Modern Forms WS-12721 Glacier Mode d'emploi

Taper
Mode d'emploi
1
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
INSTALLATION INSTRUCTION
Glacier
WS-12721
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local
regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or
switch ”OFF” the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts
that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en
position d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel quil est indiqué dans ces instructions. Ne remplacez pas les pièces, nen
laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler
l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression
à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta
lación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional
y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali
mentación principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la
instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la
base sólo.
HARDWARE
A1 B1 C1 J1 H1 I1
Wire
Connector
Qty: 3
7EAC112201
P3
Junction Box
Screw
Qty: 2 + 1 Extra
7MPF0415C2
#8-32x9/16” SS
Set Screw
Qty: 1 Extra
7MPF0415C2
5/32-32x3/8”
Nickel Plating
Allen Wrench
Screw
Qty: 1 pc
7MPE305001
Gasket
Qty: 2 pcs + 1 extra
7MPH1004F01NI
Nickel Plating
Screw
Qty: 2 pcs + 1 extra
7MPF041207
SS
2
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
INSTALLATION INSTRUCTION
Glacier
WS-12721
100%-10% DIMMING
COMPATIBLE WITH THE FOLLOWING ELECTRONIC
LOW VOLTAGE (ELV) DIMMERS
Brand Model
LUTRON SELV-300P
LUTRON DVELV-300P
LEVITON MLE03-1
PREPARATION
1. Shut o the power at the circuit breaker and remove
existing xture, including the mounting hardware.
2. Carefully unpack your new xture and lay out the
parts on a clear area. Be careful not to lose any
small parts necessary for installation.
3. Remove the mounting screws (C1) from the xture.
4. Connect the xture wires to supplier wires as shown in
Fig. 2, making sure that all wire connectors (A1) secured.
Fixture and junction box ground wires should be connected
to mounting plate using green screw provided. After wires
are connected, tuck them carefully inside the junction box.
5. Secure the mounting plate (D1) to the junction box
(F1) using the junction box screws (B1). The side
of the mounting plate marked “GND” must face out.
6. Place the glass (E1) into the xture top. Secure it
using Allen screw (I1) and Allen wrench provided.
7. Place the xture back plate (G1) over the mounting
plate (D1) and secure with mounting screws (C1).
FIG.1
E1
I1
G1
C1
B1 D1
A1
F1
Fixture
Screw
Fixture Mounting
Screw
Mounting
Plate
Wire
Connector
Junction
Box
Glass
Allen Screw
Fixture Wires
Brown
Fixture Wires
Blue
Fixture Wires
Yellow Green
House Wires
Hot
House Wires
Neutral
House Wires
Ground Wire
Fig. 2 Wiring
  • Page 1 1
  • Page 2 2

Modern Forms WS-12721 Glacier Mode d'emploi

Taper
Mode d'emploi