SICK AR60 Laser Alignment Aid Mode d'emploi

Catégorie
Niveaux laser
Taper
Mode d'emploi
de
en
fr
O P E R A T I N G I N S T R U C T I O NS
AR60
Laser Alignment Aid
Operating Instructions
AR60
2 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8007406/174W/2020-06-16
Subject to change without notice
This document is protected by the law of copyright, whereby all rights
established therein remain with the company SICK AG. Reproduction
of this document or parts of this document is only permissible within
the limits of the legal determination of Copyright Law. Alteration or
abridgement of the document is not permitted without the explicit
written approval of the company SICK AG.
This document is an original document.
Betriebsanleitung
AR60
8007406/174W/2020-06-16 © SICK AG • Industrial Safety Systems • Deutschland • Alle Rechte vorbehalten 3
Irrtümer und Änderungen vorbehalten
Inhalt
de
Inhalt
1 Allgemeines ....................................................................................4
1.1 Die Laser-Ausrichthilfe AR60 auf einen Blick .......................4
1.2 Einsatzbereiche .....................................................................5
2 Justiervorgang ................................................................................6
3 Ausrichtung über Umlenkspiegel ..................................................7
4 Technische Daten ...........................................................................8
5 Bestelldaten ....................................................................................9
5.1 Laser-Ausrichthilfe AR60 .......................................................9
6 Anhang ......................................................................................... 10
6.1 Tabellenverzeichnis ............................................................ 10
6.2 Abbildungsverzeichnis ........................................................ 10
6.3 Konformität mit EU-Richtlinien ........................................... 10
Kapitel 1 Betriebsanleitung
AR60
4 © SICK AG • Industrial Safety Systems • Deutschland • Alle Rechte vorbehalten 8007406/174W/2020-06-16
Irrtümer und Änderungen vorbehalten
Allgemeines
de
1 Allgemeines
Die Laser-Ausrichthilfe AR60 ist ein Gerät, um verschiedene optische
Sensoren von SICK auszurichten, wie z. B. Lichtschranken und Licht-
vorhänge.
1.1 Die Laser-Ausrichthilfe AR60 auf einen Blick
Kleines Gehäuse.
Netzunabhängig durch Batterie-Stromversorgung
1)
.
Anschraubfläche für verschiedene Adapter.
Handlicher Laserpointer.
Mit der Laser-Ausrichthilfe AR60 können die optischen Sensoren
(Sender/Empfänger) bei der Montage auf einfache Weise und zeit-
sparend ausgerichtet werden schon bevor die Sensoren mit Span-
nung versorgt werden.
Sehr vorteilhaft ist die Laser-Ausrichthilfe AR60, wenn mittels
Umlenkspiegel das Lichtbündel umgelenkt wird. Die Ausrichtung
(Einjustierung) von Sender/Empfänger und Umlenkspiegel lässt sich
somit von einer Person in kürzester Zeit durchführen.
1)
Batterien sind nach den gesetzlichen Vorschriften getrennt zu entsorgen.
Abb. 1: Aufbau der Laser-
Ausrichthilfe AR60
Anschraubfläche
Micro-
batterien
2 x 1,5 V
Ein-/Ausschalter
Lichtaustritt
ca. 6 mm
Zum Wechseln der Batterien
Deckel abnehmen
Nivellierlibelle
Betriebsanleitung Kapitel 1
AR60
8007406/174W/2020-06-16 © SICK AG • Industrial Safety Systems • Deutschland • Alle Rechte vorbehalten 5
Irrtümer und Änderungen vorbehalten
Allgemeines
de
Blicken Sie nie direkt in den Laserstrahl!
Die Laserstrahlung ist bei zufälliger, kurzzeitiger Einwirkung (< 0,25 s)
für das Auge ungefährlich. Eine Gefahr für das Auge besteht nur
dann, wenn die eigene Abwendreaktion gegenüber blendendem Licht
unterdrückt wird. Falls Laserstrahlung ins Auge trifft, schließen Sie
die Augen bewusst und wenden sich sofort ab.
Richten Sie niemals den Laserstrahl in die Augen von Personen.
Warnhinweis!
Vorsicht wenn andere als die hier angegebenen Bedienungs- oder
Justiereinrichtungen benutzt oder andere Verfahrensweisen ausge-
führt werden, kann dies zu gefährlicher Strahlungsexposition führen.
1.2 Einsatzbereiche
Die Laser-Ausrichthilfe AR60 ist auch für die effiziente Störungsbe-
seitigung sowie für Service- und Wartungsarbeiten von Vorteil.
Über verschiedene Adapter können die unterschiedlichen Geräte
ausgerichtet werden.
Bei Lichtschranken oder Lichtvorhängen mit Schutzfeldhöhen
750 mm empfiehlt sich die Ausrichtung mit zwei Laser-
Ausrichthilfen AR60, angebracht an den Geräteenden.
Hinweis

ACHTUNG
Kapitel 2 Betriebsanleitung
AR60
6 © SICK AG • Industrial Safety Systems • Deutschland • Alle Rechte vorbehalten 8007406/174W/2020-06-16
Irrtümer und Änderungen vorbehalten
Justiervorgang
de
2 Justiervorgang
Den dem Sensor entsprechenden Adapter an AR60 anschrauben.
AR60 vor Sender montieren (fest aufklipsen oder anschrauben).
AR60 einschalten.
Auf dem Empfänger einen weißen Karton bzw. Karton mit
Scotchlite (Reflexionsband) anbringen (Lichtbündel ist so besser zu
erkennen).
Sender so ausrichten, dass das Lichtbündel auf die Mitte der
Empfängeroptik trifft.
Sender in dieser Position befestigen.
AR60 vor Empfänger montieren und Empfänger so auf den Sender
ausrichten, dass das Lichtbündel auf die Mitte der Senderoptik
trifft.
Empfänger in dieser Position befestigen.
AR60 ausschalten.
AR60 abmontieren.
Sensoren einschalten.
Bei der Laser-Ausrichthilfe AR60 kann ein deutlich schwächerer zwei-
ter Lichtfleck auftreten. Bei Abständen über 3 m ist dieser nicht mehr
sichtbar. In Abständen unter 3 m darf dieser nicht zur Ausrichtung
verwendet werden.
Betriebsanleitung Kapitel 3
AR60
8007406/174W/2020-06-16 © SICK AG • Industrial Safety Systems • Deutschland • Alle Rechte vorbehalten 7
Irrtümer und Änderungen vorbehalten
Ausrichtung über
Umlenkspiegel
de
3 Ausrichtung über Umlenkspiegel
Adapter an AR60 montieren.
AR60 vor Sender montieren.
AR60 einschalten.
Auf dem Umlenkspiegel einen weißen Karton bzw. Karton mit
Scotchlite (Reflexionsband) anbringen (Lichtbündel ist so besser zu
sehen).
Sender so ausrichten, dass Lichtbündel in die Mitte des
Umlenkspiegels trifft.
Sender in dieser Position befestigen.
Karton vor (erstem) Umlenkspiegel entfernen.
Karton vor zweitem Umlenkspiegel anbringen.
Ersten Umlenkspiegel so ausrichten, dass das Lichtbündel auf die
Mitte des zweiten Umlenkspiegels trifft.
Ersten Umlenkspiegel in dieser Position befestigen.
Karton vor zweitem Umlenkspiegel entfernen.
Zweiten Umlenkspiegel so ausrichten, dass das Lichtbündel auf die
Mitte der Empfängeroptik trifft, evtl. einen weißen Karton bzw.
Karton mit Scotchlite (Reflexionsband) anbringen.
Zweiten Umlenkspiegel in dieser Position festschrauben.
Karton wieder vor zweitem Umlenkspiegel anbringen.
AR60 vor den Empfänger montieren.
Empfänger so ausrichten, dass das Lichtbündel auf die Mitte des
zweiten Umlenkspiegels trifft.
Empfänger in dieser Position festschrauben.
AR60 ausschalten.
AR60 abmontieren.
Sender und Empfänger einschalten.
Abb. 2: Ausrichtung einer
WSU/WEU26/3 über
Umlenkspiegel
AR60
AR60
Sender
Empfänger
Umlenkspiegel
Umlenkspiegel
Kapitel 4 Betriebsanleitung
AR60
8 © SICK AG • Industrial Safety Systems • Deutschland • Alle Rechte vorbehalten 8007406/174W/2020-06-16
Irrtümer und Änderungen vorbehalten
Technische Daten
de
4 Technische Daten
Minimal
Typisch
Maximal
Spannungsversorgung
3 V
Batterie
2 Stück
1,5 V
Micro/AAA
Betriebsdauer Batterien
ca. 10 h
Schutzart
IP 20
Gehäuse
Aluminium
Reichweite (je nach
Reflexionsmaterial und
Umgebungshelligkeit)
60 m
Lichtquelle
Halbleiter-
Laser
Optische Leistung
1 mW
Wellenlänge (Rotlicht)
630 nm
680 nm
Lichtbündeldurchmesser
ca. 6 mm
Lagertemperatur
0 °C
55 °C
Betriebsumgebungs-
temperatur
0 °C
40 °C
Laserklasse
Laserklasse 2
Entspricht IEC/EN 60825-1:2007,
IEC/EN 60825-1:2014, 21 CFR
1040.10 und 1040.11 mit Ausnahme
der Abweichungen gemäß Laser Notice
No. 50, 24. Juni 2007
Tab. 1: Technische Daten
Laser-Ausrichthilfe AR60
Betriebsanleitung Kapitel 5
AR60
8007406/174W/2020-06-16 © SICK AG • Industrial Safety Systems • Deutschland • Alle Rechte vorbehalten 9
Irrtümer und Änderungen vorbehalten
Bestelldaten
de
5 Bestelldaten
5.1 Laser-Ausrichthilfe AR60
Artikel
Artikelnummer
Laser-Ausrichthilfe AR60
1015741
Tab. 2: Artikelnummer
Laser-Ausrichthilfe AR60
Kapitel 6 Betriebsanleitung
AR60
10 © SICK AG • Industrial Safety Systems • Deutschland • Alle Rechte vorbehalten 8007406/174W/2020-06-16
Irrtümer und Änderungen vorbehalten
Anhang
de
6 Anhang
6.1 Tabellenverzeichnis
Tab. 1: Technische Daten Laser-Ausrichthilfe AR60........................... 8
Tab. 2: Artikelnummer Laser-Ausrichthilfe AR60 ................................ 9
6.2 Abbildungsverzeichnis
Abb. 1: Aufbau der Laser-Ausrichthilfe AR60 ...................................... 4
Abb. 2: Ausrichtung einer WSU/WEU26/3 über Umlenkspiegel......... 7
6.3 Konformität mit EU-Richtlinien
EU-Konformitätserklärung (Auszug)
Der Unterzeichner, der den nachstehenden Hersteller vertritt, erklärt
hiermit, dass das Produkt in Übereinstimmung mit den Bestimmun-
gen der nachstehenden EU-Richtlinie(n) (einschließlich aller zutreffen-
den Änderungen) ist, und dass die entsprechenden Normen und/oder
technischen Spezifikationen zugrunde gelegt sind.
Vollständige EU-Konformitätserklärung zum Download: www.sick.com
Operating Instructions
AR60
8007406/174W/2020-06-16 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 11
Subject to change without notice
en
List of Contents
1 General ......................................................................................... 12
1.1 The AR60 at a Glance ......................................................... 12
1.2 Applications ........................................................................ 13
2 Alignment Procedure .................................................................. 14
3 Alignment via Deflector Mirrors ................................................. 15
4 Technical Specifications ............................................................. 16
5 Ordering Information ................................................................... 17
5.1 AR60 Laser Alignment Aid .................................................. 17
6 Appendix....................................................................................... 18
6.1 List of Tables ....................................................................... 18
6.2 List of Illustrations .............................................................. 18
6.3 Compliance with EU directives ........................................... 18
Chapter 1 Operating Instructions
AR60
12 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8007406/174W/2020-06-16
Subject to change without notice
General
en
1 General
The AR60 laser alignment aid is a device for aligning various SICK
optical sensors, such as for example photoelectric switches and light
curtains.
1.1 The AR60 at a Glance
Compact housing.
Battery power supply no need for mains power
1)
.
Surface to which various adapters can be screwed.
Easy-to-handle laser pointer.
Using the AR60 laser alignment aid, optical sensors (sender/receiver)
may be quickly and easily aligned during installation, even before
power is supplied to the sensors.
The AR60 laser alignment aid is of great advantage when the beam
array is deflected by means of deflector mirrors. The alignment
(adjustment) of sender/receiver and deflector mirrors can thus be
carried out very rapidly by one person.
1)
Batteries are to be disposed of separately in accordance with statutory regulations.
Fig. 1: Construction of the
AR60 laser alignment aid
Connection screw
Micro-
battery
2 x 1.5 V
On/Off switch
Light emission
approx. 6 mm
Remove cover to
change battery
Spirit level
Operating Instructions Chapter 1
AR60
8007406/174W/2020-06-16 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 13
Subject to change without notice
General
en
Never look directly into the laser beam!
The laser beam is not dangerous for the eye in case of accidental,
brief exposure (< 0.25 s). There is only a hazard for the eye if the
normal blinking reaction to bright light is suppressed. If the laser
beam is incident on your eye, consciously close your eyes and turn
away immediately.
Never point the laser beam at peoples eyes.
Warning!
Caution use of controls, adjustments or performance of procedures
other than those herein specified may result in hazardous radiation
exposure.
1.2 Applications
The AR60 laser alignment aid is also useful for efficient fault
elimination and in servicing and maintenance work.
Various adapters are used in aligning the different devices.
For photoelectric switches or light curtains with protective field
heights 750 mm, it is recommended that two AR60 laser alignment
aids, fitted to the ends of the device, are used for alignment.
Note

WARNING
Chapter 2 Operating Instructions
AR60
14 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8007406/174W/2020-06-16
Subject to change without notice
Alignment Procedure
en
2 Alignment Procedure
Screw the adapter matching the sensor onto the AR60.
Mount the AR60 in front of the sender (clip it on firmly or screw it
on).
Switch on the AR60.
Fit a white card or a card covered with Scotchlite (reflective tape)
on the receivers (this makes the beam array easier to detect).
Align the sender so that the beam array strikes the centre of the
receiver optic.
Fix sender in this position.
Mount AR60 in front of the receiver and align sender on receiver,
so that the beam array strikes the centre of the sender.
Fix receiver in this position.
Switch off AR60.
Detach AR60.
Switch on sensors.
When using the AR60 laser alignment aid an additional light spot of
lower intensity might appear. When using for distances above 3 m
this spot becomes invisible. When used for distances below 3 m this
spot should not be used for alignment purposes.
Operating Instructions Chapter 3
AR60
8007406/174W/2020-06-16 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 15
Subject to change without notice
Alignment via Deflector
Mirrors
en
3 Alignment via Deflector Mirrors
Fit adapter to AR60.
Mount AR60 in front of sender.
Switch on AR60.
Affix a piece of white card or a card covered with Scotchlite (reflec-
tive tape) to the deflector mirror (to make beam array more visible).
Align sender so that beam array strikes the centre of the deflector
mirror.
Fix sender in this position.
Remove card from (first) deflector mirror.
Affix card in front of second deflector mirror.
Align first deflector mirror so that the beam array strikes the centre
of the second deflector mirror.
Fix first deflector mirror in this position.
Remove card from second deflector mirror.
Align second deflector mirror so that the beam array strikes the
centre of the receiver optics, if necessary affix white card or a card
covered with Scotchlite (reflective tape).
Fix second deflector mirror in this position.
Re-affix card to second deflector mirror.
Mount AR60 in front of the receiver.
Align receiver so that the beam array strikes the centre of the
second deflector mirror.
Fix receiver in this position.
Switch off AR60.
Dismount AR60.
Switch sender and receiver on.
Fig. 2: Alignment of a
WSU/WEU26/3 via
deflector mirrors
AR60
AR60
Sender
Receiver
Deflector mirror
Deflector mirror
Chapter 4 Operating Instructions
AR60
16 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8007406/174W/2020-06-16
Subject to change without notice
Technical Specifications
en
4 Technical Specifications
Minimum
Typical
Maximum
Voltage supply
3 V
Batteries
2 x 1.5 V
Micro/AAA
Battery life
Approx.
10 h
Enclosure rating
IP 20
Housing
Aluminium
Scanning range
(depending on reflective
material and ambient
light)
60 m
Light source
Semi-
conductor
laser
Optical Power
1 mW
Wavelength (red light)
630 nm
680 nm
Beam array diameter
Approx.
6 mm
Storage temperature
0 °C
55 °C
Ambient operating
temperature
0 °C
40 °C
Laser Class
Laser Class 2
Complies with IEC/EN 60825-1:2007,
IEC/EN 60825-1:2014, 21 CFR
1040.10 and 1040.11 except for
deviations pursuant to Laser Notice No.
50, dated June 24, 2007
Tab. 1: Technical
specifications AR60 laser
alignment aid
Operating Instructions Chapter 5
AR60
8007406/174W/2020-06-16 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 17
Subject to change without notice
Ordering Information
en
5 Ordering Information
5.1 AR60 Laser Alignment Aid
Article
Part Number
AR60 laser alignment aid
1015741
Tab. 2: Ordering
information AR60 laser
alignment aid
Chapter 6 Operating Instructions
AR60
18 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8007406/174W/2020-06-16
Subject to change without notice
Appendix
en
6 Appendix
6.1 List of Tables
Tab. 1: Technical specifications AR60 laser alignment aid ............... 16
Tab. 2: Ordering information AR60 laser alignment aid .................... 17
6.2 List of Illustrations
Fig. 1: Construction of the AR60 laser alignment aid ...................... 12
Fig. 2: Alignment of a WSU/WEU26/3 via deflector mirrors ............ 15
6.3 Compliance with EU directives
EU declaration of conformity (excerpt)
The undersigned, representing the following manufacturer herewith
declares that the product is in conformity with the provisions of the
following EU directive(s) (including all applicable amendments), and
that the respective standards and/or technical specifications are
taken as the basis.
Complete EU declaration of conformity for download: www.sick.com
Notice d’instructions
AR60
8007406/174W/2020-06-16 © SICK AG • Industrial Safety Systems • Allemagne • Tous droits réservés 19
Sujet à modification sans préavis
Sommaire
fr
Sommaire
1 Généralités ................................................................................... 20
1.1 Caractéristiques.................................................................. 20
1.2 Domaines d’utilisation ........................................................ 21
2 Procédure de réglage .................................................................. 22
3 Alignement avec miroirs de renvoi ............................................. 23
4 Caractéristiques techniques ...................................................... 24
5 Références ................................................................................... 25
5.1 Outil d’alignement laser AR60 ........................................... 25
6 Annexe .......................................................................................... 26
6.1 Répertoire des tableaux ..................................................... 26
6.2 Répertoire des figures ........................................................ 26
6.3 Conformité aux directives UE ............................................. 26
Chapitre 1 Notice d’instructions
AR60
20 © SICK AG • Industrial Safety Systems • Allemagne • Tous droits réservés 8007406/174W/2020-06-16
Sujet à modification sans préavis
Généralités
fr
1 Généralités
L’outil d’alignement laser AR60 est une cellule laser destinée à
faciliter l’alignement des barrières et barrages immatériels de SICK.
1.1 Caractéristiques
Boîtier de petite taille.
Alimentation par pile
1)
.
Possibilité de visser différents adaptateurs.
Pointeur laser facile à manipuler.
L’outil d’alignement laser AR60 assure un alignement aisé et rapide
des cellules optiques (émetteur/récepteur) avant même leur mise
sous tension.
Ce système s’avère très utile lorsque l’installation comporte des
miroirs de renvoi : une personne seule pourra effectuer l’alignement
(le réglage) de l’émetteur/récepteur et du miroir de renvoi, en un
temps réduit.
Ne jamais regarder directement dans le faisceau laser !
Pour une exposition accidentelle de courte durée (< 0,25 s), le
faisceau laser n’est pas dangereux pour l’œil. Il reste toutefois un
risque pour l’œil dans un cas : si le réflexe de détournement du
1)
Selon les prescriptions légales, les batteries doivent être éliminées dans des filières spécialisées.
Fig. 1 : Plan de l’outil
d’alignement laser AR60
Remarque
Vis de serrage
Piles
2 x 1,5 V
Interrupteur Marche/Arrêt
Sortie de lumière
env. 6 mm
Pour changer les piles,
démonter le couvercle
Niveau à bulle
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

SICK AR60 Laser Alignment Aid Mode d'emploi

Catégorie
Niveaux laser
Taper
Mode d'emploi