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed
with non-hardening caulk.
5. (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is
chosen. Follow the manufacturer’s directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area
where you intend to mount the module. Before installing, ensure the surface is dry.
6. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7. A 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Using the Maximum Loading chart below,
determine the number of Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to
overload the Power Supply chosen.
8. Follow the instructions above to properly mount the LED modules.
9. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions
found in the power supply installation guide.
11. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, and country
electrical codes.
Retrofit Instructions
At the end of life, the contained LED light source may be cut out using suitable wire cutters, removed from the mounting surface,
then replaced per the cutting and installation instructions above, or dismantled and taken to a communal collecting point for
environmentally friendly disposal in accordance with local regulations by a professional installer.
Tetra® PowerStrip Installation Guide
Power Supply
Wattage
18 AWG/0.82 mm2
Supply Wire
16 AWG/1.31 mm2
Supply Wire
14 AWG/2.08 mm2
Supply Wire
12 AWG/3.31 mm2
Supply Wire
25W 120 ft./36.6 m
60W, 80W, 100W,
180W, 200W, 300W 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly
disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable.
Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.
This product is intended solely for sign use only. Not intended for general lighting applications.
Conforms to the following standards:
If you have any questions about these instructions or your specific application, please contact support at [email protected].
For the latest install guides for your product go to: www.LED.com/tetra
Maximum Remote Mounting Distance
NOTE: The maximum loading claimed in the table is at ambient temperature 25°C (77°F).
For linear long runs, center connection to the LED strip is recommended to minimize voltage drop.
*GELP24-60U-GL minimum load = 8 GESS24xx-2 modules; or 7 GESS24Hxx-2 modules.
**GEPS24V50-100W minimum load = 20 GESS24xx-2 modules; or 17 GESS24Hxx-2 modules.
Maximum Loading per 24 VDC Class 2 Power Supply
Power Supply
GESS2471-2, GESS2450-2,
GESS2441-2, GESS2432-2
GESS24H71-2, GESS24H50-2,
GESS24H41-2, GESS24H32-2
Rating per module 24V DC, 105mA/module,
2.52W/module
24V DC, 123mA/module,
2.95W/module
GEPS24-25U-NA
Load shall not exceed 1.04A 9 modules 6 modules
GEPS24D-60U-GLX, *GELP24-60U-GL
Load shall not exceed 2.5A 21 modules 18 modules
GEPS24D-80U, GEPS24W-80
Load shall not exceed 3.3A 30 modules 22 modules
GEPS24-100U-GLX, GEPS24D-100U-NA, GEPS24LT-100U-NA,
USVI-100024FBA, USVI-100024FE
Load shall not exceed 4.0A
36 modules 30 modules
GEPS24-180U
Load shall not exceed 3.8A per each (of 2) output channels
33 modules per bank
66 modules per PS
26 modules per bank
52 modules per PS
GEPS24-300U-GL
Load shall not exceed 4.0A per each (of 3) output channels
36 modules per bank
108 modules per PS
30 modules per bank
90 modules per PS
GEPS24-100U-GLX2/TT, **GEPS24V50-100W
Load shall not exceed 4.0A 36 modules 30 modules
GEPS24-200U-GLX2
Load shall not exceed 4.0A per each (of 2) output channels
36 modules per bank
72 modules per PS
30 modules per bank
60 modules per PS
GEPS24-300U-GLX2
Load shall not exceed 4.0A per each (of 3) output channels
36 modules per bank
108 modules per PS
30 modules per bank
90 modules per PS
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 5 of 5
(Rev 06/06/23)
SIGN066 | GE2028-2617
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Tetra PowerStrip SS LED Signage Guide d'installation

Taper
Guide d'installation

dans d''autres langues