Dell PowerVault MD1220 Guide de démarrage rapide

Taper
Guide de démarrage rapide
Dell™ PowerVault™
MD1220 Storage Enclosures
Getting Started
With Your System
Začínáme se systémem
Guide de mise en route
Handbuch zum Einstieg
Τα πρώτα βήματα με το σύστημά σας
Rozpoczęcie pracy z komputerem
Приступая к работе с системой
Introducción al sistema
Sistem Başlangıç Kılavuzu
Dell™ PowerVault™
MD1220 Storage Enclosures
Getting Started
With Your System
Regulatory Model Series E04J
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better
use of your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of
data if instructions are not followed.
WARNING: A WARNING indicates a potential for property damage,
personal injury, or death.
____________________
Information in this document is subject to change without notice.
© 2009 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, OpenManage, PowerEdge, and PowerVault are
trademarks of Dell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Regulatory Model Series E04J
April 2010 P/N F571M Rev. A01
Getting Started With Your System 3
Installation and Configuration
WARNING: Before performing the following procedure, review the safety
instructions that came with the system.
Unpacking the System
Unpack your system and identify each item.
Installing the Rails and System in a Rack
CAUTION: If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma)
specified by the manufacturer. For more information, see "Technical
Specifications" on page 7.
Assemble the rails and install the system in the rack following the safety
instructions and the rack installation instructions provided with your system.
4 Getting Started With Your System
Connecting the Power Cable(s)
Ensure that the power switch is in the OFF position before connecting the
power cable(s). Connect the system’s power cable(s) to the system.
Securing the Power Cable(s)
Bend the system power cable(s) as shown in the illustration and secure the
cable(s) firmly to the bracket using the provided strap.
Plug the other end of the power cable(s) into a grounded electrical outlet or a
separate power source such as an uninterrupted power supply (UPS) or a
power distribution unit (PDU).
Getting Started With Your System 5
Turning On the System
Press the power switch to the ON position. The power indicators should light.
NOTE: Ensure that the storage enclosure is connected to the server and the mode
switch is set to split or unified mode before turning on the system.
Installing the Optional Bezel
Install the bezel (optional).
6 Getting Started With Your System
Other Information You May Need
WARNING: See the safety and regulatory information that shipped with your
system. Warranty information may be included within this document or as a
separate document.
The rack documentation included with your rack solution describes how
to install your system into a rack.
•The
Hardware Owner’s Manual
provides information about system
features and describes how to troubleshoot the system and install or
replace system components. This document is available online at
support.dell.com/manuals
.
Any media that ships with your system that provides documentation
and tools for configuring and managing your system, including those
pertaining to the operating system, system management software,
system updates, and system components that you purchased
with your system.
NOTE: Always check for updates on support.dell.com/manuals and read the
updates first because they often supersede information in other documents.
NOM Information (Mexico Only)
The following information is provided on the device described in
this document in compliance with the requirements of the
official Mexican standards (NOM):
Importer:
Model number: E04J
Supply voltage: 100–240 V CA
Frequency: 50/60 Hz
Current consumption: 8.6 A
Getting Started With Your System 7
Technical Specifications
Drives
SAS hard drives Up to 24 2.5-inch SAS hot-swappable hard
drives (3.0 Gbps and 6.0 Gbps)
Enclosure Management Modules (EMMs)
EMMs One or two hot-swappable modules with
temperature sensors and an audio alarm
Connectivity
Configurations Support for either of the following
configurations:
Unified mode for direct connectivity to
24 hard drives per enclosure.
Up to four daisy-chained storage
enclosures for a total of 96 hard drives
per controller port and 192 hard drives
per controller.
Maximum configuration of
two dual port controllers per server for
a total of 384 drives.
Redundant path connectivity provides
redundant data paths to each hard drive.
Redundant path configuration supports
up to four daisy-chained storage
enclosures for a total of 96 hard drives
per controller and up to 192 hard drives
per server.
Split mode with dual EMMs provides a
direct connectivity to drives 0 through 11
and a separate direct connectivity to
drives 12 to 23. Split mode configuration
does not support daisy-chaining or
redundant data paths.
8 Getting Started With Your System
Redundant Array of Independent Disks (RAID)
Controller Host-based RAID support using
PowerEdge™ RAID controller H800.
Management RAID management using
Dell OpenManage™ Server
Administrator 6.2 or later.
Back-Plane Board
Connectors
24 SAS hard-drive connectors
Two power supply/cooling fan
module connectors
Two sets of EMM connectors
One control panel connector for front LEDs
and enclosure mode switch
Sensors Two temperature sensors
Back-Panel Connectors (per EMM)
SAS connectors
One SAS IN connector for connection
to the host
One SAS OUT connector for expansion to
an additional enclosure
NOTE: SAS connectors are SFF-8086/SFF-8088
compliant.
Serial connector One 6-pin UART mini-DIN connector
NOTE: For engineering use only.
LED Indicators
Front panel
One two-color LED indicator for
system status
Two single-color LED indicators for
power and split mode
Hard-drive carrier
One single-color activity LED
One two-color LED status indicator
per drive
Getting Started With Your System 9
EMM Three two-color LED status indicators,
one each for the two EMM SAS ports and
one for the EMM status
Power supply/cooling fan Three LED status indicators for power supply
status, power supply/cooling fan fault status,
and AC status
Switch
System identification button Located on the front control panel.
This button is used to locate a system
within a rack.
Mode switch Located on the front control panel.
This switch is used to switch the system
between unified and split mode operation.
Power Supplies
AC power supply (per power supply)
Wattage
600 W
Voltage
100–240 VAC (8.6 A–4.3 A)
Heat dissipation
188 W
Maximum inrush current
Under typical line conditions and over the
entire system ambient operating range,
the inrush current may reach 55 A per
power supply for 10 ms or less.
Available Hard Drive Power (Per Slot)
Supported hard drive power
consumption (continuous)
Up to 1.2 A at +5 V
Up to 0.5 A at +12 V
EMM Power (Per Slot)
Maximum power consumed by EMM 14 W at +12 V
Maximum available power 100 W at +12 V
Maximum available power 1 W at +5 V (standby)
LED Indicators (continued)
10 Getting Started With Your System
Physical
Height 8.68 cm (3.41 inches)
Width 44.63 cm (17.57 inches)
Depth 54.90 cm (21.61 inches)
Weight (maximum configuration) 23.31 kg (51.4 lb)
Weight (empty) 8.61 kg (19 lb)
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet,
the maximum operating temperature
is derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with
a maximum temperature gradation
of 20°C per hour
Relative humidity
Operating
20% to 80% (noncondensing) with
a maximum humidity gradation
of 10% per hour
Storage
5% to 95% (noncondensing)
Maximum vibration
Operating
0.25 G at 3–200 Hz for 15 min
Storage
0.5 G at 3–200 Hz for 15 min
Getting Started With Your System 11
Maximum shock
Operating
One shock pulse in the positive z axis
(one pulse on each side of the system) of
31 G for 2.6 ms in the operational orientation
Storage
Six consecutively executed shock pulses
in the positive and negative x, y, and z axes
(one pulse on each side of the system) of
71 G for up to 2 ms
Altitude
Operating
–16 to 3048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2950 feet,
the maximum operating temperature is
derated 1ºF/550 ft.
Storage
–16 to 10,600 m (–50 to 35,000 ft)
Airborne Contaminant Level
Class
G2 or lower as defined by ISA-S71.04-1985
Environmental (continued)
12 Getting Started With Your System
Datová úložiště
Dell™
PowerVault™ MD1220
Začínáme se systémem
Regulační model série E04J
Poznámky a upozornění
POZNÁMKA:
POZNÁMKA označuje důležité informace, které pomáhají lepšímu využití
počítače.
UPOZORNĚNÍ: UPOZORNĚNÍ označuje nebezpečí poškození hardwaru nebo
ztráty dat v případě nedodržení pokynů.
VAROVÁ: VAROVÁNÍ upozorňuje na potenciální nebezpečí poškození majetku,
úrazu nebo smrti.
____________________
Informace obsažené v tomto dokumentu podléhají změnám bez předchozího upozornění.
© 2009 Dell Inc. Všechna práva vyhrazena.
Jakákoli reprodukce těchto materiálů bez písemného povolení společnosti Dell Inc. je přísně zakázána.
Ochranné známky použité v tomto textu: Dell, logo DELL a OpenManage, PowerEdge a PowerVault
jsou ochranné známky společnosti Dell Inc.
V tomto dokumentu mohou být použity další ochranné známky a obchodní názvy s odkazem na
společnosti vlastnící tyto známky a názvy nebo na jejich produkty. Společnost Dell Inc. nemá
vlastnické zájmy vůči ochranným známkám a obchodním názvům jiným než svým vlastním.
Regulační model série E04J
Duben 2010 Č. dílu F571M Rev. A01
Začínáme se systémem
15
Instalace a konfigurace
VAROVÁNÍ: Před provedením následujícího postupu si prostudujte bezpečnostní
pokyny dodané se systémem.
Rozbalení systému
Rozbalte systém a identifikujte jeho jednotlivé součásti.
Instalace kolejniček a systému do stojanu
UPOZORNĚNÍ: Pokud provedete instalaci do uzavřeného stojanu nebo do stojanu
pro více jednotek, bude teplota v okolí stojanu při práci vyšší, než teplota v
místnosti. Z tohoto důvodu byste měli dbát na to, aby bylo vybavení instalováno jen
do prostředí kompatibilního s maximální teplotou okolí (Tma)
stanovenou výrobcem. Více informací najdete v části „Technické údaje“
na straně 19.
Sestavte kolejničky a nainstalujte systém do stojanu podle bezpečnostních
pokynů a pokynů k instalaci do stojanu dodaných se systémem.
16
Začínáme se systémem
Připojení napájecích kabelů
Předtím, než připojíte napájecí kabely, se prosím ujistěte, že se vypínač nachází
v poloze VYPNUTÝ. Připojte napájecí kabel(y) k systému.
Zajištění napájecích kabelů
Ohněte napájecí kabely systému tak, jak je znázorněno na obrázku, a připevněte
je dodanou páskou k držáku.
Poté zasuňte druhý konec napájecích kabelů do uzemněné elektrické zásuvky
nebo je připojte k samostatnému zdroji napájení, například ke zdroji
nepřerušitelného napájení (UPS) nebo jednotce rozvaděče (PDU).
Začínáme se systémem
17
Zapnutí systému
Přepněte vypínač do polohy ZAPNUTO. Indikátory napájení by se měly
rozsvítit.
POZNÁMKA:
Ujistěte se, že je datové úložiště připojeno k serveru a přepínač režimů je
před zapnutím systému nastaven na režim „rozdělený“ nebo „sjednocený“.
Instalace volitelného čelního krytu
Nainstalujte čelní kryt (volitelný).
18
Začínáme se systémem
Další užitečné informace
VAROVÁ: Prostudujte si informace o bezpečnosti a předpisech, které byly
dodány se systémem. Informace o záruce jsou součástí tohoto dokumentu nebo
jsou přiloženy samostatně.
Pokyny k instalaci do stojanu dodané se stojanovým řešením popisují
instalaci systému do stojanu.
Příručka majitele hardwaru
obsahuje informace o funkcích systému a
popisuje řešení problémů se systémem a instalaci nebo výměnu
komponent. Tento dokument je k dispozici online na adrese
support.dell.com/manuals
.
Média dodaná se systémem obsahují dokumentaci a nástroje pro
konfiguraci a správu systému. Mohou být dodána například média týkající
se operačního systému, softwaru pro správu systému, aktualizací systému a
komponenty zakoupené se systémem.
POZNÁMKA:
Vždy nejprve zkontrolujte a pročtěte aktualizace uvedené na adrese
support.dell.com/manuals
, protože tyto aktualizace často nahrazují informace v
ostatních dokumentech.
Informace NOM (pouze Mexiko)
K zařízení popsanému v tomto dokumentu se vztahují v souladu s požadavky
oficiální mexické normy NOM následující informace:
Dovozce:
Číslo modelu: E04J
Napájecí napětí: 100–240 V stř.
Frekvence: 50/60 Hz
Spotřeba proudu: 8,6 A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122

Dell PowerVault MD1220 Guide de démarrage rapide

Taper
Guide de démarrage rapide