HeatStar HS4000NG/LP Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire

Ce manuel convient également à

OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read
and follow all instructions. Place instructions in
a safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, light, adjust or operate the heater.
MODEL
MODEL
HS4000 NG/LP
08/11 50401
ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
DIRECT FIRED HEATER
HEATSTAR
BY ENERCO
If the information in this manual is not followed exactly, afire or explosion
may result causing property damage, personal injury or loss of life.
WARNING:
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
Service must be performed by a qualified service agency.
This is a vented portable heater. It uses air (oxygen) from the area in which it is used. Adequate
combustion air and ventilation must be provided. Refer to page 5.
NATURAL GAS/LPG FIRED
2
ENERCO GROUP, INC. |Indirect Fired Portable Heater Operating Instructions and Owner’s Manual
WARNING :
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MA -
TERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE
AWAY FROM THE HEATER AS RECOMMENDED BY TH E
INSTRUCTIONS NEVER USE THE HEATER IN SPAC ES
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNER, DUST PARTICLES OR UN-
KNOWN CHEMICALS.
WARNING :
COMBUSTION BY-PRODUCTS PRODUCED WHEN US -
ING THIS PRODUCT CONTAIN CARB ON MONOXIDE,
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER AND BIRTH D EFECTS (OR OTHER
REPRODUCTIVE HARM).
GENERAL HAZARD WARNING :
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS H EATER, CAN
RESULT IN DEATH, S ERIOUS BODILY INJURY AND
PROPERTY LOSS OR DAMAG E FROM HAZARDS OF FIRE,
EXPLOSION, BURN, ASPHYXIATI ON, CARBON MONOX-
IDE POISONING, AND/ OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS
HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
WARNING :
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING :
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
The State of California requires the following warning:
CONTENTS
WARNINGS .................................................................................. 2-3
SPECIFICATIONS ........................................................................... 4
OPERATION ................................................................................. 5
SAFETY DEVICES .......................................................................... 4
MAINTENANCE ............................................................................ 5
VENTILATION ............................................................................... 5
TROUBLESHOOTING .................................................................... 6
WIRING DIAGRAMS ..................................................................... 7
PARTS LIST .............................................................................11-16
WARNING :
READ THE INSTRUCTIONS GIVEN IN THIS
MANUAL BEFORE USING THE APPLIANCE .
DO NOT USE GASOLINE, NAPHTHA OR VOLATILE
FUELS.
THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE
IS CONNECTED MUST C OMPLY WITH A LL SAFETY
REGULATIONS IN FORCE. A R ESIDUAL CURRENT
CIRCUIT BREAKER MUST B E PROVIDED ON THE MAIN
DISTRIBUTION BOARD.
UNPLUG THE HEATER BEFORE ATTEMPTING ANY
SERVICE OR MAINT ENANCE.
ALWAYS CHECK THE POWER SUPPLY CABLE BEFORE
USE. IT MUST N OT BE BENT, CRUSH ED, OR ANYWAY
DAMAGED.
THE POWER SUPPLY CABLE MUST BE REPLACED ONLY
BY QUA LIFIED PERSONNEL.
ONLY USE AN ORIGINAL H07RN-F POWER CABLE
WITH WAT ERPROOF PLUG.
DO NOT TOUCH THE EXHAUST GAS OUTLET. DANGER
OF BURNS!
IMPORTANT
Before using the heater, read and understand all instructions and
follow them carefully. The manufacturer is not responsible for
damages to goods or persons due to improper use of units.
3Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Indirect Fired Portable Heater
The heater is designed and approved for use as a construction heater in accordance with Standard
ANSI Z83,7 CGA 2.14.
CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT
APPLICATIONS.
Other standards govern the use of fuel gases and heat producing products in specific
applications.Your local authority can advise you about these.
This heater can be washed, provided that:
A. The heater is disconnected from the electrical supply.
B. All access panels are securely closed.
C. Water spray nozzle shall not discharge within 6 feet of the heater.
D. The heater is not reconnected to electrical supply until thoroughly dried.
Improper cleaning of the heater can cause severe personal injury or property damage due to water
and/or cleaning solutions:
A. In electrical components, connections and wires causing electrical shocks or component
failure.
B. On gas control components causing corrosion which can result in gas leaks and fire or
explosion from the leak.The hose assembly must be protected from the traffic, building
materials and contact with hot surfaces both during use andwhile in storage.
Proper gas supply must be provided to the inlet of the appliance.
Refer to rating plate for proper gas supply pressure.
Gas pressure in excess of maximum inlet pressure specified at the appliance inlet can cause fire or
explosions, leading to serious injury, death, building damage or loss of livestock.
Likewise, gas pressure below the minimum inlet pressure specified at the appliance inlet may cause
improper combustion,leading to asphyxation, carbon monoxide poisoning and therefore serious
injury or death to humans and livestock.
Position heater properly before use.
For either indoor or outdoor use adequate ventilation must be provided.
Minimum clearance from combustible materials and propane containers: 10 ft.
Do not operate heater with panels removed.
Not for use with ductwork.
To avoid injury from moving parts, disconnect all electrical power to equipment before opening
doors or removing panels.
RETAIN THIS INSTRUCTION FOR FUTURE REFERENCE. .
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR DEATH.
READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
WARNING :
WARNING :
WARNING :
WARNING :
WARNING :
TECHNICAL SPECIFICATIONS GE/N 250C GE/N 400C
Natural gas
Supply pressure [in WC] min 7" w.c.
max 10" w.c. min 7" w.c.
max 10" w.c.
Selector valve position
Normal
altitude 0 -
2,000 ft above
sea level
(U.S.A. and
Canada)
Heat input [BTU/h] 254.684403.753
Manifold pressure [in WC] 4,33 4,40
Fuel consumption [CFH] 241,52 381,35
Altitude 2,000
- 4,500 ft
above sea
level (Canada
only)
Heat input [BTU/h] 229.216363.378
Manifold pressure [in WC] 4,11 4,18
Fuel consumption [CFH] 217,37 343,21
L.P.G.
Supply pressure [in WC] min 8" w.c.
max 13" w.c. min 8" w.c.
max 13" w.c.
Selector valve position
Normal
altitude 0 -
2,000 ft above
sea level
(U.S.A. and
Canada)
Heat input [BTU/h] 241.413394.134
Manifold pressure [in WC] 4,28 4,50
Fuel consumption [CFH] 88,98 145,12
Altitude 2,000
- 4,500 ft
above sea
level (Canada
only)
Heat input [BTU/h] 217.272354.721
Manifold pressure [in WC] 4,06 4,27
Fuel consumption [CFH] 80,08 130,61
Air flow [cfm] 2.766 4.120
Power supply
Phase 1 1
Voltage [V] 120120
Frequency [Hz] 60 60
Electric consumption [W] 500900
[A] 5,0 8,5
Ring nozzle [in] N. 16 holes x 0,079" N. 16 holes x 0,102"
Gas inlet connection thread 3/4" NPT 3/4" NPT
Air distribution
duct
Max Static pressure [in] 0,60 0,56
Max length [ft] 50 50
Noise level at 1 m [dBA] 77 74
Heater Dimensions, L x W x H [in] 40,6 x 24,6 x 21,7 56,,1 x 29,5 x 25,7
Weight [lb] 101192
Packaging Dimensions, L x W x H [in] 42,3 x 21,9 x 29,45 57,7 x 24,4 x 32,6
Weight [lb] 134225
4Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Indirect Fired Portable Heater
5
ENERCO GROUP, INC. |Indirect Fired Portable Heater Operating Instructions and Owner’s Manual
CONTROL PANEL - TABLEAU DE COMMANDE
Fig. 1
1COMBUSTION CHAMBER
2BURNER
3DIFFUSION RING
4FLAME GUARD SHIELD
5COOLING FAN
6IONIZATION ELECTRODE
7IGNITION ELECTRODE
8CONTROL FLAME ELECTRONIC RESET
9HEATING SWITCH
10 ROOM THERMOSTAT PLUG
11 POWER CONTROL LAMP
12 POWER CORD
13 VENTILATION MODE SWITCH
14 PHASE / NEUTRAL LINE TEST PUSH BUTTON
MANIFOLD ASSEMBLY
GE/N 250 GE/N 400
Fig. 2
aGAS SELECTOR VALVE
bMANIFOLD PRESSURE PORT (MANIFOLD)
cMANIFOLD PRESSURE REGULATOR
dMAIN GAS VALVE
eINLET PRESSURE PORT
fSHUT OFF / FIRING VALVE
8
9
10
13
12
11
4 1 6 3 2 7 5
14
a
b
c
d
e
f
a
b
c
d
e
f
6Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Indirect Fired Portable Heater
DESCRIPTION
The hot air generator is designed for heating medium and large
ventilated premises, for which a fixed or mobile heating system is
required.
Heater is to be run on heating with natural gas or L.P.G. according
to gas supply pressures that must be in conformity with the national
laws.
Gases to be used are indicated in Tab. I together with the supply
pressures, the regulation of the gas valves group (burner pressure)
and gas flow.
Heater is supplied after a complete functional test and it’s therefore
prearranged for one of the working gas indicated in Tab. I: an
adhesive label applied on the gas selector valve (a) indicates the
selected gas.
To change the type of gas, follow the detailed instructions
indicated in sectionCHANGING TYPE OF GAS.
The heater is of the direct combustion type. The air is heated by
the energy developed during combustion and then conveyed to the
environment to be heated together with the combustion products,
thus making available 100% of the thermal power produced. The
environment must be suitably ventilated in order to ensure adequate
air circu-lation.
In the event of serious malfunction various safety devices
(electronic flame control unit, overheating thermostat, air pressure
switch) trigger turning off the heater .
The electronic flame control unit monitors if the flame is irregular or
goes out, the safety thermostat triggers when the temperature in the
combustion chamber exceeds the safety limit value, the air pressure
switch will cut in if the airflow is insufficient.
In each of the said cases the unit stops according to the procedure
described in “OPERATING INSTRUCTIONS”.
In each of the said cases the lamp (8) will light up and the heater
will stop working. The heater can be restarted only by pressing the
reset button (8). Nonetheless, the cause that triggered the safety
device should always be carefullyanalyzed and resolved before
restarting the generator (cfr. “FAULTS, CAUSES AND REMEDIES).
GENERAL ADVICES
Installation, setting and use of the heater must be effected in
accordance with the applicable regulations and laws relating to
machine use.
Check with yourlocal fire safety authority if you have
questions about applications
Here are a few guidelines which shall be followed:
The instructions in this manual are carefully followed;
Minimum clearances from combustible material must be:
1 m (3 feet) from side and rear (air inlet) of heater
0.7 m(2 feet) from ceiling
3 m (10 feet) on air outlet of heater.
Heater shall not be directed toward any propane-gas container
within 6 m (20 feet) and minimum clearances from gas cylinder
must be 3 m (10 feet)
Don’t install the heater in places where there may be a risk of fire
or explosion
All fire prevention regulations must be adhered to.
For air distribution use only original ductworks type M1 Spiraflex
from distributor and respect max length as declared in Tab. I
The room or building which is being heated must be sufficiently
ventilated so that the heater has enough air to function properly;
The air suction and/or supply pipes are not blocked in any way,
there are not sheets or covers resting on the machine or walls
and bulky objects near the heater;
The generator is placed near a power switchboard having
specifications in conformity with those declared;
The unit is placed in a fixed position;
The generator is regularly monitored during operation and
checked before being started up;
Don’t let animals or children near the heater.
Make sure heater is inspected before each use, and at least
annually by a qualified service person.
After use make sure the disconnecting switch is off.
When using any type of heater it is obligatory:
not to exceed the maximum level of heat output of the furnace
(“TECHNICAL SPECIFICATION TABLE”);
to make sure that there is adeguate air circulation and air supply
to the heater and that nothing is obstructing the aspiration and
expulsion of air; movement of air may be obstructed in various
ways including placing covers or other objects on the heater or
positioning the heater too near a wall or other large object. If the
airflow is not adequate, the combustion chamber will overheat
and the overheat thermostat will turn the burner off
(“OBSERVED FAULTS, CAUSES AND REMEDIES”).
INSTALLATION INSTRUCTION
All the operations described in this paragraph must
be performed by professional and skilled personnel
only
The installation shall be in accordance with National Fuel Gas
Code ANSI Z223.1/NFPA 54 and with CAN1-B149.1 Installation
code.
An approved manual gas valve shall be provided by the installer.
In case of installation in greenhouses, mechanical
ventilation shall be interlocked to the heater operation
or permanent openings shall be fixed for ventilation
air.
ELECTRICAL CONNECTIONS
The power line of the generator must feature an
earthlead and a residual current circuit breaker.
The supply cable must be connected to a switchboard
with sectioning switch.
Every heater is supplied along with the safety and control devices
which are indispensable to the correct functioning of the unit being
already electrically connected.
When installed, the appliance must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, and/or the CSA C22.1, Canadian
Electrical Code, if an external electrical source is
utilized.
The following operations must now be carried out:
Plug in the power cord having read the rating plate that specify
electric supply characteristics.
Connect accessories such as the room thermostat or clock to the
unit’s control panel with the thermostat receptacle.
Having completed all these operations check carefully that all
electrical connections correspond to the wiring diagram. When the
heater is first turned on you must check that the fan does not use
more current than the maximum permitted limit.
GAS LINE CONNECTIONS
The connection to the gas feed pipe, whose sizes must correspond
to the kind of system to be made, must be carried out by placing the
gas ramp” as indicated in Fig. 3: the gas pipe, the interception tap
and the anti-vibration joint are not supplied with the heater and they
must be arranged by the person in charge of installation.
WARNING :
WARNING :
WARNING :
WARNING :
WARNING :
7
ENERCO GROUP, INC. |Indirect Fired Portable Heater Operating Instructions and Owner’s Manual
1 Main gas pipe 3 Antivibrating coupling
2 Manual shut-off valve 4 Gas valves group
Fig. 3
In case of connection of heater to natural gas, the installation shall
conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code ANSI Z223.1/NFPA 54 and the Natural Gas
and Propane Installation Code, CSAB149.1.
In case of connection to a propane supply cylinder:
(a) the installation must conform with local codes or, in the
absence of local codes, with the Standard for the Storage and
Handling of Liquified Petroleum Gases, ANSI/NFPA 58 and the
Natural Gas and Propane Installation Code, CSA B149.1.
(b) to determine size and capacity of the cylinder(s) and for any
specific requirements consult your LP gas supplier. In any case
propane tank should not be lower than 100 lb (90 liters)
(c) the cylinder supply system shall be arranged to provide for
vapour withdrawal from the operating cylinder;
(d) the gas shall be turned off at the propane supply cylinder when
the heater is not in use;
(e) when the heater is to be stored indoors, the connection
between the propane supply cylinder and the heater must be
disconnected and the cylinders removed from the heater and
stored in accordance with Standard for the Storage and
Handling of Liquified Petroleum Gases, ANSI/NFPA 58 and
CSA B149.1, Natural Gas andPropane Installation Code.
The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system
by closing its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test pressures equal or
less than 1/2 psi (3.5 kPa).
A minimum 1/8” NPT plugged tapping, accessible for test gauge
connection, must be installed immediately upstream of the gas
supply connection to the appliance.
STARTUP
The heater is supplied after a complete functional test and it’s
therefore prearranged for one of the gas (natural or L.P.G.) indicated
in Tab. I: an adhesive label applied on the manual gas selector valve
(Fig. 4) indicates the working gas (usually it’s natural gas). Should it
necessary to change the kind of gas (from natural gas to L.P.G or
viceversa) follow the detailed instructions indicated in section
CHANGING TYPE OF GAS”.
Only when the heater has been prearranged according to the
proper working gas it will be possible to carry out the following
operations:
Leak away some gas from the feed pipe;
Check that the pipe is gas proof;
Open the gas stopcock and start the hot air generator;
For installation in the U.S.A. at elevation above 2,000 feet (610 m),
the appliance shall be derated 4 per cent for each 1,000 feet (305 m)
of elevation above sea level.
For installation in Canada at elevation above 2,000 feet to 4,500
feet above sea level, the heater is deratedy reducing the input for the
appropriate fuel in accordance with the rating plate manifold
pressure.
THE CONVERSION SHALL BE CARRIED OUT BY A
MANUFACTURER’S AUTHORIZED REPRESENTATIVE,
IN ACCORDANCE WITH THE REQUIREMENTS OF THE
MANUGFACTURER, PROVINCIAL OR TERRITORIAL
AUTHORITIES HAVING JURISDICTION AND IN
ACCORDANCE WITH THE REQUIREMENTS OF THE
CAN/CGA-B149.1 OR CAN/CGAB149.2 INSTALLATION
CODES.
A conversion label shall be applied adiacent to the Rating Label:
THIS APPLIANCE HAS BEEN CONVERTED FOR USE
AT AN ALTITUDE OF ___________ FEET (ABOVE 2000 FEET)
Orifice size: ______________________________________
Manifold pressure: ______________________________________
Input rate: ______________________________________
Date of conversion: ______________________________________
Type of fuel: ______________________________________
Converted by: ______________________________________
For installation in Canada at elevation above 4,500 feetabove sea
level, consult Provincial or Territorial Authorities having jurisdiction.
CHANGING TYPE OF GAS
This operation may be carried out several times during the working
life of the machine and not only at initial start-up. Therefore, first of all
check the adhesive label attached to the manual gas selector valve
(a) in Fig. (2) to establish the original category of the gas and then
consult Tab. I to identify the supply pressure, the working pressure,
the use conditions of manual valve.
To change kind of gas it is necessary (Fig. 2):
to remove the sticker on the manual gas selector valve stating
the gas used at that time,
to remove the screw under the sticker and turn the manual
handle on the correct side according to the condition described in
Tab.I and by following instruction:
Fig. 4
After having moved the handle into the opposite position, put
again the fixing screw and a new sticker on it, stating the gas
which has to be used (a number of different stickers are supplied
with the machine)
Burner pressure shall not be adjusted: the heater is
ready to run on the new gas
Should it necessary to check the burner pressure:
connect a manometer to the pressure port (b) ,
carry out the pressure reading on the manometer and turn the
pressure regulator (c) if necessary to obtain the correct burner
pressure value indicated in Tab. I
OPERATING INSTRUCTIONS
Any time the power cord of the heaters is connected to
a receptacle check the polarity of power supply:
check switch (9) and (13) are on “0”
connect plug to receptacle
push button (14): if it lights up, then reverse polatiry
If the correspondance of phase / neutral polarity is not
correct, the unit may stop in the reset mode.
HEATING MODE
WARNING :
WARNING :
WARNING :
WARNING :
Turning ON
Make sure switch (9) is on “0”;
Power the heater by means of the sectioning switch on the
switchboard;
If the unit is operated manually (without any thermostat or any
other control device) turn the switch (9) to position “1”. The
burner starts up, the combustion chamber heats up and then the
fan starts;
If the unit operates automatically (being connected to any
thermostat or any other control device) turn the switch (9) to
position “1” and set the room thermostat at the desired level: the
heater will now start and stop automatically.
If after these operations, the generator does not work, refer to the
“FAULTS, CAUSES AND REMEDIES paragraph and find the
cause.
Setting Post Ventilation Mode
By the switch (13) on control panel, select the post-ventilation
mode, that is the time the fan goes on blowing air when unit is
switched off:
when switch (134) is on pos. “0” then postventilation lasts for 30
sec.
when switch (13) is on pos. “1” then postventilation is continuous.
Turning OFF
In manual operation turn switch (9) to “0” or turn thermostat control
knob off.
After switching off the machine, a post ventilation function works
according to the previous setting.
Finally, close the gas supply stopcock, close the shut-
off valve (f) and turn off the sectioning switch (Fig. 1-
2).
VENTILATION MODE
To obtain the ventilation function only, make sure switch (9) is on
position 0” and then simply turn the switch (14) to position “1”. To
stop it, turn the switch “4” to position “O”.
Whichever be the reason, the unit try to restart once.
If the cause of malfunction remain, the unit definitevely
stop and lamp (8) will light up
The heater can be restarted only by pressing the reset button (8).
Nonetheless, the cause that triggered the safety device should
always be carefully analyzed and resolved before restarting the
generator (cfr.“FAULTS, CAUSES AND REMEDIES”).
TRANSPORT AND HANDLING
Before moving the unit:
Stop the machine as indicated in the “STOP”
paragraph;
Disengage the power supply by removing the plug
from the power socket;
Fully unscrew the fitting connecting the gas hose
pipe to the heater;
Wait for the heater to cool down.
The hot air generators with wheels must be wheeled.
MAINTENANCE
To regulate operation of the unit, the fans, combustion chamber
and the burner must be at least annually inspected and periodically
cleaned by a qualified service person.
Before performing any maintenance operation:
Stop the machine as indicated in the “STOP”
paragraph;
Disengage the power supply by removing the plug
from the power socket;
Close the gas supply stopcock and shut-off valve (f);
Wait for the heater to cool down.
During cleaning any foreign bodies must be removed from the fan
suction grille.
To access the burner, remove the flame guard panel (4) by
removing the four screws and clean carefully inside the combustion
chamber and the whole burner head: any debris shall be taken away.
Do not direct jets of compressed air towards the air
pressure points near the main fan: the air pressure
switch could be permanently damaged.
Cleaning of the burner shall be regularly performed by qualified
service person. To access the burner, remove the flame guard panel
of combustuion chamber (front side) and clean carefully inside the
combustion chamber and the whole burner head and electrodes.
After cleaning, the flame guard panel of combustion
chamber (4) must be put back in place and secured
with the relative screws before operate the heater.
Operating the heater without the flame guard panel of combustuion
chamber (4) can cause the flame to work with risk to the health of
exposed persons (because of formation of carbon monoxide, CO)
and constituting a danger for the environment.
WARNING :
WARNING :
WARNING :
WARNING :
WARNING :
WARNING :
8
ENERCO GROUP, INC. |Indirect Fired Portable Heater Operating Instructions and Owner’s Manual
TROUBLESHOOTING GUIDE
FAULTS CAUSES REMEDIES
The generator fails to start
No power supply
Check power specifications
Check power connections
Check fuse integrity
Main switch in wrong position Select correct position
Faulty operation of room thermostat
Check thermostat position
Check thermostat operation
Safety device (control unit, safety
thermostat, etc.) not reset after a repair Press button (1) on the control panel
The duct gives too much back pressure
and airpressure switch PA1 blocks the
heater
Reduce back pressure by straightening
the duct or by reducing duct length
The generator stops and the indicator
light (1) comes on
Gas pressure switch trips due to
interruption of gas flow (gas pressure
switch electric contact does not close
during operation)
Make sure the gas supply hose has been
bled
Check gas supply pressure
Micro-switch PAM intervention for fan
malfuction
Make sure the suction and feed grilles
are not blocked
Make sure the fan is turning properly
Check the electric motor and capacitor
and, if these are faulty, replace
The flame sensor is not operating
correctly Remove the flame sensor and clean
The safety thermostat trips due to
overheating of the combustion chamber
(the thermostat electrical contact does not
close during operation)
Makes sure the suction and feed grilles
are not blocked
Make sure the environment is well
ventilated
Make sure the warm air can exit freely
Make sure the flow and pressure of the
gas are not too high
Control unit trips due to irregular
operation of burner Contact After-Sales Service
Faulty gas pressure switch Check the pressure switch and, if
necessary, replace
Faulty micro-switch PAM Check the micro-switch and, if
necessary, replace
Faulty electronic control unit Check the unit and, if necessary, replace
Faulty thermostat Check the thermostat and, if necessary,
replace
Fan noise or vibrations
Foreign bodies on fan blades Remove foreign bodies
Little air circulation Eliminate and obstacles to proper air flow
9
ENERCO GROUP, INC. |Indirect Fired Portable Heater Operating Instructions and Owner’s Manual
10 Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Indirect Fired Portable Heater
WIRING DIAGRAM
AP CONTROL BOX
FU FUSE
EL IONIZATION ELECTRODE
FUA FUSE
LI POVERHEAT THEMOSTAT
PA PRESSURE SWITCH 20 Pa
TA ROOM THERMOSTAT PLUG
IT TRANSFORMER H.T.
CO CAPACITOR
RV HEATING SWITCH
RE MOTOR RELAY
ST CONTROL LAMP
EV GAS TRAIN
MV COOLING MOTOR
RV1 VENTILATION MODE SWITCH
RE1 POST-VENTILATION RELAY
PL 10/07
05 06
07
11
12
75
14
15
16
20
17
19 21
77
76
74
72 73
A
08
18
78
13
50
49
22
B
36
62 63 64
66
65
51
52
53
55
56
58
60
57
61
48
HS4000NG/LP
23
24
25 26 27 26
35
32 34
33
42
71
70
C
62
59
54
38
44
45 37
41
42
39
05 47 46
10
01
03
02
04
09
40
43
26 31
A
50
C
B
11
ENERCO GROUP, INC. |Indirect Fired Portable Heater Operating Instructions and Owner’s Manual
PL 10/07
80
88
90
87
86
82
83
84
81 81
79
89
HS4000NG/LP
85
12
ENERCO GROUP, INC. |Indirect Fired Portable Heater Operating Instructions and Owner’s Manual
NO. HS# BM2 # DESCRIPTION NO. HS# BM2 # DESCRIPTION
01 50345 G06139-9005 Outlet cone 46 50470 C30376 Cable protection ø36mm
02 50346 M10203/1/B Screw TE M6x10 47 50260 E50750 Safety thermostat plastic profile
03 50347 G03114 Flame guard shield 48 50370 G03159-9010 Base
04 50348 G03147 Combustion chamber 49 50077 P50127 Control box cover
05 50349 E50745 Safety thermostat TY95H 50 50371 G00286
Electrical components drawer complete
06 50515 M20413 Clip holder sensing bulb 51 50372 P50132 Electrical components drawer
07 50351 G03150-9010 Upper body 52 50093 E20508 Fuse holder
08 50352 G03152-9010 Cover inspection 53 50092 E10313 Fuse (6x30) 20A
09 50353 G03154-9010 Lower body 54 50373 E11153 Relay finder 65.31.8.110AC
10 50411 C30372 Protection cable ø35 55 50374 E20319 Terminal board
11 50354 G03126 Combustion chamber deflectors 56 50375 E20305 Terminal board
12 50356 GA.0100206 Electrode ionisation probe 57 50329 E10931 Transformer H.T. BRAHMA
13 50545 I40332 Silicone pipe ø5x9 58 50330 E40229
Control box BRAHMA TGRD 81 120V
14 50507 I39106 Anti vibration joint 59 50097 E11125 Relay finder 65.31AC
15 50500 I20326 Connection 3/4"FF 60 50376 G06073 Plate for electrical components
16 50463 G06239-9010 Motor flange 61 50325 E20418 Stop button protection
17 50469 C30374 Drain plug 62 50337 E10110-1-P Switch 0-1
18 50454 E10704-110 Motor 450 W w/ capacitor 80µF 63 50570 E20640 Thermostat plug 3P+T
19 50455 E11249 Capacitor 80µF 64 50011 E20665 Drain plug
20 50166 T10261 Fan ø500 23° 65 50009 E30443
Electrical wire w/plug and cable fastener
21 50050 P30129 Inlet grill 66 50008 E11030 Lamp 120VAC
22 50357 G06330-9005 Valve support plate 70 50081 I20325 Connection 1/8"
23 50506 I39102 Seal 3/4" 71 50079 I31130 Connection straight ø6 1/8"
24 50505 I31205-1 Connection 3/4"MM 72 50511 M10323/1 Screw TCEI M4x20
25 50500 I20326 Connection 3/4"FF 73 50378 GA.0010208 Burner plate
26 50504 I31204 Connection 3/4"MM 74 50379 GA.0100204
Diffusion ring G20/G25-16 holes ø2.6
27 50358 T30330-2 Gas selector valve 75 50380 E20679 Terminal board
31 50359 T30333 Manual gas test firing valve 76 50381 G03129 Burner support
32 50360 E20943 Cable fastener PG9 77 50134 E10215 Ignition electrode
33 50361 E20932 Nut for PG9 78 50417 G02078 H.T. cable connect 90°
34 50334 T30111 Valve solenoid main 79 50382 G03168-9005 Lifting frame
35 50362 G06332-9005 Valve support 80 50383 G03169-9005 Lifting frame
36 50516 M20907 Valve support 81 50384 G03170-9005 Body support
37 50363 G03157-9010 Support for pressure plate 82 50385 G03171-9005 Wheel axle ø25
38 50364 E50443 Pressure switch 330Pa 83 40533 M20111 Washer ø26 x ø44 x 4mm
39 50365 I30414 Oil filter 84 50386 C10556 Wheel ø 260-ø 26mm
40 50337 E50441 Pressure switch 200Pa 85 40534 M20505 Wheel locking pin
41 50366 I40336 Silicone pipe ø4x1.5 86 50387 G03172-9005 Support
42 40501 I40501 Silicone pipe ø4x8 87 50388 G03173-9005 Rignt frame
43 50367 I20669 Connector straight T ø4 88 50389 G03174-9005 Left frame
44 50368 E20952 Cable fasterner PG11 89 50390 G03175-9005 Handle
45 50369 E20955 Nut for PG11 90 40505 C10203 Handle
HS4000DF NG/LP HD Heater Parts List BM2
13
ENERCO GROUP, INC. |Indirect Fired Portable Heater Operating Instructions and Owner’s Manual
OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read
and follow all instructions. Place instructions in
a safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, light, adjust or operate the heater.
MODEL
MODEL
HS
4000IDG
HEATSTAR
BY ENERCO
ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
Mr. Heater is a registered trademark of Enerco Group, Inc.
© 2004, ENERCO GROUP, INC. All rights reserved
WARNING :
USE ONLY MANUFACTUR ER’S REPLACEMENT PARTS. US E OF ANY OTHER PARTS
COULD CAUSE INJURY OR DEATH. R EPLACEMENT PARTS AR E ONLY AVAI LABLE
DIRECT FROM THE FACTORY AND MUST B E INSTALLED BY A QUA LIFIED SERVICE
AGENCY.
PARTS O RDERING INFORMATI ON:
PURC HASING : Accessories may be purchased at any Mr. Heater/HeatStar local dealer
or direct from the factory
FOR INFORM ATI ON REGARDING SER VICE
Please call Toll-Free 800-251-0001 • www.enerco-mrheater.com
Our ofce hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Email to: techservice@enerco-mrheater.com
Please include the model number, date of purchase, and description of problem in all
communication.
LIMITED WARRANT Y
The company warrants this product to be free from imperfections in material or workmanship,
under normal and proper use in accordance with instructions of The Company, for a period
of one year from the date of delivery to the buyer. The Company, at its option, will repair or
replace products returned by the buyer to the factory, transportation prepaid within said one
year period and found by the Company to have imperfections in material or workmanship.
If a part is damaged or missing, call our Technical Support Department at 800-251-0001.
Address any Warranty Claims to the Service Department, Enerco Group, Inc., 4560 W. 160TH
ST., Cleveland, Ohio 44135. Include your name, address and telephone number and include
details concerning the claim. Also, supply us with the purchase date and the name and address
of the dealer from whom you purchased our product.
The foregoing is the full extent of the responsibility of the Company. There are no other
warranties, express or implied. Specically there is no warranty of tness for a particular
purpose and there is no warranty of merchantability. In no event shall the Company be liable for
delay caused by imperfections, for consequential damages, or for any charges of the expense
of any nature incurred without its written consent. The cost of repair or replacement shall be
the exclusive remedy for any breach of warranty. There is no warranty against infringement of
the like and no implied warranty arising from course of dealing or usage of trade. This warranty
will not apply to any product which has been repaired or altered outside of the factory in any
respect which in our judgment aects its condition or operation.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This Warranty gives you specic legal
rights, and you may have other rights which vary from state to state.
Enerco Group, Inc. reserves the right to make changes at any time, without notice or obligation,
in colors, specications, accessories, materials and models.
14
ENERCO GROUP, INC. |Indirect Fired Portable Heater Operating Instructions and Owner’s Manual
ANSI Z83,7 CGA 2.14.
LE
LISEZ SOIGNEUSEMENT LES INSTRUCTIONS :
Lisez et observez toutes les instructions. Conservez
les instructions pour vous y référer ultérieurement.
Interdisez à quiconque n’ayant pas lu les présentes
instructions d’assembler, d’allumer, de régler ou de
faire fonctionner cet appareil de chauage.
GUIDE DUTILISATION ET INSTRUCTIONS DE FONCTIONNEMENT
HEATSTAR
BY ENERCO
HS4000DG
MODÈLE
ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 É.-U. • 800-251-0001
Mr. Heater et HeatStar sont des marques de commerce déposées de Enerco Group, Inc.
© 2003, Enerco Group Inc. Tous droits réservés.
AVERTISSEMENT:
N’UTILISEZ QUE LES PIÈCES DE REMPLACEMENT DU FABRICANT. IL EST POSSIBLE
DE SE PROCURER CES PIÈCES DIRECTEMENT DE L’USINE OU PAR L ENTREMISE DES
DÉTAILLANTS LOCAUX MR. H EATER/HEATSTAR.
INFORMATIONS SUR LA COMMANDE DE PIÈCES :
ACHAT : On peut se procurer les accessoires par l’entremise de tous les détaillants
locaux Mr. Heater/HeatStar ou directement du fabricant
POUR OBTENIR DES INFORMATIONS SUR LE SERVICE
Appelez sans frais au 800-251-0001 • www.enerco-mrheater.com
Nos heures d’ouverture sont de 8 h 30 à 17 h HNE, du lundi au vendredi.
Adressez vos courriels à : techservice@mrheater.com
Veuillez indiquer le numéro du modèle, la date d’achat et la description du problème
dans toutes vos communications avec nous.
GARANTIE LIMITÉE
L’entreprise garantit ce produit contre tout défaut de matériel ou de main-d’œuvre, dans des
conditions dutilisation normale et adéquate, conforment aux instructions de l’entreprise,
pour uneriode d’un an à compter de la date de livraison à l’acheteur. L’entreprise parera ou
remplacera, à sa discrétion, les produits retournés port payé par l’acheteur au fabricant dans la
période d’un an et jugés par l’entreprise comme présentant des défauts de matériel ou de main-
d’œuvre.
Si une pièce est endommagée ou manquante, téléphonez à notre service de soutien technique
au 800-251-0001.
Adressez toute réclamation relative à la garantie à Service Department, Enerco Group, Inc., 4560
W. 160TH ST., Cleveland, Ohio 44135 États-Unis. Indiquez vos nom, adresse et numéro de téléphone
ainsi que les détails de la réclamation. Indiquez-nous également la date d’achat et le nom et l’adresse
du détaillant de qui vous avez acheté le produit.
Ce qui est énoncé ci-dessus constitue la responsabilitotale de l’entreprise. Il n’existe aucune autre
garantie, expresse ou tacite. Plus précisément, il n’y a aucune garantie concernant l’adéquation à une
utilisation particulière ni aucune garantie concernant la qualité marchande. En aucun cas l’entreprise
ne sera tenue responsable des retards causés par des défectuosités, ni des dommages indirects,
ni des dépenses encourues sans son consentement écrit, quelle que soit leur nature. Le coût de la
réparation ou du remplacement sera le seul recours possible en cas de violation de garantie. Il n’y
a aucune garantie contre une transgression de ce genre ni aucune garantie tacite découlant des
usages du commerce ou de la façon habituelle d’échanger. La présente garantie ne s’applique à
aucun produit qui a été réparé ou modié par d’autres que le fabricant si cela inue de quelque
façon que ce soit sur l’état de l’appareil ou son fonctionnement, selon notre jugement.
Certains États ou provinces ne permettent pas d’exclure ou de limiter les dommages indirects ou
subséquents. Par conséquent, les limitations ou exclusions ci-dessus mentionnées ne vous concernent
peut-être pas. La présente garantie vous accorde des droits juridiques précis, mais vous pourriez
avoir d’autres droits qui varient selon la province ou l’État.
Enerco Group Inc. se réserve le droit d’eectuer des modications en tout temps, sans préavis ni
08/08 #50120ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
13 Le fait de Faire marcher des Instructions et le Manuel de PropriétaireENERCO GROUP, INC. |Chauage portatif indirect-tiré
NO. HS# BM2 # DESCRIPTION NO. HS# BM2 # DESCRIPTION
01 50345 G06139-9005 Outlet cone 46 50470 C30376 Cable protection ø36mm
02 50346 M10203/1/B Screw TE M6x10 47 50260 E50750 Safety thermostat plastic profile
03 50347 G03114 Flame guard shield 48 50370 G03159-9010 Base
04 50348 G03147 Combustion chamber 49 50077 P50127 Control box cover
05 50349 E50745 Safety thermostat TY95H 50 50371 G00286
Electrical components drawer complete
06 50515 M20413 Clip holder sensing bulb 51 50372 P50132 Electrical components drawer
07 50351 G03150-9010 Upper body 52 50093 E20508 Fuse holder
08 50352 G03152-9010 Cover inspection 53 50092 E10313 Fuse (6x30) 20A
09 50353 G03154-9010 Lower body 54 50373 E11153 Relay finder 65.31.8.110AC
10 50411 C30372 Protection cable ø35 55 50374 E20319 Terminal board
11 50354 G03126 Combustion chamber deflectors 56 50375 E20305 Terminal board
12 50356 GA.0100206 Electrode ionisation probe 57 50329 E10931 Transformer H.T. BRAHMA
13 50545 I40332 Silicone pipe ø5x9 58 50330 E40229
Control box BRAHMA TGRD 81 120V
14 50507 I39106 Anti vibration joint 59 50097 E11125 Relay finder 65.31AC
15 50500 I20326 Connection 3/4"FF 60 50376 G06073 Plate for electrical components
16 50463 G06239-9010 Motor flange 61 50325 E20418 Stop button protection
17 50469 C30374 Drain plug 62 50337 E10110-1-P Switch 0-1
18 50454 E10704-110 Motor 450 W w/ capacitor 80µF 63 50570 E20640 Thermostat plug 3P+T
19 50455 E11249 Capacitor 80µF 64 50011 E20665 Drain plug
20 50166 T10261 Fan ø500 23° 65 50009 E30443
Electrical wire w/plug and cable fastener
21 50050 P30129 Inlet grill 66 50008 E11030 Lamp 120VAC
22 50357 G06330-9005 Valve support plate 70 50081 I20325 Connection 1/8"
23 50506 I39102 Seal 3/4" 71 50079 I31130 Connection straight ø6 1/8"
24 50505 I31205-1 Connection 3/4"MM 72 50511 M10323/1 Screw TCEI M4x20
25 50500 I20326 Connection 3/4"FF 73 50378 GA.0010208 Burner plate
26 50504 I31204 Connection 3/4"MM 74 50379 GA.0100204
Diffusion ring G20/G25-16 holes ø2.6
27 50358 T30330-2 Gas selector valve 75 50380 E20679 Terminal board
31 50359 T30333 Manual gas test firing valve 76 50381 G03129 Burner support
32 50360 E20943 Cable fastener PG9 77 50134 E10215 Ignition electrode
33 50361 E20932 Nut for PG9 78 50417 G02078 H.T. cable connect 90°
34 50334 T30111 Valve solenoid main 79 50382 G03168-9005 Lifting frame
35 50362 G06332-9005 Valve support 80 50383 G03169-9005 Lifting frame
36 50516 M20907 Valve support 81 50384 G03170-9005 Body support
37 50363 G03157-9010 Support for pressure plate 82 50385 G03171-9005 Wheel axle ø25
38 50364 E50443 Pressure switch 330Pa 83 40533 M20111 Washer ø26 x ø44 x 4mm
39 50365 I30414 Oil filter 84 50386 C10556 Wheel ø 260-ø 26mm
40 50337 E50441 Pressure switch 200Pa 85 40534 M20505 Wheel locking pin
41 50366 I40336 Silicone pipe ø4x1.5 86 50387 G03172-9005 Support
42 40501 I40501 Silicone pipe ø4x8 87 50388 G03173-9005 Rignt frame
43 50367 I20669 Connector straight T ø4 88 50389 G03174-9005 Left frame
44 50368 E20952 Cable fasterner PG11 89 50390 G03175-9005 Handle
45 50369 E20955 Nut for PG11 90 40505 C10203 Handle
HS4000DF NG/LP HD Heater Parts List BM2
12
PL 10/07
80
88
90
87
86
82
83
84
81 81
79
89
HS4000NG/LP
85
11
PL 10/07
05 06
07
11
12
75
14
15
16
20
17
19 21
77
76
74
72 73
A
08
18
78
13
50
49
22
B
36
62 63 64
66
65
51
52
53
55
56
58
60
57
61
48
HS4000NG/LP
23
24
25 26 27 26
35
32 34
33
42
71
70
C
62
59
54
38
44
45 37
41
42
39
05 47 46
10
01
03
02
04
09
40
43
26 31
A
50
C
B
10 Le fait de Faire marcher des Instructions et le Manuel de PropriétaireENERCO GROUP, INC. |Chauage portatif indirect-tiré
SCHÉMA ÉLECTRIQUE
AP COFFRET DE SECURITE
FU FUSIBLE
EL ÉLECTRODE D'IONISATION
FUA FUSIBLE
LI THERMOSTAT PUISSANCE CHAUFFAGE
PA PRESSOSTAT 20 Pa
RE2 RELAIS RETARD DÉMARRAGE (opt.)
TA PRISE THERMOSTAT D'AMBIANCE
IT TRANSFORMATEUR H.T.
CO CONDENSATEUR
RV INTERRUPTEUR DE CHAUFFAGE
RE RELAIS MOTEUR
ST VOYANT DE CONTRÔLE
EV CONDUIT GAZ
MV REFROIDISSEMENT MOTEUR
RV1 INTERRUPTEUR MODE VENTILATION
RE1 RELAIS POST-VENTILATION
RRÉSISTANCE ANTI-HUMIDITÉ (opt)
9Le fait de Faire marcher des Instructions et le Manuel de PropriétaireENERCO GROUP, INC. |Chauage portatif indirect-tiré
GUIDE DE DÉPANNAGE
ANOMALIES
DE FONCTIONNEMENT CAUSES SOLUTIONS
Le générateur ne démarre pas
Manque d'alimentation électrique
Vérifier les caractéristiques de
l'alimentation électrique
Vérifier les branchements élec
Vérifier que le fusible est intact
Mauvaise position de l'interrupteur
général Placer l'interrupteur sur la position
correcte
Fonctionnement irrégulier du thermostat
d'ambiance
Vérifier la position du thermostat
Vérifier le fonctionnement du thermostat
Dispositif de sécurité (unide contrôle,
thermostat de sécurité etc.) non
réinitialisés aps une réparation
Enfoncer le poussoir (1) sur le tableau de
commande
Le conduit fournit trop de pression de
retour et l'interrupteur de pression d'air
PA1 bloque le générateur
Réduire la pression de retour en
redressant le conduit ou en en réduisant la
longueur
Le générateur s'arrête et le témoin (1)
s'allume
(le contact électrique de l'interrupteur de
pression du gaz ne se ferme pas pendant
le fonctionnement)
Vérifier que le tuyau d'alimentation en
gaz a été purgé
Contrôler la pression d'alimentation du
gaz
Intervention du pressostat d'air suite au
dysfonctionnement du ventilateur
Vérifier que les grilles de l’aspiration et
de l’évacuation ne sont pas obstruées
Vérifier que le ventilateur tourne
librement
Vérifier le moteur électrique et le
condensateur et les remplacer s'ils sont
fectueux
Le capteur de flamme ne fonctionne pas
correctement Retirer le capteur de flamme et le
nettoyer
(le contact électrique du thermostat ne se
ferme pas pendant le fonctionnement)
Vérifier que les grilles de l'aspiration et
de l'évacuation ne sont pas obstruées
Vérifier que le local est correctement
Contrôler que l'air chaud peut sortir
librement
Contrôler que le débit ou la pression des
gaz n'est pas excessif
Intervention du système de surveillance
suite au fonctionnement irrégulier du
brûleur
Contacter l'Assistance technique
Défaillance pressostat gaz Contrôler le pressostat et, si cessaire,
le remplacer.
Défaillance du microinterrupteur PAM Contrôler le microinterrupteur et, si
cessaire, le remplacer.
Système électronique de surveillance
fectueux Contrôler le système et le remplacer si
cessaire
Thermostat défectueux Contrôler le thermostat et le remplacer si
cessaire
Le ventilateur fait du bruit ou émet des
vibrations
Des corps étrangers se trouvent sur les
pales du ventilateurRetirer les corps étrangers
La circulation d'air est insuffisante Supprimer tous les obstacles pouvant
gêner le passage de l'air
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28