Feit Electric UCL18FP/5CCTCAG3 Flat Panel Under Cabinet Light Guide d'installation

Taper
Guide d'installation
Model: UCL18FP/5CCTCAG3
READ BEFORE INSTALLATION
SAVE THESE INSTRUCTIONS
Questions, problems, missing parts? Before returning to the store,
call Feit Electric Customer Service
8 a.m. - 5 p.m., PST, Monday - Friday
We appreciate the trust and confidence you have placed in Feit Electric through the purchase of this Under Cabinet Light. We strive to continually create quality products
designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
Thank you for choosing Feit Electric.
1-866-326-BULB (2852)
FEIT.COM
IMPORTANT SAFETY INSTRUCTIONS
AND INSTALLATION GUIDE
FLAT PANEL UNDER CABINET LIGHT
FITS 18 IN. CABINETS (14 1/2 IN. TOTAL LENGTH)
Table of Contents ................................... 2
Safety Information .................................. 2
FCC Statement ...................................... 2
Warranty .......................................... 2
Pre-Assembly ...................................... 3
Single LED Fixture Hardwire Installation ................4-5
Alternative Plug-In Installation ......................... 6
Operating Instructions ................................ 7
Limited Warranty
Table of Contents
Safety Information Save These Instructions
IMPORTANT SAFEGUARDS:
ALWAYS FOLLOW BASIC SAFETY PRECAUTIONS WHEN USING ELECTRICAL
PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT.
2 WWW.FEIT.COM
Please contact 1-866-326-BULB (2852) for further assistance.
CAUTION: Do not attempt to install while plugged in. This
fixture is for indoor use only. Not for use with plastic cabinets.
Do not install this fixture inside a totally enclosed cabinet.
Do not mount over stoves.
CAUTION: Do not install this product in a wet location.
CAUTION: Do not install this product in an outdoor location.
CAUTION: Do not use chemical solvents or harsh abrasives to
clean the fixture.
FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for
help. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.
Responsible Party: Feit Electric Company
4901 Gregg Road, Pico Rivera, CA 90660, USA
562-463-2852
Unique Identifier: UCL18FP/5CCTCAG3
Supplier’s Declaration of Conformity:
47 CFR § 2.1077 Compliance Information
WARNING: To avoid risk of electrical shock, always make sure
the product is unplugged from the electrical outlet before
assembling, disassembling, relocating, servicing or cleaning it.
This product is warrantied to be free from defects in workmanship and materials for up to 5 years from date of purchase. If the product fails within the warranty period,
please contact Feit Electric at [email protected], visit feit.com/contact-us or call 1-866-326-BULB (2852) for instructions on replacement or refund. REPLACEMENT OR REFUND
IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS
WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of
incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state or province to province.
RF exposure statement
This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of
20cm between the radiator and any part of your body.
This equipment meets the exemption from the routine evaluation limits in section 2.5 of
RSS-102. It should be installed and operated with a minimum distance of 20cm between the
radiator and any part of your body.
Cet équipement est conforme à l'exemption des limites d'évaluation habituelle de la section 2.5
de la norme RSS-102. Il doit être installé et utilisé à une distance minimale de 20 cm entre le
radiateur et toute partie de votre corps.
IC WARNING
This device contains licence-exempt transmitter(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following
two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux
CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
3
Pre-Assembly
TOOLS REQUIRED
NOTE: Hardware not shown to actual size.
HARDWARE INCLUDED
Part Description Quantity
AA 1
1
4
18 in. LED Flat Panel Fixture
BB 18 in. Linking Cable
Mounting Screws
1DD
CC
Fixture Mounting Template
3
1
EE Hardwire Bracket
FF Hardwire Bracket Screw
3GG Wire Nut
1HH Clamp Connector
WWW.FEIT.COM
Please contact 1-866-326-BULB (2852) for further assistance.
PHILLIPS
SCREWDRIVER
PENCIL PLIERS
WRENCH
18 AWG
WIRE STRIPPER
FLAT HEAD
SCREWDRIVER
Item No. Description Volts (V)
Wattage
Per Fixture (W)
Input
Current (mA)
Maximum Linkable
Units at 120V
Maximum Linkable
Units with
In-Wall Dimmer
UCL18FP/5CCTCAG3 18 Inch Flat Panel
Under Cabinet LED Fixture 120 15 180 46 7
Distance
3 ft
5 ft
8 ft
15 ft
54
19
7.6
2.2
7.2 ft
12 ft
19 ft
36 ft
Center Beam (Foot Candles)
Beam Spread: 100˚CD @ CB: 486
Beam Diameter
LIGHTING DISTRIBUTION
AA BB DDCC EE FF GG HH II
2II Mounting Brackets
Single LED Fixture Hardwire Installation
WWW.FEIT.COM
Please contact 1-866-326-BULB (2852) for further assistance.
1
2
Turn the power OFF from the breaker panel before
starting installation.
Turn Off the Power 5
Carefully remove the knock-out with a flathead screwdriver.
Removing the Knock-out
6
Install the Clamp Connector (HH) to the knock-out hole by
inserting it through the hole and securing it with the nut.
The Clamp Connector (HH) should be on the outer side of
the bracket.
Installing the Clamp Connector to the
Knockout Hole
7Cutting and Stripping Wires
Position the Fixture
Find the desired place for the LED light fixture and mark
clearly using the provided mounting bracket template (DD).
4Remove the screw on the hardwire bracket, then slide and
lift the bracket off of the fixture.
Removing the Hardwire Bracket
EE
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
HH
Take out of the black and white 18 AWG wires in the fixture.
Cut and strip the wires to the correct length.
4
DD
3Screw in the Mounting Brackets (II) on the marked locations.
Installing the Mounting Brackets
Marked
locations Mounting screws
II
EE
1
2
x
x
3
9
8
After connecting the wires correctly, place the wires inside the fixture
and reinsert the bracket, sliding it over and screwing it secure.
Wire Power Supply to the Fixture
Replace the Wiring Bracket
Connect the LED Fixtures (AA) using the provided
Linking Cable (BB).
10
Secure the supply wire by firmly screwing the clamp connectors
down on the wire.
Secure Supply Wires with the Clamp Connector
12 Linking LED Fixtures
Feed the supply wire through the Clamp Connector (HH) and
knockout hole and make all connections using the wire nuts
provided. Connect the 120V line (black) wire to the black wire.
Connect the neutral (white) wire to the white wire. Connect the
ground (green) wire to the green wire.
HH
Green
Fig. 1
NOTE: To install 2 or more LED fixtures, repeat the single fixture
installation instructions with two or more units.
BB
AA
Single LED Fixture Hardwire Installation (continued)
x
White
Black
5WWW.FEIT.COM
Please contact 1-866-326-BULB (2852) for further assistance.
11
Lift the light fixture (AA) up to the C-channel brackets (II).
Push firmly until the C-channel brackets (II) snap into the
light fixture (AA).
Installing LED Fixture
x
AA
II
1
3
2
x
x
X
X
EE HH
6WWW.FEIT.COM
Please contact 1-866-326-BULB (2852) for further assistance.
Alternative Plug-In Installation (Electrical Plug not Included)
1Position the Fixtures
Find the desired place for the LED light fixture and mark
clearly using the provided mounting bracket template (DD).
4Connecting the Power Supply
Plug In Electrical Plug to the LED Fixture (AA).
Electrical Plug
AA
NOTE: The electrical plug can be connected to either
side of the LED Fixture (AA).
5
Connect the Electrical Plug to the power outlet on the wall.
Connecting to a Power Outlet
3
2
DD
Screw in the Mounting Brackets (II) on the marked locations.
Installing the Mounting Brackets
Marked
locations Mounting screws
II
Lift the light fixture (AA) up to the C-channel brackets (II).
Push firmly until the C-channel brackets (II) snap into the
light fixture (AA).
Installing LED Fixture
AA
II
Operating Instructions
WWW.FEIT.COM
Please contact 1-866-326-BULB (2852) for further assistance.
Changing the Color Temperature Setting
To select the desired color temperature, cycle through 2700K - 3000K - 3500K - 4000K - 5000K
by pressing the CCT Button. This setting will be fixed each time the ON/OFF switch is turned ON.
Use the ON/OFF and Dim Button for ON/OFF Operation and to Change the Dimming Levels
To select the desired dimming level, cycle through the dimming levels (High, Medium, Low, Dim, Off) by pressing the
Dim Button. This setting will be fixed each time the ON/OFF switch is turned ON.
This LED Fixture has the feature to operate and control multiple units,
even if they are not linked.
To control multiple fixtures, Hold the CCT button for 3 seconds on all the fixtures to be controlled in a group.
To remove the individual fixture from the group, Hold the CCT button on the fixture that you want to control
individually for 3 seconds.
CCT Button
ON/OFF and
DIM Button
7
  • Page 1 1