DRYER SAFETY ............................................................... 2
iNSTALLATiON REQUIREMENTS ................................... 4
Tools and Parts ................................................................... 4
LOCATION REQUIREMENTS .................................................... 5
ELECTRIC DRYER POWER HOOKUP-CANADA ONLY .......... 6
Electrical Requirements .................................................... 6
GAS DRYER POWER HOOKUP ................................................ 7
Electrical Requirements .................................................... 7
Gas Supply Requirements ................................................. 7
iNSTALL LEVELING LEGS ......................................................... 8
VENTING ..................................................................................... 9
Venting Requirements ........................................................ 9
PLAN VENT SYSTEM ............................................................... 10
iNSTALL VENT SYSTEM ......................................................... 12
MAKE GAS CONNECTION ...................................................... 12
CONNECT iNLET HOSES ........................................................ 12
CONNECT VENT ...................................................................... 14
LEVEL DRYER .......................................................................... 14
COMPLETE iNSTALLATiON CHECKLIST .............................. 15
REVERSE DOOR SWING ......................................................... 15
TROUBLESHOOTING .............................................................. 17
Table des matibres
SF:CURIT¢: DE LA S¢:CHEUSE ........................................ 18
EXIGENCES D'INSTALLATION ....................................... 20
Outillage et pi_ces ............................................................. 20
EXIGENCES D'EMPLACEMENT ............................................... 21
RACCORDEMENT DE LA SECHEUSE
leLECTRIQUE - CANADA SEULEMENT .................................. 22
Sp6cifications _lectriques ................................................. 22
RACCORDEMENT D'UNE S#CHEUSE A GAZ ........................ 23
Specifications 61ectriques ................................................. 23
Specifications de I'alimentation en gaz ........................... 23
iNSTALLATiON DES PIEDS DE NIVELLEMENT ...................... 25
L' EVACUATION .......................................................................... 25
Exigences concernant I'evacuation ................................. 25
PLANIFICATION DU SYSTEME D'EVACUATION ..................... 26
iNSTALLATiON DU SYST_:ME DqeVACUATION ....................... 28
RACCORDEMENT AU GAZ ....................................................... 29
RACCORDEMENT DES TUYAUX D'ALIMENTATION .............. 29
RACCORDEMENT DU CONDUIT D'ISVACUATION ................. 31
RLeGLAGE DE L'APLOMB DE LA SIsCHEUSE ......................... 31
LISTE DE VleRIFICATION
POUR iNSTALLATiON TERMINleE ............................................ 32
iNVERSiON DU SENS D'OUVERTURE DE LA PORTE ............ 32
DLePANNAGE .............................................................................. 34
iNSTALLATiON NOTES
Date of purchase:
Date of installation:
Installer:
Model number:
Serial number:
NOTES CONCERNANT L'INSTALLATION
Date d'achat :
Date d'installation :
Installateur :
Num6ro de module :
Num_ro de s6rie :
Para obtener acceso al "lnstrucciones de instalaci6n" en espaSol, o para obtener informaci6n
adicional acerca de su producto, visite: www.whirlpool.com
Tenga Nsto su nOmero de modelo completo. Puede encontrar el nOmero de modelo
y de serie dentro de la cavidad superior de la puerta.
W10392126A
W10392127A-SP
DRYER S_ETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING - ...i.. ofFi,o..
- Clothes dryer installation must be performed by a qualified installer.
- install the clothes dryer according to the manufacturer's instructions and local codes,
= Do not install a clothes dryer with fle×ible plastic venting materials or flexible metal
(foil type) duct. if fle×ible metal duct is installed, it must be of a specific type identified
by the appliance manufacturer as suitable for use with clothes dryers, Fle×ible venting
materials are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct clothes dryer airflow and increase the risk of fire.
= To reduce the risk of severe injury or death, follow all installation instructions.
= Save these instructions.
When discarding or storing your old clothes dryer, remove the door.
2
WARNING: For your safety, the information in this manual must be followed to minimize 1
the risk of fire or explosion, or to prevent property damage, personal injury, or death. 1
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- WHAT TO DO iF YOU SMELL GAS:
o Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
®Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
= if you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the "What to do if you smell gas" instructions.
iMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSi Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
in the State of Massachusetts, the following installation instructions apply:
[] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] if using a ball valve, it shall be a T-handle type.
[] A flexible gas connector, when used, must not exceed 3 feet.
TOOLS AND PARTS
IN$ LATION REQUIREMENTS
Tools needed for gas installations:
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed for all installations:
Flat-blade screwdriver
Level
Utility knife
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Vent clamps
Caulking gun and compound
(for installing new exhaust vent)
8" (203 mm) or 10"
(254 mm) pipe wrench
8" (203 mm) or 10"
(254 mm) adjustable wrench
(for gas connections)
Pipe-joint compound
resistant to LP gas
Parts supplied {all models):
Leveling legs (4)
Parts supplied {steam models):
"Y" connector
2' (0.6 m) inlet hose
Tin snips (new vent
installations)
1/4"( 6 mm) nut driver
(recommended)
Tape measure Pliers
5' (1.5 m) Inlet Hose
Rubber washer
Remove parts package from dwer drum. Check that all parts
are included.
Parts needed: (Not supplied with dwer)
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the "Assistance
or Service" section in your "Use and Care Guide".
4
Optional Equipment: (Not supplied with dryer)
Refer to your "Use and Care Guide" for information about
accessories available for your dryer.
LOCATION REQUIREMENWS
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer,
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
A location allowing for proper exhaust installation.
See "Venting Requirements".
[]
[]
[]
[]
[]
[]
A separate 15 or 20-amp circuit needed for gas dryers and
30-amp circuit needed for electric dryers.
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements".
Floor must support dryer weight of 200 Ibs. (90.7 kg).
Also consider weight of companion appliance.
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1", clothes may not tumble
properly and automatic sensor cycles may not operate
correctly.
For garage installation, place dryer at least 18" (460 mm)
above floor.
[]
Steam models only: Cold water faucets located within 4 ft.
(1.2 m) of the water fill valves, and water pressure of 20-100
psi (137.9-689.6 kPa). You may use the water supply for your
washer using the "Y" connector provided.
Do not operate your dryer at temperatures below 45° F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic sensor cycle, this can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check codes requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
INSTALLATION CLEARANCES
The location must be large enough to allow the dryer door
to open fully.
DRYER DIMENSIONS
Side view with open door dimensions:
-,,=====221/4"-------__ 30"------_
(50 ram) (783ra!!/-
44"
mm)
1//2H
(13ram)
Back view:
63/4"
(171 rnrn}
f
O ©
(368 ram)__ 11"
T
441/2"
(1371 _----_mm)l 1
_- (25turn)
(279 ram)
Bottom view:
31/4" _1
(83_rn)
4141/2"-_ "=-141/2"-_
(368 ram) (368 ram)
NOTE: Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See "Venting
Requirements".
Spacingfor recessedareaor closet installation
All dimensions show recommended spacing allowed, with tested
spacing of 0" (0 mm) clearance on sides and rear.
[] Additional spacing should be considered for ease of
installation and servicing.
[] Additional clearances might be required for wall, door, and
floor moldings.
[] Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
[]
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
[] Companion appliance spacing should also be considered.
ELECTRIC DR R
FOWER HOOKUFo ONLY
ELECTRICAL REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
(76
n
(76
(127 ram)
(25turn}
Mobile home =Additional installation requirements:
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile home
construction and Safety, Title 24, HUD Part 280) or Standard
CAN/CSA-Z240 MH.
Mobile home installations require:
All dryers:
[] Metal exhaust system hardware, available for purchase
from your dealer. For further information, see "Assistance
or Service" section in your "Use and Care Guide".
[]
Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a
nearby window) should be at least twice as large as
dryer exhaust opening.
For gas dryers mobile home installations:
[] Mobile Home Installation Hold-down Kit Part Number
W10432680 is available to order. For further information,
see "Assistance or Service" section in your "Use and
Care Guide".
it is your responsibility:
[] Tocontact a qualified electrical installer.
[]
[]
[]
To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual
branch circuit.
This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft. (1.52 m) long. Be sure wall
receptacle is within reach of dryer's final location.
4-wire receptacle (14-30R)
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 9831317.
For further information, please reference service numbers located
in "Assistance or Service" section of your "Use and Care Guide".
6
GROUNDING iNSTRUCTiONS
m For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
GAS DR R POWER HOOKUP
ELECTRICAL REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
[]
120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate
circuit serving only this dryer be provided.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
GAS SUPPLY REQUIREMENTS
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut=off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 ram) water
column,
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
[]
Your dryer must have the correct burner for the type of gas
in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does
not agree with the type of gas available, contact your dealer
or call the phone numbers referenced in the "Assistance or
Service" section of your "Use and Care Guide".
LP Gas Conversion:
IMPORTANT: Conversion must be made by a qualified
technician.
No attempt shall be made to convert the dryer from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
GAS SUPPLY LiNE
[] Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer.
E
B
A. 3/8" flexible gas connector
B.3/8" pipe to flare adapter fitting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E.Gasshutoff valve.
[] 1/2" IPS pipe is recommended.
[] 3/8" approved aluminum or copper tubing is acceptable for
lengths under 20 ft. (6.1 m) if local codes and gas supplier
permit.
[] If you are using Natural gas, do not use copper tubing.
[] Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter fitting.
[] If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length of
the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON<e_tape.
[] Must include shut-off valve
In the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) ft. (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1. The location should be easy to
reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) ft. (1.8 m) of
the dryer. The location should be easy to reach for opening
and closing.
GAS SUPPLY CONNECTION REQUIREMENTS
[] Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting
between the flexible gas connector and the dryer gas pipe,
as needed to avoid kinking.
[] Use only pipe-joint compound. Do not use TEFLON _'*_ttape.
[] This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
BURNER iNPUT REQUIREMENTS
Elevations above 10,000 ft. (3,048 m):
[] When installed above 10,000 ft. (3,048 m) a 4% reduction
of the burner Btu rating shown on the model/serial number
plate is required for each 1,000 ft. (305 m) increase in
elevation.
Gas supply pressure testing
[] The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
DRYER GAS PiPE
[] The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
_ 4 1/2""
(115 ram)
1"
(25 ram)
A. 1/2" NPT gas supply line
B. 3/8" NPT dryer pipe
NOTE: If the dryer is mounted on a pedestal, the gas pipe height
must be an additional 10" (254 mm) or 15.5" (394 mm) from the
floor, depending on the pedestal model. For a garage installation,
the gas pipe height must be an additional 18" (460 mm) from
the floor.
1®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
8
INSTALL LE¥ LING LEGS
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
rl, Prepare dryer for leveling legs
,%
,%
",%
"%
To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire dryer. Firmly grasp
dryer body (not console panel) and gently lay dryer down on
cardboard.
IMPORTANT: If laying dryer on its back, use the cardboard
corner posts the dryer was packed with to avoid damaging
the back of the dryer. Lay the dryer on its side if you do not
have the cardboard corner posts the dryer was packed with.
Screw in leveling legs
N
Examine leveling legs. Screw legs into leg holes by hand,
use a wrench if necessary, to finish turning legs until they
begin to touch the base.
Now stand the dryer on its legs. Slide the dryer until it is
close to its final location. Leave enough room for electrical
connection and to connect the exhaust vent.
¥ NTING
VENTING REQUIREMENTS
Fire Hazard
Use a heavy metal vent,
Do not use a plastic vent.
Do not use a metal foil vent,
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
4m'
(102 ram)
t
4" (102 mm) heavy metal exhaust vent
[] Only a 4" (102 mm) heaw metal exhaust vent and clamps
may be used.
[] Do not use plastic or metal foil vent.
Rigid metal vent:
[] Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only ifaccessible to clean)
[]
[]
Must be fully extended and supported in final dryer location.
Remove excess to avoid sagging and kinking that may
result in reduced airflow and poor performance.
[] Do not install in enclosed walls, ceilings, or floors.
[] The total length should not exceed 7 3/4ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from
entire length of the system and make sure exhaust hood
is not plugged with lint. Replace plastic or metal foil vents
with rigid metal or flexible metal vents. Review Vent System
Chart and if necessary, modify existing vent system to
achieve best drying performance.
Exhausthoods:
[] Must be at least 12" (305 ram) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes,
or snow).
Recommended Styles:
Louvered Hood
Acceptable Style:
Box Hood
Angled Hood
Elbows:
[] 45° elbows provide better airflow than 90° elbows.
Recommended Styles:
............ Be
Clamps:
[]
[]
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
improper venting can cause moisture and lint to collect
indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
PLAN SYSTEM
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
A ...........................
c
H
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
R Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Optional exhaust installations:
Fire Hazard
Use a heavy metal vent,
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
[]
[]
Exhaust Cover Kit (to cover unused exhaust holes):
Part Number W10186596 - all models
Bottom Exhaust Kit- Part Number 8212503
Vent products can be purchased from your dealer. For more
information, see "Assistance or Service" section in your "Use
and Care Guide".
10
If you prefer, dryer may be converted to exhaust through
the bottom. You must contact your local dealer to have dryer
converted.
i
A B
A.Standard rearoffset exhaust installation
B. Bottom exhaust installation
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
Determine vent path:
[] Select route that will provide straightest and most direct
path outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
[] Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent System Chart. Exhaust systems longer than those
specified will:
[] Shorten life of dryer.
[] Reduce performance, resulting in longer drying times
and increased energy usage.
The Vent System Charts provide venting requirements that
will help achieve best drying performance.
A B
A. Over-the-top installation
(also available with one offset elbow)
B. Periscope installation
Whirlpool Vent System Chart
Number of Type Box/Iouvered Angled
90 °elbows of vent hoods hoods
0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m)
NOTE: The following kits for close clearance alternate
installations are available for purchase. Contact your local dealer.
[] Over-the-Top Installation:
Part Number 4396028
[]
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
Part Number 4396011 - 18" (460 mm) to 29" (737 mm)
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)
mismatch
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
______j
Moblie Home Exhaust installation
2
3
Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
Rigid metal 44 ft. (13.4m) 38 ft. (11.6m)
Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m)
4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m)
Maytag Vent System Chart
Number of Type Box/Iouvered Angled
90 °elbows of vent hoods hoods
0 Rigid metal 100 ft. (30.5 m) 94 ft. (28.7 m)
1 Rigid metal 90 ft. (27.4 m) 84 ft. (25.6 m)
2 Rigid metal 80 ft. (24.4 m) 74 ft. (22.6 m)
3 Rigid metal 71 ft. (21.6 m) 65 ft. (19.8 m)
4 Rigid metal 63 ft. (19.2 m) 57 ft. (17.4 m)
NOTE: Bottom exhaust installations have a 90 ° turn inside the
dryer. To determine maximum exhaust length, add one 90 ° turn
to the charts.
11
INSTALL ¥_NT SYSTEM
1, install exhaust hood
_] _ 12" rain.
_305 ram)
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
2. Connect vent to exhaust hood
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location
using straightest path possible. Avoid 90°turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
2. Plan pipe fitting connection
I
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
3. Open shut-off valve
CIosed_
Open valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
r__ GAS CONNECTION
Flared L__ _ Non-flared
malefitting __ _
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings. If flexible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON ®t tape.
CONNECT INLET HOSES
For non-steam models, skip to "Connect Vent" on page 14.
The dryer must be connected to the cold water faucet using
the new inlet hoses. Do not use old hoses.
f1. urn cold water off, remove and
replace rubber washer
®
®
®
Turn cold water faucet off and remove washer inlet hose.
Check and see if rubber washer is in the "Y" connector.
Remove old rubber washer from inlet hose and replace with
new rubber washer provided.
1®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
12
Attach short hose and
"Y" connector
valve and tighten coupling
(279 ram)
If space permits, attach the female end of the "Y" connector
to the cold water faucet. See figure A.
If "Y" connector cannot be attached directly to the cold water
faucet, the short hose must be used. See figure B. Attach
short hose to cold water faucet. Screw on coupling by hand
until it is seated on faucet. Then attach "Y" connector to the
male end of the short hose. Screw on coupling by hand until
it is seated on connector.
Attach other end of long hose
to fill valve at bottom of dryer
back panel. Screw on coupling
by hand until it is seated on fill
valve connector. Using pliers,
tighten the couplings an additional
two-thirds turn.
NOTE: Do not overtighten. Damage
to the coupling can result.
Using pliers, tighten the couplings with additional
two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
Turn on cold water faucet
Check that the water faucets are turned on.
connector and tighten couplings
Check for leaks
One end of the long hose has a wire mesh strainer inside the
coupling. Attach this end to the "Y" connector. Attach washer
cold inlet hose to other side of "Y" connector. Screw on
coupling by hand until it is seated on connector. Using pliers,
tighten the couplings an additional two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
Check for leaks around "Y" connector, faucets, and hoses.
13
CONNECT _NT
, Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
2, Move dryer to final location
LEVEL DR_R
1, Level Dryer
Place
level _
Place
level here
Check levelness of dryer from side to side. Repeat from
front to back.
NOTE: The dryer must be level for the moisture sensing
system to operate correctly.
Not Level LEVEL Not Level
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove cardboard from under dryer.
:2, Adjust leveling legs
If dryer is not level, prop up using a wood block, use wrench
to adjust legs by backing out the foot as needed, then checking
again for levelness. Once legs are level, make sure all four legs
are snug against the floor.
14
COMPLETE INSTAL ION
[_ Check that all parts are now installed. If there is an extra
part, go back through steps to see what was skipped.
[_ Check that you have all of your tools.
[_ Dispose of/recycle all packaging materials.
[_ Be sure the water faucets are on.
[_ Check for leaks around "Y" connector, faucets, and hoses.
[_ Check dryer's final location. Be sure vent is not crushed
or kinked.
[_ Check that dryer is level. See "Level Dryer".
[_ Remove film on console and any tape remaining on dryer.
[_ Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
[_ Read "Dryer Use" in your "Use and Care Guide".
[_ If you live in a hard water area, use of a water softener is
recommended to control the buildup of scale through the
water system in the dryer. Over time, the buildup of lime
scale may clog different parts of the water system, which will
reduce product performance. Excessive scale buildup may
lead to the need for certain part replacement or repair.
Electric Models:
[_ Plug into a grounded outlet.
Gas Models:
[_ Check that gas supply is on.
[_ Check for leaks.
All Models:
[_ Select aTimed Dry heated cycle, and start dryer. Do not
select Air Only Temperature setting.
If dryer will not start, check the following:
* Controls are set in a running or "On" position.
* Start button has been pushed firmly.
* Dryer is plugged into an outlet and/or electrical supply is
connected.
* Household fuse is intact and tight, or circuit breaker has
not tripped.
* Dryer door is closed.
This dryer automatically runs an installation diagnostic routine
at the start of its first cycle.
NOTE: You may notice an odor when dryer is first heated. This
odor is common when heating element is first used. The odor will
go away.
RE RSE DOOR SWING
You can change your door swing from a right-side opening
to a left-side opening, if desired.
1. Place a towel or soft cloth on top of dryer or work space
to avoid damaging the surface.
Remove the door assembly
1. Open the dryer door.
2. Remove the bottom screw (B) from each of the two hinges
that attach dryer door to front panel of dryer.
3. Loosen the top screw (A)from each of the two hinges
in Step 2.
A
B
.A
B
4. Remove the dryer door and the hinges by lifting upward
on the door. Lay the door on a flat, covered surface, with
the inside of the door facing up. Remove remaining two
loose screws from dryer front panel.
5. Remove the 4 plastic plugs (A) located outside the dryer
door opening.
6. Install 4 plastic plugs (A) into screw holes in the dryer left
where the hinges were removed in Step 4.
15
Reverse the strike
1. Remove the door strike (A) from the dryer door opening.
2. Remove the cosmetic screw (B) opposite the door strike (A).
A
A. Door strike
B. Cosmetic screw
3, Reinstall the door strike and cosmetic screw on the opposite
side of dryer door opening from where they were removed.
NOTE: Door strike and plugs must be on the same side
of the dryer door opening.
Reinstall the door
1. Removethe 4 screws and two hinges from the dryer door.
j.........
I
2, Replace the 4 screws in the same holes
3, Remove the 4 screws from the opposite side of the door.
4, Install the two hinges to the front panel of the dryer using
4 screws. Use the non-slotted side to attach the hinge
to the front panel.
5, Install screws in top hinge holes in the door. Do not tighten
screws. Leave approximately 1/4" (5 mm) of screw exposed.
6, Hang door by placing screw heads into top slotted holes of
hinges and slide door down. Align bottom screw holes in hinge
and door. Install two bottom screws. Tighten all hinge screws.
, 1
7, Close door to engage door strike.
i
16
TROUBLESHOOTING
DRYER OPERATION
Dryer will not run
[] Has a household fuse blown, or has a circuit breaker
tripped?
There may be two household fuses or circuit breakers
for the dryer. Check that both fuses are intact and tight,
or that both circuit breakers have not tripped. Replace
the fuse or reset the circuit breaker. If the problem
continues, call an electrician.
[]
[]
Is the correct power supply available?
Electric dryers require a 240-volt power supply. Check
with a qualified electrician.
Was a regular fuse used?
Use a time-delay fuse.
No heat
[] Has a household fuse blown, or has a circuit breaker
tripped?
The drum may be turning, but you may not have heat.
Elelctric dryers use two household fuses or circuit breakers.
Replace the fuse or reset the circuit breaker. If the problem
continues, call an electrician.
[] is "Check Vent" illuminated on the Airflow screen?
This indicator will show the status of airflow through the
dryer vent. The Detecting light comes on during the sensing
phase at the beginning of a cycle. THe Check Vent light will
come
on if a blocked vent or low airflow issue is detected.
Try the following:
Clean lint screen.
Check to see if the vent run from the dryer to the wall is free
of lint and debris.
Confirm the exterior vent exhaust hood is free of lint and
debris.
Confirm your vent system falls within the recommended run
length and number of elbows for the type of vent you are
using. Refer to "Plan Vent System" for details.
Select a Timed Dry heated cycle, and restart the dryer.
For more information on maintaining good airflow, see
"Check Your Vent System for Good Airflow" in the "Use and
Care Guide". If the message persists, have your entire home
venting run cleaned.
Dryer displaying code message
[] "PF" (power failure), check the following:
Was the drying cycle interrupted by a power failure?
Press and hold START/PAUSE to restart the dryer.
Try the following:
Check to see if a household fuse has blown or circuit breaker
has tripped. Electric dryers use two household fuses or
breakers. Replace the fuse or reset the circuit breaker.
Confirm the power cord is properly installed.
DRYER RESULTS
Clothes are not drying satisfactorily, drying times are
too long, or load is too hot
[] is the lintscreen dogged with lint?
Lint screen shold be cleaned before each load.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
Is the exhaust vent or outside exhaust hood clogged with
lint, restricting air movement?
Run the dryer for 5-10 minutes. Hold your hand under
the outside exhaust hood to check air movement. If you
do not feel air movement, clean exhaust system of lint or
replace exhaust vent with heavy metal or flexible vent. See
"Installation Instructions'.
[]
[]
Are fabric softener sheets blocking the grille?
Use only one fabric softener sheet, and use it only once.
Is the exhaust vent the correct length?
Check that the exhaust vent is not too long or has too
many turns. Long venting will increase drying times. See
"Installation Instructions".
[]
[]
Is the exhaust vent diameter the correct size?
Use 4" (102 mm) diameter vent material.
is the dryer located in a room with temperature below
45°F (7°C)?
Proper operation of dryer cycles requires temperatures
above 45°F (7°C).
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
[]
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, consult a qualified electrician.
"F" Variable (F1E1, F2E2, F3E1, F3E2, FTE1, F3E6, F3ET}
service codes:
Call for service.
Is the dryer located in a closet?
Closet doors must have ventilation openings at the top and
bottom of the door. The front of the dryer requires a minimum
of 1" (25 mm) of airspace, and, for most installations, the
rear of the dryer requires 5" (127 mm). See "Installation
Instructions".
17
p p p
$ECURITE DE LA $ECHEUSE
Votre s_curit_ et celle des autres est tr_s irnportante.
Nous donnons de nombreux messages de securit6 importants dans ce manuel et sur votre appareil m6nager. Assurez-vous de
toujours lire tousles messages de s6curit6 et de vous y conformer.
Voici le symbole d'alerte de s_curit&
Ce symbole d'alerte de s6curit6 vous signale les dangers potentiels de d6c_s et de blessures graves &vous
et &d'autres.
Tous les messages de securit6 suivront le symbole d'alerte de s6curit6 et le mot "DANGER" ou
"AVERTISSEMENT". Ces mots signifient :
Risque possible de d_c_s ou de blessure grave si vous ne
suivez pas imm_diaternent les instructions.
Risque possible de d_c_s ou de blessure grave si vous
ne suivez pas les instructions.
Tousles messages de s6curit6 vous diront quel est le danger potentiel et vous disent comment r6duire le risque de blessure et
ce qui peut se produire en cas de non=respect des instructions.
AVERT|SSEMENT d,i.oo°dio,,
m
m
m
L'installation de la s6cheuse a linge dolt _tre effectu6e par un installateur qualifi_.
Installer la s_cheuse conforrn_rnent aux instructions du fabricant et aux codes Iocaux,
Ne pas installer de s_cheuse a linge avec des mat_riau× d'_vacuation en plastique
souple ou un conduit m6tallique souple (de type papier d'aluminium). Si un conduit
m_tallique souple est installS, celui-ci doit 6tre d'un type sp6cifique identifi6 par le
fabricant de I'appareil et convenir & une utilisation avec les s6cheuses a linge. Les
mat6riaux d'6vacuation soupies sont connus pour s'affaisser, 6tre facilement _cras6s
et bloquer la charpie, Ces situations obstrueront le d6bit d'air de la s6cheuse _ linge et
augmenteront le risque d'incendie,
Pour r_duire le risque de blessure grave ou de d_c_s, suivre routes
les instructions d'installation.
Conserver ces instructions.
Pour mettre I'ancienne s6cheuse au rebut ou pour la remiser, enlever la porte.
18
AVERTISSEMENT : Pour votre s6curit6, les renseignements dans ce manuel doivent
_tre observ6s pour r6duire au minimum les risques d'incendie ou d'e×plosion ou pour
_viter des dommages au produit, des blessures ou un d6c_s.
- Ne pas entreposer ou utiliser de I'essence ou d'autres vapeurs ou liquides
inflammables a proximit_ de cet appareil ou de tout autre appareil _lectrom_nager.
- QUE FAIRE DANS LE CAS D'UNE ODEUR DE GAZ :
Ne pas tenter d'allumer un appareil.
= Ne pas toucher a un commutateur 61ectrique; ne pas utiliser le t616phone se trouvant
sur les lieu×.
® l_vacuer tous les gens de la piece, de 1'6difice ou du quarrier.
®Appeler imm6diatement le foumisseur de gaz d'un t_16phone voisin. Suivre ses
instructions.
= A d6faut de joindre votre fournisseur de gaz, appeler les pompiers.
- L'installation et I'entretien doivent _tre effectu6s par un installateur qualifi_, une
agence de service ou le fournisseur de gaz.
AVERTISSEMENT : L'odorat ne permet pas toujours la detection d'une fuite de gaz.
Les distributeurs de gaz recommandent I'emploi d'un detecteur de gaz (homologation UL ou CSA).
Pour d'autre information, contacter le fournisseur de gaz local.
En cas de d6tection d'une fuite de gaz, ex6cuter les instructions "Que faire dans le cas d'une odeur de gaz".
iMPORTANT : L'installation du gaz doit se conformer aux codes Iocaux, ou en I'absence de codes Iocaux, au code canadien
d'installation Bt49.1 du gaz naturel ou du propane.
La secheuse doit _tre 61ectriquement reli6e & la terre conformement aux codes Iocaux, ou en I'absence de codes Iocaux, au Code
canadien de I'electricit6, CSA C22.1.
Dans I'#tat du Massachusetts, les instructions d'installation suivantes sont applicables :
[] Les travaux d'installation et r6paration doivent 6tre ex6cut6s par un plombier ou tuyauteur qualifi6 ou licenci6, ou par le
personnel qualifi6 d'une entreprise licenci6e par I'Etat du Massachusetts.
[] Si une vanne & boisseau sph6rique est utilis6e, elle dolt comporter une manette "T".
[] Si un conduit de raccordement flexible est utilise, sa Iongueur ne doit pas depasser 3 pi.
19
EXIGNNCNS D IN$ LATION
OUTILLAGE ET PIECES
Rassembler les outils et composants n6cessaires avant
d'entreprendre I'installation. Lire et observer les instructions
fournies avec chacun des outils de la liste ci-dessous.
Outils n6cessaires _ toutes les installations :
Outils n6cessaires pour les installations _ gaz :
Tournevis & lame plate
Niveau
Couteau utilitaire
Cisaille de ferblantier
(pour I'installation d'un
nouveau conduit)
Metre-ruban
20
Cl6 b,molette avec ouverture
jusqu'a 1" (25 mm) ou cl6
douille hexagonale
Brides de conduit
Pistolet a calfeutrage et
compos6 de calfeutrage
(pour I'installation d'un
nouveau conduit
d'6vacuation)
Tourne-6crou de 1/4"
(6 mm) (recommand6)
Pince
CI6 a tuyau de 8" (203 mm)
ou 10" (254 mm)
CI6 a mollette de 8" (203 mm)
ou 10" (254 mm)
(pour le raccordement au gaz)
Compos6 d'6tanch6it6 des
raccords filet6s - r6sistant
au gaz propane
Pi_ces fournies (tous les modules) :
Pieds de nivellement (4)
Pi_ces fournies (modUles _ vapeur) :
Tuyau d'alimentation
de 2' (0,6 m)
Tuyau d'alimentation
de 5' (1,5 m)
Rondelle en caoutchouc
Retirer lesachet de pieces du tambour de la s6cheuse. V6rifier
que toutes les pieces sont pr6sentes.
Pi_ces n6cessaires : (Non fourni avec la secheuse)
Consulter les codes Iocaux. V6rifier I'alimentation 61ectrique et le
circuit d'6vacuation existants. Voir "Installations 61ectriques" et
"Exigences concernant 1'6vacuation" avant d'acheter les pieces.
Les installations pour maison mobile n6cessitent un
systeme d'6vacuation en m6tal disponible chez le revendeur
aupres duquel vous avez achet6 votre s6cheuse. Pour plus
d'informations, voir la section "Assistance ou service" dans le
"Guide d'utilisation et d'entretien".
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Maytag WGD8200YW3 Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues