Flux F414 Mode d'emploi

Taper
Mode d'emploi
Originalanhang
Original attachment
Annexe originale
Drehstrom-
Getriebemotor
F 414
Seite 3 - 5
Three-phase
gearmotor F 414
Page 6 - 8
Moteur triphasé à
multiplicateur de
vitesse F 414
Page 9 - 11
2 / 16 Anhang Drehstromgetriebemotor F 414
Achtung
Lesen Sie die allgemeine Betriebsanleitung für Fass- und Container-
pumpen und die mitgelieferten produktspezifischen Anhänge, bevor
Sie die Pumpe in Betrieb nehmen!
Lesen Sie vor dem Fördern brennbarer Flüssigkeiten bzw. bei Ver-
wendung des Motors oder der Pumpe im explosionsgefährdeten
Bereich unbedingt den Anhang „Explosionsschutz Fass- und
Containerpumpen“.
Attention
Read the main operating instructions for drum and container
pumps and the included product-specific attachments before
operating the pump!
Before pumping flammable liquids or when using the motor or
the pump in a hazardous area, be sure to read the attachment
"Ex-protection drum and container pumps".
Attention
Lisez la notice d‘instructions générale pour les pompes vide-fûts
ainsi que les annexes spécifiques aux produits avant de mettre
la pompe en service !
Lisez impérativement l'annexe « Pompes vide-fûts antidéflagrantes »
avant de pomper des liquides inflammables ou d'utiliser le moteur
et la pompe dans une zone à risque d’explosion.
Anhang Drehstromgetriebemotor F 414 3 / 16
DEUTSCH
1 Sicherheit
1.1 Bestimmungsgemäße Verwendung
Der Drehstrom-Getriebemotor F 414 dient dem Antrieb von Fasspumpen zum
schnellen und sicheren Entleeren oder Umfüllen von Behältern, Fässern und
Containern in nicht explosionsgefährdeten Bereichen.
1.2 Sicherheitshinweise
Alle Sicherheitshinweise müssen beachtet und befolgt werden.
Das Nichtbeachten der Sicherheitshinweise kann das Leben und die Gesundheit von
Personen gefährden, zu Umweltschäden und/oder zu umfangreichen Sachschäden
führen.
Die Beachtung der Sicherheitshinweise in der Betriebsanleitung hilft, Gefahren zu
vermeiden und den vollen Produktnutzen zu sichern.
Achtung!
Verletzungsgefahr durch freilaufende Antriebswelle.
Motoren nie ohne Pumpe betreiben.
Pumpe nicht unbeaufsichtigt lassen.
Pumpe so aufstellen, dass sie nicht in den Behälter fallen kann.
Pumpe nur mit geeignetem Schlauch betreiben.
Pumpe nur bis unterhalb des Druckstutzens in die Flüssigkeit
eintauchen.
Schlauch gegen Abrutschen vom Schlauchstecker sichern.
Lärmbelastung!
Gehörschutz benutzen.
Achtung!
Wird der Motor im ferngesteuerten Betrieb verwendet, den Motor
gegen unbeabsichtigtes Anlaufen sichern. Der Motor läuft nach
einem Netzausfall automatisch wieder an.
Achtung Materialschäden!
Vor Inbetriebnahme die Drehrichtung des Motors prüfen (Dreh-
richtung gemäß Drehrichtungspfeil am Motor).
Gefahr Elektrischer Schlag!
Wir empfehlen die Spannungsversorgung in Feuchträumen mit
FI-Schutzschalter auszustatten.
Starke Verschmutzung, hohe Luftfeuchtigkeit oder Materialzer-
störung des Motorgehäuses kann zu gefährlichen Stromschlägen
führen.
Prüfen Sie das Netzanschlusskabel vor jeder Benutzung auf
Beschädigung.
Änderungen des Netzanschlusses nur durch Elektro-Fachkräfte.
2 Motorenbeschreibung
Der Drehstrom-Getriebemotor F 414 ist für Einsatzbedingungen mit erhöhter
Einschaltdauer geeignet.
4 / 16 Anhang Drehstromgetriebemotor F 414
DEUTSCH
3 Technische Daten
Motor
Typ Motorart Aufnahme-
leistung
Span-
nung
Fre-
quenz
Schutz-
art
Schutz-
klasse Gewicht
F 414
Drehstrom-
getriebemotor,
außenbelüftet
0,55 kW
0,75 kW
1,1 kW
230 V
400 V 50 Hz IP 55 I
8,8/8,0 kg
11,3/10,5 kg
12,8/12,0 kg
Umgebungstemperatur -20°C - + 40°C
4 Transport
Hinweis
Die Lüfterhaube am Drehstrommotor ist nicht als Griff für den
Transport geeignet.
5 Montage und Inbetriebnahme
5.1 Sicherheitshinweise für die Erstinbetriebnahme
Achtung Materialschäden!
Wird der Motor im ferngesteuerten Betrieb verwendet, den Motor
gegen unbeabsichtigtes Anlaufen sichern. Der Motor läuft nach
einem Netzausfall automatisch wieder an.
Vor dem Einstecken des Netzsteckers Ein/Aus-Schalter auf "0"
(Stopp) stellen.
Gefahr
elektrischer Schlag!
Wir empfehlen die Spannungsversorgung in Feuchträumen mit
FI-Schutzschalter auszustatten.
Starke Verschmutzung, hohe Luftfeuchtigkeit oder Materialzer-
störung des Motorgehäuses kann zu gefährlichen Stromschlägen
führen.
Drehstrommotoren nur mit vorgeschaltetem Motorschutzschalter
in Betrieb nehmen.
Mit Installationsarbeiten an Drehstrommotoren dürfen nur Fach-
kräfte beauftragt werden.
Prüfen Sie das Netzanschlusskabel vor jeder Benutzung auf
Beschädigung.
Änderungen des Netzanschlusses nur durch Elektro-Fachkräfte.
Zusätzliche Sicherheitshinweise im Klemmkasten des Dreh-
strom-Getriebemotors beachten.
Achtung Materialschäden!
Vor Inbetriebnahme die Drehrichtung des Motors prüfen
(Drehrichtung gemäß Drehrichtungspfeil am Motor).
Anhang Drehstromgetriebemotor F 414 5 / 16
DEUTSCH
6 Instandhaltung
Gefahr durch Verspritzen der Flüssigkeit!
Vor dem Abnehmen des Motors:
Pumpe, Schlauch und Armaturen entleeren.
Bei Gegendruck den Motor nicht abnehmen.
Bei unter Druck stehendem Behälter darf der Motor erst
abgenommen werden, wenn der Behälter drucklos ist.
Gefahr elektrischer Schlag!
Starke Verschmutzung, hohe Luftfeuchtigkeit oder Materialzerstö-
rung des Motorgehäuses können zu gefährlichen Stromschlägen
führen.
Hinweis
Defekte Teile grundsätzlich ersetzen.
Verwenden Sie Originalersatzteile.
Rücksendungen und Reparaturen werden über unsere Home-
page www.flux-pumps.com abgewickelt (RMA-Formular unter
„Service“).
6.1 Ersatz/Änderung der Netzanschlusskabel
Achtung!
Defekte Netzanschlusskabel grundsätzlich ersetzen.
Änderungen am Netzanschlusskabel und Ersatz des Netzan-
schlusskabels dürfen nur von Elektrofachkräften durchgeführt
werden.
Beim Ersatz/Änderung der Netzanschlusskabel mindestens folgende Ausführungen
verwenden:
Motor Netzspannung
230 V – 400 V
F 414 H 07 RN-F 5G 1,5
6 / 16 Attachment three-phase gear motor F 414
ENGLISH
1 Safety
1.1 Intended use
The three-phase gear motor F 414 is used to drive drum pumps for fast, safe draining
or transferring of containers and drums in non-hazardous areas.
1.2 Safety instructions
All safety instructions must be observed and followed.
Failure to follow the safety instructions may lead to serious injury or death or cause
environmental and/or property damage.
Adherence to the safety instructions will help you to avoid risks, to operate the pump
efficiently and to ensure that the product is used to its full potential.
Attention!
Risk of injury due to open drive shaft.
Never operate motors without pump.
Never leave the pump unattended.
Position the pump to prevent it from falling into the container.
Only operate the pump with a suitable hose.
The pump should not be immersed deeper into the liquid than
the outlet connection.
Secure the hose from sliding off the hose connector.
Noise exposure!
Use hearing protection.
Attention!
If the motor is used in remote-controlled operation, secure the
motor against accidental start-up. The motor automatically re-
starts after a power failure.
Attention - material damage!
Check the direction of rotation of the motor before start-up
(direction of rotation according to the arrow on the motor).
Danger of electric shock!
We recommend providing the power supply in damp locations
with fault current breakers.
Dirt, high humidity or material damage to the motor casing may
lead to dangerous electric shocks.
Only start three-phase motors with an upstream motor-protec-
tion switch installed.
Only qualified personnel may carry out installation work on
three-phase motors.
Check the mains connection cable for damage before every use.
Only qualified electricians may carry out changes to the mains
connection.
2 Description of motor
The three-phase gear motor F 414 is suitable for operating conditions under which the
pump has an increased operating duration.
Attachment three-phase gear motor F 414 7 / 16
ENGLISH
3 Technical specifications
Motor
Type
Kind of
motor
Power
output Voltage Fre-
quency
Degree
of pro-
tection
Pro-
tection
class
Weight
F 414
Three-phase
gearmotor,
externally
cooled
0.55 kW
0.75 kW
1.1 kW
230 V
400 V 50 Hz IP 55 I
8.8/8.0 kg
11.3/10.5 kg
12.8/12.0 kg
Surrounding temperature -20°C - + 40°C
4 Transport
Note!
The fan hood on the three-phase gearmotor is not suitable for use
as a handle during transport.
5 Installation and Commissioning
5.1 Safety instructions for initial operation
Attention - material damage!
If the motor is used in remote-controlled operation, secure the
motor against accidental start-up. The motor automatically re-
starts after a power failure.
Set the ON/OFF switch to "0" (Stop) before connecting the mains
plug.
Danger of electric shock!
We recommend providing the power supply in damp locations
with fault current breakers.
Dirt, high humidity or material damage to the motor casing may
lead to dangerous electric shocks.
Only start three-phase motors with an upstream motor-protection
switch installed.
Only qualified personnel may carry out installation work on
three-phase motors.
Check the mains connection cable for damage before every use.
Only qualified electricians may carry out changes to the mains
connection.
Attention - material damage!
Check the direction of rotation of the motor before start-up
(direction of rotation according to the arrow on the motor).
8 / 16 Attachment three-phase gear motor F 414
ENGLISH
6 Maintenance
Danger from splashing liquids!
Before removing the motor:
Empty pump, hose and fittings.
Do not remove the motor as long as there is still back-pressure
within the system.
With pressurised containers, the motor must only be taken off
when the container is depressurised.
Danger of electric shock!
Dirt, high humidity or material damage to the motor casing may lead
to dangerous electric shocks.
Note!
Damaged parts must be replaced with new ones.
Only use genuine spare parts.
Returns and repairs are processed via our homepage
www.flux-pumps.com (RMA form under “Service”).
6.1 Replacing power cable
Attention!
Always replace defective mains connection cables.
Only qualified electricians may carry out changes to the mains
connection.
When replacing power cables, use at least the following types:
Motor Supply voltage
230 V – 400 V
F 414 H 07 RN-F 3G 1.5
Annexe moteur triphasé F 414 9 / 16
FRANÇAIS
1 Sécurité
1.1 Utilisation conforme
Le moteur triphasé avec multiplicateur F 414 sert à entraîner des pompes vide-fûts
permettant de transvaser ou de vider, rapidement et en toute sécurité, des fûts et
d’autres contenants dans des zones ne présentant pas de risque d’explosion.
1.2 Consignes de sécurité
Observer et suivre impérativement toutes les consignes de sécurité.
Le non-respect des consignes de sécurité peut mettre la vie de personnes en danger,
dégrader l'environnement et/ou causer de graves dégâts matériels.
Le respect des consignes de sécurité permet la prévention des risques, l’utilisation
efficace de la pompe ainsi que l’économie de vos opérations de transfert.
Attention !
Risque de blessure par la rotation libre de l'arbre d'entraînement.
Ne jamais faire fonctionner les moteurs sans pompe.
Ne pas laisser la pompe sans surveillance.
Placer la pompe de façon à ce qu'elle ne puisse pas tomber
dans le contenant.
Ne faire fonctionner la pompe qu'avec un flexible approprié.
Plonger la pompe dans le liquide en veillant à ce que le raccord
du tuyau de refoulement ne soit pas immergé.
Bien fixer le flexible pour l'empêcher de se détacher de son
raccord.
Nuisance sonore !
Utiliser un casque anti-bruit.
Attention !
Protéger le moteur contre toute remise en marche involontaire
quand il est utilisé avec une commande à distance. Le moteur se
remet automatiquement en marche après une panne du secteur.
Avant d'effectuer la mise en service, vérifier le sens de rotation
du moteur (rotation dans le sens de la flèche figurant sur le mo-
teur).
Risque de décharge électrique !
Nous recommandons d'équiper l'alimentation en tension des
locaux humides d'un disjoncteur différentiel.
Un encrassement prononcé, une grande humidité ou un endom-
magement des matériaux du carter de moteur peuvent provoquer
des décharges dangereuses.
Ne mettre en service des moteurs triphasés qu'en présence en
amont d'une protection par disjoncteur.
Seules des personnes spécialisées pourront être chargées
d'effectuer des travaux d'installation de moteurs triphasés.
Vérifier que le câble d'alimentation secteur est en parfait état
avant chaque utilisation.
Seuls des électriciens ont le droit de procéder à des modifica-
tions au niveau d’un branchement sur le secteur.
10 / 16 Annexe moteur triphasé F 414
FRANÇAIS
2 Description du moteur
Le moteur triphasé à multiplicateur de vitesse F 414 convient aux conditions d'utilisation
de longue durée.
3 Caractéristiques techniques
Type Construction Puissance
maxi. Tension Fréquence Protec-
tion
Classe
de pro-
tection
Poids
F 414
Moteur tri-
phasé avec
multiplicateur,
à ventilation
extérieure
0,55 kW
0,75 kW
1,1 kW
230 V
400 V 50 Hz IP 55 I
8,8/8,0 kg
11,3/10,5 kg
12,8/12,0 kg
Température ambiante : -20°C à +40°C
4 Transport
Information
Le capot ventilateur du moteur triphasé à multiplicateur de vitesse
ne doit pas servir de poignée pour le transport.
5 Montage et mise en service
5.1 Consignes de sécurité pour la première mise en service
Attention : dommages matériels !
Protéger le moteur contre toute remise en marche involontaire
quand il est utilisé avec une commande à distance. Le moteur se
remet automatiquement en marche après une panne du secteur.
Placer l'interrupteur Marche/Arrêt sur « 0 » (stop) avant de bran-
cher la fiche de secteur
Risque de décharge électrique !
Nous recommandons d'équiper l'alimentation en tension des
locaux humides d'un disjoncteur différentiel.
Un encrassement prononcé, une grande humidité ou un endom-
magement des matériaux du carter de moteur peuvent provoquer
des décharges dangereuses.
Ne mettre en service des moteurs triphasés qu'en présence en
amont d'une protection par disjoncteur.
Seules des personnes spécialisées pourront être chargées
d'effectuer des travaux d'installation de moteurs triphasés.
Vérifier que le câble d'alimentation secteur est en parfait état
avant chaque utilisation.
Seuls des électriciens ont le droit de procéder à des modifica-
tions au niveau d’un branchement sur le secteur.
Annexe moteur triphasé F 414 11 / 16
FRANÇAIS
Attention !
Avant d'effectuer la mise en service, vérifier le sens de rotation
du moteur (rotation dans le sens de la flèche figurant sur le
moteur).
6 Entretien
Danger provoqué par les éclaboussures !
Avant de séparer le moteur :
Vider la pompe, le flexible et la robinetterie.
Ne pas retirer le moteur en cas de contre-pression.
En cas de contenant sous pression, le mettre hors pression
avant de retirer le moteur.
Risque de décharge électrique !
Un encrassement prononcé, une grande humidité ou un endomma-
gement des matériaux du carter de moteur peuvent provoquer des
décharges dangereuses.
Remarques
Les pièces défectueuses doivent toujours être remplacées.
Utiliser des pièces d'origine.
Si la pompe doit être expédiée pour être réparée, elle devra
toujours être accompagnée d'un certificat de décontamination
( à télécharger à l'adresse : www.flux-pumps.com).
6.1 Remplacement des câbles d'alimentation
Attention !
Remplacer immédiatement tout câble d'alimentation défectueux.
Seuls des électriciens ont le droit de procéder à des modifica-
tions du câble d'alimentation secteur.
Remplacer les câbles d'alimentation par les modèles suivants ou de qualité supérieure :
Moteur Tension secteur
230 V – 400 V
F 414 H 07 RN-F 5G 1,5
12 / 16 F 414
7 EU Konformitätserklärung
EU Declaration of Conformity
Déclaration de conformité
F 414 13 / 16
7.1 UKCA Declaration of Conformity
14 / 16 F 414
F 414 15 / 16
FB 10-98000007_04 0523/20 DEF
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Flux F414 Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues