Bestway P3066 Le manuel du propriétaire

Catégorie
Ventilateurs ménagers
Taper
Le manuel du propriétaire
©2022 Bestway Inflatables & Material Corp.
All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle Rechte vorbehalten/Tutti i diritti riservati
Trademarks used in some countries under license from/
Marques utilisées dans certains pays sous la licence de/
Marcas comerciales utilizadas en algunos países bajo la licencia de/
Die Warenzeichen werden in einigen Ländern verwendet unter Lizenz der/
Marchi utilizzati in alcuni paesi concessi in licenza a
Bestway Inflatables & Material Corp., Shanghai, China
Manufactured, distributed and represented in the European Union by/
Fabriqués, distribués et représentés dans l’Union Européenne par/Fabricado, distribuido y representado en la Unión Europea por/
Hergestellt, vertrieben und in der Europäischen Union vertreten von/Prodotto, distribuito e rappresentato nell'Unione Europea da
Bestway Europe S.p.a., Via Resistenza, 5, 20098 San Giuliano Milanese (Milano), Italy
Distributed in Latin America by/Distribué en Amérique latine par/Distribuido en Latinoamérica por/Distribuído na América Latina por
Bestway Central & South America Ltda, Salar Ascotan 1282, Parque Enea, Pudahuel, Santiago, Chile
Distributed in Australia & New Zealand by Bestway Australia Pty Ltd, Unit 2/98-104 Carnarvon St Silverwater, NSW 2128, Australia
Tel: Australia: (+61) 2 9037 1388; New Zealand: 0800 142 101
Distributed in United Kingdom by Bestway Corp UK Ltd. 8 Wentworth Road, Heathfield Industrial Estate, Newton Abbot, Devon, TQ12 6TL
Exported by/Exporté par/Exportado por/Exportiert von/Esportato da
Bestway (Hong Kong) International Ltd./Bestway Enterprise Company Limited
Suite 713, 7/Floor, East Wing, Tsim Sha Tsui Centre, 66 Mody Road, Kowloon, Hong Kong
www.bestwaycorp.com
P3066
2
OWNER'S MANUAL
NOTICE: READ CAREFULLY BEFORE OPERATING
AND SAVE THESE INSTRUCTIONS.
FOR HOUSEHOLD USE ONLY.
Model No.P3066
WARNING:
1. Do not use the pump continuously more than 5 minutes.
It can only be used again after at least 15 minutes of
cooling.
2. Children are strictly prohibited from operating the pump.
3. After use, airbeds may require additional air to increase
firmness. Add air to proper firmness.
4. Make sure to fully charge the pump before inflation.
5. Please charge immediately when any of the lights are
flashing.
6. This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.
7. The appliance must only be supplied at safety extra low
voltage corresponding to the marking on the appliance.
8. The battery must be removed from the appliance before
it is scrapped.
9. The appliance must be disconnected from the supply
mains when removing the battery.
10. This appliance contains battery that is non-replaceable.
11. The battery is to be disposed of safely.
3
DISPOSAL
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
OPERATION
1. Charging:
1.1. Two lithium cell 2200mAh rechargeable batteries are inside the pump. Please
charge the batteries for at least 6 hours before first use.
1.2. The pump can only be used with provided Micro USB charging line. Only a DC 5V
adaptor with safety certification may be used for this pump.
1.3. When using charger with 2A electricity, the charging time will be around 4 hours. If
using an adaptor with rated current less than 2A, the charging time will be longer.
1.4. When charging, three indicator lights turn on in cycle. Three indicator lights are on
at the same time indicates the electricity is full.
2. Do not block the rotation of the motor or the fan blades. Do not insert the objects into
or interfere with the fan chamber.
3. The pump must be stored in a dry location at -20-45 temperature. If the pump is
not used for more than 6 months, the battery will discharge. The battery must be
charged every 3 months.
DC 5V DC 5V
4
Green light: Inflation is complete and the airbed has reached
optimal air pressure.
Blue light: The main pump or secondary pump is working.
Battery power button: Displays battery power. The indicator at
the bottom flashes when the power is low.
On/Off button: The indicator light is always on when the
product is working.
NOTE: This pump has an auto-reinflation feature.
Please keep the pump turned on to maintain the specified
pressure level.
The two buttons on the control panel will not work when
the pump is charging.
ALARM: Both green light and blue light are flashing:
The airbed cannot reach the specified pressure level.
Please follow steps below.
1. Ensure airbed and valve do not leak air.
2. If there are no problem, please press the power button.
The light will stop flashing.
NOTE: Drawings for illustration purpose only. May
not reflect actual product. Not to scale.
83
4.1 4.2 4.3
4.4 4.5 4.6
59°F
PVC
30min
...
30s
H
24
50cm(19in)
3.1 3.2 3.3
303021302606
30min
...
30s