INSTALLATION INSTRUCTIONS
249-LED Wall Sconce
BL-24959
Read all instructions before installing.
System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or acces-
sories designated for use by WAC Lighting/dweLED/Modern Forms. Substitution of parts or accessories not designated for use with this product
by WAC Lighting/dweLED/Modern Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized
dealer or the manufacturer if any parts are damaged or missing.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
Lisez toutes les instructions avant l’installation.
Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux règlements
locaux.
Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits WAC Lighting/dweLED/Modern Forms. Remplacer des pièces ou
accessoires non conçus pour ce produit WAC Lighting/dweLED/Modern Forms pourrait causer des dommages corporels ou matériels et pourrait
également causer l’annulation de la garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endom-
magées.
HARDWARE
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Wire Connector
Qty:3PCS+1Extra
Wood Screw
Qty:2PCS+1Extra
Plastic Anchor
Qty:2PCS+1Extra
Mounting Screw
Qty:1Extra
Fixture tail
Qty:1PC
Driver
Qty:1PC
AB
CDE
FGH
Conversion Plate
Qty:1PC
Mounting Ring
Qty:1PC
Conversion Plate Screw
Qty:1PC+1Extra
I
2
INSTALLATION INSTRUCTIONS
249-LED Wall Sconce
BL-24959
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
FIG. 3 Wiring
FIG. 1 MOUNT ON SWITCH BOX
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
am. JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760

1. Shut o the power at the circuit breaker and remove existing xture,
including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear
area. Be careful not to lose any small parts necessary for installation.

3. Remove the mounting screw (D) from the xture.
4. Secure the xture tail (E) to screw into the xtures tube.
5. Drill holes in the wall aligned with the key holes located in the mounting plate, insert the plastic anchor (C).
6. Connect the driver’s(F) input wires with switch box wires as shown in Fig.1, making sure that all wire connectors (A) are secured. If your
outlet box has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire
directly to the mounting plate using the green screw provided. After wires are connected, tuck them carefully inside the switch box

Male end connector
Female end connector
Swit
c
h box
Wire Connector
Mounting Plate
Fixture
Fixture tail
Driver 3 3/8" × 1 3/8" × 1 3/16"
Plastic
A
nch
or
Wood Screw
Junction Box Screw
Mounting Screw
A
B
C
D
E
F
FIG.2 MOUNT ON JUNCTION BOX.
Ground Wire
Junction Box
Mounting Ring
Conversion
P
late
Junction Box Screw
Conversion
P
late
Screw
Wire Connector
Driver 3 3/8" × 1 3/8" × 1 3/16"
G
H
A
F
I
Purple - Dim+
Pink or Gray - Dim-
Black - Hot
White - NeutralFemale end connector
Fig.4 Driver wires
Mounting Ring DimensionsConversion Plate Dimensions
Ø4
1 3/8
1 3/4
4 1/2
6
Mounting Plate Dimensions
10 7/8
2 5/8
1 5/8
1 3/8
1 3/81 5/8
7 1/2
3
INSTALLATION INSTRUCTIONS
249-LED Wall Sconce
BL-24959
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
am. JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
7. Secure the mounting plate to the switch box using the junction box screw. Fasten it to the wall using wood screw (B) onto the plastic
anchor. The side of the mounting plate marked “GND” must face out.
8. Connect the driver output wires with the xture by Female/Male end connector.
9. Place the xture over the mounting plate, and secure it with mounting screw (D).
10. This xture features electronic low voltage (ELV or TRAIC) or 1-10V dimming capabilities. See Fig.4 for specic dimming wires information.


3. Remove the mounting screw (D) from the xture.
4. Secure the xture tail (E) to screw into the xtures tube.
5. Drill holes in the wall aligned with the key holes located in the mounting plate, insert the plastic anchor (C).
6. Secure the mounting plate to the conversion plate (H) using conversion plate screw(G).
7. Connect the driver’s(F) input wires with junction box wires as shown in Fig.2, making sure that all wire connectors (A) are secured. If your
outlet box has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire
directly to the mounting plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

8. Secure the mounting ring (I) to the junction box using the junction box screw. Make sure the two holes (Spacing 2-3/4”) are horizontal as
shown in Fig. 2.
9. Secure the mounting plate and conversion plate (H) to the mounting ring with junction box screw. Fasten it to the wall using wood screw
(B) onto the plastic anchor. The side of the mounting plate marked GND” must face out.
10. Connect the driver output wires with the xture by Female/Male end connector.
11. Place the xture over the mounting plate, and secure it with mounting screw (D).
12. This xture features electronic low voltage (ELV or TRAIC) or 1-10V dimming capabilities. See Fig.4 for specic dimming wires information.