Whirlpool PK 750 RT GH AUS Mode d'emploi

Catégorie
Plaques de cuisson
Taper
Mode d'emploi

Ce manuel convient également à

PK 750 RT GH AUS
PK 640 R GH AUS
English
Operating Instructions
HOB
Français
Mode d’emploi
TABLE DE CUISSON
Español
Manual de instrucciones
ENCIMERA
Contents
Operating Instructions,1
Warnings,2
Assistance,4
Description of the appliance,5
Installation,7
Start-up and use,12
Precautions and tips,13
Maintenance and care,13
Troubleshooting,14
Sommaire
Mode d’emploi,1
Avertissements,2
Assistance,4
Description de l’appareil,5
Installation,15
Mise en marche et utilisation,21
Précautions et conseils,22
Nettoyage et entretien,23
Anomalies et remèdes,23
Sumario
Manual de instrucciones,1
Advertencias,3
Asistencia,4
Descripción del aparato,6
Instalación,24
Puesta en funcionamiento y uso,30
Precauciones y consejos,31
Mantenimiento y cuidados,31
Anomalías y soluciones,32
2
Warnings
WARNING: The appliance and its
accessible parts become hot during use.
Care should be taken to avoid touching
heating elements. Children less than 8
years of age shall be kept away unless
continuously supervised. This appliance
can be used by children aged from 8 years
and above and persons with reduced
physical, sensory or mental capabilities
or lack of experience and knowledge
if they have been given supervision
or instruction concerning use of the
appliance in a safe way and understand
the hazards involved. Children shall not
play with the appliance. Cleaning and
user maintenance shall not be made by
children without supervision.
WARNING: Unattended cooking on a hob
with fat or oil can be dangerous and may
result in re. NEVER try to extinguish a
re with water, but switch off the appliance
and then cover ame e.g. with a lid or a
re blanket.
WARNING: Danger of re: do not store
items on the cooking surfaces.
Never use steam cleaners or pressure
cleaners on the appliance.
Remove any liquid from the lid before
opening it. Do not close the glass cover (if
present) when the gas burners or electric
hotplates are still hot.
The appliance is not intended to be
operated by means of an external timer
or separate remote control system.
CAUTION: the use of inappropriate hob
guards can cause accidents.
Avertissements
ATTENTION : Cet appareil ainsi que ses
parties accessibles deviennent très chauds
pendant leur fonctionnement. Il faut faire
attention à ne pas toucher les éléments
chauffants. Ne pas faire approcher les
enfants de moins de 8 ans à moins qu’ils
ne soient sous surveillance constante.
Le présent appareil peut être utilisé par
des enfants de plus de 8 ans et par des
personnes présentant des capacités
physiques, sensorielles ou mentales
réduites ou n’ayant pas l’expérience ou les
connaissances indispensables, à condition
qu’ils soient sous bonne surveillance ou
qu’ils aient reçu les instructions nécessaires
pour une utilisation de l’appareil en toute
sécurité et à condition qu’ils se rendent
compte des dangers encourus. Les enfants
ne doivent pas jouer avec l’appareil. Les
opérations de nettoyage et d’entretien ne
doivent pas être effectuées par des enfants
non surveillés.
ATTENTION : Laisser un récipient de
cuisson avec de l’huile ou de la graisse sur
un foyer est dangereux et risque d’entraîner
un incendie. Il ne faut JAMAIS essayer
d’éteindre une amme ou un incendie avec
de l’eau ! Il faut éteindre l’appareil et couvrir
la amme avec un couvercle, par exemple,
ou avec une couverture anti-feu.
ATTENTION : Risque d’incendie : ne
pas laisser d’objets sur les surfaces de
cuisson.
Ne jamais nettoyer l’appareil avec des
nettoyeurs vapeur ou haute pression.
Essuyer tout liquide pouvant se trouver
sur le couvercle avant de l’ouvrir. Ne pas
abaisser le couvercle en verre (s’il y en a
3
un) tant que les brûleurs gaz ou la plaque
électrique sont chauds.
Cet appareil ne peut pas être allumé au
moyen d’un temporisateur extérieur ou
d’un système de commande à distance
séparé.
ATTENTION : l’utilisation de protections
de table inappropriées peut causer des
incendies.
Advertencias
ATENCIÓN: Este aparato y sus partes
accesibles se vuelven muy calientes
durante el uso. Por lo tanto, es importante
evitar tocar los elementos calentadores.
Mantenga alejados a los niños menores
de 8 años si no son continuamente
vigilados. El presente aparato puede ser
utilizado por niños mayores de 8 años y
por personas con capacidades físicas,
sensoriales o mentales disminuidas o
sin experiencia ni conocimientos, si se
encuentran bajo una adecuada vigilancia
o si han sido instruidos sobre el uso del
aparato de modo seguro y comprenden
los peligros relacionados con el mismo.
Los niños no deben jugar con el aparato.
Las operaciones de limpieza y de
mantenimiento no deben ser realizadas
por niños sin vigilancia.
ATENCIÓN: Dejar un quemador con
grasas o aceites sin vigilancia puede ser
peligroso y provocar un incendio. NUNCA
intente apagar una llama/incendio con
agua, se debe apagar el aparato y cubrir
la llama, por ejemplo, con una tapa o con
una manta ignífuga.
ATENCIÓN: Riesgo de incendio: no deje
objetos sobre las supercies de cocción.
No utilice nunca limpiadores a vapor o de
alta presión para la limpieza del aparato.
Elimine eventuales líquidos presentes
sobre la tapa antes de abrirla. No cierre
la tapa de vidrio (si existe) cuando los
quemadores o la placa eléctrica todavía
están calientes.
El aparato no se debe poner en
funcionamiento a través de un
temporizador externo o de un sistema
de mando a distancia.
ATENCIÓN: el uso de protecciones
inapropiadas de la placa de cocción
puede provocar accidentes.
4
Assistance
Communicating:
appliance model (Mod.)
serial number (S/N)
This information is found on the data plate located on the
appliance and/or on the packaging.
! Never use unauthorised technicians and never accept
replacement parts which are not original.
Assistance
Indiquez-lui :
le modèle de votre appareil (Mod.)
son numéro de série (S/N)
Ces informations gurent sur la plaquette signalétique
apposée sur votre appareil et/ou sur son emballage.
! Ne faites jamais appel à des techniciens non agréés et
refusez toujours l’installation de pièces détachées non
originales.
Asistencia
Comunique:
el modelo de la máquina (Mod.)
el número de serie (S/N)
Esta información se encuentra en la placa de características
ubicada en el aparato y/o en el embalaje.
! No recurra nunca a técnicos no autorizados y rechace
siempre la instalación de repuestos no originales.
La siguiente información es válida solo para España.
Para otros países de habla hispana consulte a su
vendedor.
Ampliación de garantía
Llame al 902.363.539 y le informaremos sobre el fantástico
plan de ampliación de garantía hasta 5 años.
Consiga una cobertura total adicional de
Piezas y componentes
Mano de obra de los técnicos
Desplazamiento a su domicilio de los técnicos
Y NO PAGUE AVERIAS NUNCA MAS
Servicio de asistencia técnica (SAT)
Llame al 902.133.133 y nuestros técnicos intervendrán con
rapidez y ecacia, devolviendo el electrodoméstico a sus
condiciones óptimas de funcionamiento.
En el SAT encontrará recambios, accesorios y productos
específicos para la limpieza y mantenimiento de su
electrodoméstico a precios competitivos.
ESTAMOS A SU SERVICIO
ARISTON
PRIORITY SERVICE
If you are not completely satised with your appliance or
require service call:
Australia
Phone: 1300 815 589
New Zealand
Phone: (09) 306 1020
AUSTRALIA
ARISIT PTY LIMITED
40-44 Mark Anthon
y Drive, Dandenong South,
VIC 3175, A
ustralia
F
ax: Service & Sales (03) 9768 0838
Email: consumer
GENUINE ACCESSORIES
& SPARE PARTS
A wide range of genuine
accessories are available for your appliance call:
Australia
Phone: 03 9768 0888
New Zealand
Phone: (09) 306 1020
NEW ZEALAND
ARISIT PTY LIMITED
PO Box 68-140 Newton, Auckland
1145, New Zealand
Fax: (09) 302 0077
5
Description of the appliance
Overall view
1. Support Grid for COOKWARE
2. GAS BURNERS
3. Control Knobs for GAS BURNERS
4. Ignition for GAS BURNERS*
5. SAFETY DEVICES*
GAS BURNERS differ in size and power. Use the
diameter of the cookware to choose the most appropriate
burner to cook with.
Control Knobs for GAS BURNERS adjust the size of the
ame.
GAS BURNER IGNITION* enables a specic burner to
be lit automatically.
SAFETY DEVICE* stops the gas ow if the ame is
accidentally extinguished.
* Only available on certain models.
Description de l’appareil
Vue d’ensemble
1. Grilles support de CASSEROLES
2. BRÛLEURS À GAZ
3. Manettes de commande des BRÛLEURS GAZ
4. Bougie d’allumage des BRÛLEURS GAZ*
5. DISPOSITIF DE SÉCURITÉ*
BRÛLEURS GAZ ils ont plusieurs dimensions et
puissances. Choisissez celui qui correspond le mieux
au diamètre de votre casserole.
• Manettes de commande des BRÛLEURS GAZ pour le
réglage de la amme.
• La bougie d’allumage des BRÛLEURS GAZ* permet
l’allumage automatique du brûleur sélectionné.
DISPOSITIF DE SÉCURITÉ* en cas d’extinction accidentelle
de la amme, coupez immédiatement l’arrivée du gaz.
* N’existe que sur certains modèles.
1
1
2
2
3
3
5
4
6
Descripción del aparato
Vista en conjunto
1. Parrillas de apoyo para RECIPIENTES DE COCCIÓN
2. QUEMADORES A GAS
3. Mandos de los QUEMADORES A GAS
4. Bujía de encendido de los QUEMADORES A GAS*
5. DISPOSITIVO DE SEGURIDAD*
QUEMADORES A GAS: son de distintas dimensiones
y potencias. Elija siempre el más adecuado para el
diámetro del recipiente que va a utilizar.
• Mandos de los QUEMADORES A GAS para la regulación
de la llama.
• Bujía de encendido de los QUEMADORES A GAS:*
permite el encendido automático del quemador.
DISPOSITIVO DE SEGURIDAD:* si se apaga
accidentalmente la llama, interrumpe la salida de gas.
* Presente sólo en algunos modelos.
1
1
2
2
3
3
5
4
Installation
! Before operating your new appliance please read this
instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.
! Please keep these operating instructions for future
reference. Pass them on to possible new owners of the
appliance.
Compliance with standards
This cooktop must be installed by an authorised person in
accordance with the requirements of local gas and electrical
authorities, as well as the latest published versions of the
following standards:
AS/NZS 5601 Gas installation and pipe sizing
SAA Wiring Rules.
Positioning
! Keep packaging material out of the reach of children. It can
become a choking or suffocation hazard (see Precautions
and tips).
! The appliance must be installed by a qualified and
authorised professional according to the instructions
provided. Incorrect installation may cause harm to people
and animals or may damage property.
Kitchen Ventilation
Where the total input of all appliances exceeds 3 MJ/h for
each cubic metre of the room or enclosure volume, the
space shall be ventilated by one of the methods detailed
below. For the purpose of assessing the adequacy of
ventilation, the space that cannot be isolated by doors is
the ‘volume of a room’.
Natural ventilation direct from outside
Two permanent openings shall be provided directly to
outside. The openings shall be located to ensure the
distance between the top of the upper opening and the
ceiling of the room or enclosure, and the distance between
the bottom of the lower opening and the oor of the room
or enclosure does not exceed 5% of the height of the room
or enclosure. The minimum free ventilation area provided
by each opening shall be calculated using the following
formula:
A = 3 × T
where
A = the minimum free ventilation area (cm
2
)
T = the total gas consumption of all appliances (MJ/h)
The minimum vertical dimension of any free ventilation
opening shall be 6 mm.
NOTE 1 When used in this Clause, the term ‘directly to
outside’ means any one of the following options, provided
that the ventilation path is unobstructed by building material
or insulation:
(a) Directly through an outside wall (preferred option).
(b) Through to an outside wall but offset.
(c) Into a cavity ventilated to outside.
(d) Into an under oor space ventilated to outside.
(e) Into a roof space ventilated to outside.
NOTE 2 The two openings may be combined provided that
the top and bottom of the opening reach the limits set by
this Clause.
Natural ventilation via adjacent room
Two permanent openings shall be provided in the room
or enclosure. The openings shall be located to ensure the
distance between the top of the upper opening and the
ceiling of the room or enclosure, and the distance between
the bottom of the lower opening and the oor of the room
or enclosure does not exceed 5% of the height of the room
or enclosure.
The minimum free ventilation area provided by each opening
shall be calculated using the following formula:
A = 6 × T
where
A = the minimum free ventilation area (cm
2
)
T = the total gas consumption of all appliances (MJ/h)
These requirements shall apply to all subsequent rooms
until a room is ventilated to outside, in accordance with the
previous section, or the total input of the appliances does
not exceed 3 MJ/h for each cubic metre of the total volume
of the enclosure and rooms.
The minimum vertical dimension of any free ventilation
opening shall be 6 mm.
NOTE: The two openings may be combined provided that
the top and bottom of the opening reach the limits set by
this Clause.
Liquid petroleum gas sinks to the oor as it is heavier
than air. Therefore, rooms containing LPG cylinders must
also be equipped with vents to allow gas to escape in
the event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored
in rooms or storage areas that are below ground level
(cellars, etc.). It is advisable to keep only the cylinder
being used in the room, positioned so that it is not subject
to heat produced by external sources (ovens, replaces,
stoves, etc. ) which could raise the temperature of the
cylinder above 50°C.
Adjacent cabinetry
The location of connection points is given in the table on
page 5 . For trouble-free operation of appliances installed in
housing units, the minimum distances shown in g.4 should
be observed. It is recommended that the adjacent kitchen
surfaces should be capable of withstanding temperatures
of 65°C. Also, the following must be observed:
The appliance should be installed next to cabinetry which
is no taller than the top of the cooker hob.
The wall in direct contact with the back panel of the
cooker must be made of non-flammable material.
During operation of the cooker, the back panel of the
cooker could reach a temperature of 50°C above room
temperature.
Kitchen cabinets installed next to the cooker that are
higher than the top of the hob, must be at least 600 mm
from the edge of the hob itself.
If the hood is installed below a wall cabinet, the latter
must be at least 700 mm (millimetres) above the surface
of the hob.
AUS
7
Cabinets installed adjacent to the hood must be at least
420 mm above the hob,
The following minimum clearances
to combustible materials must be
observed:
Minimum clearance from edge
of burner to side wall must be 200
mm.
• Minimum clearance from edge of
burner to rear wall must be 55 mm.
Range hoods
Range hoods and overhead exhaust fans must be installed
according to manufacturers’ instructions but in no case shall
clearance from hob burners be less than 650 mm for range
hoods and 750 mm for overhead exhaust fans.
If the hood is installed below a wall cabinet, the latter
must be at least 700 mm (millimetres) above the surface
of the hob.
Fitting the cooktop above an oven
When installing the cooktop above an oven, both the
electricity supply cable and the gas pipe or exible hose
must not touch hot parts of the oven housing.
When installing above a built-under oven without forced
cooling ventilation, suitable air vents should be provided for
(inlet at least 200 cm² from the bottom, outlet at least 120
cm² from the top part) to allow adequate ventilation inside
the housing unit.
Also a wooden panel should be installed beneath the hob
as insulation, positioning it at a minimum distance of 15 mm
from the hob housing.
Before the installation remove the grids and burners from
the hob and turn it upside down, making sure you don’t
damage the thermocouples and spark plugs.
Apply the seals that come with
the appliance along the outer
edges of the hob to prevent any
passage of air, humidity and
water (see Figure).
For proper application make sure the surfaces to be sealed
are clean, dry and free of any grease/oil.
The installation cavity should have the dimensions
indicated in the gure. Fastening hooks are provided,
allowing you to fasten the hob to tops that are between 20
and 40 mm thick. To ensure the hob is securely fastened
to the top, we recommend you use all the hooks provided.
555 mm
55 mm
475 mm
600mm min.
420mm min.
650mm min.
Hook fastening diagram
20
30
Hooking position Hooking position
for top H=20mm for top H=30mm
Front
40
Hooking position Back
for top H=40mm
! Use the hooks contained in the “accessory pack”.
Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This must
be placed at a minimum distance of 20 mm from the lower
part of the hob.
Ventilation
To ensure adequate ventilation, the back panel of the cabinet
must be removed. It is advisable to install the oven so that it
rests on two strips of wood, or on a completely at surface
with an opening of at least 45 x 560 mm (see diagrams).
560 mm.
45 mm.
Electrical connection
Hobs equipped with a three-pole power supply cable are
designed to operate with alternating current at the voltage and
frequency indicated on the data plate (this is located on the
lower part of the appliance). The earth wire in the cable has a
green and yellow cover. If the appliance is to be installed above
a built-in electric oven, the electrical connection of the hob and
the oven must be carried out separately, both for electrical
safety purposes and to make extracting the oven easier.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load
indicated on the data plate.
The appliance must be directly connected to the mains
using an omnipolar circuit-breaker with a minimum contact
opening of 3 mm installed between the appliance and the
mains. The circuit-breaker must be suitable for the charge
8
AUS
indicated and must comply with current electrical regulations
(the earthing wire must not be interrupted by the circuit-
breaker). The supply cable must not come into contact with
surfaces with temperatures higher than 50°C.
! The installer must ensure that the correct electrical
connection has been made and that it is compliant with
safety regulations.
Before connecting to the power supply, make sure that:
The appliance is earthed and the plug is compliant with
the law.
The socket can withstand the maximum power of the
appliance, which is indicated on the data plate.
The voltage is in the range between the values indicated
on the data plate.
The socket is compatible with the plug of the appliance.
If the socket is incompatible with the plug, ask an
authorised technician to replace it. Do not use extension
cords or multiple sockets.
! Once the appliance has been installed, the power supply
cable and the electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by
authorised technicians only (see Assistance).
! The manufacturer declines any liability should these safety
measures not be observed.
Gas connection
Check The Gas Type
! Before installation, check that the gas type (natural gas
or Universal LPG) of the cooker is suitable for the gas type
available to the installation. It is extremely dangerous to use
the wrong gas type with any appliance, as re or serious
injury can result.
This cooker is supplied from the factory already set for
Natural Gas. To convert the cooker to LPG (or back to
Natural Gas from LPG), follow the directions later in this
section.
Fit regulator supplied for Natural Gas (if applicable) at rear
of appliance, and as close as practicable to the appliance.
It is recommended that an isolating valve and union be
tted, to enable simple disconnection for servicing. These
are to be in an accessible location.
! Check that the pressure of the gas supply is consistent
with the values indicated in Table 1 (“Burner and nozzle
specications”). This will ensure the safe operation and
longevity of your appliance while maintaining efcient
energy consumption.
Pipe or Hose Connection
This appliance is suitable for use with either a exible
connection or rigid copper connection.
Either a rigid metal pipe with ttings in compliance with the
standards in force must be used for connecting to the nipple
union (threaded ½”G male tting) situated at the rear of the
appliance to the right (g.8), or an approved exible hose
of class B or D.
Should it be necessary to turn the fitting, the gasket
(supplied with the appliance) must be replaced.
If a exible hose is used, it should be as short as possible
with a maximum length of 1.2 metres;
The exible connection must be approved to class B or
D of AS/NZS1869 as a minimum.
it should not be bent, kinked or compressed;
it should not be in contact with the rear wall of the
appliance or in any case with parts which may reach a
temperature of 50°C;
it should not come into contact with pointed parts or sharp
corners;
it should not be subject to any pulling or twisting forces;
it should be easy to inspect along its entire length in order
to be able to check its condition.
The supply connection point must be accessible with the
appliance installed.
The inner diameters of the pipe are as follows:
8 mm for LPG;
13 mm for Natural Gas.
Checking the tightness of the connection
Upon completion of installation, check the gas circuit, the
internal connections and the taps for leaks using a soapy
solution (never a ame). Also check that the connecting pipe
cannot come into contact with moving parts which could
damage or crush it. Make sure that the natural gas pipe is
adequate for a sufcient supply to the appliance when all
the burners are lit
Duplicate Data Plate
Where the data plate is obscured by cabinetry when the
cooker is in the installed position, place a duplicate data
plate on a surface of the cabinetry adjacent to the cooker.
Adapting to different types of gas
To adapt the hob to a different type of gas other than default
type (indicated on the rating plate at the base of the hob or
on the packaging), the burner nozzles should be replaced
as follows:
1. Remove the hob grids and slide the burners off their
seats.
2. Unscrew the nozzles using a 7 mm socket spanner, and
replace them with nozzles for the new type of gas (see
table 1 “Burner and nozzle characteristics”).
3. Reassemble the parts following the above procedure in
the reverse order.
4. Once this procedure is nished, replace the old rating
sticker with one indicating the new type of gas used.
Sticker are available from any of our Service Centres.
Replacing the nozzles on separate “double ame
burners
1. Remove the grids and slide the burners from their
housings. The burner consists of 2 separate parts (see
gure);
2. Unscrew the burers with a 7 mm wrench spanner. The
internal burner has a nozzle, the external burner has
two (of the same size). Replace the nozzle with models
suited to the new type of gas (see table 1).
3. Replace all the components by repeating the steps in
reverse order.
AUS
9
Replacing the Triple ring burner nozzles
1. Remove the pan supports and lift the burners out of their
housing. The burner consists of two separate parts (see
pictures).
2. Unscrew the nozzles using a 7 mm socket spanner.
Replace the nozzles with models that are congured
for use with the new type of gas (see Table 1). The two
nozzles have the same hole diameter.
3. Replace all the components by completing the above
operations in reverse order.
Adjusting the burners’ primary air :
Does not require adjusting.
Setting the burners to minimum:
1. Turn the tap to the low ame position;
2. Remove the knob and adjust the adjustment screw, which
is positioned in or next to the tap pin, until the ame is
small but steady.
! In the event of single-control DRDA (DCDR) burners,
adjustment can be performed by intervening on the 2 screws
located near the tap pin (see picture).
Inner DRDA (DCDR)
burner adjustment
Total DRDA
(DCDR) burner
adjustment
3. Having adjusted the ame to the required low setting,
while the burner is alight, quickly change the position
of the knob from minimum to maximum and vice versa
several times, checking that the ame does not go out.
4. Some appliances have a safety device (thermocouple)
tted. If the device fails to work when the burners are set
to the low ame setting, increase this low ame setting
using the adjusting screw.
5. Once the adjustment has been made, replace the
seals on the by-passes using sealing wax or a similar
substance.
! If the appliance is connected to liquid gas, the regulation
screw must be fastened as tightly as possible.
! Once this procedure is nished, replace the old rating
sticker with one indicating the new type of gas used. Stickers
are available from any of our Service Centres.
! Should the gas pressure used be different (or vary slightly)
from the recommended pressure, a suitable pressure
regulator must be tted to the inlet pipe (in order to comply
with current national regulations).
Post Installation Checks
Perform post installation checks and ensure proper and
safe operation before leaving. Test all burners individually
and in combination.
Leak Check
Ensure all gas control knobs are in the Off position.
Ensure the gas supply is switched on.
Spray a solution of soapy water onto all gas joints
as well as the full length of any flexible hoses.
UNDER NO CIRCUMSTANCES USE A NAKED FLAME
IN CHECKING FOR LEAKS.
If bubbles appear anywhere, turn the gas supply off, check
all connections and retest. If satisfactory operation cannot
be achieved, contact place of purchase or their appointed
agent for service.
Flame check
Turn each burner on, and ensure that the ame is blue with
minimal yellow tipping. If there is signicant yellow tipping,
ame lift off or excessive noise, check pressure and adjust
at the regulator if necessary.
If satisfactory operation cannot be achieved, contact place
of purchase or their appointed agent for service.
Igniter operation
Check that the igniter for each burner successfully ignites
the gas.
If an igniter fails to work, rst remove the plug from the
electrical power outlet, and then check that all the electrical
connections are in place.
If satisfactory operation cannot be achieved, contact place
of purchase or their appointed agent for service.
Low ame setting
Check the low ame setting for each hob burner to ensure
that the minimum ame will not be extinguished by air
draughts.
Light the burner.
Turn the control until it engages in the minimum position.
Ensure the ame is stable and will not be extinguished
by air draughts.
To adjust the minimum ame:
Follow the procedure described in the gas conversion
instruction.
DO NOT MODIFY THIS APPLIANCE IN ANY WAY, OTHER
THAN AS DESCRIBED IN THESE INSTRUCTIONS.
10
AUS
Burner and nozzle specifications
Gas Connection
Natural Gas (1.0 kPa)
ULPG (2.75 kPa)
Auxiliary Burner
Semi Rapid Burner
Rapid Burner
Dual Control Wok Burner
Total
Ø Injector (mm)
GC (MJ/hr)
Ø Injector (mm)
GC (MJ/hr)
Gas Inlet fitting 1/2” BSP (male) thread
Location of gas inlet40 mm from rear edge
40 mm from right hand edge
0.85
1.10
1.24
0.80 + 1.19 + 1.19
3.6
6.0
7.8
17.0
34.4
0.50
0.64
0.80
0.50 + 0.70 + 0.70
3.3
5.5
9.0
16.5
34.3
PK 640 R GH AUS
R
DC
S
A
Burner and nozzle specifications
Gas Connection
Natural Gas (1.0 kPa)
ULPG (2.75 kPa)
Auxiliary Burner
Semi Rapid Burner
Wok Burner
Dual Control Wok Burner
Total
Ø Injector (mm)
GC (MJ/hr)
Ø Injector (mm)
GC (MJ/hr)
Gas Inlet fitting 1/2” BSP (male) thread
Location of gas inlet40 mm from rear edge
40 mm from right hand edge
0.85
1.10
1.19 (x2)
0.80 + 1.19 + 1.19
3.6
6.0
13.5
17.0
40.1
0.50
0.64
0.70 (x2)
0.50 + 0.70 + 0.70
3.3
5.5
13.0
16.5
38.3
PK 750 RT GH AUS
DC TC
S
A
! The product was tested in accordance with AS4551 standard
AUS
11
Start-up and use
! The position of the corresponding gas burner or electric
hotplate* is shown on every knob.
Gas cooker hobs are equipped with discrete power
adjustment that allows for accurately adjusting the ame to 5
different power levels. Thanks to this system, gas hobs are
also capable of guaranteeing the same cooking results for
each recipe, as the optimal power level for the desired type
of cooking can be identied in an easier, more accurate way.
Gas burners
Each burner can be adjusted to one of the following settings
using the corresponding control knob:
Off
Maximum
Minimum
To light one of the burners, hold a lit match or lighter near
the burner and, at the same time, press down and turn the
corresponding knob anti-clockwise to the maximum setting.
Since the burner is tted with a safety device, the knob
should be pressed for approximately 2-3 seconds to allow
the automatic device keeping the ame alight to heat up.
When using models with an ignition button, light the desired
burner pressing down the corresponding knob as far as possible
and turning it anticlockwise towards the maximum setting.
! If a ame is accidentally extinguished, turn off the control
knob and wait for at least 1 minute before trying to relight it.
To switch off the burner, turn the knob in a clockwise
direction until it stops (when reaches the “●” position).
Discrete ame adjustment
The selected burner can be adjusted - by means of the knob
- to 5 different power levels. To shift between levels, simply
turn the knob towards the desired power level.
A click signals the passage from one power level to the other.
The selected power level is
indicated by the corresponding
symbol (symbols ) and,
on hobs equipped with a display,
by the LEDs that turn on (5 =
max. power; 1 = min. power). The
system guarantees accurate ame
adjustment and uniform cooking
results by facilitating selection of the desired power level.
The “double-ame” burner
This gas burner consists of two concentric ame rings that can
operate jointly or independently (in case of dual-control only).
As the burner is tted with a safety device, the knob
should be pressed down for approximately 2-3 seconds until
the device keeping the ame automatically alight heats up.
Dual control:
Each ring comprising the burner has its own control knob:
The knob marked with the symbol controls the outer ring.
The knob marked with the symbol controls the inner ring.
To activate any one of the two rings, press the corresponding
knob and turn it anti-clockwise to the maximum power
setting .
In order to use the double-flame burner to its full
potential, avoid simultaneously setting the inner ring to
minimum power and the outer ring to maximum power.
Single control:
The rings comprising the burner are activated through a
single control knob.
To simultaneously turn on both rings, position the knob on
the symbol (max) - (min) then press and turn the
knob anti-clockwise.
To turn on the inner ring only, position the knob on the symbol
(max ) - (min) then press and turn the knob clockwise.
(to switch modes, it is necessary to switch off the burner).
To switch off the burner, press and turn the knob clockwise
until it stops (when it reaches the “●” position).
Practical advice on using the burners
To ensure the burners operate efciently:
Use appropriate cookware for each burner (see table)
so that the ames do not extend beyond the bottom of
the cookware.
Always use cookware with a at base and a cover.
When the contents of the pan reach boiling point, turn
the knob to minimum.
Burner
Semi-Rapid (S)
Auxiliary (A)
Triple Crown (TC)
Double Flame (DCDR internal)
Double Flame (DCDR external)
Ø Cookware Diameter (cm)
16 - 20
10 - 14
24 - 26
10 - 14
26 - 28
Pans to be used on 75 cm hob
s
Burner
Rapid (R)
Semi-Rapid (S)
Auxiliary (A)
Double Flame (DCDR internal)
Double Flame (DCDR external)
Ø Cookware Diameter (cm)
24 - 26
16 - 20
10 - 14
10 - 14
24 - 26
Pans to be used on 60 cm hobs
! On the models supplied with a reducer shelf, remember
that this should be used only for the Double ame internal
12
AUS
(DCDR internal) burner when you use casserole dishes with
a diameter under 12 cm.
To identify the type of burner, refer to the designs in the
section entitled, “Burner and Nozzle Specications”.
Precautions and tips
! This appliance has been designed and manufactured
in compliance with international safety standards. The
following warnings are provided for safety reasons and
must be read carefully.
General safety
This is a class 3 built-in appliance.
Gas appliances require regular air exchange to
maintain efcient operation. When installing the hob,
follow the instructions provided in the paragraph on
“Positioning” the appliance.
These instructions are only valid for the countries
whose symbols appear in the manual and on the
serial number plate.
The appliance was designed for domestic use inside the
home and is not intended for commercial or industrial use.
The appliance must not be installed outdoors, even in
covered areas. It is extremely dangerous to leave the
appliance exposed to rain and storms.
Do not touch the appliance with bare feet or with wet or
damp hands and feet.
The appliance must be used by adults only for the
preparation of food, in accordance with the instructions
outlined in this booklet. Any other use of the appliance
(e.g. for heating the room) constitutes improper use and
is dangerous. The manufacturer may not be held liable
for any damage resulting from improper, incorrect and
unreasonable use of the appliance.
The openings used for ventilation and dispersion of heat
must never be covered.
Always make sure the knobs are in the “●”/“” position
when the appliance is not in use.
When unplugging the appliance always pull the plug from
the mains socket, do not pull on the cable.
Never carry out any cleaning or maintenance work
without having detached the plug from the mains.
In case of malfunction, under no circumstances should
you attempt to repair the appliance yourself. Repairs
carried out by inexperienced persons may cause injury
or further malfunctioning of the appliance. Contact a
Service Centre (see Assistance).
Always make sure that pan handles are turned towards
the centre of the hob in order to avoid accidental burns.
Do not close the glass cover (if present) when the gas
burners or electric hotplates are still hot.
Do not leave the electric hotplate switched on without a
pan placed on it.
Do not use unstable or deformed pans.
The appliance should not be operated by people
(including children) with reduced physical, sensory or
mental capacities, by inexperienced individuals or by
anyone who is not familiar with the product. These
individuals should, at the very least, be supervised by
someone who assumes responsibility for their safety or
receive preliminary instructions relating to the operation
of the appliance.
Do not let children play with the appliance.
The appliance is not intended to be operated by
means of an external timer or separate remote-
control system.
Safety warnings:
Do not use or store flammable materials near this
appliance.
Do not spray aerosols in the vicinity of this appliance
while it is in operation.
Do not modify this appliance.
Not siutable for operation with aftermarket lids or cover
tted.
Where this appliance is installed in marine craft or in
caravans it shall not be used as a space heater.
Disposal
When disposing of packaging material: observe local
legislation so that the packaging may be reused.
The European Directive 2002/96/EC on Waste
Electrical and Electronic Equipment (WEEE), requires
that old household electrical appliances must not
be disposed of in the normal unsorted municipal
waste stream. Old appliances must be collected
separately in order to optimise the recovery and
recycling of the materials they contain and reduce
the impact on human health and the environment.
The crossed out “wheeled bin” symbol on the product
reminds you of your obligation, that when you dispose
of the appliance it must be separately collected.
Consumers should contact their local authority or retailer
for information concerning the correct disposal of their
old appliance.
Maintenance and care
Switching the appliance off
Disconnect your appliance from the electricity supply before
carrying out any work on it.
Cleaning the appliance
! Do not use abrasive or corrosive detergents such as stain
removers, anti-rust products, powder detergents or sponges with
abrasive surfaces: these may scratch the surface beyond repair.
! Never use steam cleaners or pressure cleaners on the
appliance.
• It is usually enough to wash the hob with a damp sponge
and dry it with absorbent kitchen roll.
The removable parts of the burners should be washed
frequently with warm water and soap and any burnt-on
substances removed.
For hobs which ligth automatically, the terminal part of
the electronic instant lighting devices should be cleaned
frequently and the gas outlet holes should be checked
for blockages.
Stainless steel can be marked by hard water that has
been left on the surface for a long time, or by aggressive
AUS
13
detergents containing phosphorus. After cleaning, rinse
and dry any remaining drops of water.
! It is not necessary to remove the pan supports in order to
clean the hob surface. Thanks to the support system, simply
lift and hold the pan supports or rotate them until they rest
against a rear support.
Do not place the hot grids on top of the glass cover (if
applicable), otherwise the rubber plugs on the glass
may be damaged.
Gas tap maintenance
Over time, the taps may become jammed or difcult to turn.
If this happens, the tap must be replaced.
! This procedure must be performed by a qualied
technician authorised by the manufacturer.
Troubleshooting
It may happen that the appliance does not function properly
or at all. Before calling the service centre for assistance,
check if anything can be done. First, check to see that there
are no interruptions in the gas and electrical supplies, and,
in particular, that the gas valves for the mains are open.
The burner does not light or the ame is not even
around the burner.
Check whether:
The gas holes on the burner are clogged.
All the movable parts that make up the burner are
mounted correctly.
There are draughts near the appliance.
The ame dies in models with a safety device.
Check to make sure that:
You pressed the knob all the way in.
You keep the knob pressed in long enough to activate
the safety device.
The gas holes are not blocked in the area corresponding
to the safety device.
The burner does not remain lit when set to minimum.
Check to make sure that:
The gas holes are not blocked.
There are no draughts near the appliance.
The minimum setting has been adjusted properly.
The cookware is unstable.
Check to make sure that:
The bottom of the cookware is perfectly at.
The cookware is positioned correctly at the centre of the
burner.
The pan support grids have been positioned correctly.
14
AUS
15
FR
Installation
! Avant d’utiliser votre nouvel appareil, veuillez lire cette
notice avec la plus grande attention. Elle contient des
informations importantes destinées à assurer votre sécurité
lors de l’utilisation, l’installation et l’entretien de l’appareil.
! Veuillez conserver cette notice an de pouvoir la consulter
ultérieurement. En cas de cession de l’appareil à un tiers,
veuillez également lui transmettre cette notice.
Conformité aux normes en vigueur
Cette table de cuisson doit être installée conformément aux
règles dénies par les autorités locales de gaz et d’électricité
et aux dernières versions publiées des normes suivantes :
AS/NZS 5601 Code relatif à l’installation d’appareils à
gaz
Règles de câblage de la SAA
Positionnement
! Conservez les matériaux d’emballage hors de portée des
enfants. Ils peuvent représenter un danger d’étouffement
(voir Précautions et conseils).
! L’appareil doit être installé par un professionnel qualié
conformément aux instructions fournies. Une installation
incorrecte peut être à l’origine de blessures pour les
personnes et les animaux ou de dommages matériels.
Ventilation de la cuisine
Si la consommation totale de tous les appareils dépasse
les 3 MJ/h par mètre cube de la pièce ou du volume de
l’enceinte, l’espace doit être ventilé par l’une des méthodes
décrites en détails ci-dessous. Le critère “ volume de la
pièce “ pris en compte pour déterminer si la ventilation est
adéquate ou non correspond à l’espace ne pouvant pas
être isolé par des portes.
Ventilation naturelle directe venant de l’extérieur
Deux ouvertures permanentes vers l’extérieur doivent être
ménagées. Les ouvertures doivent être placées de manière
à assurer que la distance entre le haut de l’ouverture
supérieur et le plafond de la pièce ou de l’enceinte, et la
distance entre le bas de l’ouverture inférieure et le sol de la
pièce ou de l’enceinte ne dépassent pas 5 % de la hauteur
de la pièce ou de l’enceinte. La surface de ventilation libre
minimale fournie par chaque ouverture sera calculée en
utilisant la formule suivante :
A = 3 × T
A = la surface de ventilation libre minimale (cm2)
T = la consommation totale de gaz de tous les appareils
(MJ/h)
La dimension verticale minimale de toute ouverture de
ventilation libre doit être de 6 mm.
NOTE 1 Lorsqu’elle est utilisée ici, l’expression “ directement
vers l’extérieur signie l’une des options ci-dessous, à
condition que le chemin de ventilation ne soit pas obstrué
par des matériaux de construction ou d’isolation :
(a) Directement à travers un mur extérieur (option
préférée).
(b) À travers un mur extérieur mais avec un décalage.
(c) Dans une cavité ventilée vers l’extérieur.
(d) Dans un espace situé sous le sol et ventilé vers
l’extérieur.
(e) Dans un espace en toiture ventilé vers l’extérieur.
NOTE 2 Les deux ouvertures peuvent être combinées à
condition que le haut et le bas de l’ouverture atteignent les
limites xées dans cette notice.
Ventilation naturelle par le biais d’une pièce adjacente
Deux ouvertures permanentes doivent être ménagées
dans la pièce ou l’enceinte. Les ouvertures doivent être
placées de manière à assurer que la distance entre le
haut de l’ouverture supérieur et le plafond de la pièce ou
de l’enceinte, et la distance entre le bas de l’ouverture
inférieure et le sol de la pièce ou de l’enceinte ne dépassent
pas 5 % de la hauteur de la pièce ou de l’enceinte.
La surface de ventilation libre minimale fournie par chaque
ouverture sera calculée en utilisant la formule suivante :
A = 6 × T
A = la surface de ventilation libre minimale (cm2)
T = la consommation totale de gaz de tous les appareils
(MJ/h)
Ces exigences s’appliquent à toutes les pièces suivantes,
jusqu’à ce qu’une pièce soit ventilée vers l’extérieur,
conformément à la section précédente, ou si la consommation
totale de tous les appareils ne dépasse pas les 3 MJ/h par
mètre cube du volume total de l’enceinte ou des pièces.
La dimension verticale minimale de toute ouverture de
ventilation libre doit être de 6 mm.
REMARQUE : Les deux ouvertures peuvent être combinées
à condition que le haut et le bas de l’ouverture atteignent
les limites xées dans cette notice.
Les gaz de pétrole liquéés, plus lourds que l’air, se
déposent et stagnent au niveau du sol. Par conséquent,
les pièces contenant des bouteilles de gaz liquéfié
doivent aussi disposer d’ouvertures vers l’extérieur
an de permettre l’évacuation des éventuelles fuites
de gaz. C’est pourquoi les bouteilles de gaz liquéé,
qu’elles soient partiellement ou complètement pleines,
ne doivent pas être installées dans des pièces ou des
espaces de stockage se situant en-dessous du niveau du
sol (par exemple, dans des caves, etc.). Il est conseillée
de ne conserver dans la pièce que la bouteille en cours
d’utilisation et de la placer de telle sorte qu’elle ne
puisse pas être exposée à la chaleur produite par des
sources extérieures (fours, cheminées, poêles, etc.) qui
pourraient faire grimper la température de la bouteille
au-dessus de 50 °C.
Mobilier adjacent
L’emplacement des points de raccordement est indiqué
au tableau situé à la page 5. Pour éviter les problèmes
de fonctionnement des appareils encastrés dans des
meubles, il convient de respecter les distances minimales
représentées sur la gure 4. Il est recommandé que
les surfaces adjacentes de la cuisine soient capables
de résister à des températures de 65°C. Les conditions
suivantes doivent également être respectées :
L’appareil doit être installé à proximité de mobilier dont
la hauteur ne dépasse pas le dessus de la plaque de
cuisson.
16
FR
Le mur en contact direct avec le panneau arrière de
la cuisinière doit être composé d’un matériau non
inammable. Pendant le fonctionnement de la cuisinière,
le panneau arrière de cette dernière peut atteindre une
température de 50 °C supérieure à la température de la
pièce.
Les meubles de cuisine installés à côté de la cuisinière
et qui sont plus hauts que le dessus de la plaque de
cuisson doivent être situés à au moins 600 mm du bord
de la plaque elle-même.
Si la hotte est installée en-dessous d’un élément mural,
ce dernier doit être situé au moins 700 mm (millimètres)
au-dessus de la surface de la plaque.
Les meubles installés à côté de la hotte doit être situé
au moins 420 mm au-dessus de la plaque de cuisson.
Il faut respecter les espacements
minimum suivants par rapport aux
matériaux combustibles :
• L’espacement minimum entre le
bord du brûleur et le mur latéral doit
être de 200 mm.
• L’espacement minimum entre le
bord du brûleur et le mur arrière
doit être de 55 mm.
Hottes
Les hottes et les systèmes de ventilation de plafond
doivent être installés selon les instructions du fabricant
mais l’espacement par rapport aux brûleurs de la plaque
de cuisson ne doit en aucun cas être inférieur à 650 mm
pour les hottes et 750 mm pour les systèmes de ventilation.
Si la hotte est installée en-dessous d’un élément mural,
ce dernier doit être situé au moins 700 mm (millimètres)
au-dessus de la surface de la plaque.
Installation de la table de cuisson au-dessus d’un four
En cas d’installation de la table de cuisson au-dessus d’un
four, il est impératif que ni le câble d’alimentation électrique
ni le tuyau de gaz (exible ou non) ne soient en contact
avec les parties chaudes du four.
En cas d’installation au-dessus four encastré ne disposant
pas de ventilation forcée pour assurer son refroidissement,
il faut créer des ouvertures d’aération an de permettre
une ventilation adéquate à l’intérieur du meuble (au moins
200 cm² en bas pour l’arrivée d’air et au moins 120 cm² en
haut pour la sortie).
Il faut en outre installer une planche de bois sous la plaque
de cuisson en guise d’isolation, à une distance minimale
de 15 mm du meuble.
Avant de procéder à l’installation, enlever les grilles et les
brûleurs du plan de cuisson et renverser celui-ci en veillant
à ce que les thermocouples et les bougies ne soient pas
endommagés.
Appliquer les joints fournis
avec l’appareil sur les bords
extérieurs du plan de cuisson
pour empêcher le passage de
l’air, de l’humidité et de l’eau
(voir gure).
600mm min.
420mm min.
650mm min.
Pour une application correcte, s’assurer que les surfaces
à sceller sont propres, sèches et sans traces de graisses/
huiles.
Le trou réalisé pour y installer la plaque de cuisson doit
avoir les dimensions représentées sur la gure. Des
crochets de xation sont fournis, destinés à xer la
plaque de cuisson sur des plans de travail de 20 à 40
mm d’épaisseur. Pour assurer la bonne xation de la
plaque sur le plan de travail, nous vous recommandons
d’utiliser tous les crochets fournis.
555 mm
55 mm
475 mm
Schéma de xation des crochets
Position du crochet Position du crochet
pour top H=20mm pour top H=30mm
Devant
Position du crochet Derrière
pour top H=40mm
! Utilisez tous les crochets compris dans le “sachet
accessoires”
Si la table n’est pas installée au-dessus d’un four à
encastrer, il faut monter un panneau d’isolation en bois.
Il faut le monter à au moins 20 mm de distance du bord
inférieur de la table.
Aération
Pour garantir une bonne aération, la cavité d’encastrement
doit être dépourvue de paroi arrière. Il est conseillé
d’installer le four de manière à ce qu’il repose sur deux
cales en bois ou bien sur un plan d’appui continu qui ait une
découpe d’au moins 45 x 560 mm (voir gures).
17
FR
560 mm.
45 mm.
Raccordement électrique
Les tables munies d’un cordon d’alimentation tripolaire,
sont prévues pour un fonctionnement à courant alternatif
à la tension et à la fréquence d’alimentation indiquées sur
la plaquette des caractéristiques (placée sous la table de
cuisson). Le conducteur de terre du câble est jaune/vert. En
cas d’installation au-dessus d’un four à encastrer, la connexion
électrique de la table et celle du four doivent être effectuées
séparément, pour des questions de sécurité électrique mais
aussi pour simplier, au besoin, l’extraction du four.
Branchement du câble d’alimentation au réseau électrique
Montez sur le câble une prise normalisée adaptée à la
charge indiquée sur l’étiquette des caractéristiques.
En cas de raccordement direct au réseau, il faut intercaler entre
l’appareil et le réseau un interrupteur à coupure omnipolaire
ayant au moins 3 mm d’écartement entre les contacts,
dimensionné à la charge et conforme aux normes en vigueur
(le l de terre ne doit pas être interrompu par l’interrupteur).
Le câble d’alimentation ne doit atteindre, en aucun point, des
températures dépassant de 50°C la température ambiante.
! L’installateur est responsable du bon raccordement
électrique de l’appareil et du respect des normes de sécurité.
Avant de procéder au branchement, assurez-vous que :
L’appareil est mis à la terre et la che est conforme aux
exigences légales;
La prise de courant peut supporter la puissance maximale
de l’appareil qui est indiquée sur la plaque signalétique;
La tension est située dans la plage de valeurs indiquée
sur la plaque signalétique;
La prise de courant est compatible avec la che de
l’appareil. Si la prise de courant n’est pas compatible
avec la fiche, demandez à un technicien agréé de
la remplacer. N’utilisez pas de rallonges ni de prises
multiples.
! Après installation de l’appareil, le câble électrique et la
prise de courant doivent être facilement accessibles.
! Le câble ne doit être ni plié ni excessivement écrasé.
! Il doit être contrôlé périodiquement et ne peut être
remplacé que par un technicien agréé (voir Assistance).
! Nous déclinons toute responsabilité en cas de non respect
des normes énumérées ci-dessus.
Raccordement gaz
Vériez le type de gaz
! Avant l’installation, vériez que le type de gaz (gaz naturel
ou universel GPL) de la cuisinière est adapté au gaz
disponible dans le lieu d’installation. Il est extrêmement
dangereux d’utiliser le mauvais type de gaz avec quelque
appareil que ce soit. Cela peut entraîner un incendie ou de
blessures graves.
À sa sortie d’usine, cette cuisinière est congurée pour
fonctionner au gaz naturel. Pour utiliser la cuisinière
avec du gaz liquéfié (ou au gaz naturel après l’avoir
utilisée précédemment au gaz liquéé), veuillez suivre les
indications reportées plus loin dans cette section.
Installez le régulateur fourni pour le gaz naturel (le cas
échéant) à l’arrière de l’appareil et le plus près possible
de l’appareil.
Il est recommandé d’installer un robinet et un raccord
d’isolement afin de faciliter la déconnexion pour les
interventions d’entretien. Ces derniers doivent être situés
à un endroit accessible.
! Vérifiez que la pression de l’alimentation en gaz
correspond aux valeurs indiquées dans le Tableau 1 (“
Caractéristiques des brûleurs et des injecteurs “). Cela
garantira le fonctionnement en toute sécurité et la longévité
de votre appareil tout en conservant une bonne efcacité
énergétique.
Raccordement du tuyau ou exible
Cet appareil est adapté pour être utilisé soit avec un raccord
exible soit avec un raccord rigide en cuivre.
Pour effectuer la connexion au raccord à mamelon (raccord
mâle G leté de ½”) situé à l’arrière de l’appareil sur la droite
(gure 8), il faut utiliser soit un tuyau rigide en métal doté de
raccords conformes aux normes en vigueur soit un tuyau
exible de classe B ou D.
Au cas où il serait nécessaire de tourner le raccord, il faudra
remplacer le joint d’étanchéité (fourni avec l’appareil).
Si un tuyau exible est utilisé, il devra être le plus court
possible, avec une longueur maximale de 1,5 mètres ;
le raccord du exible doit être conforme au minimum à
la classe B ou D de la réglementation AS/NZS1869.
il ne doit être ni plié, ni entortillé ni comprimé ;
il ne doit pas être en contact avec la paroi arrière de
l’appareil ou, dans tous les cas, avec des pièces pouvant
atteindre une température de 50 °C ;
il ne doit pas entrer en contact avec des éléments pointus
ou des angles tranchants ;
il ne doit pas être soumis à des forces de traction ou de
torsion ;
il doit être facile à inspecter sur toute sa longueur an
de pouvoir contrôler son état.
Le point de connexion à l’alimentation doit être accessible
une fois l’appareil installé.
Le diamètre intérieur du tuyau doit respecter les
conditions suivantes :
8 mm pour le gaz liquéé ;
13 mm pour le gaz naturel.
Vérication de l’étanchéité du raccord
Une fois l’installation terminée, vériez le circuit de gaz, les
connexions internes et les robinets en utilisant une solution
savonneuse (jamais une amme). Vériez également que
le tuyau de raccordement ne peut pas entrer en contact
avec des parties mobiles qui pourraient l’endommager ou
l’écraser. Assurez-vous que le tuyau de gaz naturel est
adapté pour une alimentation en gaz sufsante lorsque
tous les brûleurs sont allumés.
18
FR
Copie de la plaque signalétique
Si la plaque signalétique se trouve cachée par le mobilier
lorsque la cuisinière est en place, placez une copie de la
plaque signalétique sur une surface du mobilier situé à côté
de la cuisinière.
Adaptation aux différents types de gaz
Pour adapter l’appareil à un type de gaz autre que le gaz par
défaut (indiqué sur la plaque signalétique située à la base
de la plaque de cuisson ou sur l’emballage), remplacez les
injecteurs de tous les brûleurs en procédant comme suit :
1. Enlevez les grilles du plan de cuisson et sortez les
brûleurs de leur logement.
2. Dévissez les injecteurs à l’aide d’une clé à douille de
7 mm et remplacez-les par les injecteurs adaptés au
nouveau type de gaz (voir tableau 1 “ Caractéristiques
des brûleurs et des injecteurs “).
3. Remontez les différentes parties en effectuant la
procédure ci-dessus en sens inverse.
4. Une fois cette procédure terminée, remplacez l’ancienne
étiquette par une étiquette indiquant le nouveau gaz
utilisé. Vous pouvez vous procurer cette étiquette auprès
de n’importe lequel de nos Services d’assistance.
Remplacement des injecteurs sur le brûleur “deux
ammes” indépendantes
1. Enlevez les grilles du plan de cuisson et sortez les
brûleurs de leur logement ; Le brûleur est formé de deux
parties distinctes (voir gure) ;
2. Dévissez les injecteurs à l’aide d’une clef en tube de
7 mm. Le brûleur intérieur a un injecteur, le brûleur
extérieur en a deux (de même dimension). Remplacez
les injecteurs par d’autres appropriés au nouveau type
de gaz (voir tableau 1).
3. Remontez les différentes parties en effectuant les
opérations dans le sens inverse.
Remplacement des injecteurs du brûleur à triple
couronne
1. Retirez les supports pour casseroles et soulevez les
brûleurs hors de leur logement. Le brûleur est composé
de deux parties distinctes (voir gures).
2. Dévissez les injecteurs à l’aide d’une clé à douille
de 7 mm. Remplacez les injecteurs par des modèles
d’injecteurs adaptés pour le nouveau type de gaz (voir
Tableau 1). Les deux injecteurs ont le même diamètre
d’orice.
3. Remettez tous les composants en place en répétant les
opérations ci-dessus dans le sens inverse.
Réglage de l’air primaire des brûleurs :
Ne nécessite pas de réglage.
Réglage des brûleurs au minimum :
1. Tournez le robinet dans la position de minimum.
2. Retirez le bouton et ajustez la vis de réglage qui se situe
dans ou à côté de la tige du robinet, jusqu’à ce que la
amme soit petite mais régulière.
! Dans le cas du brûleur DCDR mono commande, effectuer
le réglage au moyen des 2 vis situées à côté de la tige du
robinet (voir gure).
Réglage
DCDR intérieur
Réglage
DCDR total
3. Une fois obtenu le débit minimal souhaité, allumez le
brûleur et tournez brusquement le bouton de la position
de minimum à la position de maximum et vice versa à
plusieurs reprises, en vériant que la amme ne s’éteint
pas.
4. Certains appareils sont équipés d’un système de sécurité
(thermocouple). Si l’appareil ne fonctionne pas lorsque
les brûleurs sont réglés sur la position de minimum,
augmentez le réglage du minimum à l’aide de la vis de
réglage.
5. Après avoir procédé à ce réglage, reposez les scellés
sur les by-pass en utilisant de la cire ou une substance
équivalente.
! Si l’appareil est raccordé à une bouteille de gaz liquide,
la vis de réglage doit être serrée au maximum.
! Une fois cette procédure terminée, remplacez l’ancienne
étiquette par une étiquette indiquant le nouveau gaz utilisé.
Vous pouvez vous procurer cette étiquette auprès de
n’importe lequel de nos Services d’assistance.
! Au cas où la pression de gaz utilisée serait différente
(ou seulement légèrement différente) de la pression
recommandée, il faut installer un régulateur de pression
adapté sur le tuyau d’arrivée de gaz (afin d’être en
conformité avec les réglementations nationales en vigueur).
19
FR
Vérications après installation
Effectuez des vérications après installation et assurez-
vous que l’appareil fonctionne correctement et en toute
sécurité avant de vous en éloigner. Testez tous les brûleurs
individuellement et l’un après l’autre.
Vérication de la présente de fuite
Veillez à ce que tous les boutons de commande de gaz
soient dans la position éteinte.
Veillez à ce que l’alimentation en gaz soit ouverte.
Vaporisez une solution d’eau savonneuse sur
tous les raccords de l’alimentation en gaz ainsi
que sur toute la longueur des tuyaux flexibles.
VOUS NE DEVEZ EN AUCUN CAS UTILISER UNE
FLAMME NUE AFIN DE DÉTECTER L’ÉVENTUELLE
PRÉSENCE DE FUITES DE GAZ.
Si des bulles apparaissent à un endroit ou un autre, coupez
l’alimentation en gaz, vériez tous les raccords et refaites
un test. Si vous ne parvenez pas à un fonctionnement
satisfaisant, contactez votre lieu d’achat ou leur technicien
d’entretien agréé.
Vérication de la amme
Allumez chaque brûleur et vériez que la amme est bleue
avec le moins de jaune possible. S’il y a beaucoup de
jaune, si la amme s’éteint ou bien si la combustion est
excessivement bruyante, vériez la pression et ajustez-la
au niveau du régulateur si cela s’avère nécessaire.
Si vous ne parvenez pas à un fonctionnement satisfaisant,
contactez votre lieu d’achat ou leur technicien d’entretien
agréé.
Fonctionnement de l’allumeur
Vérifiez que l’allumeur de chaque brûleur parvient à
enammer correctement le gaz.
Si un allumeur ne fonctionne pas, débranchez d’abord la
che de la prise de courant puis vériez que toutes les
connexions électriques sont correctes.
Si vous ne parvenez pas à un fonctionnement satisfaisant,
contactez votre lieu d’achat ou leur technicien d’entretien
agréé.
Réglage du minimum
Vériez le réglage du minimum pour chaque brûleur de
la plaque de cuisson an de vous assurer que la amme
minimale ne risque pas d’être éteinte par les courants d’air.
Allumez le brûleur.
Tournez le bouton jusqu’à la position de minimum.
Assurez-vous que la amme est stable et ne s’éteindra
pas au moindre courant d’air.
Pour ajuster la amme minimale :
Suivez la procédure décrite dans les instructions relatives
au changement de gaz utilisé.
NE MODIFIEZ EN AUCUN CAS CET APPAREIL SI CE
N’EST TEL QUE DÉCRIT DANS CETTE NOTICE.
20
FR
Caractéristiques des brûleurs et des injecteurs
Raccordement gaz
Gaz naturel (1,0 kPa)
Gaz liquéfié (2,75 kPa)
Brûleur auxiliaire
Brûleur semi-rapide
Brûleur rapide
Double flamme
Total
Diamètre des
injecteurs (mm)
Consommation de gaz
(MJ/hr)
Raccord d'arrivée de gaz
0.85
1.10
1.24
0.80 + 1.19 + 1.19
3.6
6.0
7.8
17.0
34.4
0.50
0.64
0.80
0.50 + 0.70 + 0.70
3.3
5.5
9.0
16.5
34.3
Diamètre des
injecteurs (mm)
Consommation de gaz
(MJ/hr)
Emplacement de
l'arrivée de gaz
Filetage (mâle) BSP de 1/2”
40 mm du bord arrière
40 mm du bord latéral
PK 640 R GH AUS
R
DC
S
A
Caractéristiques des brûleurs et des injecteurs
Raccordement gaz
Gaz naturel (1,0 kPa)
Gaz liquéfié (2,75 kPa)
0.85
1.10
1.19 (x2)
0.80 + 1.19 + 1.19
3.6
6.0
13.5
17.0
40.1
0.50
0.64
0.70 (x2)
0.50 + 0.70 + 0.70
3.3
5.5
13.0
16.5
38.3
Diamètre des
injecteurs (mm)
Diamètre des
injecteurs (mm)
Consommation de gaz
(MJ/hr)
Consommation de gaz
(MJ/hr)
Brûleur auxiliaire
Brûleur semi-rapide
Brûleur wok à triple couronne
Double flamme
Total
Raccord d'arrivée de gaz
Emplacement de
l'arrivée de gaz
Filetage (mâle) BSP de 1/2”
40 mm du bord arrière
40 mm du bord latéral
PK 750 RT GH AUS
DC TC
S
A
! Le produit a été testé conforme à la norme AS4551
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Whirlpool PK 750 RT GH AUS Mode d'emploi

Catégorie
Plaques de cuisson
Taper
Mode d'emploi
Ce manuel convient également à