OPERATOR’S MANUAL
IM544-B
June, 1998
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thoughtful
operation on your part. DO NOT
INSTALL, OPERATE OR REPAIR
THIS EQUIPMENT WITHOUT
READING THIS MANUAL AND
THE SAFETY PRECAUTIONS
CONTAINED THROUGHOUT. And,
most importantly, think before you
act and be careful.
For use with machines having Code Numbers:
9978, 10580 (Stick Model),
9979, 10581 (Stick and Wire Model)
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
World's Leader in Welding and Cutting Products Premier Manufacturer of Industrial Motors
FOR ENGINE
powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
____________________________________________________
1.b.Operate engines in open, well-ventilated
areas or vent the engine exhaust fumes
outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame weld-
ing arc or when the engine is running. Stop
the engine and allow it to cool before refuel-
ing to prevent spilled fuel from vaporizing on
contact with hot engine parts and igniting. Do
not spill fuel when filling tank. If fuel is spilled,
wipe it up and do not start engine until fumes
have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, coversand devices in posi-
tion and in good repair.Keep hands, hair, clothing and tools
away from V-belts, gears, fans and all other moving parts
when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.
___________________________________________________
1.f. Do not put your hands near the engine fan. Do
not attempt to override the governor or idler
by pushing on the throttle control rods while
the engine is running.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.
i
SAFETY
i
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you pur-
chase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040,
Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the
Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
WARNING
Mar ‘95
ELECTRIC AND
MAGNETIC FIELDS
may be dangerous
2.a. Electric current flowing through any conductor causes
localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines
2.b. EMF fields may interfere with some pacemakers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health
effects which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as
possible to the area being welded.
2.d.5. Do not work next to welding power source.
1.h. To avoid scalding, do not remove the
radiator pressure cap when the engine is
hot.
For Diesel Engines: Diesel engine exhaust and
some of its constituents are known to the State
of California to cause cancer, birth defects, and
other reproductive harm.
For Gasoline Engines: The engine exhaust from
this product contains chemicals known to the
State of California to cause cancer, birth defects,
or other reproductive harm.
CALIFORNIA PROPOSITION 65 WARNINGS
ii
SAFETY
ii
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
plates to protect your eyes from sparks and
the rays of the arc when welding or observing
open arc welding. Headshield and filter lens
should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits
are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground.
In addition to the normal safety precautions, if welding
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use
the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic
welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection
should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
of both welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
FUMES AND GASES
can be dangerous.
5.a. Welding may produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases.When welding, keep
your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special
ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
cadmium plated steel and other metals or coatings
which produce highly toxic fumes, keep exposure as
low as possible and below Threshold Limit Values (TLV)
using local exhaust or mechanical ventilation. In
confined spaces or in some circumstances, outdoors, a
respirator may be required. Additional precautions are
also required when welding on galvanized steel.
5.b.
Do not weld in locations near chlorinated hydrocarbon
vapors
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors
to
form phosgene, a highly toxic gas, and other irritating
products.
5.c. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
5.d. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employer’s safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.e. Also see item 1.b.
Mar ‘95
FOR ELECTRICALLY
powered equipment.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturer’s
recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
CYLINDER may explode
if damaged.
7.a. Use only compressed gas cylinders
containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
Away from areas where they may be struck or subjected to
physical damage.
A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand
tight except when the cylinder is in use or connected for
use.
7.g. Read and follow the instructions on compressed gas
cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
iii
SAFETY
iii
Mar ‘95
WELDING SPARKS can
cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
the welding sparks from starting a fire.
Remember that welding sparks and hot
materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.
6.c. When not welding, make certain no part of the electrode
circuit is touching the work or ground. Accidental contact can
cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even
though
they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the
Preparation
for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
6.f.
Sparks and spatter are thrown from the welding arc. Wear oil
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.
6.g. Connect the work cable to the work as close to the welding
area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate circuits.
This can create fire hazards or overheat lifting chains or
cables until they fail.
6.h. Also see item 1.c.
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour
votre propre protection lire et observer toutes les instructions
et les précautions de sûreté specifiques qui parraissent dans ce
manuel aussi bien que les précautions de sûreté générales suiv-
antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours
tout contact entre les parties sous tension et la peau nue
ou les vétements mouillés. Porter des gants secs et sans
trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher met-
allique ou des grilles metalliques, principalement dans
les positions assis ou couché pour lesquelles une grande
partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble de
soudage et la machine à souder en bon et sûr état defonc-
tionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à soud-
er parce que la tension entre les deux pinces peut être le
total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions
pour le porte-électrode s’applicuent aussi au pistolet de
soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger
contre les chutes dans le cas ou on recoit un choc. Ne jamais
enrouler le câble-électrode autour de n’importe quelle partie
du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel,
donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray-
onnement de l’arc et des projections quand on soude ou
quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la peau
de soudeur et des aides contre le rayonnement de l‘arc.
c. Protéger l’autre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de l’arc de
soudage. Se protéger avec des vêtements de protection libres
de l’huile, tels que les gants en cuir, chemise épaisse, pan-
talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de
soudage. Utiliser des lunettes avec écrans lateraux dans les
zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de
prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soud
e pas, poser la pince à une endroit isolé de
la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible de
la zone de travail qu’il est pratique de le faire. Si on place la
masse sur la charpente de la construction ou d’autres endroits
éloignés de la zone de travail, on augmente le risque de voir
passer le courant de soudage par les chaines de levage,
câbles de grue, ou autres circuits. Cela peut provoquer des
risques d’incendie ou d’echauffement des chaines et des
câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles
galvanisées plombées, ou cadmiées ou tout autre métal qui
produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant
d’opérations de dégraissage, nettoyage ou pistolage. La
chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs
du solvant pour produire du phosgéne (gas fortement toxique)
ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir
le code “Code for safety in welding and cutting” CSA Standard
W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de
l’électricité et aux recommendations du fabricant. Le dispositif
de montage ou la piece à souder doit être branché à une
bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront
effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch-
er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur
place.
Mar. ‘93
Thank You
for selecting a QUALITY product by Lincoln Electric. We want you
to take pride in operating this Lincoln Electric Company product •••
as much pride as we have in bringing this product to you!
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or
loss of life.
This statement appears where the information must be followed to avoid minor personal injury or damage to
this equipment.
CAUTION
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found
on your machine nameplate.
Model Name & Number _____________________________________
Code & Serial Number _____________________________________
Date of Purchase _____________________________________
Whenever you request replacement parts for or information on this equipment always supply the information you
have recorded above.
vv
TABLE OF CONTENTS
Page
Safety ................................................................................................................................................i-iv
Installation................................................................................................................................Section A
Technical Specifications................................................................................................................A-1
Safety Precautions ........................................................................................................................A-2
Location/ Ventilation ......................................................................................................................A-2
Stacking.................................................................................................................................A-2
Angle of Operation ................................................................................................................A-2
Lifting.....................................................................................................................................A-2
High Altitude Operation .........................................................................................................A-3
Towing ...................................................................................................................................A-3
Pre-Operation Engine Service ......................................................................................................A-3
Oil ..........................................................................................................................................A-3
Fuel........................................................................................................................................A-3
Fuel Cap................................................................................................................................A-4
Engine Cooling System.........................................................................................................A-4
Battery Connection................................................................................................................A-4
Muffler Outlet Pipe.................................................................................................................A-4
Spark Arrester .......................................................................................................................A-4
Electrical Output Connections ......................................................................................................A-4
Welding Output Cables..........................................................................................................A-5
Machine Grounding ...............................................................................................................A-5
Auxiliary Power Receptacles .................................................................................................A-5
Standby Power Connections .................................................................................................A-5
Operation..................................................................................................................................Section B
Safety Instructions.........................................................................................................................B-1
General Description ......................................................................................................................B-1
Recommended Applications..................................................................................................B-1
Design Features and Advantages.........................................................................................B-1
Welding Capability.................................................................................................................B-1
Controls and Settings....................................................................................................................B-3
Engine Controls.....................................................................................................................B-3
Welder Controls.....................................................................................................................B-5
Auxiliary Power Controls .......................................................................................................B-5
Engine Operation ..........................................................................................................................B-6
Starting the Engine................................................................................................................B-6
Stopping the Engine..............................................................................................................B-6
Break-In Period......................................................................................................................B-6
Typical Fuel Consumption .....................................................................................................B-6
Welder Operation ..........................................................................................................................B-7
Stick Welding.........................................................................................................................B-7
Pipe Welding .........................................................................................................................B-7
General Welding....................................................................................................................B-7
TIG Welding...........................................................................................................................B-7
Arc Gouging ..........................................................................................................................B-7
Wire Feed (Constant Voltage) Welding .................................................................................B-9
Connection of Stick and Wire model to LN-25, LN-7, LN-8, LN-23P or NA-3 ......................B-9
Auxiliary Power Operation...........................................................................................................B-10
Simultaneous Welding and Auxiliary Power Loads .............................................................B-10
Accessories .............................................................................................................................Section C
Optional Field Installed Accessories.............................................................................................C-1
Recommended Equipment ...........................................................................................................C-1
High Frequency Generators For TIG Applications........................................................................C-1
Maintenance.............................................................................................................................Section D
Safety Precautions........................................................................................................................D-1
Routine and Periodic Maintenance...............................................................................................D-1
Engine Maintenance .............................................................................................................
........D-1
Air Filter.................................................................................................................................D-1
Fuel Filters ............................................................................................................................D-2
Cooling System .....................................................................................................................D-3
Cooling Blower Belt...............................................................................................................D-3
Engine Maintenance Components........................................................................................D-4
Troubleshooting.......................................................................................................................Section E
Diagrams and Dimension Print ..............................................................................................Section F
Parts Manual.........................................................................................................................P267 Series
vivi
COMMANDER 400
A-1
INSTALLATION
COMMANDER 400
A-1
TECHNICAL SPECIFICATIONS - Commander 400
Make/Model Description Speed (RPM) Displacement Starting Capacities
System
Deutz 3 cylinder High Idle 1900 173 cu. in 12VDC battery Fuel: 25 gal.
F3L 912 Diesel 44.2 HP(33kw) Low Idle 1350 (2.827 L) & Starter 94.6 L
Engine @ 1800 RPM Full Load 1800
Bore x Stroke Oil: 8.5 Qts.
8.04 L
3.94” x 4.72”
(100mm x 120mm)
INPUT - DIESEL ENGINE
RATED OUTPUT - WELDER
HEIGHT
2
WIDTH DEPTH WEIGHT
42.0 in. 31.5 in. 63.1 in. 1650 lbs.(748 kg)
(Stick model)
1066.8 mm 800.1 mm 1602.7 mm 1683 lbs.(763 kg)
(Stick & Wire model)
OUTPUT - WELDER AND GENERATOR
Duty Cycle Welding Output Volts at Rated Amps
100%
400 amps (DC Constant Current) 40 volts
400 amps (DC Constant Voltage) 40 volts
60%
500 amps (DC Constant Current) 40 volts
500 amps (DC Constant Voltage) 40 volts
Welding Range Open Circuit Voltage Auxiliary Power
1
40 - 575 Amps 64-74 OCV 120/240 VAC
in 7 Ranges (Stick model) 10,000 Watts, 60 Hz.
or 8 Ranges
(Stick & Wire model)
@1915 RPM 100% Duty Cycle
PHYSICAL DIMENSIONS
1. Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.
2. Top of Enclosure. Add 6.64” (168.7mm) for exhaust.
A-2
INSTALLATION
COMMANDER 400
A-2
Read this entire installation section before you
start installation.
SAFETY PRECAUTIONS
Do not attempt to use this equipment until you have
thoroughly read all operating and maintenance man-
uals supplied with your machine. They include impor-
tant safety precautions, detailed engine starting,
operating and maintenance instructions and parts
lists.
ELECTRIC SHOCK can kill.
•Do not touch electrically live parts such
as output terminals or internal wiring.
•Insulate yourself from the work and
ground.
•Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
•Use in open, well ventilated areas or
vent exhaust outside
•Do not stack anything near the engine.
------------------------------------------------------------------------
MOVING PARTS can injure.
•Do not operate with doors open or
guards off.
•Stop engine before servicing.
•Keep away from moving parts
------------------------------------------------------------------------
Only qualified personnel should install, use or service
this equipment
LOCATION/VENTILATION
The welder should be located to provide an unrestricted
flow of clean, cool air to the cooling air inlets and to avoid
restricting the cooling air outlets. Also, locate the welder
so that the engine exhaust fumes are properly vented to
an outside area.
STACKING
Commander 400 machines cannot be stacked.
ANGLE OF OPERATION
To achieve optimum engine performance the
Commander 400 should be run in a level position. The
maximum angle of operation for the Deutz engine is 20
degrees in a direction to cause the control panel to be
angled up, 30 degrees for side to side tilting and for the
control panel to be angled down. If the engine is to be
operated at an angle, provisions must be made for
checking and maintaining the oil level at the normal
(FULL) oil capacity in the crankcase. When operating
the welder at an angle, the effective fuel capacity will
be slightly less than the specified 25 gallons.
LIFTING
The Commander lift bale should be used to lift the
machine. The Commander is shipped with the lift bale
retracted. Before attempting to lift the Commander the
lift bale must be secured in a raised position. Secure
the lift bale as follows:
a. Open the engine compartment door.
b. Locate the 2 access holes on the upper middle
region of compartment wall just below the lift
bale.
c. Use the lifting strap to raise the lift bale to the full
upright position. This will align the mounting
holes on the lift bale with the access holes.
d. Secure the lift bale with 2 thread forming screws.
The screws are provided in the shipped loose
parts bag.
FALLING EQUIPMENT can cause
injury.
•Do not lift this machine using lift bale if
it is equipped with a heavy accessory
such as a trailer or gas cylinder.
•Lift only with equipment of adequate
lifting capacity.
•Be sure machine is stable when lifting.
------------------------------------------------------------------------
WARNING
WARNING
A-3
INSTALLATION
COMMANDER 400
A-3
HIGH ALTITUDE OPERATION
At higher altitudes, output derating may be necessary.
As a rule of thumb, derate the welder output 5% for
every 400 meters (1312 ft.) above 1000 meters (3280
ft.).
Contact a Deutz Service Representative for any engine
adjustments that may be required for high altitude
operation.
TOWING
The recommended trailer for use with this equipment
for road, in-plant and yard towing by a vehicle
(1)
is
Lincoln’s K953-1. If the user adapts a non-Lincoln
trailer, he must assume responsibility that the method
of attachment and usage does not result in a safety
hazard nor damage the welding equipment. Some of
the factors to be considered are as follows:
1. Design capacity of trailer vs. weight of Lincoln
equipment and likely additional attachments.
2. Proper support of, and attachment to, the base of
the welding equipment so that there will be no
undue stress to the trailer’s framework.
3. Proper placement of the equipment on the trailer to
insure stability side to side and front to back when
being moved and when standing by itself.
4. Typical conditions of use, such as travel speed,
roughness of surface on which the trailer will be
operated, and environmental conditions.
5. Proper preventative maintenance of trailer.
6. Conformance with federal, state and local laws.
1
1
Consult applicable federal, state and local laws
regarding specific requirements for use on public high-
ways.
PRE-OPERATION ENGINE SERVICE
READ the engine operating and maintenance instruc-
tions supplied with this machine.
•Stop engine and allow to cool before
fueling.
•Do not smoke when fueling.
•Fill fuel tank at a moderate rate and do
not overfill.
•Wipe up spilled fuel and allow fumes to
clear before starting engine.
•Keep sparks and flame away from
tank.
------------------------------------------------------------------------
OIL
The Commander is shipped with the engine crankcase
filled with high quality SAE 10W-30 oil (API class CD or
better). Check the oil level before starting the engine. If it
is not up to the full mark on the dip stick, add oil as
required. Check the oil level every four hours of running
time during the first 35 running hours. Refer to the engine
Operator’s Manual for specific oil recommendations and
break-in information. The oil change interval is dependent
on the quality of the oil and the operating environment.
Refer to the engine Operator’s Manual for the proper ser-
vice and maintenance intervals.
FUEL USE DIESEL FUEL ONLY
Fill the fuel tank with clean, fresh diesel fuel. The capac-
ity of the fuel tank is 25 gallons (94.6 liters). See engine
Operator’s Manual for specific fuel recommendations.
The Commander 400 is protected by a low fuel shutdown
to prevent the engine from running out of fuel. The
machine will indicate a low fuel condition by turning on the
low fuel light. A time of 30 minutes will elapse once the
low fuel light illuminates before the machine will shut-
down. A restart of the machine will restart the timer to
allow the operator to override this feature. The amount of
reserve fuel remaining in the tank after the first shutdown
will vary from machine to machine. The operator must
determine the amount of fuel remaining before re-starting
the machine. Running out of fuel may require bleeding
the fuel injection pump.
NO
TE: Before starting the engine, open the fuel shutoff
valve (lever to be in line with hose) located on the side the
fuel pre-filter / water separator housing.
WARNING
A-4
INSTALLATION
COMMANDER 400
A-4
FUEL CAP
Remove the plastic cap covering from the Fuel Tank
Filler neck and install the Fuel Cap.
ENGINE COOLING SYSTEM
The Deutz engine is air cooled by a belt driven axial
blower. The oil cooler and engine cooling fins should
be blown out with compressed air or steam to maintain
proper cooling (See the engine Owners Manual for pro-
cedures and frequency).
BATTERY CONNECTION
WARNING: Use caution as the electrolyte is a strong
acid that can burn skin and damage eyes.
Remove and discard the insulating cap from the nega-
tive battery terminal. Attach and tighten negative bat-
tery cable terminal.
NOTE: This machine is furnished with a wet charged battery; if
unused for several months, the battery may require a booster
charge. Be careful to charge the battery with the correct polar-
ity. Make sure that the battery is level while charging.
MUFFLER OUTLET PIPE
Remove the plastic plug covering the muffler outlet
tube. Using the clamp provided secure the outlet pipe
to the outlet tube with the pipe positioned such that it
will direct the exhaust in the desired direction.
SPARK ARRESTER
Some federal, state or local laws may require that
gasoline or diesel engines be equipped with exhaust
spark arresters when they are operated in certain loca-
tions where unarrested sparks may present a fire haz-
ard. The standard muffler included with this welder
does not qualify as a spark arrester. When required by
local regulations, a suitable spark arrester, such as the
K899-1 must be installed and properly maintained.
An incorrect arrester may lead to damage to the engine
or adversely affect performance.
------------------------------------------------------------------------
CAUTION
ELECTRICAL OUTPUT CONNECTIONS
See Figure A.1 for the location of the weld output terminals, ground stud, and auxiliary power receptacles
FIGURE A.1 - Weld Terminal, Ground Stud and Auxiliary Power Receptacle Locations
0
OIL
00000
FUEL
TEMP
AMPS
PRESS
HOURS
+-
-
120 VOLT
RECEPTACLES
GROUND STUD
240 VOLT RECEPTACLE
WELD OUTPUT TERMINALS
CV WORK -
WELD OUTPUT
TERMINAL
(ELECTRODE + & CC WORK -)
A-5
INSTALLATION
COMMANDER 400
A-5
WELDING OUTPUT CABLES
With the engine off, route the electrode and work
cables thru the strain relief bracket provided on either
side of the base and connect to the terminals provided.
These connections should be checked periodically and
tightened if necessary.
Listed in Table A.1 are copper cable sizes recom-
mended for the rated current and duty cycle. Lengths
stipulated are the distance from the welder to work and
back to the welder again. Cable sizes are increased for
greater lengths primarily for the purpose of minimizing
cable voltage drop.
Table A.1 Combined Length of Electrode and Work
Cables.
MACHINE GROUNDING
Because this portable engine driven welder creates its
own power, it is not necessary to connect its frame to
an earth ground, unless the machine is connected to
premises wiring (home, shop, etc.).
To prevent dangerous electric shock, other equipment
powered by this engine driven welder must:
a) be grounded to the frame of the welder using a
grounded type plug,
or
b) be double insulated.
When this welder is mounted on a truck or trailer, its
frame must be securely connected to the metal frame
of the vehicle. When this engine driven welder is con-
nected to premises wiring such as that in a home or
shop, its frame must be connected to the system earth
ground. See further connection instructions in the sec-
tion entitled “Standby Power Connections” as well as
the article on grounding in the latest U.S. National
Electrical Code and the local code.
In general, if the machine is to be grounded, it should
be connected with a #8 or larger copper wire to a solid
earth ground such as a metal water pipe going into the
ground for at least ten feet and having no insulated
joints, or to the metal framework of a building which
has been effectively grounded. The U.S. National
Electrical Code lists a number of alternate means of
grounding electrical equipment. A machine grounding
stud marked with the symbol is provided on the
front of the welder.
AUXILIARY POWER RECEPTACLES
The auxiliary power capacity of the Commander 400 is
10,000 watts of 60 Hz, single phase power. The auxil-
iary power capacity rating in watts is equivalent to volt-
amperes at unity power factor. The maximum permis-
sible current of the 240 VAC output is 44 A. The 240
VAC output can be split to provide two separate 120
VAC outputs with a maximum permissible current of 44
A per output to two separate 120 VAC branch circuits.
The output voltage is within ± 10% at all loads up to
rated capacity.
NO
TE: The 120/240V receptacle has two 120V outlets
of different phases and cannot be paralleled.
The Commander has two 15 Amp-120VAC (5-15R)
duplex receptacles with GFCI protection and one 50
Amp-120/240 VAC (14-50R) receptacle. The 120/240
VAC receptacle can be split for single phase 120 VAC
operation. The auxiliary power receptacles should only
be used with three wire grounded type plugs or
approved double insulated tools with two wire plugs.
The current rating of any plug used with the system
must be at least equal to the current capacity of the
associated receptacle.
STANDBY POWER CONNECTIONS
The Commander 400 is suitable for temporary, stand-
by or emergency power using the engine manufactur-
er’s recommended maintenance schedule.
The Commander 400 can be permanently installed as
a standby power unit for 240 volt-3 wire, 44 amp ser-
vice. Connections must be made by a licensed electri-
cian who can determine how the 120/240 VAC power
can be adapted to the particular installation and com-
ply with all applicable electrical codes. The following
information can be used as a guide by the electrician
for most applications. Refer to the connection diagram
shown in Figure A.2.
1. Install the double-pole, double-throw switch between
the power company meter and the premises discon-
nect.
Switch rating must be the same or greater than the
customer’s premises disconnect and service over cur-
rent protection.
Up to 150
FT.
1 AWG
3/0 AWG
150-200 FT.
1 AWG
3/0 AWG
200-250 FT.
1/0 AWG
4/0 AWG
AMPS
@100%
Duty Cycle
250
400
TOTAL COMBINED LENGTH OF ELEC-
TRODE AND WORK CABLES
A-6
INSTALLATION
COMMANDER 400
A-6
2. Take necessary steps to assure load is limited to the
capacity of the Commander by installing a 45 amp,
240 VAC double pole circuit breaker. Maximum
rated load for each leg of the 240 VAC auxiliary is 45
amperes. Loading above the rated output will
reduce output voltage below the allowable -10% of
rated voltage which may damage appliances or
other motor-driven equipment and may result in
overheating of the Commander 400 engine.
3. Install a 50 amp 120/240 VAC plug (NEMA Type 14-
50) to the double-pole circuit breaker using No. 6, 4
conductor cable of the desired length. (The 50 amp,
120/240 VAC plug is available in the optional K802R
plug kit.)
4. Plug this cable into the 50 Amp 120/240 Volt recep-
tacle on the Commander 400 case front.
Figure A.2 Connection of the Commander 400 to Premises Wiring
240 Volt
60 Hz.
3-Wire
Service
POWER
COMPANY
METER
240 VOLT
120 VOLT
120 VOLT
LOAD
N
NEUTRAL
BUS
GROUND
PREMISES
DISCONNECT AND
SERVICE
OVERCURRENT
PROTECTION
GND
N
NOTE: No. 8 COPPER CONDUCTOR CABLE SEE
NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
SIZE RECOMMENDATIONS.
240 VOLT
GROUNDED CONDUCTOR
45AMP
240 VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
50 AMP, 120/240
VOLT PLUG
NEMA TYPE 14-50
50 AMP, 120/240 VOLT
RECEPTACLE
B-1
OPERATION
B-1
OPERATING INSTRUCTIONS
Read and understand this entire section before operat-
ing your Commander 400.
SAFETY INSTRUCTIONS
Do not attempt to use this equipment until you have
thoroughly read all operating and maintenance man-
uals supplied with your machine. They include impor-
tant safety precautions, detailed engine starting,
operating and maintenance instructions and parts
lists.
ELECTRIC SHOCK can kill.
•Do not touch electrically live parts such
as output terminals or internal wiring.
•Insulate yourself from the work and
ground.
•Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
•Use in open, well ventilated areas or
vent exhaust outside
•Do not stack anything near the engine.
------------------------------------------------------------------------
MOVING PARTS can injure.
•Do not operate with doors open or
guards off.
•Stop engine before servicing.
•Keep away from moving parts
------------------------------------------------------------------------
Only qualified personnel should operate this equip-
ment.
ADDITIONAL SAFETY PRECAUTIONS
Always operate the welder with the hinged door closed
and the side panels in place as these provide maxi-
mum protection from moving parts and insure proper
cooling air flow.
GENERAL DESCRIPTION
The Commander is a diesel engine driven welding
power source. The machine uses a brushless asyn-
chronous alternating current generator for DC stick
electrode welding and for 120/240 VAC auxiliary stand-
by power. As a generator it can supply up to 10,000
watts of 120/240 volt AC power. As a welder it provides
up to 400 amps of DC constant current output in six
slope-controlled ranges. In addition a seventh general
purpose welding range provides up to 575 amps of
constant current welding output.
The engine is a 44.2 Hp (33kw), 3-cylinder air/oil
cooled diesel made by Deutz. This naturally aspirated,
4 cycle engine features direct injection, a Bosch in-line
injection pump and a Bosch mechanical governor.
This machine is controlled by a high quality microcon-
troller. The microcontroller provides high speed control
of the weld process as well as the engine protection
features.
RECOMMENDED APPLICATIONS
WELDER
The Commander 400 (Stick model) provides excellent con-
stant current DC welding output for stick (SMAW) welding.
The Commander 400 (Stick & Wire model) also provides
excellent constant voltage DC welding output for MIG
(GMAW) and Innershield (FCAW) welding.
GENERATOR
The Commander 400 provides smooth 120/240 VAC
output for auxiliary power and emergency standby
power.
DESIGN FEATURES AND ADVANTAGES
(All Models)
FOR STICK WELDING
Excellent DC constant current output for stick weld-
ing applications.
• 40 to 400 amps output in six slope controlled ranges
for out-of position and pipe electrodes and 50 to 575
amps constant current output in one general purpose
welding range.
3 digit display is provided for presetting the weld
amperage and displaying the actual amperage during
welding. The display uses superbrite L.E.D.s for
improved readability in full sunlight.
• Remote control capability standard on all models.
COMMANDER 400
WARNING
B-2
OPERATION
B-2
FOR AUXILIARY POWER
• 10,000 watts of 120/240 VAC, 60Hz auxiliary power.
Drive a 2 HP motor (provided it is started under no
load).
Two 15 amp 120 VAC duplex receptacles with GFCI
protection for up to 30 amps of 120 VAC power.
One 50 amp, 120/240 VAC dual voltage receptacle for
up to 44 amps of 240 VAC, and up to 44 amps per
side to separate branch circuits (not in parallel) of 120
VAC single phase auxiliary power. Allows easy con-
nection to premises wiring.
Weld and AC auxiliary power at the same time (with-
in machine total capacity).
OTHER FEATURES
Deutz 3-cylinder, air/oil cooled diesel engine.
Designed for long life, easy maintenance and excel-
lent fuel economy.
Engine protection system shuts the engine down for
low oil pressure, high oil temperature or a broken
fan/engine alternator belt.
Gauges for oil pressure, oil temperature, engine alter-
nator output and fuel level.
Indicator lights for low oil pressure, high oil tempera-
ture, engine alternator low output/broken belt and low
fuel level.
Automatic low fuel shutdown before running out of
fuel.
• Engine hour meter standard on all models.
• Extended range 25 gallon (94.6 l) fuel tank.
Fuel pre-filter/water separator with “dry” change ele-
ment.
Automatic idler reduces engine speed when not weld-
ing or drawing auxiliary power. This feature reduces
fuel consumption and extends engine life.
Single side engine service with over the top access to
the engine.
Copper alternator windings and high temperature
insulation for dependability and long life.
ADDITIONAL DESIGN FEATURES AND
ADVANTAGES (Stick & Wire Model only)
FOR WIRE WELDING
One constant voltage position for all wire welding. A
12 to 45V range across the entire current output
range.
Excellent arc characteristics with MIG (GMAW) and
Innershield (FCAW) welding.
A Wire Feeder connector for quick connection of the
control cable.
A built in “Electronic Contactor” for “Cold” electrode
when not welding. This feature and DC Constant
Voltage output provide an added margin of safety
when welding must be performed under electrically
hazardous conditions such as: damp locations, while
wearing wet clothing or in cramped positions if there
is a high risk of unavoidable or accidental contact with
the workpiece or ground.
The 3 digit display has the additional feature of pre-
setting the open circuit voltage and displaying the
actual voltage during welding.
Designed for use with the following Lincoln wire feeders.
•LN-25 •LN-23P •LN-7
•LN-8 •NA-3 •Spool Gun &
K488 Module
WELDING CAPABILITY
The Commander 400 is rated at 400 amps, 40 volts at
100% duty cycle. The weld current is variable from 40
to 575 amps.
COMMANDER 400
Selection of “hot” or “cold” output terminals with a tog-
gle switch on the control panel. This feature can also
be controlled by installing a remote output terminal
control cable designed to open and close the #2 and
#4 leads in the amphenol receptacle.
MAY96
B-3
OPERATION
B-3
ENGINE CONTROLS (Items 1 through 8)
1. RUN- STOP SWITCH
When placed in the “RUN” position, this switch ener-
gizes the fuel solenoid and other electric accessories.
When placed in the “STOP” position, the flow of fuel to
the injection pump is stopped to shut down the engine.
(Note: If the switch is left in the “RUN” position and the
engine is not running, the battery will be drained by the
fuel solenoid).
2. START PUSHBUTTON
Energizes the starter motor to crank the engine. With
the engine RUN-STOP switch in the “Run” position,
push and hold the START button for a minimum of 2
seconds to crank the engine; release as the engine
starts. Do not press while engine is running since this
can cause damage to the ring gear and/or starter
motor.
3. FUEL LEVEL GAUGE AND LIGHT
Displays the level of diesel fuel in the 25-gallon fuel
tank. The yellow light turns on when the fuel gage
reaches the reserve level. Once the reserve level is
reached, the engine protection system will shut down
the engine after 30 minutes of operation. The machine
can be restarted and operated for an additional 30 min-
utes before the protection system will shut down the
engine. This ability to override the engine protection is
to allow the operator to “finish up” if necessary. The
operator must watch the fuel level closely to prevent
running out of fuel and having to bleed the system.
COMMANDER 400
CONTROLS AND SETTINGS
All welder and engine controls are located on the case front panel. Refer to Figure B.1 and the explanations that
follow.
Figure B.1 Case Front Panel Controls
0
OIL
2
9
17
23
00000
8
7
16
15
18
FUEL
TEMP
4
AMPS
5
6
PRESS
9
HOURS
13
22
21
24
20
3
1
10
11
12
19
14
+-
-
B-4
OPERATION
B-4
4. ENGINE TEMPERATURE GAUGE AND
LIGHT
The gauge displays the engine oil temperature. The
yellow temperature light remains off under normal
operating temperatures. If the light turns on, the
engine protection system will shut down the engine.
Check for restrictions at the engine cooling air inlets
and outlets (consult the engine Operator’s Manual).
Check for loose or disconnected leads at the tempera-
ture sender located on the engine. Check engine cool-
ing blower belt. Also, check to be sure that the welder
loads are within the rating of the welder. The light will
remain on when the engine has been shut down due to
an over- temperature condition.
5. OIL PRESSURE GAUGE AND LIGHT
The gauge displays the engine oil pressure when the
engine is running. The yellow oil pressure light
remains off with proper oil pressure. If the light turns
on, the engine protection system will stop the engine.
Check for proper oil level and add oil if necessary.
Check for loose or disconnected leads at the oil pres-
sure sender located on the engine. The light will go on
and stay on when the RUN-STOP switch is switched to
the “Run” position with engine not running.
6. ENGINE ALTERNATOR AMMETER
AND LIGHT
The yellow engine alternator light is off when battery
charging system is functioning normally. If light turns
on, the engine protection system will shut down the
engine. Check the engine cooling blower belt. Also,
the alternator or the voltage regulator may not be oper-
ating correctly. The light may also come on if the alter-
nator did not flash up due to not holding the start but-
ton in long enough (minimum of 2 seconds) or due to a
faulty flashing circuit. The light will remain on when the
engine has been shut down due to a fault in the alter-
nator, regulator, or the cooling blower belt.
7. IDLER SWITCH
Has two positions as follows:
A) In the “High” position , the engine runs at
the high idle speed controlled by the governor.
B) In the “Auto” / position, the idler oper-
ates as follows:
a. When switched from “High” to “Auto” or after
starting the engine, the engine will operate at full
speed for approximately 15 seconds and then go
to low idle speed.
b. When the electrode touches the work or power is
drawn for lights or tools (approximately 100 Watts
minimum) the engine accelerates and operates
at full speed.
c. When welding ceases or the AC power load is
turned off, a fixed time delay of approximately 15
seconds starts.
d. If the welding or AC power load is not restarted
before the end of the time delay, the idler reduces
the engine speed to low idle speed.
e. The engine will automatically return to high idle
speed when the welding load or A.C. power load
is reapplied.
Idler Operational exceptions
When the WELDING TERMINALS switch is in the
“Welding Terminals Remotely Controlled” position the
idler will operate as follows:
a. When the triggering device (Amptrol, Arc Start
Switch, etc.) is pressed the engine will accelerate
and operate at full speed provided a welding load is
applied within approximately 15 seconds.
• If the triggering device remains pressed but no weld-
ing load is applied within approximately 15 seconds
the engine will return to low idle speed.
• If the triggering device is released or welding ceases
the engine will return to low idle speed after approxi-
mately 15 seconds.
8. HOUR METER
The hour meter displays the total time that the engine
has been running. This meter is a useful indicator for
scheduling preventive maintenance.
COMMANDER 400
B-5
OPERATION
B-5
WELDER CONTROLS (Items 9 through 14 )
9. OUTPUT RANGE SWITCH & OUTPUT
CONTROL
These two controls allow you to select between various
welding output slopes and adjust the desired welding
output. Refer to Table B.1 for a description of how
these two controls work.
Table B.1 Output Range Switch and Output Control
Functions
1
If the OUTPUT RANGE switch is positioned between settings the
previous setting is maintained until the switch is properly positioned
on a setting.
2
OUTPUT CONTROL also controls O.C.V. while in the 6 sloped out-
put ranges.
10. DIGITAL OUTPUT METER
The digital output meter is located in the center of the
control panel between the two large control knobs. The
meter allows the output current level to be set prior to
welding. During the welding process the meter dis-
plays the actual output current.
11. WELDING TERMINALS SWITCH
The toggle switch on the control panel labeled
“Welding Terminals Always On” and “Welding
Terminals Remotely Controlled”: is used to control the
operation of the “solid state contactor” which allows for
the selection of “Hot” or “Cold” welding terminals.
With the switch in the “Welding Terminals Always On”
position the contactor is closed and the welding termi-
nals are always “Hot”.
With the switch in the “Welding Terminals Remotely
Controlled” position the contactor operation is con-
trolled by an Amptrol, Arc Start Switch or some other
type of triggering device through the use of a control
cable connected to the 6-pin MS connector.
When the triggering device is pressed the contactor is
closed and the welding terminals are “Hot”.
When the triggering device is released the contactor is
opened and the welding terminals are “Cold”.
12. LOCAL /REMOTE SWITCH
The toggle switch on the control panel labeled
“Local/Remote” gives the operator the option of con-
trolling the output at the welder control panel or at a
remote station.
For remote control the toggle switch is set in the
“Remote” position.
For control at the welder control panel, the toggle
switch is set in the “Local” position.
13. 6 - PIN CONNECTOR
The 6-pin connector located on the control panel
allows for connection of Remote Control accessories.
14. WELD OUTPUT TERMINALS + AND -
These 1/2 - 13 studs with flange nuts provide welding
connection points for the electrode and work cables.
For positive polarity welding the electrode cable con-
nects to the “+” terminal and the work cable connects
to this “-” terminal. For negative polarity welding the
work cable connects to the “+” terminal and the elec-
trode cable connects to this “-” terminal.
AUXILIARY POWER CONTROLS
(Items 15 - 19 )
15. 120/240VAC RECEPTACLE
This is a 120/240VAC (14-50R) receptacle that pro-
vides 240VAC or can be split for 120VAC single phase
auxiliary power. This receptacle has a 50 amp rating.
Refer to the AUXILIARY POWER RECEPTACLES sec-
tion in the installation chapter for further information
about this receptacle. Also refer to the AUXILIARY
POWER OPERATION section later in this chapter.
16. 50 AMP CIRCUIT BREAKERS
These circuit breaker provide separate overload cur-
rent protection for each 120V circuit at the 240V recep-
tacle.
COMMANDER 400
Sloped Output for
Pipe Welding.
(all models)
Constant Current
Output for
Fabrication and
General Purpose
Welding (This set-
ting also used for
TIG) (all models)
Constant Voltage
Output for Wire
Welding (Stick &
Wire model only)
6 Range
Settings
90, 120, 180,
230, 270, 400
(Max. current on
each setting)
1 Range setting
50-575 Amps
1 Range setting
12 to 40 Volts
Provides a fine
adjustment of
welding current
or voltage from
Min (1) to Max
(10) within each
range
Range
Switch
1
Control
2
B-6
OPERATION
B-6
17. 120VAC RECEPTACLES
These two 120VAC (5-15R) receptacles with GFCI pro-
tection provide 120VAC for auxiliary power. These
receptacles have a 20 amp total rating. Refer to the
AUXILIARY POWER RECEPTACLES section in the
installation chapter for further information about these
receptacles. Also refer to the AUXILIARY POWER
OPERATION section later in this chapter.
18. 15 AMP CIRCUIT BREAKERS
These circuit breakers provide separate overload cur-
rent protection for each 120V receptacle.
19. GROUND STUD
Provides a connection point for connecting the
machine case to earth ground for the safest grounding
procedure. Refer to “MACHINE GROUNDING” in the
Installation chapter for proper machine grounding infor-
mation.
WIRE FEEDER MODE CONTROLS
(Items 20 - 24 Stick & Wire model only)
20. WELD OUTPUT TERMINAL - WIRE
This 1/2-13 stud with flange nut provides a welding
connection point for the electrode and work cables. For
positive polarity welding the electrode cable connects
to the “+” terminal and the work cable connects to this
“-” terminal. For negative polarity welding the work
cable connects to the “+” terminal and the electrode
cable connects to this “-” terminal.
21. 15 AMP CIRCUIT BREAKER
This circuit breaker provides overload protection for the
14-pin connector.
22. VOLTMETER +/- SWITCH
Changes the polarity display on the wire feeder.
23. VOLTS-AMPS SWITCH
Switches the display between volts and amps.
24. 14 - PIN CONNECTOR
For quick connection of wire feeder control cable.
ENGINE OPERATION
STARTING THE ENGINE
1. Open the engine compartment door and check that
the fuel shutoff valve located to the left of the fuel fil-
ter housing is in the open position (lever to be in line
with the hose).
2. Check for proper oil level on the oil dipstick. Close
engine compartment door.
3. Remove all plugs connected to the AC power receptacles.
4. Set IDLER switch to “AUTO”.
5. Set the RUN/STOP switch to “RUN”. Observe that all
engine protection lights momentarily turn on, some lights
may turn off before starting. Check the fuel gauge to
make sure that there is an adequate fuel level.
6. Press and hold the engine START button for a minimum
of 2 seconds.
7. Release the engine START button when the engine starts.
8.
Check that the indicator lights are off. If the LOW FUEL light is
on , the engine will shutdown 30 minutes after starting. If any
other indicator light is on after starting, the engine will shut-
down in a few seconds. Investigate any indicated problem.
9. Allow the engine to warm up at low idle speed for several
minutes before applying a load and/or switching to high
idle. Allow a longer warm up time in cold weather.
COLD WEATHER STARTING / RUNNING
With a fully charged battery and the proper weight oil,
the engine should start satisfactorily even down to
about 0°F. If the engine must be frequently started
below 10
o
F, it may be desirable to install the optional
ether starter kit (K825-1). Installation and operating
instructions are included in the kit. Use ether starting
only when required because excessive use shortens
engine life. If the engine must be operated in extreme
cold environments 0°F to -35°F (-18°C to -37°C) an
optional Cold Weather Kit (K1665-1) is available.
Installation and operating instructions are included in
the kit.
STOPPING THE ENGINE
1. Switch the RUN/STOP switch to “STOP”. This turns
off the voltage supplied to the shutdown solenoid. A
backup shutdown can be accomplished by shutting
off the fuel valve located on the fuel filter housing.
BREAK-IN PERIOD
The engine used to supply power for your welder is a
heavy duty, industrial engine. It is designed and built
for rugged use. It is very normal for any engine to use
small quantities of oil until the break-in is accom-
plished. Check the oil level twice a day during the
break-in period (about 200 running hours).
IMPOR
TANT
IN ORDER TO ACCOMPLISH THIS BREAK-IN, THE
UNIT SHOULD BE SUBJECTED TO HEAVY LOADS,
WITHIN THE RATING OF THE MACHINE. AVOID
LONG IDLE RUNNING PERIODS.
COMMANDER 400
B-7
OPERATION
B-7
TYPICAL FUEL CONSUMPTION
Refer to Table B.2 for typical fuel consumption of the
Commander 400’s Engine for various operating sce-
narios.
Table B.2 Deutz F3L 912 Engine Fuel Consumption
WELDER OPERATION
STICK WELDING
The Commander 400 can be used with a broad range
of DC stick electrodes.
The OUTPUT RANGE switch provides six o
verlapping
slope controlled current ranges. The OUTPUT CON-
TROL adjusts the current from minimum to maximum
within each range. Open circuit voltage is also con-
trolled by the OUTPUT CONTROL in the slope con-
trolled setting. These slope controlled settings are
intended for “out-of-position” welding, including pipe
where the operator would like to control the current
level by changing the arc length.
PIPE WELDING
When using a sloped range, high open circuit voltage
setting provides the softest arc with best resistance to
pop-outs. To get this characteristic, set the OUTPUT
RANGE switch to the lowest setting that still provides
the current you need and set the OUTPUT CONTROL
near maximum. For example: to obtain 175 amps and
a soft arc
, set the OUTPUT RANGE switch to the “180
MAX” position and then adjust the OUTPUT CON-
TROL for 175 amps.
When a forceful “digging” arc is required, use a higher
setting and lower open circuit voltage. For example: to
obtain 175 amps and a forceful arc, set the to the “230
MAX” position and then adjust the OUTPUT CON-
TROL to get 175 amps.
GENERAL WELDING
The seventh position of the OUTPUT RANGE switch is
designed for hor
izontal welds with all types of elec-
trodes especially low hydrogen. The OUTPUT CON-
TROL adjusts the full range of 50 to 575 amps. This
setting provides a soft, constant current arc. If a more
forceful arc is desired, then select the proper range
from the slope controlled current ranges.
TIG WELDING
The Commander 400 can be used in a wide variety of
DC Tungsten Inert Gas (TIG) welding applications for
DC TIG welding up to 400A at a 20% duty cycle, 300A
at a 60% duty cycle and 250A at a 80% duty cycle.
Refer to Table B.3 for recommended output setting
depending on the tungsten electrode size. The
Commander can be used without a TIG module or Hi-
Freq Unit for scratch start DC TIG welding. Using a
K799 Hi-Freq Unit or K930-1 TIG Module enables DC
TIG welding without having to scratch start. The end of
this section also details Commander 400 settings
when using either of these units for DC TIG welding.
Also refer to the Accessories chapter for recommend-
ed equipment for TIG welding.
ARC GOUGING
Set the output range switch to the General purpose
position (50-575). For current setting, refer to The
Procedure Handbook of Arc Welding, section on arc
gouging (13.5) or the consumable manufacturer’s rec-
ommended current rating.
COMMANDER 400
Low Idle - No
Load 1350 RPM
High Idle - No
Load 1900 RPM
DC CC Weld
Output 400
Amps @ 40 Volts
Auxiliary Power
10,000 VA
.30 gallons/hour
(1.36 liters/hour)
.78 gallons/hour
( 3.55 liters/hour)
1.84 gallons/hour
( 8.36 liters/hour)
1.32 gallons/hour
(6.00 liters/hour)
83.3
32.1
13.6
18.9
Deutz F3L 912
44.2 Hp
@ 1800 RPM
Running Time for
25 gallons
(Hours)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Lincoln Electric Commander 400 Manuel utilisateur

Catégorie
Système de soudage
Taper
Manuel utilisateur

dans d''autres langues