RE322 DSC-Compatible NanoMax Door / Window
Features
For sensing things that open or separate.
Magnet and Internal reed switch operation.
1-inch magnet gap!
External Contact.
Cover tamper.
Strong, reliable RF signal.
6+ year battery life on CR1632 battery.
Low Battery indication.
Key Instructions
Battery “+” faces up.
Enrolling:
Place control panel in Learn Sensor Mode
Open cover to tamper device, or
Tamper enrollment signal can be sent by touching a
magnet to the sensor 5 times within 5 seconds
Operation
Magnetic and hardwire zone
Alarm, when…
… magnet is pulled away from reed switch or
… hardwire changes to alarm.
Tamper, when cover is opened.
Supervisories, every hour.
Specifications
Magnet trip distance: 1 inch nominal
Mounting fastener: 3M VHB (Very High Bond) Tape
Replacement Battery: CR1632
Temperature Range: 0F to 120F
Housing dimensions: 1.8 x .77 x .39 inches
Specifications subject to change without notice.
RE322_DSC-Compatible_NanoMax_Instructions-DoubleSided 15-Aug-14
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Wireless
Security
Solutions
RE322 DSC-Compatible NanoMax Door / Window
Features
For sensing things that open or separate.
Magnet and Internal reed switch operation.
1-inch magnet gap!
External Contact.
Cover tamper.
Strong, reliable RF signal.
6+ year battery life on CR1632 battery.
Low Battery indication.
Key Instructions
Battery “+” faces up.
Enrolling:
Place control panel in Learn Sensor Mode
Open cover to tamper device, or
Tamper enrollment signal can be sent by touching a
magnet to the sensor 5 times within 5 seconds
Operation
Magnetic and hardwire zone
Alarm, when…
… magnet is pulled away from reed switch or
… hardwire changes to alarm.
Tamper, when cover is opened.
Supervisories, every hour.
Specifications
Magnet trip distance: 1 inch nominal
Mounting fastener: 3M VHB (Very High Bond) Tape
Replacement Battery: CR1632
Temperature Range: 0F to 120F
Housing dimensions: 1.8 x .77 x .39 inches
Specifications subject to change without notice.
RE322_DSC-Compatible_NanoMax_Instructions-DoubleSided 15-Aug-14
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Internal Picture
Notices
“GE”, “Honeywell”, “DSC”, “2GIG” and “Napco” are trademarks owned by General Electric Company,
Honeywell International Inc., Tyco Safety Products Canada LTD, 2GIG Technologies Inc., and NAPCO
Security Systems, Inc., respectively.
Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems.
However, no Resolution product is produced by, endorsed by, nor is officially associated with GE,
Honeywell or DSC. Resolution recommends verifying proper enrollment and operation, per control panel
installation instructions, at installation.
Warranty
Resolution Products, Inc. will replace products that are defective in their first five (5) years.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the Resolution Products, Inc. could void the
user's authority to operate this equipment.
FCC ID: U5X-RE322
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1)This device may not cause interference, and
(2)This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1)l'appareil ne doit pas produire de brouillage, et
(2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC: 8310A-RE322
External
Contact
Connection
Magnetic
Reed
Switch
Battery
Bucket
RE322_DSC-Compatible_NanoMax_Instructions-DoubleSided 15-Aug-14
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Internal Picture
Notices
“GE”, “Honeywell”, “DSC”, “2GIG” and “Napco” are trademarks owned by General Electric Company,
Honeywell International Inc., Tyco Safety Products Canada LTD, 2GIG Technologies Inc., and NAPCO
Security Systems, Inc., respectively.
Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems.
However, no Resolution product is produced by, endorsed by, nor is officially associated with GE,
Honeywell or DSC. Resolution recommends verifying proper enrollment and operation, per control panel
installation instructions, at installation.
Warranty
Resolution Products, Inc. will replace products that are defective in their first five (5) years.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the Resolution Products, Inc. could void the
user's authority to operate this equipment.
FCC ID: U5X-RE322
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1)This device may not cause interference, and
(2)This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1)l'appareil ne doit pas produire de brouillage, et
(2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC: 8310A-RE322
External
Contact
Connection
Magnetic
Reed
Switch
Battery
Bucket
  • Page 1 1
  • Page 2 2

Alula NanoMax RE322 Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues