Astria Fireplaces POLARIS Instruction Sheet

Catégorie
Cheminées
Taper
Instruction Sheet

Ce manuel convient également à

1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
IN CANADA: THE CONVERSION SHALL BE CAR-
RIED OUT IN ACCORDANCE WITH THE REQUIRE-
MENTS OF THE PROVINCIAL AUTHORITIES
HAVING JURISDICTION AND IN ACCORDANCE
WITH THE REQUIREMENTS OF THE CAN/CSA
B149.1 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EFFECTUÉE
CONFORMÉMENT AUX RECOMMANDA-
TIONS DES AUTORITÉS PROVINCIALES
AYANT JURIDICTION ET CONFORMÉMENT
AUX EXIGENCES DU CODE D'INSTALLATION
CAN/CSA B149.1.
Gas conversion kits are available to adapt your
appliance from the use of one type of gas to the
use of another. These kits contain all the neces-
sary components needed to complete the task
including labeling that must be affixed to ensure
safe operation.
Kit part numbers are listed here and the following
steps detail the conversion procedure.
CAUTION: THE GAS SUPPLY SHALL BE SHUT
OFF PRIOR TO DISCONNECTING THE ELECTRI-
CAL POWER, BEFORE PROCEEDING WITH THE
CONVERSION.
Step 1. Turn off the gas supply to the appliance
and disconnect the electrical power.
Step 2. Carefully remove the logs. Exercise care
so as not to break the logs. Remove any lava
rock within the burner pan.
Step 3. Remove the burner tube with attached
venturi tube. Refer to Figure 1 for the location
of the control valve and regulator, main orifice
and pilot.
Access
Cover
Control Valve
And Regulator
Pilot Orifice Burner Tube
Main
Orifice
Figure 1
Gas Conversion Kits
Models Conversion
Type
Catalog No.
(Model)
Polaris36/42
VRE4336/42
E36/42ODG
Propane (LP)
to
Natural Gas
H4915
(GCK-DB166N)
Polaris36/42
VRE4336/42
E36/42ODG
Natural Gas
to
Propane (LP)
H4916
(GCK-DB089P)
INSTALLATION INSTRUCTIONS FOR GAS CONVERSION KITS FOR USE WITH OUTDOOR GAS FIREPLACES
[MODELS POLARIS36/42, VRE4336/42 AND E36/42ODG SERIES ELECTRONIC OUTDOOR FIREPLACES]
DEXEN ELECTRONIC
GAS CONVERSION KITS
P/N 750222M
Rev. C, 03/2020
HEARTH PRODUCTS
KITS AND ACCESSORIES
WARNING
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire,
explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life.
The qualified service agency performing this installation
is responsible for the proper installation of this kit and
assumes responsibility for this conversion. The instal-
lation is not proper and complete until the operation of
the converted appliance is checked as specified in the
manufacturers instructions supplied with the kit. The
qualified service agency performing this installation
assumes responsibility for this conversion.
AVERTISSEMENT
Cet équipement de conversion sera installé par
une agence qualifiée de service conformément aux
instructions du fabricant et toutes exigences et codes
applicables de l'autorisés avoir la juridiction. Si
l'information dans cette instruction n'est pas suivie
exactement, un feu, explosion ou production de
protoxyde de carbone peut résulter le dommages
causer de propriété, perte ou blessure personnelle de
vie. L'agence qualifiée de service est esponsable de
l'installation propre de cet équipment. L'installation
n'est pas propre et compléte jusqu'à l'opération de
l'appareil converti est chéque suivant les critères
établis dans les instructions de propriétaire provi-
sionnées avec l'équipement.
2
Figure 6
Step 8. Turn on gas supply and test for gas
leaks, using a soapy water solution.
Step 7. Attach appropriate conversion kit label
(Figure 6 ) to the rating plate on the appliance.
Printed in U.S.A. © 2006 Innovative Hearth Products
P/N 750222M REV. C 03/2020
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 3
Figure 2
Figure 4
Note: If the ignitor is damaged, a replacement kit
is available, order Catalog Number 87L54.
Step 6. Reassemble the remaining components
by reversing the procedures outlined in the
preceding steps.
Pilot Stage
Terminal Pressure-Tap
(Inlet) Pilot Gas
Outlet
Supply Gas
Inlet
Pressure-Tap
(Manifold)
Burner Stage
Terminal
Ground
(TP)
PILOT
OUT
VENT
LO
TH
TP
TH
TP
HI
IN
IN
Gas Outlet
To Burner
Regulator
Mounting Screw
Figure 5
Electronic Appliances
Step 4. Dexen Electronic Valves - See Figure
2 and the instructions provided with the kit.
Remove and discard the two pressure regula-
tor mounting screws. Remove the pressure
regulator and diaphragm. Discard all removed
components. Ensure the provided diaphragm
is installed properly onto the replacement
pressure regulator and install the new pressure
regulator using the new screws supplied with
the kit. Tighten screws.
See Figure 3 and replace the pilot orifice as
follows: Remove pilot hood assembly to
access the pilot orifice. Remove and replace
the orifice with the one provided with the kit.
Exercise extreme care to prevent damage to
or breakage of the ignitor assembly.
Step 5. (Refer to Figure 5 )
A. Remove the orifice from the manifold and
replace it with the one provided in the kit. See the
following table for orifice sizes for natural and pro-
pane models. Figure 4 illustrates the orifice.
B. Retrieve the burner and slide the venturi
tube over the orifice. Set the shutter adjusting
opening as shown in Figure 5.
Remove Tube
Regulator
Orifice
Remove Clip
Shutter
Opening
RENRUBNIAM
GNITTESGNINEPORETTUHSYROTCAF
sledoM saGlarutaN
)mm(sehcni
saGenaporP
)mm(sehcni
llA
sledoM 61/1)85.1
(2
/
1)
7.21(
.oNledoM
ezisecifirO
larutaNenaporP
sledoMllA 82#
5041.0
74#
5870.0
Use pipe joint compound or Teflon tape on all
pipe fittings before installing (ensure propane
resistant compounds are used in propane ap-
plications, do not use pipe joint compounds
on flare fittings).
THIS APPLIANCE HAS BEEN CONVERTED TO:
NATURAL GAS
INPUT BTU/HR 50,000
MANIFOLD PRESSURE 3.5"
ORIFICE SIZE (0.130)
THIS APPLIANCE HAS BEEN CONVERTED TO:
PROPANE/LPG
INPUT BTU/HR 50,000
MANIFOLD PRESSURE 10"
ORIFICE SIZE (0.080)
ELECTRONIC PILOT
Pilot
Hood
Sensor
Ignitor
PROPANE NATURAL
Innovative Hearth Products (IHP) reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
  • Page 1 1
  • Page 2 2

Astria Fireplaces POLARIS Instruction Sheet

Catégorie
Cheminées
Taper
Instruction Sheet
Ce manuel convient également à

dans d''autres langues