GE ZDIC150WBB Guide d'installation

Catégorie
Fabricants de glaçons
Taper
Guide d'installation

Ce manuel convient également à

Installation
Instructions
Automatic Ice maker
ZDIC150
ZDIS150
Design Guide
With Installation Instructions
monogram.com
Installation Instructions
BEFORE YOU BEGIN:
Read these instructions completely and carefully.
IMPORTANT:
Save these instructions for local inspector’s use.
IMPORTANT:
Observe all governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions with
your Owner’s Manual for future reference.
WARNING:
This appliance must be properly grounded.
Failure to do so can result in death, fire or electrical
shock. See “Power Supply,” page 6.
AVERTISSEMENT :
Cet appareil doit être correctement mis à la terre.
Le non-respect de ces instructions peut causer la
mort, un incendie ou un choc électrique. Consulter «
Alimentation électrique », page 6.
If you received a damaged ice maker, you should
immediately contact your dealer or builder.
Proper installation is the responsibility of the
installer. Product failure due to improper installation
is not covered under the GE Appliance Warranty.
See the Owner’s Manual for warranty information.
Use this appliance only for its intended purpose.
Check with local utilities for electrical codes that
apply in your area. Local codes vary. Installation,
electrical connections and grounding must comply
with applicable codes. In the absence of local codes,
the ice maker should be installed in accordance
with National Electrical Code ANSI/NFPA 70-1990 or
latest edition.
For Monogram local service in your area, call
1.800.444.1845.
For Monogram Service in Canada, call
1.800.561.3344.
For Monogram Parts and Accessories, call
1.800.626.2002.
2
CONTENTS
Design Information
Models Available ....................................................................3
Optional Accessories ...........................................................3
Tools and Materials Required ........................................ 3
Cutout & Product Dimensions .........................................4
Installation
Advance Planning .................................................................4
Water Supply ...........................................................................5
Power Supply ...........................................................................6
Remove Packaging ...............................................................6
Water Filtration System .................................................6, 7
Adjust Height of Ice maker ...............................................7
Connect the Drain .................................................................9
Connect Water Supply to Appliance ............................9
Reverse Door Swing ...................................................10, 11
Accessories
ZPK2 Auxiliary Pump Kit ............................................12-15
ZIP75BB Kit for 3/4” thick panels ..........................16, 17
Design Information
MODELS AVAILABLE
ZDIC150ZBB, ZDIS150ZSS
Available in black and stainless steel.
The ice maker may be installed below a countertop
or used free-standing.
3
OPTIONAL ACCESSORIES
=,3%%³For the installation of a trimless
3/4” thick custom panel on black models (not for
stainless steel models). This kit provides a handle
that can be installed with the custom panel.
A custom handle of your choice may be installed onto
the 3/4” panel. See installation instructions
on pages 10 and 11.
ZPK2 Drain Pump Kit - For use when a floor drain is
not available. The drain pump must be installed
inside the unit and can pump discharge water at a
maximum vertical height of 10 feet. 10 feet of tubing
is supplied with the kit.
TOOLS AND MATERIALS REQUIRED FOR BASIC INSTALLATION
1/4” socket
3/4” adjustable wrench
Level
GE SmartConnect
Refrigerator Tubing Kit or 1/4” O.D.
copper tubing, of sufficient length to reach the installation
Flat-blade screwdriver
7/16” and 1/2” open-end wrenches or 2 adjustable wrenches
1/4” nut driver
Installation Instructions
4
CABINET
CABINET
120°
110°
3/4”
Custom Panel Installation, Top View
Corner Installation
1-1/2”-wide filler
panel or cleat set
back even with
front of case.
CABINET
CABINET
1/2”-wide filler
panel or cleat set
back even with
front of case.
120°
110°
Flush Installation, Top View
ADVANCE PLANNING
CAUTION: Due to excessive weight, TWO
PEOPLE ARE REQUIRED TO MOVE AND INSTALL THIS
Ice maker. Failure to do so can result in back or other
injury.
MISE EN GARDE :
A cause de son poids élevé, IL FAUT DEUX
PERSONNES POUR DÉPLACER ET INSTALLER CETTE
MACHINE À GLAÇONS. Le non-respect de ces
instructions peut causer des blessures au dos ou
d’autre nature.
* For flush installation of ZDIS150 and ZDIC150 models: Install
a 1/2”-wide filler strip on the hinge side. The filler strip will act
as a spacer between the door case and adjacent cabinets and
will prevent interference with the cabinet door swing. Recess
the filler strip 1” back from the front face of the ice maker, or
even with the front edge of the product case. The width of the
opening must be 15-1/2” (including the 1/2” filler strip).
** The black model ZDIC150 with a custom panel cannot
be installed flush. A 1-1/2”-wide filler strip is required on the
hinge side. The ice maker will project forward 3/4” of adjacent
cabinets. Recess the filler strip 1-3/4” back from the front face
of the ice maker or even with the front edge of the product
case. The width of the opening must be 16-1/2” wide, including
the 1-1/2” filler strip.
CUTOUT & PRODUCT DIMENSIONS
CUTOUT & PRODUCT DIMENSIONS (Cont.)
Cutout dimensions shown allow for a full door swing.
Installation Instructions
ADVANCE PLANNING (cont.)
LOCATION REQUIREMENTS:
Not designed for outdoor installation.
The ice maker must be installed in an area
protected from elements such as wind, rain, water
spray or drip. The area should be ven ti lat ed with
temperatures above 55°F (13°C) and below 110°F
(43°C). Best results are obtained between 70°F (21°C)
and 90°F (32°C).
The ice maker may be closed in on the top and
three sides as long as the front is un ob struct ed
for air circulation and proper op er a tion.
Installation should be such that the ice maker
can be moved forward for ser vic ing, if necessary.
The bottom grille on the front must be
unobstructed to provide proper air flow.
WATER SUPPLY
A cold water supply with water pressure of between
30 and 120 psi is required to operate the ice maker.
If you have questions about your water pressure, call
a licensed, qualified plumber.
ELECTRICAL REQUIREMENTS
WARNING : (Please read carefully).
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED. Do not remove ground
plug. Do not use an adapter. Do not use an
extension cord. Failure to follow these instructions
can result in death, fire or electrical shock.
AVERTISSEMENT :
(S’il vous lisez avec soin). POUR VOTRE SÉCURITÉ,
CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À
LA TERRE. N’enlevez pas la fiche de mise à la terre.
N’utilisez pas un adaptateur. N’utilisez pas un
cordon de rallonge. L’omission d’observer ces
directives peut entraîner la mort, l’incendie ou
l’électrocution.
Before you move your ice maker into its final
location, it is important to make sure you have the
proper electrical connection:
A 115 volt, 60 Hz., AC only, 15- or 20-amp electrical
supply, properly grounded in accordance with
the National Electrical Code and local codes and
ordinances, is required. Use an outlet which cannot
be turned off by a switch or pull chain.
5
ADVANCE PLANNING (cont.)
IMPORTANT: This unit must NOT be on a GFCI
(Ground Fault Circuit Interrupter) equipped outlet
or nuisance tripping may occur resulting in loss of
cooling. Ice quality may be affected. If nuisance
tripping has occurred, and if the condition of the ice
appears poor, dispose of the ice.
Recommended Grounding Method
The ice maker must be grounded. The ice maker
is equipped with a power supply cord having a 3
prong grounding plug. The cord must be plugged
into a mating, 3 prong, grounding-type wall outlet,
grounded in accordance with the National Electrical
Code and local codes and ordinances. If a mating
wall receptacle is not available, one must be installed
by a qualified electrician.
DRAINING REQUIREMENTS
Determine a method of drainage. If a floor drain
is to be installed, the drain must be accurately
located. The installation of a custom door panel will
affect the drain location. See page 7 to determine the
exact location of the floor drain, front to back, with or
without a custom door panel.
A drain pump kit, ZPK2, is available and will not
interfere with placement of the ice maker.
BEFORE YOU BEGIN:
1. If a custom panel is to be installed, follow the
instructions shown on pages 10 and 11.
–Order ZIP75 (black) panel kit.
Order the custom panel from the cabinet
manufacturer.
–Secure the custom panel onto the ice maker.
2. The door swing is reversible. If desired, change
the door swing before installation following
instructions on page 13.
3. Slide the ice maker into the installation location.
Open and close the door to be sure there is no
interference.
Check to be sure the ice maker can be moved
back into the opening, flush with adjacent
cabinetry. There should be no interference with
the floor drain.
Check to be sure the ice maker is level. The ice
maker will not operate properly if it is not level.
See page 6.
Installation Instructions
REMOVE PACKAGING AND PARTS
Lay the carton on rear
face and break open the
bottom flap.
Set the carton upright
with all four bottom flaps
outward.
Lift carton up and off ice
maker.
Remove all tape and
packaging material from the outside and inside
of the cabinet.
WATER FILTRATION SYSTEM
Install Water Filter
1. Locate the accessory packet in the ice maker and
remove the water filter.
2. Remove the cover from the water filter. Be sure the
O-rings are still in place after the cover is removed.
3. Locate the water filter compartment on the right-
hand side of the ice maker controls.
4. Align the alignment pin on the side of the filter
with the cutout channel in the control housing and
insert filter.
5. Turn filter clockwise until it locks into the housing.
NOTE: If the filter is not correctly locked into place,
the ice maker will not produce ice.
POWER SUPPLY
WARNING : (Please read carefully).
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED. Failure to follow these
instructions can result in death, fire or electrical
shock.
AVERTISSEMENT :
(S’il vous lisez avec soin). POUR VOTRE SÉCURITÉ,
CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À
LA TERRE. Le non-respect de ces instructions peut
causer la mort, un incendie ou un choc électrique.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Code or
prevailing local codes and or di nanc es.
This ice maker must be supplied with 115V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp
circuit breaker or time delay fuse.
A properly grounded three-prong outlet should be
located within reach of the ice maker’s 66” long
power cord. For a built-in installation, locate the
receptacle in the shaded area shown.
IMPORTANT: (Please read carefully).
The power cord of this appliance
is equipped with a three-prong
(ground ing) plug that mates with a
standard three-prong grounding wall
re cep ta cle to minimize the possibility
of electric shock. The customer
should have the wall receptacle and circuit checked
by a qualified electrician to make sure the re cep ta cle
is properly ground ed and has the correct polarity.
Where a standard two-prong wall receptacle is
encountered, it is the personal re spon si bil i ty and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
DO NOT USE AN EXTENSION CORD.
6
Cover
O-Rings
Alignment Pin
Alignment
Arrow
Unlock symbol
Alignment Pin
Lock symbol
Cutout channel in
control housing
Installation Instructions
ADJUST HEIGHT AND LEVEL THE
ICE MAKER
Height adjustments may be necessary to install
the ice maker below a countertop, and may be
accomplished by adjusting both the front and rear
leveling legs. The ice maker must be level to operate
properly.
To level and adjust the height:
1. With one person holding the ice maker, carefully
tilt the machine to access the leveling legs.
2. Use an adjustable wrench to turn the legs.
Turn legs right to lower, turn left to raise the ice
maker.
3. Check top and side with a level. Continue adjusting
legs until the ice maker is level and stable.
Raise Lower
7
WATER SUPPLY SET-UP
A cold water supply
with water pressure
between 30 and
120 p.s.i. is required
for ice maker
operation.
7RDOORZVXȻFLHQW
ZDWHUÀRZWR
the ice maker, a
minimum 1/2”
diameter home
supply line is recommended.
Route GE SmartConnect
Kit or 1/4” O.D. copper
tubing between house cold water line and the
water connection location.
The water line should be long enough to extend to
the back of the ice maker when the unit is moved
forward for service.
Install tubing only in areas where temperatures
will remain above freezing.
The water line should be flushed to clear any
foreign material before connecting to the ice maker.
NOTE: The only GE approved plastic tubing is supplied
in the GE SmartConnect
Refrigerator Tubing kits.
Do not use any other plastic water supply line. The
line is under pressure at all times. Other types of
plastic may crack or rupture with age and cause
water damage to your home. Order parts below at
GEApplianceParts. com or by calling 1.800.626.2002.
GE SmartConnect
Refrigerator Tubing Kits are
available in the following lengths:
2’ (0.6 m) WX08X10002 15’ (4.6 m) WX08X10015
6’ (1.8 m) WX08X10006 25’ (7.6 m) WX08X10025
Tools and Parts Needed:
Gather the required tools and parts before starting
installation:
z Flat-blade screwdriver
z 7/16” and 1/2” open-end wrenches or two
adjustable wrenches
z 1/4” nut driver
z 1/4” (6.35 mm) soft copper or GE SmartConnect
tubing
NOTE: Do not use a piercing-type or 3/16” (4.76 mm)
VDGGOHYDOYHZKLFKUHGXFHVZDWHUÀRZDQGFORJV
more easily.
Installation Instructions
8
CONNECT WATER SUPPLY TO
APPLIANCE
The water line should be flushed to clear any foreign
material before connecting to the ice maker.
Connect the water line to the water supply tube
outside of the rear access cover.
Copper Tubing:
Use a standard plumbing female connector or union
for 1/4” copper tubing that can be purchased locally.
GE SmartConnect
Tubing:
1. Insert the molded end of the tubing into the ice
maker connection. Tighten the compression nut
until it is just hand tight.
2. Tighten one additional turn with a wrench. Over-
tightening can cause leaks!
3. Make sure there are no sharp bends or kinks that
could restrict water flow.
CONNECT WATER LINE
1. Turn off main water supply. Turn on nearest faucet
to clear water line.
2. ,QVWDOODVKXWRȺYDOYHEHWZHHQWKHLFHPDNHUZDWHU
valve and cold water pipe. The installation of an
HDVLO\DFFHVVLEOHVKXWRȺYDOYHLQWKHZDWHUOLQHLV
required.
For Copper Tubing:
Use a squarely cut 1/4” (6.35 mm) soft copper tubing
for the cold water supply.
Ensure you have the proper length of copper wire
and that the ends have been cut square.
Remove and discard the short, black plastic tube, if
applicable, from the end of the inlet water tube.
Copper tube
Compression
sleeve
Water tube
connection
Compression nut
For GE SmartConnect
Tubing:
Insert the molded end of the tubing into the ice
maker connection. Tighten the compression nut
until it is just hand tight.
Tighten one additional turn with a wrench. Over-
tightening can cause leaks!
Make sure there are no sharp bends or kinks that
could restrict water flow.
3. Thread compression nut onto water supply line
connector. Tighten nut until finger-tight. Tighten
with a wrench two more turns. Do not over-tighten.
NOTE: To avoid rattling, be sure copper tubing does
not touch the cabinet’s side wall or other parts
inside the cabinet.
4. Install water supply tube clamp around water
supply line to reduce strain on the coupling.
5. Turn shutoff valve ON.
6. Check for leaks. Tighten any connections (including
connections at the valve) or nuts that leak.
REVERSE OSMOSIS WATER SUPPLY
IMPORTANT: The performance of the ice maker
may be affected when it is connected to a reverse
osmosis system.
z The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of
the ice maker needs to be between 30 and 120 psi.
z If a reverse osmosis system is connected to your
cold water supply, the water pressure to the system
must be a minimum of 40 to 60 psi. The reverse
osmosis system must provide 1 gal. of water
per hour to the ice maker for proper ice maker
operation.
z5HYHUVHRVPRVLVZDWHU¿OWUDWLRQV\VWHPVFDQEH
used only with ice maker installations that have a
gravity drain.
z Do not use copper tubing when the ice maker is
connected to a reverse osmosis water system.
CONNECT WATER LINE (cont.)
Installation Instructions
9
CONNECT DRAIN
This ice maker is
equipped with a gravity
drain to prevent water
from flowing back into
the storage bin and
overflowing onto
the floor. The ideal
installation has a
standpipe with a 2”
to 1-1/2” PVC drain
reducer installed directly
below the drain tube:
A 1” min. physical gap
between the bottom of
the ice maker drain hose
and the top of the house
drain is required. See
illustration.
– 7-1/2” to centerline
of the opening.
Approximately 3-1/2” high.
22” from the front, or
22-3/4” when installing a
3/4” door panel.
Drain lines must be at least 5/8” inside diameter.
NOTE: A drain pump is necessary when a floor
drain is not available. Order ZPK2 Drain Pump Kit
or contact your local plumber for a recommended
pump available in your area.
TEST DRAIN HOSE ALIGNMENT: Before sliding the
ice maker into the cabinet opening, check to be sure
the bottom of the drain tube is below the rear cover.
To test, place a pan below the drain hose. Slowly
pour a gallon of water into the ice bin and check to
be sure that water does not wet the rear cover.
1-7/8”
22”
22-3/4” with 3/4”
Custom Panel
1” Min. Gap
Drain Hose
Installation Instructions
REVERSE THE DOOR SWING
IMPORTANT:
Disconnect power to the ice maker.
Tools Required:
1/4” wrench (SS models)
Torx screwdriver, size 20
Phillips screwdriver
Parts Identification: (For Reference Only)
Torx Door Catch
Screw
Hex Head Door
Skin Screw
Torx Hinge
Screw
Endcap Screw
Hinge Pin
Phillips Head
Handle Screw
10
STEP 1 - REMOVE DOOR
For Black Model:
Remove the handle screws and lift off handle.
For Stainless Steel Model:
Remove two hex screws each from the bottom of
the stainless steel door skin.
Pull out on the bottom portion of the door skin and
lift up to remove.
STEP 2 - DOOR STOP AND END-CAP REVERSAL
1. Remove the hinge pin from the top hinge.
2. Remove the door from the hinges and replace the
top hinge pin.
3. Remove the screw and door stop at upper left
corner. Remove the screw and end cap at lower
right corner. Place the door stop at lower right
corner and tighten screw. Place the end cap at
upper left corner and tighten screw.
4. Remove the screw and door stop at lower left
corner. Remove screw and end cap from upper
right corner. Place the door stop at upper right
corner and tighten screw. Place the end cap at
lower left corner and tighten screw.
5. Set the door aside.
REVERSE THE DOOR SWING (cont.)
Screws
Handle
Hex screws
Stainless steel
door skin
Hinge pin
Installation Instructions
11
STEP 3 - REVERSE HINGES
1. Unscrew hinge screws and remove the top hinge.
Replace screws in empty hinge holes.
2. Remove screws from opposite side of ice maker
cabinet. Turn top hinge upside down so the hinge
pin points up. Place hinge on the bottom opposite
side of ice maker and tighten screws.
3. Remove original bottom hinge screws and hinge.
Replace screws in the empty hinge holes.
4. Remove screws from top of opposite side of ice
maker cabinet. Turn hinge upside down so the
hinge pin points down. Place hinge on top opposite
side of ice maker cabinet and tighten screws.
5. Remove the top hinge pin.
REVERSE THE DOOR SWING (cont.) REVERSE THE DOOR SWING (cont.)
Hinge
Hinge Pin
Hinge Scr
ew
Top Hinge
STEP 4 - REPLACE DOOR
For Black Model:
Align handle with the holes in the door and replace
screws. Tighten.
For Stainless Steel Model:
1. Replace the door skin on the door. Start by placing
the top of the skin over the top of the door. Slide
the sides in behind the side protectors. Line up
the bottom of the skin with the two holes on the
bottom of the door.
2. Replace two hex screws in the bottom of the
stainless steel door skin.
STEP 5 - REVERSE DOOR CATCH
1. Remove the plastic screws from the op po site side
of the door.
2. Remove the metal screws from the mag net ic door
catch and reinstall on the op po site side of the door.
3. Install the plastic screw into place on the op po site
side of the door.
Hinge
Hinge Scr
ews
Hinge Pin
Bottom Hinge
Door Catch
Installation Instructions for ZPK2
12
BEFORE YOU BEGIN:
Read these instructions completely and carefully.
IMPORTANT:
Save these instructions for local inspector’s use.
IMPORTANT:
Observe all governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions
with your Owner’s Manual for future reference.
NOTE:
This auxiliary drain pump is designed to pump
water to a maximum height of 10 feet and a
maximum horizontal distance of 100 feet.
To minimize condensation on the drain tube,
insulate the full length of the tube from the pump
to the drain.
WARNING:
Disconnect electrical power supply to ice maker
before installing pump. Failure to do so can result
in death, fire, or electrical shock. Replace all panels
before operating.
AVERTISSEMENT :
Débranchez l’alimentation électrique à la machine
à glaçons avant d’installer la pompe. L’omission de
prendre cette précaution peut entraîner la mort,
l’incendie ou le choc électrique. Replacez tous les
panneaux avant l’utilisation.
KIT CONTENTS:
Auxiliary drain pump
Drain tube, 5/8” ID x 5-1/8” (bin to pump reservoir
inlet)
Drain tube, 1/2” ID x 10’ (pump check valve to house
drain)
Vent tube, 5/16” ID x 32” (pump reservoir vent to
cabinet back)
3 cable clamps (secures vent tube to back of
product)
5 screws, #8 - 32 x 3/8” (secures pump to baseplate
and clamps to back of ice maker)
Small hose clamp 5/8” (secures vent and drain tube
to pump)
3 large adjustable hose clamps 7/8” (secure drain
tube to bin and auxiliary drain pump reservoir inlet)
secure hose drain to pump
2 rear covers
Installation Instruction Sheet
1 zip tie
13
1. Unplug power cord from rear cover.
2. Remove screws holding the rear cover. Retain
screws. Carefully pull rear cover away from drain
tube.
3. Remove old drain tube and clamp attached to bin.
Discard the tube and clamp.
Installation Instructions
STEP 1 - REMOVE ORIGINAL PARTS
Old Drain Hose
Clamp
Old Drain Tube
Remove Screws
NOTE: If pump is being installed on a ice maker that
has not been completely installed, please proceed
to Drain Pump Install section.
1. Attach vent tube to pump with new 5/8” hose
clamp. Attach drain tube from bin to pump with
7/8” hose clamp.
2. Coil ice machine power cord into a 4” dia. coil and
secure with electrical tape. Place the coil onto the
top of the pump.
1. Position pump at the right side, just outside of the opening.
2. Plug the ice machine power cord into the front of
the pump.
STEP 2 - CONNECT ELECTRICAL
Pump Power Cord
Ice
machine
Power
Cord
STEP 3 -INSTALL NEW TUBING
Plug Ice machine
Power Cord into
Pump
New 7/8”
Adjustable
Hose
Clamp
Vent Tube
5/8”Adjustable
Hose Clamp
14
Installation Instructions
Install the new drain tube with the new 7/8” clamps.
1. Place rear cover against the back of the ice
machine. Route the vent tube, power cord, drain
tube, and water supply line through cut outs in
the rear cover.
2. Secure rear cover with original screws.
Attach vent tube to unit with clamps as shown.
3. Trim one end of hose at 3/4” diameter. Secure
5/8” diameter section to pump with 7/8”
adjustable hose clamp
4. Route drain tube to house drain.
STEP 5 - INSTALL BIN DRAIN TUBE
STEP 6 - SECURE VENT TUBE
NOTE: While performing installations described in this
book, safety glasses or goggles should be worn.
NOTE: Product improvement is a continuing endeavor at
General Electric. Therefore, materials, appearance and
specifications are subject to change without notice.
7/8”Adjustable
Hose Clamp
Water Supply
Vent
Tube
1/2” Drain tube
Power Cord
Clamps and Screws
New 5/8” Drain Tube
New 7/8” Adjustable
Hose Clamp Installed
1. Carefully slide the auxiliary drain pump into the
bottom of the ice machine. The tab on the back of
the pump should slip into the rectangular slot on
the ice machine floor. It may be necessary to tip
the pump slightly to engage the tab.
NOTE: The pump must be in position before
connecting the bin drain tube. Slide pump tab into
floor slot in the bottom of the cabinet. See Step 5.
2. Secure the pump to the base with the 2 supplied
screws.
STEP 4 -INSERT DRAIN PUMP
Mounting Tab Slot
Pump Mounting Screws
Installation Instructions for ZIP75BB Kit
15
NOTE: If installing a 3/4” trimless custom panel,
a 1-1/2” wide filler strip may be required. The filler
strip will act as a spacer between the ice maker
case and the adjacent cabinet, and will prevent
interference with the ice maker door swing when
it is installed between frameless or framed
cabinetry. The width of the cutout opening must
include the width of the filler strip. The product
cannot be installed flush to adjacent 24 deep
cabinets with a 3/4” thick custom panel.
This kit contains a new handle and two side
mounting brackets to support a trimless custom
door panel up to 3/4” thick. A custom handle
may replace the supplied handle.
IMPORTANT:
Cut edges of the custom door panel will be
seen and must be finished for best ap pear ance.
The back side of the panel should be finished a
minimum of 1/2” on all sides.
The custom panel, both raised and flat design,
should be con struct ed in the same manner
as typical cabinet doors.
Order the custom panel from the cabinet
manufactur er. Be sure to provide the exact
dimensions so that the panel is con struct ed
accurately.
BEFORE YOU BEGIN:
Read these instructions completely and carefully.
IMPORTANT:
Save these instructions for local inspector’s use.
IMPORTANT:
Observe all governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions
with your Owner’s Manual for future reference.
WARNING:
Disconnect electrical power supply to ice maker
before installing front panel. Failure to do so can
result in death, fire, or electrical shock. Do not
operate ice maker while installing panel.
AVERTISSEMENT :
Il faut debrancher l’alimentation de la machine
à glaçons avant d’installer le panneau avant.
Le non-respect de ces instructions peut causer
la mort, un incendie ou un choc électrique. N’utilisez
pas la machine à glaçons pendant l’installation du
panneau.
Kit Contents:
2 side trim pieces
8 side trim screws
Door handle
Tools and Materials Required:
8 #6 flat head wood screws, 1/2” long
Drill and 1/8” bit
Safety glasses
Tape
Custom panel
Installation Instructions for ZIP75BB Kit
16
DISCONNECT POWER TO THE
ICE MACHINE
STEP 1
REMOVE HANDLE AND
NAMEPLATE
1. Remove the door handle by removing the two
top mounting screws. Set screws aside. Discard
handle.
2. The Monogram nameplate is held in place with
adhesive. Remove the nameplate.
STEP 2
INSTALL ASSEMBLED PANEL
ONTO THE ICE MACHINE
Install panel to ice maker with supplied screws, four
on each side.
STEP 6
INSTALL SUPPLIED
DOOR HANDLE (IF USED)
Install the new supplied handle with original screws.
STEP 7
MARK MOUNTING SCREW
LOCATIONS
1. Align and hold the side trim pieces against the ice
maker door and mark screw locations on the sides.
2. Drill 1/8” pilot holes into the door sides of the ice
maker.
STEP 3
SECURE SIDE TRIM PIECES
TO CUSTOM PANEL
1. Lay the custom panel appearance-side-down on a
clean surface.
2. Align top and bottom side trim to the custom
panel sides.
3. Tape the side trim pieces to the back of the
custom panel.
4. Place the panel with trim against the door to be
sure that trim and panel fits the door side to side
and top to bottom. Adjust as needed.
5. Mark screw locations and remove trim.
Drill pilot holes.
6. Install side trim to the back side of the custom
panel with screws (not supplied). Use flat head
wood screws 1/2” long.
STEP 5
SECURE CUSTOM HANDLE
TO CUSTOM PANEL.
(SKIP THIS STEP IF YOU ARE
USING THE SUPPLIED HANDLE)
1. A custom handle can be installed onto the 3/4”
thick panel, replacing the supplied handle.
2. The custom handle can be installed at the top or
side of the panel.
3. Drill pilot holes through the front of the custom
panel to match the chosen handle.
4. Secure the handle to the panel with flat head
wood screws.
5. Replace original handle screws in the top of the
door frame.
STEP 4
Notes
17
Pub. No. 31-49006
Part No.
245D1420P001
W10136140A 06-13 GE
Printed in the United States
NOTE: While performing installations described in this book,
safety glasses or goggles should be worn.
For Monogram
®
local service in your area, call
1.800.444.1845.
NOTE: Product improvement is a continuing endeavor
at General Electric. Therefore, materials, appearance
and specifications are subject to change without notice.
GE Appliances & Lighting
Appliances
General Electric Company
Louisville, KY 40225
GEA
pp
liances.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

GE ZDIC150WBB Guide d'installation

Catégorie
Fabricants de glaçons
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues