Simplicity 040410-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Installation & Operator’s Manual
Power
Management
System
Not for
Reproduction
2 BRIGGSandSTRATTON.COM
Briggs & Stratton Power Products Group, LLC
P.O. Box 702
Milwaukee, WI 53201-0702
Copyright © 2010. All rights reserved. No part of this material may
be reproduced or transmitted in any form without the express written
permission of Briggs & Stratton Power Products Group, LLC.
Thank you for your purchase of this Briggs & Stratton® Power Management System. This product is designed for use with
specific home standby generators and may not function with generators produced by other manufacturers. Seek a qualified
electrical professional to determine applicability of this equipment to generators manufactured by others. When operated
and maintained according to the instructions in this manual, your power management system will provide many years of
dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with this system and how to
avoid them. We have made every effort to provide for a safe, streamlined and cost-effective installation. As each installation
is unique, it is impossible to know of and advise of all conceivable procedures and methods by which installation might be
achieved. We do not know all possible hazards and/or the results of each possible method or procedure. It is important that
you read and understand these instructions thoroughly before attempting to install or operate this equipment. Save these
original instructions for future reference.
This power management system requires professional installation before use. Refer to the Installation section of this
manual for instructions on installation procedures. Only licensed electrical contractors should install power management
systems. Installations must strictly comply with all applicable federal, state and local codes, standards and regulations. The
installer should follow the instructions completely.
Where to Find Us
You never have to look far to find Briggs & Stratton support and service for your system. Consult your Yellow Pages.
There are many authorized service dealers who provide quality service. You can also contact Technical Service by phone at
(800) 743‑4115 between 8:00 AM and 5:00 PM CT, or on the Internet at BRIGGSandSTRATTON.COM.
For Future Reference
Please fill out the information below and keep with your receipt to assist in unit identification for future purchase issues.
Power Management System
Model Number
Revision
Serial Number
Date Purchased
Not for
Reproduction
3
Table of Contents
Important Safety Instructions........................4
Installation ....................................5
Owner Orientation ............................................5
Installing Dealer/Contractor Responsibilities .......................5
Mounting Guidelines ..........................................6
Power Wiring Interconnections ..................................7
System Setup................................................9
System Test .................................................9
Operation .................................... 10
Wiring Decal................................................11
Electrical Load Worksheet .....................................12
Maintenance .................................. 13
Troubleshooting................................ 14
Warranty..................................... 15
Product Specifications ........................... 16
Not for
Reproduction
4 BRIGGSandSTRATTON.COM
Save These Instructions
Important Safety Instructions
SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation and maintenance of the equipment.
Safety Symbols and Meanings
The safety alert symbol indicates a potential personal
injury hazard. A signal word (DANGER, WARNING, or
CAUTION) is used with the alert symbol to designate a
degree or level of hazard seriousness. A safety symbol
may be used to represent the type of hazard. The signal
word NOTICE is used to address practices not related to
personal injury.
DANGER indicates a hazard which, if not avoided, will
result in death or serious injury.
WARNING indicates a hazard which, if not avoided, could
result in death or serious injury.
CAUTION indicates a hazard which, if not avoided, could
result in minor or moderate injury.
NOTICE addresses practices not related to personal injury.
The manufacturer cannot possibly anticipate every possible
circumstance that might involve a hazard. The warnings in
this manual, and the tags and decals affixed to the unit are,
therefore, not all-inclusive. If you use a procedure, work
method or operating technique that the manufacturer does
not specifically recommend, you must satisfy yourself that
it is safe for you and others. You must also make sure that
the procedure, work method or operating technique that you
choose does not render the equipment unsafe.
Electrical Shock Read Manual
NOTICE Only qualified electricians should attempt
installation of this equipment, which must strictly comply
with applicable codes, standards and regulations.
WARNING Certain components in this product and
related accessories contain chemicals known to the State
of California to cause cancer, birth defects, or other
reproductive harm. Wash hands after handling.
WAR NING Low voltage wire cannot be installed in
same conduit as power voltage wiring.
Failure to follow above warning could cause personal •
injury, damage and/or malfunction of equipment.
WAR NING Failure to properly ground equipment can
result in electrocution.
Do not touch bare wires.•
Do not use equipment with worn, frayed, bare or •
otherwise damaged wiring.
Do not handle electrical cords while standing in water, •
while barefoot, or while hands or feet are wet.
If you must work around a unit while it is operating, stand •
on an insulated dry surface to reduce shock hazard.
Do not allow unqualified persons or children to operate or •
service equipment.
In case of an accident caused by electrical shock, •
immediately shut down all sources of electrical power
and contact local authorities. Avoid direct contact with
the victim.
NOTICE Improper treatment of equipment can damage it
and shorten its life.
Use equipment only for intended uses.•
If you have questions about intended use, ask dealer or •
contact Briggs & Stratton Power Products.
Do not expose equipment to excessive moisture, dust, •
dirt, or corrosive vapors.
Remain alert at all times while working on this equipment. •
Never work on the equipment when you are physically or
mentally fatigued.
If connected devices overheat, turn them off and turn off •
their circuit breaker/fuse.
WAR NING Equipment contains high voltage that can
cause personal injury or death.
Despite the safe design of the system, operating this •
equipment imprudently, neglecting its maintenance or
being careless can cause possible injury or death.
Not for
Reproduction
5
Installation
We sincerely appreciate your patronage. For this reason,
we have made significant effort to provide for a safe,
streamlined and cost-effective installation. Because each
installation is unique, it is impossible to know of and advise
the trade of all conceivable procedures and methods by
which installation might be achieved. Neither could we know
of possible hazards and/or the results of each method or
procedure. For these reasons,
Only current licensed electrical should attempt system
installations. Installations must strictly comply with all
applicable codes, industry standards and regulations.
Your equipment is supplied with this combined “Installation
and Operator’s Manual”. This is an important document and
should be retained by the owner after the installation has
been completed.
Every effort has been expended to make sure that the
information in this manual is both accurate and current.
However, the manufacturer reserves the right to change,
alter or otherwise improve the system at any time without
prior notice.
Home Owner Responsibilities
To help you make informed choices and communicate
effectively with your installation contractor(s),
Read and understand Owner Orientation before contracting
or starting your equipment installation.
To arrange for proper installation, contact the store at which
you purchased your equipment, your dealer, or your utility
power provider.
The equipment warranty is VOID unless the system is
installed by licensed electrical professionals.
Owner Orientation
The illustrations provided are for typical circumstances and
are meant to familiarize you with the installation options
available with your system.
Local codes, appearance, and distances are the factors that
must be considered when negotiating with an installation
professional. As the distance from the existing electrical
service increases, compensation in wiring materials must
be allowed for. This is necessary to comply with local codes
and overcome electrical voltage drops.
These factors will have a direct effect on the overall price
of your equipment installation.
NOTE: Your installer must check local codes AND obtain
permits before installing the system.
 • Readandfollowtheinstructionsgiveninthismanual.
 • Followaregularscheduleincaringforandusingyour
equipment, as specified in this manual.
Installing Dealer/Contractor Responsibilities
 • Readandobservethesafetyrules.
 • Readandfollowtheinstructionsgiveninthismanual.
 • Consultwithownertodetermineloadstobecontrolled
and their priorities.
NOTE: A worksheet for determining which loads are to be
transferred and their priorities is provided in Electrical Load
Worksheet, later in this manual.
 • Theinstallermayneedtoprovideappropriaterated
contactors based on loads to be controlled.
Equipment Description
The system is designed to control four priority loads and up
to two air conditioner loads that are being supplied by power
generated by the home standby system. This system goes
into a STANDBY mode and does not control any loads when
utility power is present.
The power management system consists of four 50 Amp,
2 HP, 2 pole relays; four control relays for central air
conditioning control wiring (maximum 1 Amp, 30VAC, two of
these relays are air conditioner lockout). The circuit boards
are housed in a NEMA 3R enclosure that is suitable for both
indoor and outdoor installations.
Relays A1 and A2 are configured with a 5 minute delay for
use with air conditioning control wiring. The 5 minute delay
will allow the air conditioner head pressure to bleed off,
thus reducing in-rush current. Connecting air conditioner
power wires directly to contactors L1, L2, L3 or L4 is not
recommended. Possible failures include tripping of branch
circuit breaker, generator shutting down and damage to air
conditioner. Please contact the air conditioner manufacturer
to make sure that their unit incorporates a 5 minute starting
delay before you connect AC power wires to contactors L1,
L2, L3 or L4.
Two current transformers monitor generator current at
the transfer switch to ensure that generator load does
not exceed a predetermined level. Should load exceed the
predetermined level, the system will shed loads to prevent
the generator from overloading. Loads are added sequentially
when sufficient power becomes available.
The control module incorporates a LED for each relay. The
LOAD1 LED is lit when relay 1 is NOT supplying power
to the load (contactor is OPEN). The same is true for the
other three relay’s. There is also a STATUS LED on the
control module that flashes when the generator is supplying
power to the system and indicates that the equipment is
functioning properly.
Not for
Reproduction
6 BRIGGSandSTRATTON.COM
Delivery Inspection
After opening the carton, carefully inspect the contents for
any damage that may have occurred during shipment.
IMPORTANT: If loss or damage is noted at time of delivery,
have the person(s) making delivery note all damage on the
freight bill and affix his signature under the consignor’s
memo of loss or damage. If loss or damage is noted after
delivery, contact the carrier for claim procedures. Missing or
damaged parts are not warranted.
Shipment Contents
 • Powermanagementsystem(1)
 • Installationandoperator’smanual(1)
 • Fuse(2)
 • Fuseholder(1)
 • Currenttransformer(2)
 • Decal(1)
 • Screw(4)
 • Compactterminalblock(4)
 • 1/4”singlefemalelug(4)
 • 1/4”singlemale,singlefemalelug(2)
To be supplied by installer:
 • Connectingwireandconduit
 • Variousspecialtytools/equipment
Mounting Guidelines
The system circuitry is enclosed in a NEMA Type 3R
enclosure suitable for indoor/outdoor use. Guidelines for
mounting the enclosure include:
 • Installenclosureonafirm,sturdysupportingstructure.
 • TheenclosuremustbeinstalledwithminimumNEMA
3R hardware for conduit connections.
 • Levelandplumbtheenclosure.Thiscanbedone
by placing washers between the enclosure and the
mounting surface.
NOTE: UL mandates that “Class 2 field wiring shall be
contained in the upper (terminal block) portion of the
enclosure. High voltage field wiring shall be routed in a
manner to maintain separation (of 6 inch) to Class 2 wiring
(including PCB board).”
 • Neverinstallthedevicewhereanycorrosivesubstance
might drip onto the enclosure.
 • Protectthedeviceatalltimesagainstexcessive
moisture, dust, dirt, lint, construction grit and
corrosive vapors.
A typical installation is depicted below. It is best if the
enclosure is mounted near the main distribution panel, either
inside or outside the building. Discuss layout suggestions/
changes with the owner before beginning system installation.
Main
distribution
panel
Transfer
switch
Hot
water
heater
Air
conditioner
Service
disconnect
Generator
Watt -
hourmeter
Branch circuits
Disconnect
switch
Power
management
system
Contactor
Not for
Reproduction
7
Power Wiring Interconnections
All wiring must be the proper size, properly supported
and protected by conduit. All wiring should be done
per applicable federal, state and local codes, standards
and regulations. Obey wire type and torque specifications
printed on the terminal blocks and neutral/ground connector.
Complete the following connections between the
transfer switch, the power management system and the
main distribution panel. Also see Wiring Decal, later in
this manual.
1. Set generator’s system switch to OFF position.
2. Set generator’s circuit breaker to OFF (open) position.
3. In main distribution panel, identify loads and their
priorities (using list developed with owner) that will be
‘managed’ by the system. An Electrical Load Worksheet
is provided.
4. In main distribution panel, turn selected load circuit
breakers to OFF position.
5. Connect “GND” lug to an approved ground.
NOTE: Assure grounding electrode conductor is connected
and bonded per applicable federal, state and local codes,
standards and regulations.
Existing fuse
holder
Optional
fuse holder
To
GROUND
To 50A MAX
general
purpose
loads
To current
transformers
To air conditioning control
wiring (A1 and A2).
A3 and A4 are lockouts
TEST
button
WAR NING Low voltage wire cannot be installed in
same conduit as power voltage wiring.
Failure to follow above warning could cause personal •
injury, damage and/or malfunction of equipment.
NOTICE Improper installation can cause damage to the
circuit boards and shorten their life. Installing circuit
boards in live circuits will damage the board and is not
covered by warranty. ALWAYS disconnect ALL sources of
power prior to servicing.
Remove all power prior to installing this equipment. •
Failure to do so could cause internal damage to the board
when making electrical connections.
Turn generator to • OFF position.
Turn off utility power to the standby generator and •
transfer switch.
WARNING Battery posts, terminals and related
accessories contain lead and lead compounds, chemicals
known to the State of California to cause cancer and
reproductive harm. Wash hands after handling.
Not for
Reproduction
8 BRIGGSandSTRATTON.COM
6. As an optional step, install supplied fuse holder in
automatic transfer switch enclosure. Shown here is a
typical install location. Clear all metal shavings!
NOTE: If not using optional fuse holder, please follow
wiring decal attached to enclosure (see Wiring Decal).
7. Attach supplied “GENERATOR 240VAC” decal in close
proximity to optional fuse holder, if used.
NOTE: To satisfy separation of circuit requirement, low
voltage (Class 2) wiring must enter the enclosure 2 inches
(5 cm) away from the top of the board transformer.
See System Setup.
8. If optional fuse holder is used, perform steps 9 and
10 and omit step 11. If optional fuse holder is NOT
used, omit steps 9 and 10 and continue with step 11.
9. Using installer supplied 300VAC or greater wire and
supplied 1/4” single male, single female lugs, connect
generator 240VAC from generator side of transfer
switch to optional fuse holder installed in step 6. The
transfer switch and fuse holders are supplied with
1/4” male spade connectors.
10. Using installer supplied 300VAC or greater wire and
supplied 1/4” single female lugs, connect opposite
end of the optional fuse holder installed in step 6 to
terminal block in power management system labeled
“240VAC GENERATOR”. Proceed to step 12.
11. Using installer supplied 300VAC or greater wire and
supplied 1/4” single male, single female lugs, connect
generator 240VAC from generator side of transfer
switch to terminal block in power management system
labeled “240VAC GENERATOR”.
12. Remove current transformers from current transformer
kit, cut two pole connector ends off of current
transformer leads and discard. Strip wires and place in
supplied compact terminal blocks.
13. Using installer supplied 300VAC or greater wire, run
wires from compact terminal blocks to control module
terminal block labeled “CT1” and “CT2”.
14. Using installer supplied 300VAC or greater wire,
connect C (Common) and NO (Normally Open)
terminals on terminal block J9 of control module
in transfer switch to control module terminal block
labeled “TS COM” (see Wiring Decal) in power
management system.
15. Wire air conditioning control wiring to control module
terminal block labeled “A1”, “A2”, “A3”, and “A4” in
power management system.
NOTE: A1 is for air conditioner 1. A2 is for air conditioner 2.
A3 and A4 are lockout’s during power outage.
16. For 120VAC selected loads, remove wire from selected
load circuit breaker.
17. Connect the selected load wire to terminal block in
enclosure labeled “LOAD1” for priority 1 load.
18. Using installer supplied 300VAC or greater wire,
connect selected load circuit breaker to terminal block
in enclosure labeled “LINE” for priority 1 load.
19. Repeat steps 16 through 18 for all other 120VAC
priorities using terminals “LOAD2” through “LOAD4”.
20. For 240VAC selected loads, remove both wires from
selected load circuit breaker.
21. Connect both wires from the selected load to terminal
block in enclosure labeled “LOAD1” for priority 1 load.
22. Using installer supplied 300VAC or greater wire,
connect selected load circuit breaker to terminal block
in enclosure labeled “LINE” for a priority 1 load.
23. Repeat steps 20 through 22 for all other 240VAC
priorities using terminals “LOAD2” through “LOAD4”.
24. Tighten all wire connections/fasteners to proper torque.
See label inside power management system for proper
torque values.
1/4” single male,
single female lug
1/4” single
female lug
Add
GENERATOR
240VAC
decal
Add
supplied
fuse holder
Interior of
automatic
transfer
switch
Not for
Reproduction
9
System Setup
You must perform the following before operating the system:
 • SettheSW2andSW3dipswitchesonthepower
management system control board to match the KW
rating of the home standby generator, as described in
Setting Dipswitches.
 • Inmaindistributionpanel,turnselectedloadcircuit
breakers to the ON position.
Setting Dipswitches
Dipswitches are used to adjust control board operation
based on generator capacity and fuel source. SW2 (“ONE”)
and SW3 (“TEN”) switches are set to correspond to total
system kW rating. Dipswitch SW2 has units of 1,000 watts;
Dipswitch SW3 has units of 10,000 watts.
IMPORTANT: Set only one switch to On” position on
SW2 and SW3.
The “On” position for the dipswitches is the switch number
ON THE CONTROL BOARD, not on the switch. For example,
on a 27,000 watt generator, set SW3 dipswitch “20” to On
position. Set SW2 dipswitch “7” to On” position. 20,000
plus 7000 equals 27,000 watts.
IMPORTANT: After installation of the system is complete,
turn on utility power to the home standby generator and
transfer switch. Wait one minute before turning generator
system switch to AUTO.
System Test
With the generator system switch in AUTO, turn the service
disconnect feeding the transfer switch contactor to the OFF
position. After a few minutes the generator will start and the
transfer switch will transfer to generator power.
Press the test button on the control module (labeled
“SW1 TEST”) in the power management system. As the
button is pressed, a relay will energize. Each time the
button is pressed, the previous relay that was energized will
de-energize and the next relay will energize. This sequence
continues until all relays have been tested. If the test
button has not been pressed for a period of 30 seconds,
the test sequence will halt and the system will revert to
automatic control.
To return to utility power, turn the service disconnect feeding
the transfer switch to the ON position.
NOTICE Use extreme caution when setting dipswitches or
damage to control board will result.
Use a pencil or small piece of plastic to set the dipswitch.•
NEVER use a screwdriver or any type of metal object to •
set dipswitches.
Air Conditioning
control wiring
TS COM
connections
CT1 & CT2
connections
SW3
dipswitch
STATUS
LED
LOAD
LED’s
TEST
SW1
Control
board
transformer
SW2
dipswitch
Not for
Reproduction
10 BRIGGSandSTRATTON.COM
Operation
When the home standby generator is providing power to the
transfer switch, the power management system is constantly
monitoring generator output power. The system monitors
both incoming generator lines and keeps the home standby
generator loaded to a predetermined SET POINT. When the
current transformers on any line start to see current reach
SET POINT, the system will start shedding loads based on
the lowest priority and work its way to the highest priority.
When monitored current drops below SET POINT, the
system will start to add loads based on the highest priority
first, followed by the second highest until the generator
reaches SET POINT or all priorities are back on line. The
equipment will operate this way (shedding or adding loads)
until the transfer switch transfers back to utility power.
The system waits 10 seconds between adding or shedding
each load to permit the system to stabilize. When relays
A1 and A2 are opened, the relays will stay opened for
a minimum of 5 minutes or until the load can be added
without putting the generator over SET POINT load. When
contactors Load1, Load2, Load3 and Load4 are opened, the
relays will stay opened for a minimum of 30 seconds or until
the load can be added without putting the generator over
SET POINT.
If a large load demand is seen, the system will shed all
loads in less than 1 second to prevent the generator from
overloading. Once the demand has stabilized, the system will
re-load the generator, as described above.
In descending order, the priorities for load management
are A1, Load 1, Load 2, Load 3, Load 4, A2 (A1 is highest
priority and A2 the lowest). A3 and A4 are lockout’s in
generator mode.
Enclosure Door Mechanism
 • Toopendoor,pressthespring-loaddoorlocktothe
right and pull down on the door.
 • Tocloseandlatchdoor,pushdoorclosedagainst
enclosure. While in this position, push door upwards.
This will cause spring-load door lock to engage and
latch door in place.
NOTE: Enclosure door MUST be closed and latched at all
times except when system is being serviced.
Not for
Reproduction
11
Wiring Decal
Not for
Reproduction
12 BRIGGSandSTRATTON.COM
Priority 120VAC Electrical Appliances Priority 240VAC Electrical Appliances
Window Air Conditioner 1 Central Air Conditioner 1
Window Air Conditioner 2 Central Air Conditioner 2
Window Air Conditioner 3 Range/Stove
Refrigerator 1 Dryer
Refrigerator 2 Well Pump
Freezer 1 Hot Tub
Freezer 2 Pool Heater
Microwave Water Heater
Bathroom Other:________________________
Auxiliary Heater Other:________________________
Home Theater System Other:________________________
Garage Heater
Sink Water Heater
Other:________________________
Other:________________________
Other:________________________
IMPORTANT: DO NOT connect furnace, sewage pump or sump pump to the power management system.
Electrical Load Worksheet
Not for
Reproduction
13
Maintenance
The equipment is designed to be maintenance free under
normal usage. However, inspection and maintenance checks
should be made on a regular basis. Maintenance will consist
mainly of keeping the enclosure clean.
Visual inspections should be done at least once a month.
Access to the enclosure must not be obstructed. Keep
3 feet (92 cm) clearance around the device. Check for
an accumulation of dirt, moisture and/or corrosion on
and around the enclosure, loose parts/hardware, cracks
and/or discoloration to insulation, and damaged or
discolored components.
Perform the system test at least once every three months (as
described in System Test) unless a power outage occurs and
the generator system has gone through automatic sequence
in those three months. Allow the system to run for at least
30 minutes.
Contact a licensed electrical professional to inspect and clean
the inside of the enclosure and other components of your
home generator system at least once a year.
When Calling for Assistance
You must have the Model Number and Serial Number from
the unit ID label at hand if it is necessary to contact a local
service center regarding service or repair of this unit. Obtain
this information from the unit ID label located on or inside
the enclosure.
To contact Briggs & Stratton call (800) 743‑4115, between
8:00 AM and 5:00 PM CT.
Not for
Reproduction
14 BRIGGSandSTRATTON.COM
Troubleshooting
Problem Cause Correction
Su pervised loads (air conditioner,
etc.) are not operating when
generator is supplying power
1. Load1 – Load4 contactors not
operating correctly.
2. Too much load on generator.
3. Current transformer not connected.
4. Broken current transformer.
5. Status LED stays lit constantly.
1. Contact an authorized service center.
2. Decrease load to generator.
3. Contact an authorized service center.
4. Contact an authorized service center.
5. Contact an authorized service center
No power to power management
system when generator is
running.
Blown fuse in transfer switch. Contact an authorized service center.
Not for
Reproduction
15
Warranty
ABOUT YOUR WARRANTY
We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most warranty
repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if
equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation. Similarly, the
warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered or modified. During
the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal
use and service. This warranty will not cover the following repairs and equipment:
• Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not cover
repair when normal use has exhausted the life of a part or the equipment.
• Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized
installation or alteration and modification, misuse, negligence, accident, overloading, improper maintenance, repair or storage so as, in our judgment,
to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments, cleaning and
fuse replacement.
• Other Exclusions: This warranty excludes wear items or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or
improper servicing. Accessory parts are excluded from the product warranty. This warranty excludes failures due to acts of God and other force
majeure events beyond the manufacturers control. Also excluded is used, reconditioned, and demonstration equipment. 198180E, Rev. D, 12/1/2009
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
MILWAUKEE, WI, USA
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC POWER MANAGEMENT SYSTEM
OWNER WARRANTY POLICY
LIMITED WARRANTY
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material or
workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This
warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest Authorized Service Dealer in
our dealer locator map at BRIGGSandSTRATTON.COM.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW. ANY AND ALL IMPLIED WARRANTIES ARE
EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some
states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you
may also have other rights which vary from state to state or country to country.
Effective November 1, 2009 replaces all undated Warranties and all Warranties dated before November 1, 2009
The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time stated in the
table above. “Consumer use” means personal residential household use by a retail consumer. “Commercial use” means all other uses, including use for
commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter be considered as commercial use for
purposes of this warranty. Equipment used for prime power in place of utility are not applicable to this warranty.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF PURCHASE
RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE MANUFACTURING
DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.
3 years
None
Consumer Use
Commercial Use
WARRANTY PERIOD
Not for
Reproduction
16 BRIGGSandSTRATTON.COM
* This power management system is listed per UL (Underwriters Laboratories) 916 (energy management equipment).
Product Specifications
Rated* AC Voltage .........................240 Volts
Frequency ...................................60 Hz
Contactor Rating
(L1, L2, L3, L4) ................. 240 VAC, 50A, 2 HP
Relay Contacts Rating
(A1, A2, A3, A4) ..................30 VAC, 1A, Class 2
Dimensions.....Approximately 24” H X 14” W X 6.5” Deep
Weight ..............................33 lbs (15 kg).
Not for
Reproduction
Manual de instalación
y del operario
Gestor de
alimentación
Not for
Reproduction
2 BRIGGSandSTRATTON.COM
Briggs & Stratton Power Products Group, LLC.
P.O. Box 702
Milwaukee, WI 53201-0702
Copyright © 2010. Reservados todos los derechos. Queda prohibida la reproducción
o transmisión de este material, sea cual sea la forma empleada para ello, sin el
permiso previo y por escrito de Briggs & Stratton Power Products Group, LLC.
Gracias por comprar este gestor de alimentación de Briggs & Stratton Power Products®. Este producto está diseñado para
utilizarse con generadores de reserva domésticos específicos y puede no funcionar con generadores producidos por otros
fabricantes. Recurra a un electricista profesional cualificado para determinar la aplicabilidad de este equipo en generadores
fabricados por terceros. Si se utiliza y mantiene de acuerdo con las instrucciones de este manual, su sistema de gestión de
energía le proporcionará muchos años de funcionamiento fiable.
Este manual contiene información de seguridad para que usted conozca los peligros y riesgos propios de este sistema y
cómo evitarlos. Se ha realizado el máximo esfuerzo para que la instalación resulte segura, sencilla y económica. Debido a que
cada instalación es única, es imposible conocer y recomendar todos los procedimientos y métodos posibles para efectuarla.
No conocemos todos los riesgos y/o resultados posibles de cada método o procedimiento existente. Es importante que lea
y comprenda perfectamente estas instrucciones antes de intentar instalar o utilizar este equipo. Guarde estas instrucciones
para futuras consultas.
Este sistema de gestión de energía requiere instalación profesional antes de utilizarse. Consulte las instrucciones sobre
los procedimientos de instalación en la sección Instalación del presente manual. Los sistemas de gestión de energía sólo
deben ser instalados por electricistas con licencia. Las instalaciones deben cumplir estrictamente la totalidad de los códigos,
estándares y regulaciones federales, estatales y locales vigentes. El instalador debe seguir las instrucciones detalladamente.
Ubicación
Nunca debe ir demasiado lejos para encontrar el soporte y servicio de Briggs & Stratton para su sistema. Consulte las
Páginas Amarillas. Existen múltiples distribuidores de servicio autorizados que ofrecen un servicio de calidad. También puede
comunicarse con el Servicio técnico por teléfono al (800) 743 4115 de 8:00 a. m. a 5:00 p. m. Hora del Centro, o a través de
Internet en BRIGGSandSTRATTON.COM.
Para futuras consultas
Llene la siguiente información y conserve su factura para facilitar la identificación de la unidad en caso de que surjan
problemas relacionados con la compra en el futuro.
Número de modelo
Revisión
Número de serie
Fecha de compra
Not for
Reproduction
3
Tabla de contenido
Instrucciones importantes de seguridad ................4
Instalación ....................................5
Orientación al propietario.......................................5
Responsabilidades del distribuidor/técnico instalador ................5
Directrices de montaje .........................................6
Interconexión de los cables de alimentación ........................7
Configuración del sistema ......................................9
Prueba del sistema............................................9
Funcionamiento................................ 10
Calcomanía del cableado ......................................11
Hoja de trabajo de cargas eléctricas .............................12
Mantenimiento ................................ 13
Resolución de problemas ......................... 14
Garantía . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Especificaciones del producto ...................... 16
Not for
Reproduction
4 BRIGGSandSTRATTON.COM
Conserve estas instrucciones
Instrucciones importantes
de seguridad
GUARDE ESTAS INSTRUCCIONES - Este manual contiene
instrucciones importantes que se deben seguir durante la
instalación y el mantenimiento del equipo.
Símbolos sobre la seguridad y significados
El símbolo de alerta de seguridad indica un posible
riesgo para su integridad física. Se utiliza una palabra de
señalización (PELIGRO, ADVERTENCIA o ATENCIÓN) junto
con el símbolo de alerta para designar un grado o nivel
de gravedad de riesgo. Se puede utilizar un símbolo de
seguridad para representar el tipo de riesgo. La palabra de
señalización AVISO se utiliza para hacer referencia a una
práctica no relacionada con una lesión física.
PELIGRO indica un riesgo que, de no evitarse, provocará
la muerte o lesiones de gravedad.
ADVERTENCIA indica un riesgo que, de no evitarse,
podría provocar la muerte o lesiones de gravedad.
ATENCIÓN indica un riesgo que, de no evitarse, podría
provocar lesiones leves o moderadas.
AVISO hace referencia a una práctica no relacionada con una
lesión física.
El fabricante no puede prever todas las posibles
circunstancias que pueden implicar riesgos. Por lo tanto, las
advertencias que aparecen en este manual y las etiquetas
y calcomanías adheridas a la unidad no incluyen todas las
posibilidades. Si aplica un procedimiento, método de trabajo
o técnica de operación no recomendada específicamente
por el fabricante, debe estar seguro de que se trata de una
práctica segura para usted y para otras personas. También
debe asegurarse de que el procedimiento, método de trabajo
o técnica de operación que elija, no haga que el sistema de
gestión de energía eléctrica se torne inseguro.
Descarga eléctrica Lea el manual
AVISO La instalación de este equipo debe cumplir
estrictamente la totalidad de los códigos, estándares y
regulaciones vigentes, por lo que sólo debe ser llevada a
cabo por un electricista cualificado.
ADVERTENCIA Determinados componentes en
este producto y los accesorios relacionados contienen
sustancias químicas declaradas cancerígenas, causantes
de malformaciones, y otros defectos congénitos por
el Estado de California. Lávese las manos después de
manipular estos elementos.
ADV ERTENCIA Los cables de baja tensión no se
pueden instalar en el mismo conducto que los
cables de suministro de energía.
Si no se respeta esta indicación pueden producirse •
lesiones, daños y/o fallos de funcionamiento del equipo.
ADV ERTENCIA Una conexión a tierra defectuosa del
equipo puede provocar la electrocución.
No toque los cables pelados.•
No utilice el equipo con cables desgastados, •
deshilachados o deteriorados de cualquier otra forma.
No manipule los cables eléctricos si se encuentra en •
una zona húmeda, está descalzo o tiene las manos o los
pies mojados.
Si tiene que trabajar junto a una unidad en •
funcionamiento, manténgase en una superficie aislada y
seca para reducir el riesgo de descarga eléctrica.
No permita que personas no cualificadas o niños utilicen •
o reparen el equipo.
En caso de accidente provocado por una descarga •
eléctrica, desconecte inmediatamente todos los
suministros de energía eléctrica y póngase en contacto
con las autoridades locales. Evite el contacto directo con
la víctima.
ADV ERTENCIA El equipo contiene alta tensión que
puede provocar lesiones o la muerte.
A pesar de la seguridad del diseño del sistema, si éste se •
utiliza con imprudencia, ignorando su mantenimiento o
sin las debidas precauciones, se pueden producir lesiones
o incluso la muerte.
AVISO Un tratamiento inadecuado del equipo puede
estropearlo y acortar su vida útil.
Utilice el equipo sólo para los usos previstos.•
En caso de dudas sobre su uso, diríjase al distribuidor o a •
Briggs & Stratton Power Products.
No exponga el equipo a un exceso de humedad, polvo, •
suciedad o vapores corrosivos.
Manténgase alerta en todo momento cuando utilice este •
equipo. Nunca lo utilice ni manipule en condiciones de
fatiga física o mental.
Si se calientan excesivamente los dispositivos conectados, •
apáguelos y abra sus interruptores o quite sus fusibles.
Not for
Reproduction
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Simplicity 040410-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur