Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid
the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
____________________
Information in this document is subject to change without notice.
© 2004 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: RapidRails and VersaRails are trademarks of Dell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names
or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
May 2004 P/N N2963 Rev. A00
Contents 1-3
Contents
Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
SAFETY: Rack Mounting of Systems
. . . . . . . . . . . . . . . . . 1-5
Installation Instructions
. . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Before You Begin
. . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Installation Tasks
. . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Recommended Tools and Supplies
. . . . . . . . . . . . . . . . . . 1-7
RapidRails Rack Kit Contents
. . . . . . . . . . . . . . . . . . . . 1-7
VersaRails Rack Kit Contents
. . . . . . . . . . . . . . . . . . . . 1-8
Removing the Rack Doors
. . . . . . . . . . . . . . . . . . . . . . . . 1-9
Marking the Rack
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Installing the RapidRails Slide Assemblies
. . . . . . . . . . . . . . . . 1-11
Installing the VersaRails Slide Assemblies
. . . . . . . . . . . . . . . . 1-12
Installing the System in the Rack
. . . . . . . . . . . . . . . . . . . . . 1-14
Installing the Cable-Management Arm
. . . . . . . . . . . . . . . . . . 1-15
Installing the Cable Tray
. . . . . . . . . . . . . . . . . . . . . . . 1-15
Securing the Cable-Management Arm
. . . . . . . . . . . . . . . . 1-15
Replacing the Rack Doors
. . . . . . . . . . . . . . . . . . . . . . . . 1-19
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21
1-4 Contents
Figures
Figure 1-1. RapidRails Rack Kit Contents . . . . . . . . . . 1-8
Figure 1-2. VersaRails Rack Kit Contents
. . . . . . . . . . 1-9
Figure 1-3. One Rack Unit
. . . . . . . . . . . . . . . . . . 1-10
Figure 1-4. Marking the Vertical Rails
. . . . . . . . . . . . 1-11
Figure 1-5. Installing the RapidRails Slide Assemblies
. . . . 1-12
Figure 1-6. Installing the VersaRails Rail Assemblies
. . . . . 1-13
Figure 1-7. Installing the System in the Rack
. . . . . . . . . 1-15
Figure 1-8. Installing the Cable-Management Arm
. . . . . . 1-16
Figure 1-9. Installing the System Status Indicator Cable
(If Applicable)
. . . . . . . . . . . . . . . . . 1-17
Figure 1-10. Routing the Power Cords
. . . . . . . . . . . . 1-18
Rack Installation Guide 1-5
Safety Instructions
Use the following safety guidelines to ensure your own personal safety and to help protect your
system and working environment from potential damage. For complete safety information,
see the
Product Information
Guide
.
SAFETY: Rack Mounting of Systems
Observe the following precautions for rack stability and safety.
Systems are considered to be components in a rack. Thus, "component" refers to any system as well
as to various peripherals or supporting hardware.
CAUTION: Installing systems in a rack without the front and side stabilizers installed could cause the
rack to tip over, potentially resulting in bodily injury under certain circumstances. Therefore, always
install the stabilizers before installing components in the rack.
After installing system/components in a rack, never pull more than one component out of the rack on its
slide assemblies at one time. The weight of more than one extended component could cause the rack
to tip over and injure someone.
NOTE: Your system is safety-certified as a free-standing unit and as a component for use in a rack
cabinet using the customer rack kit when both the rack cabinet and rack kit were designed for your
system. The installation of your system and rack kit in any other rack cabinet has not been approved by
any safety agencies. It is your responsibility to have the final combination of system and rack kit in a
cabinet evaluated for suitability by a certified safety agency. The manufacturer disclaims all warranties
and liability in connection with such combinations.
System rack kits are intended to be installed in an approved rack by trained service
technicians. If you install the kit in any other rack, be sure that the rack meets the
specifications.
Before working on the rack, make sure that the stabilizers are secured to the rack, extended to
the floor, and that the full weight of the rack rests on the floor. Install front and side stabilizers
on a single rack or front stabilizers for joined multiple racks before working on the rack.
Always load the rack from the bottom up, and load the heaviest item in the rack first.
Make sure that the rack is level and stable before extending a component from the rack.
Use caution when pressing the component rail release latches and sliding a component
into or out of a rack; the slide rails can pinch your fingers.
After a component is inserted into the rack, carefully extend the rail into a locking position,
and then slide the component into the rack.
Do not overload the AC power supply branch circuit that provides power to the rack.
The total rack load should not exceed 80 percent of the branch circuit rating.
Ensure that proper airflow is provided to components in the rack.
Do not step on or stand on any system/component when servicing other components
in a rack.
1-6 Rack Installation Guide
Installation Instructions
This installation guide provides instructions for trained service technicians installing one or more
systems in an open-frame relay rack or in a rack cabinet. The RapidRails™ rack kit can be installed
without tools in manufacturer’s rack cabinets that have square holes; the VersaRails™ rack kit can
be installed in most industry-standard rack cabinets that have square or round holes. The
procedures for installing both RapidRails and VersaRails rack kits are similar. One rack kit is
required for each system installed in the rack.
CAUTION: Do not install rack kit components designed for another system. Use only the rack kit for
your Dell system. Using the rack kit for another system may result in damage to the system and personal
injury.
NOTE: If your system is a tower version, you must install a tower-to-rack conversion kit. Instructions
for installing this kit are included in a separate document.
The RapidRails rack kit can be installed in most industry-standard rack cabinets.
NOTICE: The VersaRails rack kit is intended to be installed by trained service technicians in a rack that
meets the specifications of American National Standards Institute (ANSI)/Electronic Industries
Association (EIA) standard ANSI/EIA-310-D-92, International Electrotechnical Commission (IEC) 297, and
Deutsche Industrie Norm (DIN) 41494. One rack kit is required for each system that is installed in a rack.
Before You Begin
Before you begin installing your system in the rack, carefully read the safety instructions found
at the beginning of this guide, as well as the safety instructions found in your system’s
Product
Information Guide
for additional information.
CAUTION: When installing multiple systems in a rack, complete all of the procedures for the current
system before attempting to install the next system.
CAUTION: Rack cabinets can be extremely heavy and move easily on the casters. The cabinet has no
brakes. Use extreme caution while moving the rack cabinet. Retract the leveling feet when relocating
the rack cabinet. Avoid long or steep inclines or ramps where loss of cabinet control may occur. Extend
the leveling feet for support and to prevent the cabinet from rolling.
Important Safety Information
Observe the safety precautions in the following subsections when installing your system in the rack.
CAUTION: You must strictly follow the procedures in this document to protect yourself as well as
others who may be involved. Your system may be very large and heavy, and proper preparation and
planning are important to prevent injury to yourself and to others. This becomes increasingly important
when systems are installed high up in the rack.
Rack Stabilizer Feet
CAUTION: Installing systems in a rack without the front and side stabilizer feet installed could cause
the rack to tip over, potentially resulting in bodily injury under certain circumstances. Therefore,
always install the stabilizer feet before installing components in the rack.
Rack Installation Guide 1-7
CAUTION: After installing systems in a rack, never pull more than one system out of the rack on its
slide assemblies at one time. The weight of more than one extended system could cause the rack to tip
over and cause injury.
The stabilizer feet help prevent the rack from tipping over when a system or other component is
pulled out of the rack with the slide assemblies fully extended. See the documentation provided
with the rack cabinet for instructions on installing and anchoring the stabilizer feet.
Installation Tasks
Installing a rack kit involves performing the following tasks in their numbered order:
1
Removing the rack doors
2
Marking the rack (if necessary)
3
Installing the rail assemblies in the rack:
RapidRails installation
VersaRails installation
4
Installing the system in the rack
5
Installing the cable-management arm
6
Routing cables
7
Replacing the rack doors
Recommended Tools and Supplies
A #2 Phillips screwdriver
A T-10 Torx driver (if installing the tower-to-rack kit)
Masking tape or a felt-tip pen, for use in marking the mounting holes to be used
A measuring ruler or tape measure
RapidRails Rack Kit Contents
The RapidRails rack kit includes the following items (see Figure 1-1):
One pair of RapidRails slide assemblies
One cable-management arm
One cable-management arm retainer
One cable tray
1-8 Rack Installation Guide
Figure 1-1. RapidRails Rack Kit Contents
VersaRails Rack Kit Contents
The VersaRails rack kit includes the following items (see Figure 1-2):
One pair of VersaRails slide assemblies
One cable-management arm
One cable-management arm retainer
One cable tray
Eight 10-32 x 0.5-inch flange-head Phillips screws
NOTE: The nonmetric screws described in illustrations and in procedural steps are identified by size and
number of threads per inch. For example, a #10 Phillips-head screw with 32 threads per inch is identified
as a 10-32 screw.
RapidRails slide assemblies
cable-management arm
cable tray
cable-management arm retainer
system status indicator cable
(if applicable)
Rack Installation Guide 1-9
Figure 1-2. VersaRails Rack Kit Contents
Removing the Rack Doors
See the procedures for removing doors in the documentation provided with your rack cabinet.
CAUTION: Because of the size and weight of the rack cabinet doors, never attempt to remove or install
them by yourself.
CAUTION: Store the two doors where they will not injure someone if the doors accidently fall over.
10-32 x 0.5-inch flange-
head Phillips screws (8)
VersaRails slide assemblies
cable-management arm
cable tray
cable-management arm retainer
system status indicator cable
(if applicable)
1-10 Rack Installation Guide
Marking the Rack
NOTE: Your rack may already be marked and not require this procedure.
You must allow 5 U (8.75 inches) of vertical space for each system you install in the rack
(see Figure 1-3).
Figure 1-3. One Rack Unit
CAUTION: If you are installing more than one system, install the slide assemblies so that the first
system is installed in the lowest available position in the rack.
To mark the rack, perform the following steps:
1
Place a mark on the rack’s front vertical rails where you want to locate the bottom of
the system you are installing in the rack cabinet.
The bottom of each 1-U space is at the middle of the narrowest metal area between holes
(marked with a horizontal line on some rack cabinets—see Figure 1-4).
2
Place a mark approximately 8.75 inches above the original mark you made (or count up
15 holes in a rack that meets EIA-310 standards) and mark the rack’s front vertical rails with
a felt-tipped pen or masking tape (if you counted holes, place a mark just above the top hole).
This mark or piece of tape indicates where the system’s upper edge will be located on the
vertical rails (see Figure 1-4).
1 U (44 mm or 1.75 inches)
12.7 mm (0.5 inch)
15.9 mm (0.625 inch)
15.9 mm (0.625 inch)
12.7 mm (0.5 inch)
Rack Installation Guide 1-11
Figure 1-4. Marking the Vertical Rails
Installing the RapidRails Slide Assemblies
1
At the front of the rack cabinet, position one of the RapidRails slide assemblies so that
its mounting-bracket flange fits in the appropriate location on the rack (see Figure 1-5).
The top mounting hook on the rail assembly’s front-mounting bracket flange should enter
the top hole between the marks on the vertical rails.
2
Push the slide assembly forward until the top mounting hook enters the square hole just
below the upper marks or tape you placed on the vertical rail. Next, push down on the
mounting-bracket flange until the mounting hooks seat in the square holes and the push
button pops out and clicks (see Figure 1-5).
3
At the back of the cabinet, pull back on the mounting-bracket flange until the mounting
hooks are in the appropriate hole, and then push down on the flange until the mounting
hooks seat in the square holes and the push button pops out and clicks.
tape on vertical rail
1-12 Rack Installation Guide
4
Repeat steps 1 through 3 for the slide assembly on the other side of the rack.
NOTE: Ensure that the rails are mounted at the same vertical position on both sides of the rack.
Figure 1-5. Installing the RapidRails Slide Assemblies
Installing the VersaRails Slide Assemblies
1
At the front of the rack cabinet, place a VersaRails slide assembly so that its mounting-bracket
flange fits between the marks or tape (or numbered location) on the rack (see Figure 1-6).
The holes on the front of the mounting bracket should align with the holes between the
marks on the front vertical rail.
2
Install two 10-32 x 0.5-inch flange-head Phillips screws in the mounting flange’s top hole and
the bottom hole (see Figure 1-6).
slide-assembly
mounting-bracket
flange
push button
front of rack
slide assemblies (2)
mounting hooks
Rack Installation Guide 1-13
3
At the back of the cabinet, pull back on the mounting-bracket flange until the mounting
holes align with their respective holes on the back vertical rail.
4
Install two 10-32 x 0.5-inch flange-head Phillips screws in the back mounting flange’s first
and third holes to secure the slide assembly to the back vertical rail.
5
Repeat steps 1 through 4 for the slide assembly on the other side of the rack.
NOTE: Ensure that the rails are mounted at the same vertical position on both sides of the rack.
Figure 1-6. Installing the VersaRails Rail Assemblies
slide-assembly
mounting-bracket flange
front of rack
slide assemblies (2)
1-14 Rack Installation Guide
Installing the System in the Rack
CAUTION: If you are installing more than one system, install the first system in the lowest available
position in the rack.
CAUTION: Never pull more than one component out of the rack at a time.
1
Pull the two interior slide assemblies out of the rack until they lock in the fully-extended
position.
CAUTION: Because of the size and weight of the system, never attempt to install the system in the slide
assemblies by yourself.
2
Lift the system into position.
Using a minimum of two persons, each person should place one hand on the front-bottom
of the system and the other hand on the back-bottom of the system.
3
Tilt the front of the system upward while aligning the back shoulder screws on the sides of
the system with the back slots on the slide assemblies (see Figure 1-7).
4
Engage the back shoulder screws in the slot just behind the slide-release latch, followed by
the middle and front shoulder screws.
5
Push the system inward on the slide assemblies until the system locking mechanism clicks
into place, locking the slide to the system (see Figure 1-7).
6
Pull up on the slide-release latches and push the system into the rack.
7
Tighten the thumbscrews on the rack front panel.
Rack Installation Guide 1-15
Figure 1-7. Installing the System in the Rack
Installing the Cable-Management Arm
This procedure is performed in two phases. First, install the cable tray into the back of the system
chassis. Next, install the cable-management arm on either side of the cable tray.
Installing the Cable Tray
Attach the cable tray to the system chassis using four of the metal tabs at the bottom of the tray
and two 6-32 x 0.25-inch hex-head Phillips screws (see Figure 1-8).
CAUTION: The cable tray cannot support the weight of the system. Do not grasp the cable tray when
lifting the system. Lift the system only by the chassis edges.
Securing the Cable-Management Arm
1
Facing the back of the rack cabinet, locate the tab on the end of the slide assembly
(see Figure 1-8).
system-locking mechanism
1-16 Rack Installation Guide
Figure 1-8. Installing the Cable-Management Arm
2
Push the tab on the back end of the cable-management arm into the latch on the end of
the slide assembly (see Figure 1-8).
The latch clicks when locked.
3
Push the tab on the front end of the cable-management arm into a matching latch on the
inner segment of the slide assembly (see Figure 1-8).
The latch clicks when locked.
4 Install the system status indicator cable plug into its connector (see Figure 1-9).
5 Open the wire covers on the cable-management arm by lifting the center of the wire over
the top of the embossed round button on the front of the forward part of the arm and
lifting the wire over the top of a similar round button on the back part of the arm.
The wire cover swings open to enable cables to be routed within the arm.
6 Route the system status indicator end of the cable through the cable-management arm,
and install the indicator in its slot at the back end of the cable-management arm
(see Figure 1-9).
cable-management arm
back of system
captive
thumbscrew
cable tray
back of rack
metal tabs
cable-management
arm retainer
Rack Installation Guide 1-17
7
Connect the power cables to their receptacles on the system back panel.
NOTE: Use the strain-relief loop (if available) on the back of the system to provide strain relief for
the power cables.
Figure 1-9. Installing the System Status Indicator Cable (If Applicable)
8
Connect the power cords to their receptacles on the back panel (see Figure 1-10).
CAUTION: Allow some slack in each cable as you route them around hinges in the cable-management
arm.
9
Attach the I/O cable connectors to their respective connectors on the system back panel.
10
Attach the I/O cable connectors to their respective connectors on the system back panel.
For details on cable connections, see your system’s Installation and Troubleshooting Guide
and your User’s Guide.
11 Route the power and I/O cables through the cable-management arm, using four loosely
secured tie-wraps (two in the middle and one on each end of the cable-management arm).
Do not fully tighten the tie-wraps at this time (see Figure 1-10).
Allow some cable slack in the cable-management arm to prevent damage to the cables.
system status
indicator cable plug
system
status
indicator
1-18 Rack Installation Guide
12 Secure the cables to the cable-management arm:
a After connecting the cables to the system, unscrew the thumbscrews that secure the
front of the system to the front vertical rail.
b Slide the system forward to the fully extended position.
c Route the cables along the cable-management arm, make any adjustments needed to
the cable slack at the hinge positions, secure the cables to the cable-management arm
with the straps, and close the wire covers over the cable-management arm.
NOTE: As you pull the system out to its furthest extension, the slide assemblies will lock in the
extended position. To push the system back into the rack, press the slide release latch on the side
of the slide, and then slide the system completely into the rack.
Figure 1-10. Routing the Power Cords
13
Slide the system in and out of the rack to verify that the cables are routed correctly and do
not bind, stretch, or pinch with the movement of the cable-management arm.
14 Open the wire cover of the cable-management arm and tighten the straps just enough to
ensure that the cable slack is neither too tight to cause excessive pinching nor too loose, yet
keep the cables from slipping as the system is moved in and out of the rack.
15
Secure the cable-management arm retainer to the back of the rack using the captive
thumbscrews (see Figure 1-8).
power cord plug
power receptacle housing
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112

Dell PowerEdge 1800 Guide de démarrage rapide

Taper
Guide de démarrage rapide